Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Sensitive ion detection device and method for analysis of compounds as vapors in gases

An ion mobility spectrometer (IMS) for the detection of trace gaseous molecular compounds dissolved or suspended in a carrier gas, particularly in ambient air, without preconcentration or the trapping of analyte particles. The IMS of the invention comprises an ionization volume of greater than 5 cm.sup.3 and preferably greater than 100 cm.sup.3. The larger size ionizers of this invention enable analysis of trace (<1 ppb) of sample compounds in the gas phase. To facilitate efficient ion motion through the large volume ionization and reaction regions of the IMS, an electric field gradient can be provided in the ionization region or in both the ionization and reaction regions. The systems can be implemented with radioactive ionization sources, corona discharge ion sources or ions can be formed by photoionization. In specific embodiments, particularly when the sample gas is ambient air, the sample gas is heater prior to entry into the instrument, the instrument is run at temperatures above ambient, and the instrument can be heated by contact with heated sample gas exiting the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searches for sterile neutrinos with NOvA

Contradictory evidence has been presented on the issue of neutrino mixing between the three known active neutrinos and light sterile neutrino species. Apparent short-baseline neutrino oscillations observed by the LSND and MiniBooNE experiments, the collective evidence of the reactor neutrino anomaly, and the gallium anomaly all point towards sterile neutrinos with mass at the 1 eV level. While these results are tantalizing, they are not conclusive as they are in tension with null results from other short-baseline experiments, and with disappearance searches in longbaseline and atmospheric experiments. The NOvA (NuMI Off-Axis v e Appearance) experiment may help clarify the situation by searching for disappearance of active neutrinos from the NuMI (Neutrinos from the Main Injector) beam over a baseline of 810 km. We describe the method used by NOvA to look for oscillations into sterile neutrinos at the Far Detector (FD) through the disappearance of neutral-current (NC) neutrino events, including preliminary results of this search. In addition, the Near Detector (ND) is well suited for searching for anomalous short-baseline oscillations and probing the LSND and MiniBooNE sterile neutrino allowed regions using a variety of final states. We also present a novel method for selecting samples with high purity at the ND using convolutional neural networks. Furthermore, based on this method, the sensitivity to anomalous short-baseline nt appearance are shown, and searches for anomalous v e appearance and v μ disappearance at the NOvA ND are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NOvA Short-Baseline Tau Neutrino Appearance Search

Standard three-flavor neutrino oscillations have well explained by a wide range of neutrino experiments. However, the anomalous results, such as electron-antineutrino excess seen by LSND and MiniBooNE do not fit the three-flavor paradigm. This can be explained by an additional fourth flavor sterile neutrino at a larger scale than the existing three flavor neutrinos. The NOvA experiment consists of two finely segmented, liquid scintillator detectors operating 14 .6 mrad off-axis from the NuMI muon-neutrino beam. The Near Detector is located on the Fermilab campus, 1 km from the NuMI target, while the Far Detector is located at Ash River, MN, 810 km from the NuMI target. The NOvA experiment is primarily designed to measure electron-neutrino appearance at the Far Detector using the Near Detector to control systematic uncertainties; however, the Near Detector is well suited for searching for anomalous short-baseline oscillations. This poster will present a novel method for selecting tau neutrino interactions with high purity at the Near Detector using a convolutional neural network. Using this method, the sensitivity to anomalous short-baseline tau-neutrino appearance due to sterile neutrino oscillations will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperCDMS Background Models for Low-Mass Dark Matter Searches

An abundance of astrophysical and cosmological evidence indicates the existence of a non-luminous, non-baryonic form of matter, called dark matter, that is approximately a quarter of all energy in the universe. One promising candidate for dark matter is the Weakly Interacting Massive Particle (WIMP) which interacts with baryonic matter at most on the scale of the weak force. The Cryogenic Dark Matter Search (CDMS) experiment aims to detect the nuclear recoils induced by the elastic scattering of WIMPs off of germanium nuclei. This is a rare signal and difficult to detect, especially the low-energy recoils that are produced by low-mass dark matter. The CDMS project operated at the Soudan Underground Laboratory from 2003--2015, with an upgrade to the SuperCDMS experiment in 2012. The germanium detectors were operated at 50~mK and able to measure both the ionization and athermal phonons produced in a particle interaction. Measuring two signals enables discrimination between electron recoil and nuclear recoil events. An alternative operating mode for the detectors is called the CDMS low ionization threshold experiment (CDMSlite), where a higher bias was applied to the detectors and only the phonon signal analyzed. This method increased sensitivity to low-mass dark matter interactions, but sacrificed discrimination capability. The CDMSlite spectrum had a large contribution from electron recoil background events. From the information gained during the first two CDMSlite Runs, a background model was developed for the third and final CDMSlite Run. Analytical descriptions were identified for those backgrounds that were theoretically known, e.g. tritium $\beta$-spectrum, and Geant simulations were used to understand and predict the low-energy spectra from other sources, e.g. Compton scattering. Multiple new models were developed for detectors operated in CDMSlite at Soudan. These include the analytical formula for Compton scattering, and empirical models for surface backgrounds from $^{210}$Pb contamination of the germanium crystals and detector housing. In order to accurately describe the surface events, a new detector response function was developed that included information about the electric field and energy resolution of the detector. These models were essential to the implementation of a profile likelihood analysis of the CDMSlite Run 3 data, which improved on the sensitivity to dark matter over the Run 2 optimum interval analysis for WIMP masses above 2.5~GeV/$c^2$. This demonstrated a successful application of a likelihood analysis to the high-voltage operating mode, and the potential for these analyses in the future SuperCDMS SNOLAB experiment. For the SuperCDMS SNOLAB experiment, the change in background rates from radiogenic neutrons was considered as additional towers of detectors were added, and the feasibility of an active neutron veto as a potential upgrade for large payloads was studied. This veto could be constructed of plastic scintillator with layers of gadolinium resin, and would aid in reducing the nuclear recoil single scatter background that is indistinguishable from the WIMP signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables: Preprint

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds after disturbance. To address this challenge, this paper proposes a frequency stability unit commitment constraint considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Thus, this paper first analyzes a frequency nadir differential equation that considers SG governor model and three kinds of FFR provided by IBRs. A system frequency nadir estimation framework is developed with consideration of various conventional SG and IBR models. The accuracy of this frequency estimation framework is validated by largest N-1 contingency simulation result of a real island system. Then, the adaptive inertia frequency stability unit commitment constraint is derived from sensitivity analysis method. Finally, we demonstrate the effectiveness of our developed constraints with one year day-ahead unit commitment results of the real island system.

fast frequency response↗

Materials for the Photoluminescence-Based Detection of Economically Critical Metals

Critical metals, such as rare earth elements (REEs), cobalt, lithium, aluminum, nickel, and others, are essential to advanced technologies and renewable energy in particular. Widespread global adoption of renewable energy technologies has spurred dramatic demand increases for these metals; however, the global supply of these metals is highly monopolistic and conventional mining poses economic and environmental challenges. As a result, there is increasing interest in domestic production from alternative resources such as coal and its utilization byproducts. Slow and expensive characterization costs remain a significant barrier for domestic production. Here, luminescent sensing materials and platforms are presented that provide an alternative to the current state-of-the-art characterization methods; highly sensitive and selective sensing materials for cobalt, aluminum, and rare earth elements are presented, as well as compact, inexpensive platforms capable of analyzing signal from these materials for rapid characterization of critical metal content.

Crawford, Scott↗

Materials for the Photoluminescence-Based Detection of Economically Critical Metals

Critical metals, such as rare earth elements (REEs), cobalt, lithium, aluminum, nickel, and others, are essential to advanced technologies and renewable energy in particular. Widespread global adoption of renewable energy technologies has spurred dramatic demand increases for these metals; however, the global supply of these metals is highly monopolistic and conventional mining poses economic and environmental challenges. As a result, there is increasing interest in domestic production from alternative resources such as coal and its utilization byproducts. Slow and expensive characterization costs remain a significant barrier for domestic production. Here, luminescent sensing materials and platforms are presented that provide an alternative to the current state-of-the-art characterization methods; highly sensitive and selective sensing materials for cobalt, aluminum, and rare earth elements are presented, as well as compact, inexpensive platforms capable of analyzing signal from these materials for rapid characterization of critical metal content.

Crawford, Scott↗

Evaluation and optimization of the advanced signal counting techniques on weldments

The signal counting technique with the Delta ultrasonic method is evaluated and optimized for flaw detection in aluminum welds. A comparison is made between the counting and conventional amplitude-gate methods to detect flaws. No conclusion is drawn on the sensitivity of these two methods to detect flaws when the mismatch at the welds is small (25 mils or less). When the mismatch is 25 mils or more, the signal counting method is more sensitive. Of the 24 welded specimens, 50 flaws were found by X-ray inspection and 59 by the Delta method. On 1/4-inch thick welds, X-ray is equal to or slightly more sensitive than Delta method, but on the 1/2-inch thick welds Delta ultrasonic appears more sensitive in flaw detection.

Yee, B. G. W.↗

A suitable deposition method of CdS for high performance CdS-sensitized ZnO electrodes: Sequential chemical bath deposition

A suitable deposition method of CdS is necessary for the high performance CdS-sensitized ZnO electrodes. In this paper, chemical bath deposition (CBD) and sequential chemical bath deposition (S-CBD) methods were used to deposit CdS on ZnO mesoporous films for ZnO/CdS electrodes. The analysis results of XRD patterns and UV-vis spectroscopy indicated that CBD deposition method leaded to the dissolving of ZnO mesoporous films in deposition solution and thickness reduction of ZnO/CdS electrodes. Absorption in visible region by the ZnO/CdS electrodes with CdS deposition by S-CBD was enhanced as deposition cycles increased due to the stability of ZnO mesoporous films in the S-CBD deposition solutions. The results of photocurrent-voltage (I-V) measurement showed that the performance of ZnO/CdS electrodes with CdS deposition by CBD first increased and then decreased as deposition time increased, and the greatest short-circuit current (J{sub sc}) was obtained at the deposition time of 4 min. The performance of ZnO/CdS electrodes with CdS deposition by S-CBD increased as deposition cycles increased, and both open-circuit voltage (V{sub oc}) and J{sub sc} were greater than those electrodes with CdS deposition by CBD when the deposition cycles of S-CBD were 10 or greater. These results indicated that S-CBD is a more suitable method for high performance ZnO/CdS electrodes. (author)

14 SOLAR ENERGY↗

Measurement of ion and electron temperatures in plasma blobs by using an improved ion sensitive probe system and statistical analysis methods

We have measured ion temperature as well as electron temperature in plasma blobs observed in a linear plasma device by using an improved ion sensitive probe. Current-voltage characteristics of the ion sensitive probe inside and outside plasma blobs were re-constructed with a conditional sampling method. It is clearly found that both ion and electron temperatures in plasma blobs decrease more slowly in a cross-field direction than those in a bulk plasma without plasma blobs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Nonlinear Impact-Echo Test for Quantitative Evaluation of ASR Damage in Concrete

Nonlinear acoustic methods demonstrate high sensitivity for concrete damage evaluation. Among these methods, nonlinear resonance acoustic methods have been widely used in laboratory tests on small scale test samples. In this study, a nonlinear impact-echo (IE) method for concrete damage evaluation was introduced, in which the IE frequency shift was measured at different impact force levels. The nonlinear IE test and the nonlinear impact resonance acoustic spectroscopy (NIRAS) test share similarities in the experimental setup and analysis method. However, the nonlinear IE test excites a local thickness resonance mode of a member instead of the global resonance vibration. Therefore, the analyzed mode is unaffected by member boundary conditions and is applicable to large concrete structural members. To identify the fundamental IE frequencies, multiple impacts were applied along the members. Once the fundamental IE frequencies were determined, the effectiveness of the nonlinear IE method was evaluated by testing seven concrete beam specimens with varying levels of alkali-silica reaction (ASR) damage. In conclusion, the nonlinear IE test demonstrates high sensitivity to concrete damage and allows for quantitative assessment of the damage state of concrete without a baseline measurement.

36 MATERIALS SCIENCE↗

Vibrational sensitivity of a measuring instrument and methods of increasing the accuracy of its determinations

The properties and peculiarities of two groups of measuring systems reacting to vibrations are discussed. Specifically, results of the action of a three dimensional, cophasal, monoharmonic vibration on the linear system of a measuring instrument was analyzed. Data are also given on the connection between vibration sensitivity and vibration resistance for instruments, methods for estimating vibration resistance, and formulas for expressing test results of vibration resistance. Experimental data are also given for decreasing errors in nonlinear systems during vibrations.

Mironov, Y. S.↗

Adjoint Sensitivity Computations for an Embedded-Boundary Cartesian Mesh Method and CAD Geometry

Cartesian-mesh methods are perhaps the most promising approach for addressing the issues of flow solution automation for aerodynamic design problems. In these methods, the discretization of the wetted surface is decoupled from that of the volume mesh. This not only enables fast and robust mesh generation for geometry of arbitrary complexity, but also facilitates access to geometry modeling and manipulation using parametric Computer-Aided Design (CAD) tools. Our goal is to combine the automation capabilities of Cartesian methods with an eficient computation of design sensitivities. We address this issue using the adjoint method, where the computational cost of the design sensitivities, or objective function gradients, is esseutially indepeudent of the number of design variables. In previous work, we presented an accurate and efficient algorithm for the solution of the adjoint Euler equations discretized on Cartesian meshes with embedded, cut-cell boundaries. Novel aspects of the algorithm included the computation of surface shape sensitivities for triangulations based on parametric-CAD models and the linearization of the coupling between the surface triangulation and the cut-cells. The objective of the present work is to extend our adjoint formulation to problems involving general shape changes. Central to this development is the computation of volume-mesh sensitivities to obtain a reliable approximation of the objective finction gradient. Motivated by the success of mesh-perturbation schemes commonly used in body-fitted unstructured formulations, we propose an approach based on a local linearization of a mesh-perturbation scheme similar to the spring analogy. This approach circumvents most of the difficulties that arise due to non-smooth changes in the cut-cell layer as the boundary shape evolves and provides a consistent approximation tot he exact gradient of the discretized abjective function. A detailed gradient accurace study is presented to verify our approach. Thereafter, we focus on a shape optimization problem for an Apollo-like reentry capsule. The optimization seeks to enhance the lift-to-drag ratio of the capsule by modifyjing the shape of its heat-shield in conjunction with a center-of-gravity (c.g.) offset. This multipoint and multi-objective optimization problem is used to demonstrate the overall effectiveness of the Cartesian adjoint method for addressing the issues of complex aerodynamic design. This abstract presents only a brief outline of the numerical method and results; full details will be given in the final paper.

Nemec, Marian↗

Frequency Response of Pressure Sensitive Paints

An experimental method for measuring the frequency response of Pressure Sensitive Paints (PSP) is presented. These results lead to the development of a dynamic correction technique for PSP measurements which is of great importance to the advancement of PSP as a measurement technique. The ability to design such a dynamic corrector is most easily formed from the frequency response of the given system. An example of this correction technique is shown. In addition to the experimental data, an analytical model for the frequency response is developed from the one dimensional mass diffusion equation.

Winslow, Neal A.↗

SENSITIVITY OF A REACTIVE-TRACER BASED ESTIMATE OF THERMAL BREAKTHROUGH IN AN EGS TO PROPERTIES OF THE RESERVOIR AND TRACER

Reactive tracers have long been considered a possible means of measuring thermal drawdown in a geothermal system, before significant cooling occurs at the extraction well. Here, we examine the sensitivity of the proposed method to reservoir cooling and demonstrate that while the sensitivity of the method as generally proposed is low, it may be practical under certain conditions. Our analyses suggest that modifications to that method, where practical, could provide much greater sensitivity. In particular, if the reaction can be quenched before maximum temperature is reached, the sensitivity is greatly enhanced. Push-pull tracer tests conducted at the injection well demonstrate similar advantages. Other alternatives, such as combinations of tracers, and tracers with parallel or chain decay behavior may offer similar advantages.

15 GEOTHERMAL ENERGY↗