Search NASA⌕ Search

SEARCH · Search NASA

Results for “software performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

SU-F-19A-09: Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison

Purpose: To compare the performance of two deformable image registration (DIR) algorithms for contour propagation and to evaluate the accuracy of DIR for use with high dose rate (HDR) brachytherapy planning for cervical cancer. Methods: Five patients undergoing HDR ring and tandem brachytherapy were included in this retrospective study. All patients underwent CT simulation and replanning prior to each fraction (3–5 fractions total). CT-to-CT DIR was performed using two commercially available software platforms: SmartAdapt, Varian Medical Systems (Demons) and Velocity AI, Velocity Medical Solutions (B-spline). Fraction 1 contours were deformed and propagated to each subsequent image set and compared to contours manually drawn by an expert clinician. Dice similarity coefficients (DSC), defined as, DSC(A,B)=2(AandB)/(A+B) were calculated to quantify spatial overlap between manual (A) and deformed (B) contours. Additionally, clinician-assigned visual scores were used to describe and compare the performance of each DIR method and ultimately evaluate which was more clinically acceptable. Scoring was based on a 1–5 scale—with 1 meaning, “clinically acceptable with no contour changes” and 5 meaning, “clinically unacceptable”. Results: Statistically significant differences were not observed between the two DIR algorithms. The average DSC for the bladder, rectum and rectosigmoid were 0.82±0.08, 0.67±0.13 and 0.48±0.18, respectively. The poorest contour agreement was observed for the rectosigmoid due to limited soft tissue contrast and drastic anatomical changes, i.e., organ shape/filling. Two clinicians gave nearly equivalent average scores of 2.75±0.91 for SmartAdapt and 2.75±0.94 for Velocity AI—indicating that for a majority of the cases, more than one of the three contours evaluated required major modifications. Conclusion: Limitations of both DIR algorithms resulted in inaccuracies in contour propagation in the pelvic region, thus hampering the clinical utility of this technology. Further work is required to optimize these algorithms and take advantage of the potential of DIR for HDR brachytherapy planning.

60 APPLIED LIFE SCIENCES↗

An optimized FM-index library for nucleotide and amino acid search

Abstract Background Pattern matching is a key step in a variety of biological sequence analysis pipelines. The FM-index is a compressed data structure for pattern matching, with search run time that is independent of the length of the database text. Implementation of the FM-index is reasonably complicated, so that increased adoption will be aided by the availability of a fast and flexible FM-index library. Results We present AvxWindowedFMindex (AWFM-index), a lightweight, open-source, thread-parallel FM-index library written in C that is optimized for indexing nucleotide and amino acid sequences. AWFM-index introduces a new approach to storing FM-index data in a strided bit-vector format that enables extremely efficient computation of the FM-index occurrence function via AVX2 bitwise instructions, and combines this with optional on-disk storage of the index’s suffix array and a cache-efficient lookup table for partial k-mer searches. The AWFM-index performs exact match count and locate queries faster than SeqAn3’s FM-index implementation across a range of comparable memory footprints. When optimized for speed, AWFM-index is $$\sim $$ ∼ 2–4x faster than SeqAn3 for nucleotide search, and $$\sim $$ ∼ 2–6x faster for amino acid search; it is also $$\sim $$ ∼ 4x faster with similar memory footprint when storing the suffix array in on-disk SSD storage. Conclusions AWFM-index is easy to incorporate into bioinformatics software, offers run-time performance parameterization, and provides clients with FM-index functionality at both a high-level (count or locate all instances of a query string) and low-level (step-wise control of the FM-index backward-search process). The open-source library is available for download at https://github.com/TravisWheelerLab/AvxWindowFmIndex.

59 BASIC BIOLOGICAL SCIENCES↗

A Systematic Comparison for Consistent Scenario Development Using Microscopic Simulation Software

This study aims to explore a methodology that enables the development of consistent traffic micro simulation for emerging traffic and vehicle control technologies for improved mobility and energy efficiency across different modeling platforms. Researchers might study the same application on different platforms and have the need to benchmark across platforms. However, there lacks a systematic study on simulation software comparison, especially for emerging mobility and energy efficiency applications. For this, a systematic scenario development and evaluation approach is presented and demonstrated to compare scenarios generated in different traffic microsimulation platforms. Network-level and vehicle-level trip performance results of the traffic scenario are evaluated in three microscopic simulation platforms - VISSIM, AIMSUN, and SUMO. The results indicate that the network-level performance is consistent among the three software suites except when the demand is high, where the energy consumption performance varies.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

Light and Dark in Liquid Argon Time Projection Chamber Neutrino Detectors

Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors have emerged as a detector technology poised to perform measurements of neutrino interactions with unprecedented precision and as a result answer some of the largest open questions in neutrino physics in the coming decade. This thesis describes methods developed to tackle the computational challenges faced as LArTPC detectors increase in scale and complexity moving towards the multi-kiloton DUNE detectors. These include a new, approximated, model that enables rapid simulation of scintillation light in very large scale detectors, as well as the first demonstration of running the LArSoft software framework on a high performance computer. The high precision of LArTPC detectors designed for next-generation neutrino measurements enables them to also search for Beyond the Standard Model physics produced in high-energy proton--fixed-target collisions in neutrino beams. This thesis presents searches for two dark-sector models performed with the ArgoNeuT experiment: Heavy Neutral Leptons and Heavy QCD Axions. Between them, these models can provide solutions for various unresolved puzzles including neutrino mass generation, the baryon asymmetry of the universe, dark matter and the strong CP problem. In both cases, the dark-sector particles could be produced in the NuMI neutrino beam and can then decay to a pair of oppositely charged muons observable in ArgoNeuT and the downstream MINOS near detector. Both measurements required the development of novel experimental selection techniques and enabled new constraints to be set on the existence of these particles in previously unexplored parameter-space. These searches are both the first of their kind in LArTPC neutrino detectors and pave the way for searches at future neutrino facilities.Date of Award31 Dec 2022Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Construction and Composition Tools for Petascale Computing SCW0837 Progress Report

The majority of scientific software is distributed as source code. As the number of library dependencies and supported platforms increases, so does the complexity of describing the rules for configuring and building software. In this project, we have performed an empirical study of the magnitude of the build problem by examining the development history of two DOE-funded scientific software projects. We have developed MixDown, a meta-build tool, to simplify the task of building applications that depend on multiple third-party libraries. The results of this research indicate that the effort that scientific programmers spend takes a significant fraction of the total development effort and that the use of MixDown can significantly simplify the task of building software with multiple dependencies.

97 MATHEMATICS AND COMPUTING↗

Understanding the Impact of Dynamic Power Capping on Application Progress

Electrical power has become an important design constraint in high-performance computing (HPC) systems. On future HPC machines, power is likely to be a budgeted resource and thus managed dynamically. Power management software needs to reliably measure application performance at runtime in order to respond effectively to changes in application behavior. Execution time tells us little about how the science in the application is progressing toward an application-defined end goal. To the best of our knowledge, no study has defined or categorized online application progress in the context of power management. Based on semi-structured interviews with HPC application-specialists, we define an online notion of progress—an application-specific metric that can be monitored at runtime to provide a sense of the rate at which application science is being performed. Using instrumentation, we characterize and categorize the progress of various production scientific applications and benchmarks. We propose a model of the impact of dynamic power capping on application progress. By experimental evaluation, we show that our model accurately captures the general behavior of the progress of different classes of applications under a power cap. We believe that such a model is an important first step toward the design of more dynamic power management policies for HPC systems.

application progress↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models

Purpose: In x-ray mammography, some of the components that play significant role to early diagnosis are the x-ray source, the breast composition as well as the composition of the x-ray converter. Various studies have previously investigated separately the influence of breast characteristics and detector configuration on the optimization of mammographic imaging systems. However, it is important to examine the combined effect of both components in improving the signal transfer properties in mammography systems of the mammograms. In the present study, the authors compared and evaluated x-ray converters using software breast models and realistic mammographic spectra in terms of: (a) zero-frequency detective quantum efficiency (DQE) and (b) sensitivity. The impact of x-ray converter thickness on contrast threshold (C{sub TH}) for observer assessment, based on the Rose model, was demonstrated as well. Methods: Monte Carlo techniques were applied to simulate the x-ray interactions within the software breast phantoms and thereafter within the detective medium. Simulations involved: (a) two mammographic x-ray spectra: 28 kV Mo, 0.030 mm Mo, and 32 kV W, 0.050 mm Rh of different entrance surface air kerma (ESAK: 3-7 mGy), (b) realistic breast models (dense and fatty) and (c) x-ray converter materials most frequently considered in investigations on energy integrating digital mammography detectors: the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductive layer. Detector material thickness was considered to vary in the range from 50 mg/cm{sup 2} up to 150 mg/cm{sup 2}. Results: The Monte Carlo study showed that: (a) the x-ray beam becomes less penetrating after passing through dense breasts leading to higher values of zero-frequency DQE of the x-ray imaging converters and improved C{sub TH} values in all cases considered, (b) W/Rh target/filter combination results in improved C{sub TH} values at higher ESAK values, and (c) a-Se shows higher zero-frequency DQE values than the phosphor-based converters, Gd{sub 2}O{sub 2}S:Tb and CsI:Tl. However, thicker layers of CsI:Tl could be comparable to a-Se layers achieving approximately 27.6% C{sub TH} improvement at a thickness of 150 mg/cm{sup 2}. Conclusions: The present Monte Carlo investigation indicates that in the energy range employed in mammography, an upper limit, approximately 100 mg/cm{sup 2}, should be considered in the development of thicker a-Se converters. On the other hand, above this thickness value, CsI:Tl converter could improve its imaging performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Dwarf Galaxies Around NGC 55

In order to improve our understanding of the satellite populations of low-mass galaxies, the DECam Local Volume Exploration (DELVE) – DEEP Survey is performing a search for satellites around the isolated, low-mass galaxy, NGC 55. As part of this search, we characterize our dwarf galaxy detection sensitivity by injecting artificial dwarf galaxies into our data set and measuring the fraction that we can recover. Additionally, we inject and recover artificial dwarfs to test how the blending of resolved stars affects the detection of dwarf galaxies. We inject 650 artificial dwarfs across 26 DELVE-DEEP coadded images of the NGC 55 halo and use the software tool, Source Extractor, to perform source recovery. A dwarf-search pipeline is then run on our dwarf-injected catalogs, utilizing the photutils function, find peaks, and detections are recorded as a function of dwarf size and luminosity. Our results demonstrate that we are most sensitive to large, bright dwarf galaxies, and our sensitivity begins to decrease as we approach DELVE-DEEP’s detection limit or blending causes significant reductions in recovered magnitude. We also find that our results are hindered by the limitations of star-galaxy separation applied to distant, faint sources, which is possibly a consequence of the blending of small star clusters within dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAMS Update: Quarterly Report for October - December 2011

The Advanced Modeling and Simulation Office within the DOE Office of Nuclear Energy (NE) has been charged with revolutionizing the design tools used to build nuclear power plants during the next 10 years. To accomplish this, the DOE has brought together the national laboratories, U.S. universities, and the nuclear energy industry to establish the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program. The mission of NEAMS is to modernize computer modeling of nuclear energy systems and improve the fidelity and validity of modeling results using contemporary software environments and high-performance computers. NEAMS will create a set of engineering-level codes aimed at designing and analyzing the performance and safety of nuclear power plants and reactor fuels. The truly predictive nature of these codes will be achieved by modeling the governing phenomena at the spatial and temporal scales that dominate the behavior. These codes will be executed within a simulation environment that orchestrates code integration with respect to spatial meshing, computational resources, and execution to give the user a common 'look and feel' for setting up problems and displaying results. NEAMS is building upon a suite of existing simulation tools, including those developed by the federal Scientific Discovery through Advanced Computing and Advanced Simulation and Computing programs. NEAMS also draws upon existing simulation tools for materials and nuclear systems, although many of these are limited in terms of scale, applicability, and portability (their ability to be integrated into contemporary software and hardware architectures). NEAMS investments have directly and indirectly supported additional NE research and development programs, including those devoted to waste repositories, safeguarded separations systems, and long-term storage of used nuclear fuel. NEAMS is organized into two broad efforts, each comprising four elements. The quarterly highlights October-December 2011 are: (1) Version 1.0 of AMP, the fuel assembly performance code, was tested on the JAGUAR supercomputer and released on November 1, 2011, a detailed discussion of this new simulation tool is given; (2) A coolant sub-channel model and a preliminary UO{sub 2} smeared-cracking model were implemented in BISON, the single-pin fuel code, more information on how these models were developed and benchmarked is given; (3) The Object Kinetic Monte Carlo model was implemented to account for nucleation events in meso-scale simulations and a discussion of the significance of this advance is given; (4) The SHARP neutronics module, PROTEUS, was expanded to be applicable to all types of reactors, and a discussion of the importance of PROTEUS is given; (5) A plan has been finalized for integrating the high-fidelity, three-dimensional reactor code SHARP with both the systems-level code RELAP7 and the fuel assembly code AMP. This is a new initiative; (6) Work began to evaluate the applicability of AMP to the problem of dry storage of used fuel and to define a relevant problem to test the applicability; (7) A code to obtain phonon spectra from the force-constant matrix for a crystalline lattice has been completed. This important bridge between subcontinuum and continuum phenomena is discussed; (8) Benchmarking was begun on the meso-scale, finite-element fuels code MARMOT to validate its new variable splitting algorithm; (9) A very computationally demanding simulation of diffusion-driven nucleation of new microstructural features has been completed. An explanation of the difficulty of this simulation is given; (10) Experiments were conducted with deformed steel to validate a crystal plasticity finite-element code for bodycentered cubic iron; (11) The Capability Transfer Roadmap was completed and published as an internal laboratory technical report; (12) The AMP fuel assembly code input generator was integrated into the NEAMS Integrated Computational Environment (NiCE). More details on the planned NEAMS computing environment is given; and (13) The NEAMS program website (neams.energy.gov) is nearly ready to launch.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Profiling Production OpenSHMEM Applications, In: OpenSHMEM 2016: OpenSHMEM and Related Technologies. Enhancing OpenSHMEM for Hybrid Environments

Developing high performance OpenSHMEM applications routinely involves gaining a deeper understanding of software execution, yet there are numerous hurdles to gathering performance metrics in a production environment. Most OpenSHMEM performance profilers rely on the PSHMEM interface but PSHMEM is an optional and often unavailable feature. We present a tool that generates direct measurement performance profiles of OpenSHMEM applications even when PSHMEM is unavailable. The tool operates on dynamically linked and statically linked application binaries, does not require debugging symbols, and functions regardless of compiler optimization level. Integrated in the TAU Performance System, the tool uses automatically-generated wrapper libraries that intercept OpenSHMEM API calls to gather performance metrics with minimal overhead. Dynamically linked applications may use the tool without modifying the application binary in any way.

Computer Science↗

Geant4 Computing Performance Benchmarking and Monitoring

Performance evaluation and analysis of large scale computing applications is essential for optimal use of resources. As detector simulation is one of the most compute intensive tasks and Geant4 is the simulation toolkit most widely used in contemporary high energy physics (HEP) experiments, it is important to monitor Geant4 through its development cycle for changes in computing performance and to identify problems and opportunities for code improvements. All Geant4 development and public releases are being profiled with a set of applications that utilize different input event samples, physics parameters, and detector configurations. Results from multiple benchmarking runs are compared to previous public and development reference releases to monitor CPU and memory usage. Observed changes are evaluated and correlated with code modifications. Besides the full summary of call stack and memory footprint, a detailed call graph analysis is available to Geant4 developers for further analysis. The set of software tools used in the performance evaluation procedure, both in sequential and multi-threaded modes, include FAST, IgProf and Open|Speedshop. In conclusion, the scalability of the CPU time and memory performance in multi-threaded application is evaluated by measuring event throughput and memory gain as a function of the number of threads for selected event samples.

97 MATHEMATICS AND COMPUTING↗

Building and Sustaining a Community Resource for Best Practices in Scientific Software: The Story of BSSw.io

The development of scientific software—a cornerstone of long-term collaboration and scientific progress—parallels the development of other types of software but still poses distinct challenges, especially in high-performance computing. Although web searches yield numerous resources on software engineering, there is still a scarcity specifically for scientific software development. Here, this article introduces the Better Scientific Software site (https://bssw.io), a platform that hosts a community of researchers, developers, and practitioners who share their experiences and insights on scientific software development. Since 2017, this collaborative hub has gained traction within the scientific computing community, attracting a growing number of readers and contributors eager to share ideas and elevate their software development practices. In sharing the BSSw.io site’s story, we hope to encourage further growth of the BSSw.io community through both readership and contributors, with a long-term goal of fostering culture change by increasing emphasis on best practices in scientific software.

97 MATHEMATICS AND COMPUTING↗

Overcoming Challenges to Continuous Integration in HPC

Continuous integration (CI) has become a ubiquitous practice in modern software development, with major code hosting services offering free automation on popular platforms. CI offers major benefits, as it enables detecting bugs in code prior to committing changes. While high-performance computing (HPC) research relies heavily on software, HPC machines are not considered “common” platforms. This presents several challenges that hinder the adoption of CI in HPC environments, making it difficult to maintain bug-free HPC projects, and resulting in adverse effects on the research community. Here we explore the challenges that impede HPC CI, such as hardware diversity, security, isolation, administrative policies, and non-standard authentication, environments, and job submission mechanisms. We propose several solutions that could enhance the quality of HPC software and the experience of developers. Implementing these solutions would require significant changes at HPC centers, but if these changes are made, it would ultimately enable faster and better science.

97 MATHEMATICS AND COMPUTING↗

Assessment of potential advantages of relevant ions for particle therapy: A model based study

Purpose: Different ion types offer different physical and biological advantages for therapeutic applications. The purpose of this work is to assess the advantages of the most commonly used ions in particle therapy, i.e., carbon ({sup 12}C), helium ({sup 4}He), and protons ({sup 1}H) for different treatment scenarios. Methods: A treatment planning analysis based on idealized target geometries was performed using the treatment planning software TRiP98. For the prediction of the relative biological effectiveness (RBE) that is required for biological optimization in treatment planning the local effect model (LEM IV) was used. To compare the three ion types, the peak-to-entrance ratio (PER) was determined for the physical dose (PER{sub PHY} {sub S}), the RBE (PER{sub RBE}), and the RBE-weighted dose (PER{sub BIO}) resulting for different dose-levels, field configurations, and tissue types. Further, the dose contribution to artificial organs at risk (OAR) was assessed and a comparison of the dose distribution for the different ion types was performed for a patient with chordoma of the skull base. Results: The study showed that the advantages of the ions depend on the physical and biological properties and the interplay of both. In the case of protons, the consideration of a variable RBE instead of the clinically applied generic RBE of 1.1 indicates an advantage in terms of an increased PER{sub RBE} for the analyzed configurations. Due to the fact that protons show a somewhat better PER{sub PHY} {sub S} compared to helium and carbon ions whereas helium shows a higher PER{sub RBE} compared to protons, both protons and helium ions show a similar RBE-weighted dose distribution. Carbon ions show the largest variation of the PER{sub RBE} with tissue type and a benefit for radioresistant tumor types due to their higher LET. Furthermore, in the case of a two-field irradiation, an additional gain in terms of PER{sub BIO} is observed when using an orthogonal field configuration for carbon ions as compared to opposing fields. In contrast, for protons, the PER{sub BIO} is almost independent on the field configuration. Concerning the artificial lateral OAR, the volume receiving 20% of the prescribed RBE-weighted dose (V20) was reduced by over 35% using helium ions and by over 40% using carbon ions compared to protons. The analysis of the patient plan showed that protons, helium, and carbon ions are similar in terms of target coverage whereas the dose to the surrounding tissue is increasing from carbon ions toward protons. The mean dose to the brain stem can be reduced by more than 55% when using helium ions and by further 25% when using carbon ions instead of protons. Conclusions: The comparison of the PER{sub RBE} and PER{sub PHY} {sub S} of the three ion types suggests a strong dependence of the advantages of the three ions on the dose-level, tissue type, and field configuration. In terms of conformity, i.e., dose to the normal tissue, a clear gain is expected using carbon or helium ions compared to protons.

60 APPLIED LIFE SCIENCES↗

BMX: Biological modelling and interface exchange

Abstract High performance computing has a great potential to provide a range of significant benefits for investigating biological systems. These systems often present large modelling problems with many coupled subsystems, such as when studying colonies of bacteria cells. The aim to understand cell colonies has generated substantial interest as they can have strong economic and societal impacts through their roles in in industrial bioreactors and complex community structures, called biofilms, found in clinical settings. Investigating these communities through realistic models can rapidly exceed the capabilities of current serial software. Here, we introduce BMX, a software system developed for the high performance modelling of large cell communities by utilising GPU acceleration. BMX builds upon the AMRex adaptive mesh refinement package to efficiently model cell colony formation under realistic laboratory conditions. Using simple test scenarios with varying nutrient availability, we show that BMX is capable of correctly reproducing observed behavior of bacterial colonies on realistic time scales demonstrating a potential application of high performance computing to colony modelling. The open source software is available from the zenodo repository https://doi.org/10.5281/zenodo.8084270 under the BSD-2-Clause licence.

97 MATHEMATICS AND COMPUTING↗

pvlib python: 2023 project update

pvlib python is a community-developed, open-source software toolbox for simulating the performance of solar photovoltaic (PV) energy components and systems. It provides reference implementations of over 100 empirical and physics-based models from the peer-reviewed scientific literature, including solar position algorithms, irradiance models, thermal models, and PV electrical models. In addition to individual low-level model implementations, pvlib python provides high-level workflows that chain these models together like building blocks to form complete “weather-to-power” photovoltaic system models. It also provides functions to fetch and import a wide variety of weather datasets useful for PV modeling. pvlib python has been developed since 2013 and follows modern best practices for open-source python software, with comprehensive automated testing, standards-based packaging, and semantic versioning. Its source code is developed openly on GitHub and releases are distributed via the Python Package Index (PyPI) and the conda-forge repository. pvlib python’s source code is made freely available under the permissive BSD-3 license. Here we (the project’s core developers) present an update on pvlib python, describing capability and community development since our 2018 publication (Holmgren, Hansen, & Mikofski, 2018).

14 SOLAR ENERGY↗

WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples of imaging issues and recommended solutions will be discussed. TG-142 Imaging QA Simplified: Lessons From Diagnostic Physics Collaboration There are many commercial options for the performance of imaging quality assurance tests for the linear accelerator imaging systems as required by the AAPM TG-142 report. Imaging quality assurance testing is largely performed by the diagnostic physicist so routine performance of these tests by the practicing oncology physicist can be complicated and confusing given all of the commercially available options. This presentation focuses on the performance of imaging quality assurance testing for linear accelerators using methods similar to that of diagnostic physicists. This presentation will address the ability to perform the required testing without complicated software and explores solutions for the performance of these tests in an efficient manner while still maintaining the ability to ascertain image quality changes that may ultimately affect clinical decisions.

60 APPLIED LIFE SCIENCES↗