Search NASA⌕ Search

SEARCH · Search NASA

Results for “solvent effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Predicting Low Toxicity and Scalable Solvent Systems for High–Speed Roll–to–Roll Perovskite Manufacturing

Printed lead-based perovskite photovoltaics (PV) have gained interest due to their potential to be manufactured with scalable roll-to-roll techniques. In industrial scale-up, toxicity of inks can constrain roll-to-roll manufacturing due to the added cost of managing toxic effluents. Due to solvent toxicity, few perovskite solution chemistries in published works are scalable to gigawatt production capacity at low cost. Herein, it is shown that for scalable PV production, the use of aprotic polar solvents should be avoided due to their overall toxicity. Compliance with worldwide worker safety regulations for solvent exposure limits could require additional air handling requirements for some solvents, which in turn would affect cost-effectiveness. It is shown that costs associated with handling of hazardous substances can be significant and estimate an added cost of ¢3.7/W for dimethylformamide (DMF)-based inks. To solve this problem, a new perovskite ink solvent system is developed that is composed entirely of ether and alcohol, which has an effective exposure limit 14× higher than DMF, making it suitable for industrial coating processes. Here, it is shown that the new ink solvent system is capable of fabricating high-efficiency perovskite solar cells processed in 1 min on a standard roll-to-roll system.

36 MATERIALS SCIENCE↗

Controlling morphology and crystallite size of Cu(In{sub 0.7}Ga{sub 0.3})Se{sub 2} nano-crystals synthesized using a heating-up method

CuIn{sub 0.7}Ga{sub 0.3}Se{sub 2}(CIGS) nano-crystals were successfully synthesized via a heating-up process. The non-coordinating solvent (1-octadecene) and selenium/cations ratio effects on the crystalline phase and crystallite size of CIGS nano-crystallites were investigated. It was observed that the CIGS nano-crystallite morphology changed from sheet into spherical shape as the amount of 1-octadecene addition was increased. CIGS nano-crystals were obtained in 9–20 nm sizes as the selenium/cations ratio increased. These results suggest that the monomer reactivity in the solution can be adjusted by changing the solvent type and selenium/cations ratio, hence affecting the crystallite size and distribution. - Graphical abstract: CuIn{sub 0.7}Ga{sub 0.3}Se{sub 2}(CIGS) nano-crystals were successfully synthesized via a heating-up process in this study. The super-saturation in the solution can be adjusted by changing the OLA/ODE ratio and selenium/cation ratio.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Life of Pennzane and 815Z-Lubricated Instrument Bearings Cleaned with Non-CFC Solvents

This report takes the form of two papers: (1) "Life of Pennzane and 815Z-Lubricated Instrument Bearings cleaned with Non-CFC Solvents" and (2) a published paper, entitled "Instrument bearing life with NON-CFC cleaners". Abstract for paper # 1 : Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-1 13 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history. The second paper, which serves as an attachment, is abstracted below: Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-113 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history.

Loewenthal, Stuart↗

A Membrane Contactor Enabling Energy-Efficient CO 2 Capture from Point Sources with Deep Eutectic Solvents

We demonstrate a scalable and energy-efficient hollow fiber membrane contactor (HFMC)-based process using a green solvent for CO 2 capture. This process uses a deep eutectic solvent (DES) in an HFMC to provide close interfacial interactions and contact between the DES and CO 2 . This approach overcomes disadvantages associated with direct absorption in DES and could potentially be applied to a variety of solvent-based CO 2 capture methods. Commercial low-cost polymer hollow fiber membranes (e.g., microporous polypropylene) were evaluated for CO 2 capture with reline, a prototypical DES. Single-gas measurements showed that the DES-based polypropylene HFMC can capture and separate CO 2 while rejecting N2. From a mixed gas containing 50 mol % N 2 and 50 mol % CO ν , the DES-based HFMC separated CO 2 with a purity of 96.9 mol %. The effect of several process parameters including solvent flow rate, pressure, and temperature on the CO 2 separation performance was studied. The flux of the recovered CO 2 was 67.43 mmole/m 2 /h at a feed pressure of 4 bar. In situ Fourier transform infrared (FTIR) measurements combined with density functional theory (DFT)-based molecular dynamics simulations revealed that reline absorbs CO 2 by physical absorption without forming a new chemical compound, and CO 2 separation by reline occurs via the pressure swing mechanism. This research provides fundamental insights about physical solvent-based separation processes and a pathway toward practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic liquids: Promising green solvents for lignocellulosic biomass utilization

Ionic liquids are effective solvents/media for the utilization of lignocellulosic biomass. The unique properties of ionic liquids enable them to effectively dissolve and/or convert the biomass into various types of products. This review aims to cover the latest progress achieved in applications of ionic liquids on biomass conversion and analysis. Specifically, several recently developed approaches on how to overcome current challenges on the use of ionic liquids in the biomass conversion were highlighted. Here, recent studies addressing the potential applications of ionic liquids for the production of novel biomass-derived chemicals and materials were also discussed.

09 BIOMASS FUELS↗

Effects of chloride ions in acid-catalyzed biomass dehydration reactions in polar aprotic solvents

The utilization of polar aprotic solvents in acid-catalyzed biomass conversion reactions can lead to improved reaction rates and selectivities. We demonstrate that further increases in catalyst performance in polar aprotic solvents can be achieved through the addition of inorganic salts, specifically chlorides. Reaction kinetics studies of the Brønsted acid-catalyzed dehydration of fructose to hydroxymethylfurfural (HMF) show that the use of catalytic concentrations of chloride salts leads to a 10-fold increase in reactivity. Furthermore, increased HMF yields can be achieved using polar aprotic solvents mixed with chlorides. Ab initio molecular dynamics simulations (AIMD) show that highly localized negative charge on Cl– allows the chloride anion to more readily approach and stabilize the oxocarbenium ion that forms and the deprotonation transition state. High concentrations of polar aprotic solvents form local hydrophilic environments near the reactive hydroxyl group which stabilize both the proton and chloride anions and promote the dehydration of fructose.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Searching for low percolation thresholds within amphiphilic polymer membranes: The effect of side chain branching

Percolation thresholds for solvent diffusion within hydrated model polymeric membranes are derived from dissipative particle dynamics in combination with Monte Carlo (MC) tracer diffusion calculations. The polymer backbones are composed of hydrophobic A beads to which at regular intervals Y-shaped side chains are attached. Each side chain is composed of eight A beads and contains two identical branches that are each terminated with a pendant hydrophilic C bead. Four types of side chains are considered for which the two branches (each represented as [C], [AC], [AAC], or [AAAC]) are splitting off from the 8th, 6th, 4th, or 2nd A bead, respectively. Water diffusion through the phase separated water containing pore networks is deduced from MC tracer diffusion calculations. The percolation threshold for the architectures containing the [C] and [AC] branches is at a water volume fraction of ∼0.07 and 0.08, respectively. These are much lower than those derived earlier for linear architectures of various side chain length and side chain distributions. Control of side chain architecture is thus a very interesting design parameter to decrease the percolation threshold for solvent and proton transports within flexible amphiphilic polymer membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electro-reduction of organics on metal cathodes: A multiscale-modeling study of benzaldehyde on Au (111)

Here, we present a multiscale modeling study on the electro-reduction of benzaldehyde (BZY) on Au(111) under realistic electrochemical conditions. To model the electrochemical cell, we adopt a capacitor model in which complex solvents are confined between a Au cathode and a carbon anode. Classical molecular dynamics simulations reveal that electrode charge density and the presence of alcohol show strong effects on the density, adsorption geometry and dynamics of benzaldehyde on the Au electrode. Under charging conditions, the surface concentration of benzaldehyde on the Au electrode decreases, while the content of other species increases. Finally, we proposed a scheme that correlates the electric current running through the Au/solvent interface with the applied bias. This study provides a molecular level understanding of how solvent composition, in this case water/alcohol content, controls the activity of electrocatalytic hydrogenation

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the acoustic cavitation in ionic liquids in a horn-type ultrasound reactor

Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent’s thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets – 0.77cm 3 and 24.4ms -1 for 1-ethyl-3-methylimidazolium chloride at 60W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u – 0.17cm 3 and 1.7ms -1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20W. Sonochemiluminescence experiments validated the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Formation of Solvent-Shared Ion Pairs in Aqueous Calcium Perchlorate Solution toward Saturated Concentration or Deep Supercooling Temperature and Its Effects on the Water Structure

As a candidate of Martian salts, calcium perchlorate [Ca(ClO 4 ) 2 ] has the potential to stabilize liquid water on the Martian surface because of its hygroscopicity and low freezing temperature when forming aqueous solution. These two properties of electrolytes in general have been suggested to result from the specific cation–anion–water interaction (ion pairing) that interrupts the structure of solvent water. To investigate how this concentration-dependent and temperature-dependent ion pairing process in aqueous Ca(ClO 4 ) 2 solution leads to its high hygroscopic property and the extreme low eutectic temperature, we have conducted two sets of experiments. First, the effects of concentration on aqueous calcium perchlorate from 3 to 7.86 m on ion pairing were investigated using Raman spectroscopy. Deconvolution of the Raman symmetric stretching band (ν 1 ) of ClO 4 – showed the enhanced formation of solvent-shared ion pairs upon increasing salt concentration at room temperature. We have confirmed that the low tendency of forming contact ion pairs in concentrated solution contributes to the high hygroscopicity of the salt. Second, the near eutectic samples were studied as a function of temperature by both combined differential scanning calorimetry–Raman spectroscopic experiments and in situ X-ray diffraction. The number of solvent-shared ion pairs was found to increase with decreasing temperature when cooled below the temperature of maximum density of the solution, driven by a change in water toward an ice-like structure in the supercooled regime. The massive presence of solvent-shared ion pairs in turn limits the development of the long-range order in the tetrahedral networks of water molecules, which is responsible for the extremely low eutectic point and deep supercooling effects observed in the Ca(ClO 4 ) 2 –H 2 O system.

54 ENVIRONMENTAL SCIENCES↗

Next Generation Solvent Performance in the Modular Caustic Side Solvent Extraction Process - 15495

Changes to the Modular Caustic Side Solvent Extraction Unit (MCU) flow-sheet were implemented in the facility. Implementation included changing the scrub and strip chemicals and concentrations, modifying the O/A ratios for the strip, scrub, and extraction contactor banks, and blending the current BoBCalixC6 extractant-based solvent in MCU with clean MaxCalix extractant-based solvent. During the successful demonstration period, the MCU process was subject to rigorous oversight to ensure hydraulic stability and chemical/radionuclide analysis of the key process tanks (caustic wash tank, solvent hold tank, strip effluent hold tank, and decontaminated salt solution hold tank) to evaluate solvent carryover to downstream facilities and the effectiveness of cesium removal from the liquid salt waste. Results indicated the extraction of cesium was significantly more effective with an average Decontamination Factor (DF) of 1,129 (range was 107 to 1,824) and that stripping was effective. The contactor hydraulic performance was stable and satisfactory, as indicated by contactor vibration, contactor rotational speed, and flow stability; all of which remained at or near target values. Furthermore, the Solvent Hold Tank (SHT) level and specific gravity was as expected, indicating that solvent integrity and organic hydraulic stability were maintained. The coalescer performances were in the range of processing results under the BOBCalixC6 flow sheet, indicating negligible adverse impact of NGS deployment. After the Demonstration period, MCU began processing via routine operations. Results to date reiterate the enhanced cesium extraction and stripping capability of the Next Generation Solvent (NGS) flow sheet. This paper presents process performance results of the NGS Demonstration and continued operations of MCU utilizing the blended BobCalixC6-MaxCalix solvent under the NGS flowsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next generation solvent performance in the modular caustic side solvent extraction process - 15495

Changes to the Modular Caustic Side Solvent Extraction Unit (MCU) flow-sheet were implemented in the facility. Implementation included changing the scrub and strip chemicals and concentrations, modifying the O/A ratios for the strip, scrub, and extraction contactor banks, and blending the current BoBCalixC6 extractant based solvent in MCU with clean MaxCalix extractant based solvent. During the successful demonstration period, the MCU process was subject to rigorous oversight to ensure hydraulic stability and chemical/radionuclide analysis of the key process tanks (caustic wash tank, solvent hold tank, strip effluent hold tank, and decontaminated salt solution hold tank) to evaluate solvent carryover to downstream facilities and the effectiveness of cesium removal from the liquid salt waste. Results indicated the extraction of cesium was significantly more effective with an average Decontamination Factor (DF) of 1,129 (range was 107 to 1,824) and that stripping was effective. The contactor hydraulic performance was stable and satisfactory, as indicated by contactor vibration, contactor rotational speed, and flow stability; all of which remained at or near target values. Furthermore, the Solvent Hold Tank (SHT) level and specific gravity was as expected, indicating that solvent integrity and organic hydraulic stability were maintained. The coalescer performances were in the range of processing results under the BOBCalixC6 flow sheet, indicating negligible adverse impact of NGS deployment. After the Demonstration period, MCU began processing via routine operations. Results to date reiterate the enhanced cesium extraction and stripping capability of the Next Generation Solvent (NGS) flow sheet. This paper presents process performance results of the NGS Demonstration and continued operations of MCU utilizing the blended BobCalixC6-MaxCalix solvent under the NGS flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aprotic Electrolytes in Li-Air Batteries.

Compared to Li-ion batteries, the Li–air battery is a relatively new concept and much of its problems remain to be solved. One of the key problems is the stability of the electrolytes, which is the subject of this chapter in which we review experimental and computational studies on this subject. The electrolyte stability is of concern during both charge and discharge at both the cathode and anode. In addition to electrochemical reactions, there can also be chemical reactions on the surfaces not directly involving electron transfer. Most experimental and computational studies so far have focused on the stability of solvents during charge and discharge at the cathode. Although there is strong evidence that the carbonates are decomposing at the cathode to form solid products such as Li2CO3, it is still not yet completely clear how the reduced O2 species are directly related to the decomposition mechanism. Recent experimental and computational work has focused on the stability of ether-based electrolytes. Ether-based electrolytes have been found to have increased stability for oxygen reduction products during discharge as most studies do not see evidence for solid decomposition products. However, ethers still have stability issues arising from other decomposition mechanisms such as oxidation during charge and chemical decomposition on the lithium oxide surfaces. In addition, decomposition reactions may occur at the anode, involving an oxygen crossover effect. Meanwhile, independent of whether the solvent decomposition reaction proceeds via O22−, LiO2, or another Li–air reactive species, it is now clear that a solvent that is resistant to attack by reduced O2 species must be discovered in order to achieve a practical Li–air cell with a long cycle life. Besides the problems of solvent electrochemical stability, the electrochemical selectivity also has to be resolved.

Lau, Kah Chun↗

Microscopic Behaviors of Tri-n-Butyl Phosphate, n-Dodecane and Their Mixtures at Air/Liquid and Liquid/Liquid Interfaces: An AMBER Polarizable Force Field Study

In solvent extraction processes for recovering metal ions from used nuclear fuel, as well as other industrial applications, a better understanding of the metal complex phase transfer phenomenon would greatly aid ligand design and process optimization. We have approached this challenge by utilizing classical molecular dynamics simulations technique to gain visual appreciation of the vapor/liquid and liquid/liquid interface between tri-n-butyl phosphate (TBP) and n-dodecane with air and water. In this study, we successfully reparameterized polarizable force fields for TBP and n-dodecane that accurately reproduced several of their thermophysical properties such as: density, heat of vaporization, and dipole moment. Our models were able to predict the surface and interfacial tension of different systems when compared to experimental results also performed by us. Through this study, we gained numerous atomistic understanding of the behaviors of TBP and n-dodecane at the interface against air and water, useful in further computational studies of such systems. Lastly, our studies indicate that the initial configuration of a simulation may have a large effect on the final result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water-Mediated Heterogeneously Catalyzed Reactions

Nature takes advantage of the pervasive presence of water to control many enzymatic reactions by utilizing the unique properties of water, which in turn help regulating reaction rates, selectivity, and rates of mass transfer. Some of the natural phenomena in which water plays the role of solvent, reactant, or byproduct find parallels in industrially relevant reactions catalyzed by synthetic heterogeneous catalysts. Here, we address different mechanistic features of catalytic reactions influenced by water. They include modification of reactant (or product) solubility and rate of mass transport; stabilization of reactants, products, and transition states, both in open and confined spaces; and direct participation in the catalytic phenomenon by remote bond polarization, H-shuttling, or acting as a cocatalyst.

Cooperative catalysis↗

Impact of Dispersion Solvent on Ionomer Thin Films and Membranes

Perfluorosulfonic acid (PFSA) ionomers are an important class of materials that many electrochemical devices rely on as their ion-conducting electrolyte. Often, PFSA films are prepared through solution-processing techniques. Previous research has demonstrated that the solvent environment affects PFSA dispersion conformation, but it is not clear to what extent (if at all) these conformational effects persist for thin films and membranes upon casting, nor how dispersion solvent impacts film formation during the drying process. Here in this paper, we explore these questions by systematically examining the effect of Thin Film all length scales affected by dispersion solvent water and n-propanol mixtures on PFSA thin-film formation and structure, membrane structure, and resulting properties. Using a combination of in situ, time-resolved grazing incidence X-ray scattering and tender wide-angle X-ray scattering, it is shown that films prepared from high-water-concentration dispersions exhibit stronger interactions and arrangement upon drying, and possess larger network domain sizes than those prepared from low-water-concentration dispersions. These stronger interactions likely manifest in greater network connectivity, as evidenced by enhanced conductivity for membranes and decreased water uptake for thin films. Significantly, these solvent-induced differences persist even after thermal annealing. It is clear that the dispersion solvent choice is a critical parameter controlling PFSA nano- and mesoscale structure and presents an important dial with which to direct PFSA macroscale properties.

36 MATERIALS SCIENCE↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Energy relaxation of a dissipative quantum oscillator

The dissipative harmonic oscillator is studied as a model for vibrational relaxation in a liquid environment. Continuum limit expressions are derived for the time-dependent average energy, average width of the population, and the vibrational population itself. The effect of the magnitude of the solute-solvent interaction, expressed in terms of a friction coefficient, solvent temperature, and initial energy of the oscillator on the relaxation has been studied. These results shed light on the recent femtosecond stimulated Raman scattering probe of the 1570 cm{sup −1} −C=C− stretching mode of trans-Stilbene in the first (S{sub 1}) excited electronic state. When the oscillator is initially cold with respect to the bath temperature, its average energy and width increase in time. When it is initially hot, the average energy and width decrease with time in qualitative agreement with the experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗