Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes: Public Version

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. In preparation for testing of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The results of those analyses formed the basis of the test matrix. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. Together these comprise a one-dimensional icing tool. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method was enhanced by computing key parameters through the fan-stator at multiple spanwise locations, in order to increase the fidelity with the current mean-line method. In addition, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion near the splitter-lip and shroud. Since there were no thermocouples near the splitter, a simple order of magnitude heat transfer model was implemented to estimate the wall temperature. Future analyses will require a higher fidelity thermal analysis of the compression system metal walls to accurately calculate the total heat flux to the ice particle. For many data points analyzed, there were differences between the thermodynamic system model and the measured test data that may partially be responsible for uncertainties with the results of the current analyses.

Turbomachinery↗

Space-qualified Chalcogenide Materials through ISS MISSE Exposure —From Property to Application

In March 2021, twenty-four samples of various phase change materials (PCMs - Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2Se3) along with metasurface optical components comprised of these PCMs, were delivered to the International Space Station (ISS) as part of the Materials International Space Station Experiment (MISSE-14) test campaign [1]. Although PCMs have previously been noted for their resilience to various forms of radiation [2], they had not been tested in a realistic space environment until this exposure campaign with joint NASA and MIT collaboration. During the six-month total open exposure time in low earth orbit (LEO), high-resolution cameras scanned and captured photographs of the samples to detect changes as a function of time along with on-orbit measured temperature, UV radiation, total atomic oxygen fluence, and total ionizing radiation doses. The samples were returned to NASA Langley Research Center in March 2022 for post-flight characterization. This duplicated the preflight characterization (i.e., material composition and crystallinity that limits switching speed, index contrast, loss, etc.) conducted before launch. The space sector has witnessed tremendous growth within the past decade—not only from government agencies but also entrants from the private sector. Future growth in the capabilities of Earth observation, deep space, and planetary surface missions using miniaturized spacecraft platforms can only be sustained by innovations in the design of remote sensors and other sub-systems. Active metasurface optics with enhanced tunability and reconfigurability continues to redefine the boundaries of optical science [3]. The introduction of PCM technology and associated optical devices will help to accelerate the adoption of new architectures for reduced size, weight, power, and cost (SWaP-C) platforms in space.Here we introduce results obtained from the MISSE-14 mission related to space qualification of PCM-based optic devices and constituent materials. We then discuss our recent work developing active integrated photonic devices and metasurface optics based on PCMs for space applications. This includes tunable and reconfigurable optical metasurface devices to support NASA space communication and LIDAR applications. PCMs are quickly becoming interesting photonics materials but questions related to mission suitability remain, particularly in regard to key properties like figures-of-merit (FOM, Δn/Δk), glass forming temperatures, and phase transition speeds. This talk will describe efforts to afford researchers the ability to have access to cost-effective data on exposure-induced changes to PCM fundamental physical and optical properties to assess their utility for space applications. The MISSE-14 sample exposure campaign allows a complete understanding of the limitations of the PCMs for various space-based electronic and optoelectronic applications.

Chalcogenide Phase change material↗

The spectra of Orion A and IRC + 10216 between 72.2 and 91.1 GHz

Spectral scans of Orion A and the envelope of IRC + 10216, obtained with resolution 1 MHz over the complete range from 72.2 to 91.1 GHz using the radome-enclosed 20-m mm-wave telescope at Onsala Space Observatory during 1979-1982, are presented graphically (as main-beam brightness temperature in 500-MHz bands), providing the data basis is for the discussion of Johansson et al. (1984). Observing parameters include main-beam efficiency 0.58, aperture efficiency 0.44, FHPBW 47 arcsec, and total-system noise temperature 300-500 K.

Johansson, L. E. B.↗

Passive Safety Features Evaluation of KIPT Neutron Source Facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine and its commissioning process is underway. It will be used to conduct basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The facility has an electron accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100 MeV electrons. Tungsten or natural uranium is the target material for generating neutrons driving the subcritical assembly. The subcritical assembly is composed of WWR-M2 - Russian fuel assemblies with U-235 enrichment of 19.7 wt%, surrounded by beryllium reflector assembles and graphite blocks. The subcritical assembly is seated in a water tank, which is a part of the primary cooling loop. During normal operation, the water coolant operates at room temperature and the total facility power is ~300 KW. The passive safety features of the facility are discussed in in this study. Monte Carlo computer code MCNPX was utilized in the analyses with ENDF/B-VII.0 nuclear data libraries. Negative reactivity temperature feedback was consistently observed, which is important for the facility safety performance. Due to the design of WWR-M2 fuel assemblies, slight water temperature increase and the corresponding water density decrease produce large reactivity drop, which offset the reactivity gain by mistakenly loading an additional fuel assembly. The increase of fuel temperature also causes sufficiently large reactivity decrease. This enhances the facility safety performance because fuel temperature increase provides prompt negative reactivity feedback. The reactivity variation due to an empty fuel position filled by water during the fuel loading process is examined. Also, the loading mistakes of removing beryllium reflector assemblies and replacing them with dummy assemblies were analyzed. In all these circumstances, the reactivity change results do not cause any safety concerns.

43 PARTICLE ACCELERATORS↗

Pollutant formation in fuel lean recirculating flows

An opposed reacting jet combustor (ORJ) was tested at a pressure of 1 atmosphere. A premixed propane/air stream was stabilized by a counterflowing jet of the same reactants. The resulting intensely mixed zone of partially reacted combustion products produced stable combustion at equivalence ratios as low as 0.45. Measurements are presented for main stream velocities of 7.74 and 13.6 m/sec with an opposed jet velocity of 96 m/sec, inlet air temperatures from 300 to 600 K, and equivalence ratios from 0.45 to 0.625. Fuel lean premixed combustion was an effective method of achieving low NOx emissions and high combustion efficiencies simultaneously. Under conditions promoting lower flame temperature, NO2 constituted up to 100 percent of the total NOx. At higher temperatures this percentage decreased to a minimum of 50 percent.

Schefer, R. W.↗

A measurable Lawson criterion and hydro-equivalent curves for inertial confinement fusion

It is shown that the ignition condition (Lawson criterion) for inertial confinement fusion (ICF) can be cast in a form dependent on the only two parameters of the compressed fuel assembly that can be measured with existing techniques: the hot spot ion temperature (T{sub i}{sup h}) and the total areal density ({rho}R{sub tot}), which includes the cold shell contribution. A marginal ignition curve is derived in the {rho}R{sub tot}, T{sub i}{sup h} plane and current implosion experiments are compared with the ignition curve. On this plane, hydrodynamic equivalent curves show how a given implosion would perform with respect to the ignition condition when scaled up in the laser-driver energy. For 3<<T{sub i}{sup h}>{sub n}<6 keV, an approximate form of the ignition condition (typical of laser-driven ICF) is <T{sub i}{sup h}>{sub n}{sup 2.6}{center_dot}<{rho}R{sub tot}>{sub n}>50 keV{sup 2.6}{center_dot} g/cm{sup 2}, where <{rho}R{sub tot}>{sub n} and <T{sub i}{sup h}>{sub n} are the burn-averaged total areal density and hot spot ion temperature, respectively. Both quantities are calculated without accounting for the alpha-particle energy deposition. Such a criterion can be used to determine how surrogate D{sub 2} and subignited DT target implosions perform with respect to the one-dimensional ignition threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A quantitative study of retention and release of deuterium and tritium during irradiation of y-LiAlO2 pellets

This study reports on the quantification of deuterium in ion-irradiated gamma-LiAlO2 pellets as a function of dose and temperature. The gamma-LiAlO2 pellets were sequentially irradiated with He+ and D2+ ions to the same fluences of 5E16, 1E17 and 2E17 He++D+/cm2 at 188 K. Additional irradiation was performed to 1E17, 2E17 and 4E17 He++D+/cm2 at 573 K. A set of the pellets irradiated at 188 K was shipped and stored at low temperatures from 80 to 132 K and characterized using time-of-flight secondary ion mass spectrometry at ~173 K. The deuterium depth profiles show a Gaussian-like distribution in the low-temperature pellets. The total deuterium retention is found to be directly proportional to the ion fluence. About 27 at.% of the implanted deuterium atoms were released from the pellet irradiated to 2E17 He++D+/cm2 at 188 K during storage at room temperature for ~1 month. Retention of the trapped or bound deuterium during ion irradiation at 573 K increases initially with ion fluence and tends to saturate at a high fluence. The amount of the released deuterium is observed to be quantitatively consistent with that of the released tritium from similar standard pellets during neutron irradiation at 573 K.

Deuterium retention and release, ion irradiation, ↗

Structure and Origins of Trends in Hydrological Measures over the western United States

This study examines, at 1/8 degree spatial resolution, the geographic structure of observed trends in key hydrologically relevant variables across the western United States (U.S.) over the period 1950-1999, and investigates whether these trends are statistically significantly different from trends associated with natural climate variations. A number of variables were analyzed, including late winter and spring temperature, winter-total snowy days as a fraction of winter-total wet days, 1st April Snow Water Equivalent (SWE) as a fraction of October through March precipitation total (P{sub ONDJFM}), and seasonal (January-February-March; JFM) accumulated runoff as a fraction of water year accumulated runoff. The observed changes were compared to natural internal climate variability simulated by an 850-year control run of the CCSM3-FV climate model, statistically downscaled to a 1/8 degree grid using the method of Constructed Analogues. Both observed and downscaled temperature and precipitation data were then used to drive the Variable Infiltration Capacity (VIC) hydrological model to obtain the hydrological variables analyzed in this study. Large trends (magnitudes found less than 5% of the time in the long control run) are common in the observations, and occupy substantial part of the area (37-42%) over the mountainous western U.S. These trends are strongly related to the large scale warming that appears over 89% of the domain. The strongest changes in the hydrologic variables, unlikely to be associated with natural variability alone, have occurred at medium elevations (750 m to 2500 m for JFM runoff fractions and 500 m-3000 m for SWE/PONDJFM) where warming has pushed temperatures from slightly below to slightly above freezing. Further analysis using the data on selected catchments across the simulation domain indicated that hydroclimatic variables must have changed significantly (at 95% confidence level) over at least 45% of the total catchment area to achieve a detectable trend in measures accumulated to the catchment scale.

54 ENVIRONMENTAL SCIENCES↗

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0&deg;C down to -26 to -29&deg;C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de C&oacute;rdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20&deg;C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 &micro;m-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33&deg;C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95&deg;C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95&deg;C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O&rsquo;Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196&ndash;6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402&ndash;409.

54 ENVIRONMENTAL SCIENCES↗

MASSIVE QUIESCENT CORES IN ORION: DYNAMICAL STATE REVEALED BY HIGH-RESOLUTION AMMONIA MAPS

We present combined Very Large Array and Green Bank Telescope images of NH{sub 3} inversion transitions (1, 1) and (2, 2) toward OMC2 and OMC3. We focus on the relatively quiescent Orion cores, which are away from the Trapezium cluster and have no sign of massive protostars or evolved star formation. The 5'' angular resolution and 0.6 km s{sup -1} velocity resolution enable us to study the thermal and dynamic state of these cores at {approx}0.02 pc scales, comparable to or smaller than those of the current dust continuum surveys. We measure temperatures for a total of 30 cores, with average masses of 11 M{sub Sun }, radii of 0.039 pc, virial mass ratio R{sub vir}-bar = 3.9, and critical mass ratio R{sub C}-bar = 1.5. Twelve sources contain Spitzer protostars. The thus defined starless and protostellar subsamples have similar temperature, line width, but different masses, with an average of 7.3 M{sub Sun} for the former and 16 M{sub Sun} for the latter. Compared to other Gould Belt dense cores, more Orion cores have a high gravitational-to-kinetic energy ratio and more cores have a larger than unity critical mass ratio. Orion dense cores have velocity dispersions similar to those of cores in low-mass star-forming regions but larger masses for given size. Some cores appear to have truly supercritical gravitational-to-kinetic energy ratios, even when considering significant observational uncertainties: thermal and non-thermal gas motions alone cannot prevent collapse.

79 ASTRONOMY AND ASTROPHYSICS↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stratus: An interactive steady state mixed layer model for personal computers

A steady-state, horizontally homogeneous, cloud-topped marine boundary layer model based primarily on the work of Lilly (1968) and Schubert et al., (1979) is presented. The conservative thermodynamic variables are equivalent potential temperature, theta(sub e), and total water mixing ratio, q + l. Some of the differences between this and Lilly's (1968) model are: radiation is allowed to penetrate into the boundary layer; cloud top values of longwave radiation, equivalent potential temperature, and water vapor mixing ratio are linear functions of height derived from climatological data at California coastal stations; and the closure assumption assumes a weighted average of Lilly's (1968) maximum and minimum entrainment theories. This model was programmed in FORTRAN and will run interactively on an IBM-compatible personal computer. The program allows the user to specify the geographical location, the wind speed, the sea-surface temperature, the large scale horizontal divergence, and the initial guess for cloud top height. Output includes the steady state values of cloud top and cloud base height, mixed layer equivalent potential temperature and total water mixing ratio, and the associated convective and radiative fluxes.

Guinn, Thomas A.↗

Total Hemispherical Emissivity of Metals Applicable to Radiant Heat Testing

Total hemispherical emissivities are a commonly used property in radiative heat transfer analysis. Measurements made in the course of testing become far more useful to thermal analysts if they are compiled with a sufficient level of detail, and summarized in a manner that allows the most appropriate value or trend to be located quickly. This report collects emissivity measurements from recent years, made in the course of testing metallic surfaces at Sandia's Radiant Heat Test Facility, and compares them to a selection of previous summary documents. These measurements are organized by material type, surface finish, and degree of oxidation. The comparisons also consider the temperature dependence of total hemispherical emissivity. Materials considered include Inconel 600, SS304, 17-4PH SS, silicon carbide, and aluminum alloys. A limited selection of high-temperature paints and other surface coatings are also considered. Recommendations are made for frequency of measurements and level of detail in reporting emissivities in future test series. A more limited scope is recommended for the use of high-temperature paints at Sandia's Radiant Heat Test Facility; pre-oxidation of Inconel and stainless steel surfaces is preferred in many circumstances.

36 MATERIALS SCIENCE↗