SEARCH · Search NASA
Results for “trace elements”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Improving the Representation of Soluble Iron in Climate Models
Mineral dust produced in the arid and semi-arid regions of the world is the dominant source of iron (Fe) in atmospheric aerosol inputs to the open ocean. The bioavailable Fe fraction of atmospheric dust is thought to regulate and occasionally limit the primary productivity in large oceanic regions, which influences the CO2 uptake from the atmosphere affecting the Earth’s climate. Because Fe bioavailability cannot be directly measured, it is assumed that the dissolved Fe or highly reactive Fe in the dust is bioavailable. The fraction of soluble Fe in dust is mainly controlled by: (1) the mineral composition of the soils and the emitted dust from the source areas; (2) the atmospheric processing that converts the Fe in Fe-bearing minerals into highly soluble forms of Fe. The project has mainly focused on constraining the mineral composition of dust aerosols (1), a previously neglected, yet a key issue to constrain the deposition of soluble iron. Deriving aerosol mineral composition requires global knowledge of the soil mineral content, which is available from poorly constrained global atlases. In addition, the mineral content of the emitted aerosol differs from that of the parent soil. Measurements of soil mineral fractions are based upon wet sedimentation (or ’wet sieving’) techniques that disturb the soil sample, breaking aggregates that are found in the original, undispersed soil that is subject to wind erosion. Wet sieving alters the soil size distribution, replacing aggregates that are potentially mobilized as aerosols with a collection of smaller particles. A major challenge is to derive the size-distributed mineral fractions of the emitted dust based upon their fractions measured from wet-sieved soils. Finally, representations of dust mineral composition need to account for mixtures of minerals. Examination of individual particles shows that iron, an element that is central to many climate processes, is often found as trace impurities of iron oxide attached to aggregates of other minerals. This is another challenge that has been tackled by the project. The project has produced a major step forward on our understanding of the key processes needed to predict the mineral composition of dust aerosols by connecting theory, modeling and observations. The project has produced novel semi-empirical and theoretical methods to estimate the emitted size distribution and mineral composition of dust aerosols. These methods account for soil aggregates that are potentially emitted from the original undisturbed soil but are destroyed during wet sieving. The methods construct the emitted size distribution of individual minerals building upon brittle fragmentation theory, reconstructions of wet-sieved soil mineral size distributions, and/or characteristic mineral size distributions estimated from observations at times of high concentration. Based on an unprecedented evaluation with a new global compilation of observations produced with the project support, we showed that the new methods remedy some key deficiencies compared to the previous state-of-the-art. This includes the correct representation of Fe-bearing phyllosilicates at silt sizes, where they are abundant according to observations. In addition, the quartz fraction of silt particles is in better agreement with measured values. In addition, we represent an additional class of iron oxide aerosol that is a small impurity embedded within other minerals, allowing it to travel farther than in its pure crystalline state. We assume that these impurities are least frequent in soils rich in iron oxides (as a result of the assumed effect of weathering that creates pure iron oxide crystals). The mineral composition of dust is also important to other interaction with climate - through shortwave absorption and radiative forcing, nucleation of cloud droplets and ice crystals, and the heterogeneous formation of sulfates and nitrates - and to its impacts upon human health. Despite the importance of mineral composition, models have typically assumed that soil dust aerosols have globally uniform composition. The results of this project will allow an improved estimation of the dust effects upon climate and health.
A MULTIPHASE ABSORBER CONTAINING O VI AND BROAD H I DIRECTLY TRACING 10{sup 6} K PLASMA AT LOW REDSHIFT TOWARD HE 0153-4520
Observations of the QSO HE 0153-4520 (z{sub em} = 0.450) with the Cosmic Origins Spectrograph (COS) from 1134 to 1796 A with a resolution of {approx}17 km s{sup -1} and a signal-to-noise ratio per resolution element of 20-40 are used to study a multiphase partial Lyman limit system (LLS) at z = 0.22601 tracing both cool and hot gas. Far-Ultraviolet Spectroscopic Explorer observations of the Lyman limit break yield log N(H I) = 16.61 (0.12, -0.17). The observed UV absorption lines of H I {lambda}{lambda}1216 to 926, C III, C II, N III, N II, Si III, and Si II imply the existence of cool photoionized gas in the LLS with log U = -2.8 {+-} 0.1 and log N(H) = 19.35 {+-} 0.18, log n{sub H} = -2.9 {+-} 0.2, log T = 4.27 {+-} 0.02, log (P/k) = 1.75 {+-} 0.17, and log L (kpc) = 0.70 {+-} 0.25. The abundances are [X/H] = -0.8 (+0.3, -0.2) for N, Si, and C, but the result is sensitive to the assumed shape of the ionizing background radiation field. The multiphase system has strong O VI and associated broad Ly{alpha} absorption (BLA) with log N(O VI) = 14.21 {+-} 0.02, b(O VI) = 37 {+-} 1 km s{sup -1}, log N(H I) = 13.70 (+0.05, -0.08), b(H I) = 140 (+14, -16) km s{sup -1} and b(H I)/b(O VI) = 3.9 {+-} 0.4. The O VI does not arise in the cool photoionized gas of the LLS. The O VI and BLA imply the direct detection of thermally broadened absorption by hot gas with log T = 6.07 (+0.09, -0.12), [O/H] = -0.28 (+0.09, -0.08), and log N(H) = 20.41 (+0.13, -0.17). The absorber probably occurs in the circumgalactic environment (halo) of a foreground galaxy. The very high sensitivity of UV absorption line spectroscopy to O VI and thermally broadened H I Ly{alpha} now permits the direct detection of hot gas with log T > 6, a determination of the abundance of O/H, and log N(H) in low-redshift intergalactic medium absorption line systems.
In situ liquid SIMS analysis of uranium oxide
Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.
Laser Resonance Ionization Spectroscopy of the Lanthanides Tb, Dy and Ho as Homologues to Actinides and Super Heavy Elements
Spectroscopic investigations of the rare earth elements Tb, Dy and Ho have been carried out using laser resonance ionization mass spectroscopy. A variety of new intermediate energy levels and autoionizing states were observed in these elements. Efficient and selective excitation and ionization schemes for the elements have been developed for Ti:Sapphire lasers using the spectroscopic data. Resonant ionization schemes for Np were also been studied as the preparation work for related investigations on actinide elements and for the spectroscopy on the heaviest elements, where spectroscopic data so far are scarce or not existing at all.
Quantitative imaging of trace B in Si and SiO{sub 2} using ToF-SIMS
Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.
The Origin of the Elements
The world around us is made of atoms. Did you ever wonder where these atoms came from? How was the gold in our jewelry, the carbon in our bodies, and the iron in our cars made? In this lecture, we will trace the origin of a gold atom from the Big Bang to the present day, and beyond. You will learn how the elements were forged in the nuclear furnaces inside stars, and how, when they die, these massive stars spread the elements into space. You will learn about the origin of the building blocks of matter in the Big Bang, and we will speculate on the future of the atoms around us today.
Measurement of Total, Elemental, and Methyl Mercury in Hanford Tank Waste: Technology Transfer from PNNL to Hanford 222-S Laboratory
This report describes the chemical separations used to measure the amount and chemical form of mercury in Hanford tank waste and provides the technical basis and recommendations for transferring and implementing this new ultra-trace mercury analytical technique at Hanford’s 222-S Laboratory. In the Hanford tank waste, mercury can exist as either elemental, inorganic, or organic mercury species. Of key interest is understanding the quantification and speciation of total (elemental + inorganic + organic), elemental, and organic (assumed to be only methyl mercury) mercury. The tanks may also have other organic mercury species, but their direct measurement is outside the scope of this report.
Selective Isotope Determination of Uranium using HR-RIMS
The detection of lowest abundances of the ultra trace isotope {sup 236}U in environmental samples requires an efficient detection method which allows a high elemental and isotopic selectivity to suppress neighbouring isotopes of the same element and other background. High Resolution Laser Resonance Ionization Mass Spectrometry (HR-RIMS) uses the individual electron structure of each isotope to provide an outstanding element and isotope selective ionization.
Recovery of Rare Earths, Precious Metals and Other Critical Materials from Geothermal Waters with Advanced Sorbent Structures
The work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials demonstrated high performance for collection of trace REEs, precious and valuable metals. The nanostructured materials typically performed better than commercially available sorbents. Data contains organic and inorganic sorbent removal efficiency, Sharkey Hot Springs (Idaho) water chemsitry analysis, and rare earth removal efficiency from select sorbents.
Optimization of a phase-space beam position and size monitor for low-emittance light sources
The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K -edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.
Another solution of 2D Ising model
The partition function of the Ising model on a two-dimensional regular lattice is calculated by using the matrix representation of a Clifford algebra (the Dirac algebra), with number of generators equal to the number of lattice sites. It is shown that the partition function over all loops in a 2D lattice including self-intersecting ones is the trace of a polynomial in terms of Dirac matrices. The polynomial is an element of the rotation group in the spinor representation. Thus, the partition function is a function of a character on an orthogonal group of a high degree in the spinor representation.
Aged and unaged pine wood pyrogenic organic matter: mineralization, elemental analysis and spectroscopy data (February 2020)
In this study, we used a pyrogenic organic matter (PyOM) degrading Streptomyces isolate – a globally common soil bacterium – to investigate the effects of physical (freeze-thaw and wet-dry), chemical (oxidation), and biological (microbial community incubation) ageing on the chemical properties and mineralizability of 350°C and 550°C pine wood PyOM. We used Fourier Transform Infrared spectroscopy (FTIR) and elemental analysis to characterize the aged and unaged PyOM, and cavity ring-down spectroscopy to trace CO2 emissions. The carbon (C) mineralization data from incubation of aged and unaged PyOM with the isolate are provided in co2cmg_picarro_022020.csv. This dataset contains raw carbon dioxide (CO2) data measured on the cavity ring-down spectroscopy over 1 month of incubation. The dataset also includes processed data such as cumulative CO2 emitted over multiple cycles of measurement and CO2 values normalized by the total carbon content in each PyOM treatment. The carbon, hydrogen and nitrogen elemental content of aged and unaged 350°C and 550°C pine wood PyOM are provided in CHN_pyom.csv. The relative peak heights measured during the FTIR analysis of aged and unaged PyOM are provided in ftir_peaks_rel.csv.
Distribution and speciation of rare earth elements in coal combustion by-products via synchrotron microscopy and spectroscopy
Rare earth element (REE) binding environments and associated mineral phases in coal and coal combustion byproducts (CCBs) are not well understood. Advanced characterization of REEs' binding environments before, during, and after production can be vital in establishing an economically viable recovery method for REEs from these materials. Here, this study characterized different REE distributions, cerium (Ce) oxidation states, and Ce binding environments in 11 CCBs collected from various locales via X-ray fluorescence (XRF) elemental mapping and X-ray absorption near edge structure (XANES) at Stanford Synchrotron Radiation Lightsource (SSRL). Bulk Ce LIII edge XANES identified Ce(III) (>85%) as the predominant Ce oxidation state in all studied samples. Ce speciation and XRF elemental map analyses further reveal the REEs in studied samples can be (1) dispersed throughout the aluminosilicate glass phase, (2) as micro-particles in large glass grain, or (3) as independent trace phases in studied samples. Both fly ash and bottom ash contain mainly Ce(III) micro-hotspots (<40 μm), co-localization with a range of elements, including, but not limited to: P, S, Ca, Ti, and Mn. At microscale, Ce can change from Ce(III) to mixture of Ce(III) and Ce(IV) and to 100% Ce(IV) oxide, revealing potential REE-phase decomposition and oxidation in coal and coal combustion process. Our study also observed intraparticle and interparticle distribution difference between light REEs and heavy REEs. Finally, the synchrotron-based characterization confirmed the presence of these trace, previously only theorized, phases during the combustion process and ultimately may inform the simplification of separation and extraction processes for REE from different CCBs.
Mixed Element Microparticle Characterization by Electron Probe Microanalysis
Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.
Cross-section measurements of the {sup 14}N({alpha},p){sup 17}O and {sup 14}N({alpha},{alpha}){sup 14}N reactions between 3.5 and 6 MeV
The cross-section of the {sup 14}N({alpha},p{sub 0}){sup 17}O reaction at angles of 90 deg., 135 deg., and 165 deg. was measured for incident energies between 3.5 and 6.0 MeV simultaneously with the cross-section of the {sup 14}N({alpha},{alpha}){sup 14}N reaction at 165 deg. Interference between these two reactions at the angle of 165 deg. and around 3.9 MeV was taken into account. The technique used is very powerful, thanks to the Ta{sub 450nm}/C target being implanted with a high dose of nitrogen. The {sup 14}N({alpha},p{sub 0}){sup 17}O reaction exhibits some resonances allowing traces of nitrogen to be quantified. This reaction also offers an alternative to the {sup 14}N(d,{alpha}){sup 12}C and {sup 14}N({sup 3}He,p){sup 16}O nuclear reactions for profiling nitrogen in the first few microns below the surface. Moreover, by using {alpha}-particles, Rutherford backscattering spectroscopy can be performed simultaneously with a good mass resolution to depth profile high Z elements in the sample. The sensitivity of these reactions (0.1%) has been tested by measuring the nitrogen traces in a titanium oxide film deposited on silicon. Depth profiling of nitrogen in a TiN layer on a silicon substrate was also performed. In addition, we publish for the first time some cross-sections values for the {sup 14}N({alpha},p{sub 1}){sup 17}O reaction at 90 deg. and 165 deg.; this measurement is a challenging task.
In Situ Measurements of the Reflectances of the LSSTCam Optics and Assessing the Impact of Optical Ghosts
Optical ghosts are image artifacts caused by successive reflections of light between optical surfaces such as lenses, filters, and detectors. These artifacts are unavoidable due to the nonzero reflectances of optical elements and are a major source of contamination for low-surface-brightness science. We use optical ray tracing simulations tuned to observations from LSST Commissioning to quantify the impact of optical ghosts on the LSST data. In particular, we find that ~0.57% of the LSSTCam focal plane is impacted by optical ghosts when averaged across all bands. We also use data from the Collimated Beam Projector to measure the reflectances of various optical elements, generally confirming estimates of ~2% from the systems engineering throughput predictions.
Virus and Bacterial Cell Chemical Analysis by NanoSIMS
In past work for the Department of Homeland Security, the LLNL NanoSIMS team has succeeded in extracting quantitative elemental composition at sub-micron resolution from bacterial spores using nanometer-scale secondary ion mass spectrometry (NanoSIMS). The purpose of this task is to test our NanoSIMS capabilities on viruses and bacterial cells. This initial work has proven successful. We imaged Tobacco Mosaic Virus (TMV) and Bacillus anthracis Sterne cells using scanning electron microscopy (SEM) and then analyzed those samples by NanoSIMS. We were able resolve individual viral particles ({approx}18 nm by 300 nm) in the SEM and extract correlated elemental composition in the NanoSIMS. The phosphorous/carbon ratio observed in TMV is comparable to that seen in bacterial spores (0.033), as was the chlorine/carbon ratio (0.11). TMV elemental composition is consistent from spot to spot, and TMV is readily distinguished from debris by NanoSIMS analysis. Bacterial cells were readily identified in the SEM and relocated in the NanoSIMS for elemental analysis. The Ba Sterne cells were observed to have a measurably lower phosphorous/carbon ratio (0.005), as compared to the spores produced in the same run (0.02). The chlorine/carbon ratio was approximately 2.5X larger in the cells (0.2) versus the spores (0.08), while the fluorine/carbon ratio was approximately 10X lower in the cells (0.008) than the spores (0.08). Silicon/carbon ratios for both cells and spores encompassed a comparable range. The initial data in this study suggest that high resolution analysis is useful because it allows the target agent to be analyzed separate from particulates and other debris. High resolution analysis would also be useful for trace sample analysis. The next step in this work is to determine the potential utility of elemental signatures in these kinds of samples. We recommend bulk analyses of media and agent samples to determine the range of media compositions in use, and to determine how agent composition relates to media composition. After these baseline analyses are performed, the data should be assessed to determine the potential forensic utility of elemental analyses. If promising, validation studies using bulk or NanoSIMS analysis would be necessary.