Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Multi-target camera tracking, hand-off and display LDRD 158819 final report

Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn't lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identifies individual moving targets from the background imagery, and then displays the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.

47 OTHER INSTRUMENTATION↗

Surface Roughness Calculations of Additively Manufactured Cylinders via X-Ray Computed Tomography

X-ray Computed Tomography (X-ray CT) is an analytical technique used in materials science to non–destructively characterize features in variety of materials like polymers, metals, composites, and explosives. It also has the capability of imaging additively manufactured, machined and assembled parts and processes. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations as a result of different stimuli, and assess accuracy of material production. This study will focus on parts manufactured via metal additive manufacturing (AM). Although, AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties. The analysis of 3D printed objects has a strength in analysis in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e. foams) due to stochastic structures. For this study, the print accuracy of several 3D printed cylinders will be assessed via X-ray CT to determine optimal printing parameters for parts with less defects and stronger mechanical properties. This will be accomplished by having the original STL file serve as the baseline surface to compute difference in the CT rendering to calculate surface roughness for each cylinders.

36 MATERIALS SCIENCE↗

Updates on the Predictive Materials Modeling Software Tools

Updates on NASA‘s efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. The PMM effort is part of the Entry Systems Modeling (ESM) project under NASA’s Game Changing Development (GCD) program. To reduce the need for extensive testing and accelerate the design cycle process, ESM is developing simulation and modeling tools that enable the characterization of the properties of thermal protection materials and their response to extremely hot plasma. The Porous Microstructure Analysis (PuMA) software has been developed to compute effective material properties and perform material response simulations on digitized microstructures of porous media. PuMA is able to import three-dimensional digital images obtained from X-ray microtomography or to generate artificial microstructures that mimic real materials. PuMA also provides a module for interactive 3D visualizations. Version 3, which was recently released as open-source, includes modules to compute simple morphological properties such as porosity, volume fractions, pore diameter, and specific surface area. Additional capabilities include the determination of effective thermal and electrical conductivity (both radiative and solid conduction - including the ability to simulate local anisotropy for the latter); effective diffusivity and tortuosity from the continuum to the rarefied regime; techniques to determine the local material orientation, as well as mechanical properties (elasticity coefficients), and permeability. Computed properties are then used to inform a macro-scale material response model, such as those implemented in the Porous material Analysis Toolbox based on OpenFOAM (PATO) software developed within ESM. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale, assuming Local Thermal Equilibrium. Recent efforts include the development of a mechanical erosion model as well as a unified model allowing an intrinsic coupling between fluid and material. Comparison to flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI] and Mars 2020 MEDLI2) is critical in order to validate these computational tools. Examples of ablative material response using the code will be presented, including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrated the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains through the use of massively parallel computations.

material modeling↗

Wind Turbine Blade Finishing Automation: Robotic Toolpath Generation

Wind turbine blades are now over 100 meters long and can reach heights of several meters while in the finishing area of the factory. Because of this, automation should be used to lower the manufacturing cost and make the process safer for blade manufacturing technicians. This session will present a novel method that generates a six degree of freedom robotic toolpath with 3D cameras for the finishing of wind turbine blades to drive down the levelized cost and make wind energy even more competitive in the utility scale energy generation industry.

3d imaging↗

A data-driven framework for permeability prediction of natural porous rocks via microstructural characterization and pore-scale simulation

Understanding the microstructure–property relationships of porous media is of great practical significance, based on which macroscopic physical properties can be directly derived from measurable microstructural informatics. However, establishing reliable microstructure–property mappings in an explicit manner is difficult, due to the intricacy, stochasticity, and heterogeneity of porous microstructures. In this paper, a data-driven computational framework is presented to investigate the inherent microstructure–permeability linkage for natural porous rocks, where multiple techniques are integrated together, including microscopy imaging, stochastic reconstruction, microstructural characterization, pore-scale simulation, feature selection, and data-driven modeling. A large number of 3D digital rocks with a wide porosity range are acquired from microscopy imaging and stochastic reconstruction techniques. A broad variety of morphological descriptors are used to quantitatively characterize pore microstructures from different perspectives, and they compose the raw feature pool for feature selection. Here high-fidelity lattice Boltzmann simulations are conducted to resolve fluid flow passing through porous media, from which reliable permeability references are obtained. The optimal feature set that best represents permeability is identified through a performance-oriented feature selection process, upon which a cost-effective surrogate model is rapidly fitted to approximate the microstructure-permeability mapping via data-driven modeling. This surrogate model exhibits great advantages over empirical/analytical formulas in terms of prediction accuracy and generalization capacity, which can predict reliable permeability values spanning four orders of magnitude. Besides, feature selection also greatly enhances the interpretability of the data-driven prediction model, from which new insights into the mechanism of how microstructural characteristics determine intrinsic permeability are obtained.

58 GEOSCIENCES↗

X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

High-Resolution Phase-Contrast Imaging of Submicron Particles in Unstained Lung Tissue

To access the risks and chances of deposition of submicron particles in the gas-exchange area of the lung, a precise three-dimensional (3D)-localization of the sites of deposition is essential--especially because local peaks of deposition are expected in the acinar tree and in individual alveoli. In this study we developed the workflow for such an investigation. We administered 200-nm gold particles to young adult rats by intratracheal instillation. After fixation and paraffin embedding, their lungs were imaged unstained using synchrotron radiation x-ray tomographic microscopy (SRXTM) at the beamline TOMCAT (Swiss Light Source, Villigen, Switzerland) at sample detector distances of 2.5 mm (absorption contrast) and of 52.5 mm (phase contrast). A segmentation based on a global threshold of grey levels was successfully done on absorption-contrast images for the gold and on the phase-contrast images for the tissue. The smallest spots containing gold possessed a size of 1-2 voxels of 370-nm side length. We conclude that a combination of phase and absorption contrast SRXTM imaging is necessary to obtain the correct segmentation of both tissue and gold particles. This method will be used for the 3D localization of deposited particles in the gas-exchange area of the lung.

60 APPLIED LIFE SCIENCES↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-436: A Method to Evaluate Dosimetric Properties of SFGRT in Eclipse TPS

Purpose: The objective was to develop a method for dose distribution calculation of spatially-fractionated-GRID-radiotherapy (SFGRT) in Eclipse treatment-planning-system (TPS). Methods: Patient treatment-plans with SFGRT for bulky tumors were generated in Varian Eclipse version11. A virtual structure based on the GRID pattern was created and registered to a patient CT image dataset. The virtual GRID structure was positioned on the iso-center level together with matching beam geometries to simulate a commercially available GRID block made of brass. This method overcame the difficulty in treatment-planning and dose-calculation due to the lack o-the option to insert a GRID block add-on in Eclipse TPS. The patient treatment-planning displayed GRID effects on the target, critical structures, and dose distribution. The dose calculations were compared to the measurement results in phantom. Results: The GRID block structure was created to follow the beam divergence to the patient CT images. The inserted virtual GRID block made it possible to calculate the dose distributions and profiles at various depths in Eclipse. The virtual GRID block was added as an option to TPS. The 3D representation of the isodose distribution of the spatially-fractionated beam was generated in axial, coronal, and sagittal planes. Physics of GRID can be different from that for fields shaped by regular blocks because the charge-particle-equilibrium cannot be guaranteed for small field openings. Output factor (OF) measurement was required to calculate the MU to deliver the prescribed dose. The calculated OF based on the virtual GRID agreed well with the measured OF in phantom. Conclusion: The method to create the virtual GRID block has been proposed for the first time in Eclipse TPS. The dosedistributions, in-plane and cross-plane profiles in PTV can be displayed in 3D-space. The calculated OF’s based on the virtual GRID model compare well to the measured OF’s for SFGRT clinical use.

60 APPLIED LIFE SCIENCES↗

3D Sonar for tank waste quantification - 15430

An innovative remote 3D Sonar technology adapted from the oil and gas industry has been successfully applied to the mapping of radioactive sludge deposits during tank, fuel pool and silo remediation operations at the Sellafield site in the UK. The technology can: -Measure the disposition and calculate the volume of settled solids in a waste tank thereby supporting tank closure objectives - Produce accurate 3-D images of solids disposition, structure and tank internals to help identify where sludge deposits and debris are located -Capture real time 'Sonar video' of movement of solids in the tank in real time to aid retrieval - Detect and monitor gas release and bubble generation Aside from direct safety, cost and schedule benefits, improved accuracy and confidence in residual waste volume determinations can lead to increased level of regulator confidence in meeting closure objectives. This technology has potential to bring such benefits to challenges in the DOE estate, such as Savannah River Site (SRS) and Hanford Tank Farms remediation, and operations at the Hanford Waste Treatment Plant. This paper describes the 3D Sonar technology and its applications, and reviews a 3D Sonar demonstration project specifically aimed at enhancing retrieval and closure operations at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical detection threshold of the proton-acoustic range verification technique

Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10{sup 6} protons/pulse and beam current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric Data Exploration with Machine Learning-Aided Visualization in Neutron Science

Recent advancements in neutron and X-ray sources, instrumentation and data collection modes have significantly increased the experimental data size (which could easily contain 108–1010 data points), so that conventional volumetric visualization approaches become inefficient for both still imaging and interactive OpenGL rendition in a 3D setting. We introduce a new approach based on the unsupervised machine learning algorithm, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), to efficiently analyze and visualize large volumetric datasets. Here we present two examples of analyzing and visualizing datasets from the diffuse scattering experiment of a single crystal sample and the tomographic reconstruction of a neutron scanning of a turbine blade. We found that by using the intensity as the weighting factor in the clustering process, DBSCAN becomes very effective in de-noising and feature/boundary detection, and thus enables better visualization of the hierarchical internal structures of the neutron scattering data.

Hui, Yawei↗

Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Transport Properties of Woody Biomass Feedstock Particles Before and After Pyrolysis by Numerical Analysis of X-Ray Tomographic Reconstructions

Lignocellulosic biomass has a complex, species-specific microstructure that governs heat and mass transport during conversion processes. A quantitative understanding of the evolution of pore size and structure is critical to optimize conversion processes for biofuel and bio-based chemical production. Further, improving our understanding of the microstructure of biochar coproduct will accelerate development of its myriad applications. This work quantitatively compares the microstructural features and the anisotropic permeabilities of two woody feedstocks, red oak and Douglas fir, using X-ray computed tomography (XCT) before and after the feedstocks are subjected to pyrolysis. Quantitative analysis of the three-dimensional (3D) reconstructions allows for direct calculations of void fractions, pore size distributions and tortuosity factors. Next, 3D images are imported into an immersed boundary based finite volume solver to simulate gas flow through the porous structure and to directly calculate the principal permeabilities along longitudinal, radial, and tangential directions. The permeabilities of native biomass are seen to differ by three to four orders of magnitude in the different principal directions, but we find that this anisotropy is substantially reduced in the biochar formed during pyrolysis. The quantitative transport properties reported here enhance the ability of pyrolysis simulations to account for feedstock-specific effects and thereby provide a useful touchstone for the biorefining community.

09 BIOMASS FUELS↗

In Situ Strain Evolution on Pt Nanoparticles during Hydrogen Peroxide Decomposition

Fundamental understanding of structural changes during catalytic reactions is crucial to understanding the underlying mechanisms and optimizing efficiencies. Surface energy and related catalytic mechanisms are widely studied. However, the catalyst lattice deformation induced by catalytic processes is not well understood. Here, we study the strain in an individual platinum (Pt) nanoparticle (NP) using Bragg coherent diffraction imaging under in situ oxidation and reduction reactions. When Pt NPs are exposed to H 2 O 2 , a typical oxidizer and an intermediate during the oxygen reduction reaction process, alternating overall strain distribution near the surface and inside the NP is observed at the (111) Bragg reflection. In contrast, relatively insignificant changes appear in the (200) reflection. Density functional theory calculations are employed to rationalize the anisotropic lattice strain in terms of induced stress by H 2 O 2 adsorption and decomposition on the Pt NP surface. Our study provides deeper insight into the activity-structure relationship in this system.

3D imaging↗

Water content modulation enables selective ion transport in 2D MXene membranes

Separation membranes are critical for a range of processes, including but not limited to water desalination, chemical and fuel production, and recycling and recovery applications. Fundamentally, there are intrinsic trade-offs between permeability and selectivity. Local water organization and content can impact membrane structure (short- and long-range) in laminar transition metal carbide (MXene) membranes and impact selective ion permeation. Intercalation of chaotropic cesium (Cs + ) ions within the layers reduces the water content in the membrane and at the surface which cannot be found in the intercalation of other ions. Additionally, 3D imaging using focused ion beam scanning electron microscopy showed fewer defects in the Cs-MXene membrane, due to reduced local water content, leading to more efficient ion sieving. X-ray diffraction and density functional theory calculations on the nanochannel structure demonstrated that the chaotropic ion results in the smallest nanochannel size and induces a stronger resistance to water-induced nanochannel swelling. With a narrower nanochannel, the Cs-MXene membrane limits ion transport pathways, resulting in more selective transport of lithium over other metal cations, as evidenced in both experiment and molecular dynamics simulations. In conclusion, our findings highlight the potential for controlling the structural organization of 2D MXene membranes to enable on-demand transport of ions for diverse applications.

36 MATERIALS SCIENCE↗

Application of synchrotron radiation computed microtomography for quantification of bone microstructure in human and rat bones

This work aims to evaluate histomorphometric quantification by synchrotron radiation computed microto-mography in bones of human and rat specimens. Bones specimens are classified as normal and pathological (for human samples) and irradiated and non-irradiated samples (for rat ones). Human bones are specimens which were affected by some injury, or not. Rat bones are specimens which were irradiated, simulating radiotherapy procedures, or not. Images were obtained on SYRMEP beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. The system generated 14 {mu}m tomographic images. The quantification of bone structures were performed directly by the 3D rendered images using a home-made software. Resolution yielded was excellent what facilitate quantification of bone microstructures.

60 APPLIED LIFE SCIENCES↗