Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Natural Refrigerant Very High Efficiency Residential AC System (Final Technical Report)

United Technologies Research Center (UTRC) in collaboration with the University of Illinois Urbana Champaign (UIUC) proposed in 2009 to design, develop and demonstrate a safe, very low global warming potential (GWP) very high performance air-conditioning (VHPAC) residential system. The proposed residential ducted system was targeted to reduce system direct GWP by a factor of approximately 200, and had the potential to achieve a net 4% reduction in overall annual energy consumption of residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ADEPT Final Report: Dynamic Control of Grid Assets Using Direct AC Converter Cells

Seedling funding was secured through the ARPA-E program to develop a robust, utility-scale Power Converter Augmented Transformer (PCAT). The project designed, fabricated, and tested two 13 kV, 1 MW PCATs operating at an effective switching frequency of up to 50 kHz and at an efficiency of greater than 99%. Two versions of the PCAT were fabricated – one using an imputed DC link (IDCL) topology and the other using a back-to-back (BTB) topology. The IDCL avoids the use of electrolytic capacitors for bulk energy storage, thus improving the lifetime and decreasing the size of the converter, while the BTB topology uses an industry-proven topology that is more commercially viable in the short term. To give the PCAT a lifetime and maintenance profile compatible with typical existing utility assets, a novel Passive Thermal Management System (PTMS) was designed and integrated into both PCATs. The PTMS uses a thermosiphon to remove heat from the power electronic devices without forced cooling and reject it to the ambient environment. In addition, a fail-normal feature was implemented to ensure that in the event of PCAT failure the functionality of the underlying transformer is retained. Attainment of project objectives was verified through testing at the Georgia Tech National Electrical Energy Testing Research and Applications Center (NEETRAC). The IDCL-based PCAT had an efficiency of more than 99.10% and the BTB-based PCAT had an efficiency of more than 99.75%. During testing, the PTMS exceeded project requirements by rejecting the 5 kW output of the converters to a 40 °C environment while keeping devices junction temperatures within their tolerances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nano-Engineered Porous Hollow Fiber Membrane-Based AC System

This report summarizes the work done under a Department of Energy (DOE), Advanced Research Projects Agency (ARPA-E) funded project to develop a liquid desiccant membrane-based independent dehumidification system. The project was jointly funded by United Technologies Corporation (UTC). The membrane development effort was supported and co-funded by Pall Corporation, and 3M Company.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Design and Simulation Practice to Identify Charge Reduction Opportunities for Residential AC/HP Units

Based on three 5-ton, single-speed heat pumps (HPs), using R-410A, which use the same compressor, indoor blower and outdoor fan, the DOE/ORNL Heat Pump Design Model was used to conduct comparative modelling study. Regarding charge reduction opportunities, in general, we recommend: 1. Downsizing the outdoor condenser will reduce the required system charge, i.e. using smaller tube diameters or fewer tubes; reducing the evaporator inner volume is less important; to offset the reduced condenser tube side surface area, one can increase the air side surface area (fin density) or condenser air flow rate via using a more efficient fan. 2. microchannel heat exchangers are most effective in reducing the required charge, by up to 60% in the condenser and evaporator. To develop low charge systems, one should at least use a microchannel heat exchanger as the outdoor condenser. 3. TXV systems are less sensitive to charge reduction. For the drop-in application, one can decrease the charge to minimize the liquid section in the condenser, at the expense of minor performance degradation; for example, when reducing the system charge by 15% (decrease the subcooling degree to 2R), the simulation results prove that the decrease is less than 3% in the EER and less than 6% in the capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

HPC4Mfg with ACS

Distillation in the chemical industry accounts for roughly 10% of energy use in the U.S. While porous mass separating agents (MSAs) appear capable of achieving the same separations for a fraction of the energy, the fundamental lack of a well-understood relationship between the behavior of fluid mixtures confined in MSA pores and the selectivity of MSA-based processes presents a major barrier to their widespread industrial application. This work is the first study to systematically and self-consistently explore a range of parameters describing various molecule-material interactions in MSA-based separations. Through high performance computing (HPC), this study has yielded a fundamental understanding of the influence of confined fluid behavior on selectivity. The results also serve as a knowledge base for subsequent investigations needed to transform the framework for rational design of MSA-based separation processes. This will significantly reduce the energy required for separations central to chemical manufacturing.

36 MATERIALS SCIENCE↗

PSL-AC-CP-1102-004-03: Electrostatic Discharge Simulator Kit Model 930D and Associated Current-Viewing Resistor (V.04)

This document provides instructions for calibrating the Electro-Tech (ETS) electrostatic discharge (ESD) simulator, Model 930D. The calibration shall meet the ± 5% specification for resistance and capacitance as specified in MIL-STD-331C 2009 newer. A series of direct measurements of the Device Under Test (DUT) output at 25 kV using a calibrated LeCroy HDO 6104 oscilloscope (or equivalent 1 MΩ) input impedance storage oscilloscope) are recorded through the 500-pF capacitor, 500-Ω resistor, and a 1-Ω Current Viewing Resistor (CVR). The certified value of the DUT's 25 kV output is calculated using Ohms Law and the certified system resistance and capacitance described in this procedure. Read this document in its entirety before proceeding with the calibration.

42 ENGINEERING↗

OPP-B332-031 Rev AC

This procedure provides guidance for the safe handling and processing of Special Items containing Plutonium (Pu)-238 during special recovery operations in Room 1321 Workstation 2111. This procedure supplements the information provided in Operational Safety Plan (OSP) 332.209 Special Recovery Operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗