Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A study on the creep behavior of alloy 709 using in-situ scanning electron microscopy

In this research, an experimental evaluation of creep properties of Alloy 709 in the temperature range of 750–850 °C was undertaken. Alloy 709 is a novel austenitic stainless steel with 20% Cr and 25% Ni by wt% that was developed for application in structural components of nuclear power plants. Creep rupture tests were conducted in an in-situ heating-loading and Scanning Electron Microscope (SEM) unit equipped with Electron Backscatter Diffraction (EBSD) detector and Energy Dispersive Spectroscopy (EDS). “Real-time” creep damage mechanisms of Alloy 709 at various stresses and temperatures using a flat, un-notched sample with continuously reducing cross-section is studied so that the failure and maximum creep damage occurred at the center of the sample where the in-situ SEM imaging could be focused. Accelerated creep tests at temperatures and stresses above service conditions were performed by employing multiple blocks of constant loads where the loads were increased once the sample attained constant creep rate, indicating a secondary creep regime. This technique ensures multiple data points can be obtained from the same test, saves the time required for an otherwise long-term creep test and usage of SEM. Further, Coincident Site Lattice (CSL) boundary maps were collected as control maps before testing, and the grain boundaries were observed during the creep test to understand the effect of grain boundary character on the creep damage mechanism. Void growth, grain boundary separation, and sliding were found to be the main creep mechanisms whose rate is dependent on stress and temperature. Failure mechanisms studied on the fracture surface using SEM fractography were correlated to the sample surface observations to create complementary information to better understand the underline creep mechanism of Alloy 709.

36 MATERIALS SCIENCE↗

3D Analysis of Fuel Cell Electrocatalyst Degradation on Alternate Carbon Supports

Understanding the mechanisms associated with Pt/C electrocatalyst degradation in proton exchange membrane fuel cell (PEMFC) cathodes is critical for the future development of higher-performing materials; however, there is a lack of information regarding Pt coarsening under PEMFC operating conditions within the cathode catalyst layer. We report a direct and quantitative 3D study of Pt dispersions on carbon supports (high surface area carbon (HSAC), Vulcan XC-72, and graphitized carbon) with varied surface areas, graphitic character, and Pt loadings ranging from 5 to 40 wt %. This is accomplished both before and after catalyst-cycling accelerated stress tests (ASTs) through observations of the cathode catalyst layer of membrane electrode assemblies. Electron tomography results show Pt nanoparticle agglomeration occurs predominantly at junctions and edges of aggregated graphitized carbon particles, leading to poor Pt dispersion in the as-prepared catalysts and increased coalescence during ASTs. Tomographic reconstructions of Pt/HSAC show much better initial Pt dispersions, less agglomeration, and less coarsening during ASTs in the cathode. However, a large loss of the electrochemically active surface area (ECSA) is still observed and is attributed to accelerated Pt dissolution and nanoparticle coalescence. Moreover, a strong correlation between Pt particle/agglomerate size and measured ECSA is established and is proposed as a more useful metric than average crystallite size in predicting degradation behavior across different catalyst systems.

36 MATERIALS SCIENCE↗

Design, Synthesis, and Evaluation of Noble Metal Nanoparticles and In Situ-Decorated Carbon-Supported Nanoparticle Electrocatalysts Using Hypergolic Reactions

Here, we report the first synthesis of metal nanoparticles and supported metal nanoparticles on carbon by using hypergolic reactions. Specifically, we report the synthesis of noble metal nanoparticles (Pt, Ag, and Au) using sodium hydride (NaH) as both an ignition trigger and a reducing agent for the corresponding metal salt precursors. In addition, we report the one-step, in situ synthesis of Pt nanoparticles supported on carbon by adding sucrose as the carbon source. The hypergolically synthesized nanoparticles display elliptical morphology and are more crystalline compared with those conventionally synthesized in solution using sodium borohydride (NaBH 4 ). When tested as electrocatalysts, the hypergolic Pt nanoparticles exhibit more than 2 times higher specific electrochemical active surface area (ECSA) and a higher half-wave potential (E 1/2 ) of 0.94 V vs the reversible hydrogen electrode (RHE) compared to the conventionally synthesized ones. In addition, the electrocatalyst based on the in situ synthesized carbon that was decorated with the Pt nanoparticles synthesized hypergolically outperforms an analogous, state of the art, commercial PtC system. For example, the former shows an attractive E 1/2 (0.94 V) compared with 0.9 V for the commercial PtC. Accelerated durability tests (ADT) in an alkaline environment add another advantage. After 10 000 cycles, the hypergolically synthesized system shows a smaller reduction of E 1/2 and less degradation compared to the commercial PtC (10 mV compared to ∼30 mV). The work described here represents the first reported synthesis using hypergolic reactions of metal nanoparticles as well as supported metal nanoparticles. The properties of the resulting electrocatalysts demonstrate the versatility and promise of the new approach in materials synthesis and open new avenues for further investigation as electrocatalysts.

Chalmpes, Nikolaos↗

Lifetime predictions for dimmable two-channel drivers for color tuning luminaires

Two-channel tunable white lighting (TWL) systems represent the next wave of solid-state lighting (SSL) systems and promise flexibility in light environment while maintaining the high reliability and luminous efficacy expected with SSL devices. TWL systems utilize LED assemblies consisting of two different LED spectra (i.e., often a warm white assembly and a cool white assembly) that are integrated into modules. While these systems provide the ability to adjust the lighting spectrum to match the physiology needs of the task at hand, they also are a potentially more complex lighting system from a performance and reliability perspective. We report an initial study on the reliability performance of such lighting systems including an examination of the lumen maintenance and chromaticity stability of warm white and cool white LED assemblies and the multi-channel driver that provides power to the assemblies. Accelerated stress tests including operational bake tests conducted at 75°C and 95°C were used to age the LED modules, while more aggressive temperature and humidity tests were used for the drivers in this study. Small differences in the performance between the two LED assemblies were found and can be attributed to the different phosphor chemistries. The lumen maintenances of both LED assemblies were excellent. The warm white LED assemblies were found to shift slightly in the green color direction over time while the cool white LED assemblies shifted slightly in the yellow color direction. The net result of these chromaticity shifts is a small, barely perceptible reduction in the tuning range after 6,000 hours of exposure to an accelerating elevated temperature of 75°C.

Chromaticity↗

Round 2 Update of Stress Testing Results for Organic Light-Emitting Diode Panels and Luminaires

Organic light-emitting diode (OLED) sources are a potential solid-state lighting technology for use in indoor lighting applications. Some of the advantages offered by OLEDs include thin profiles, low glare, diffuse lighting, and unique form factors. The U.S. Department of Energy (DOE) has released five reports about OLED technologies to provide information and analysis to the lighting industry. These reports include the evaluation of two different field deployment sites, a market analysis, and two independent assessments of the performance of select commercially available OLED products. This report builds on earlier DOE efforts with OLED technology by updating information about previously benchmarked OLED products (i.e., the Chalina luminaire from Acuity Brands and the Brite 2 and Brite Amber panels from OLEDWorks) in accelerated stress tests (ASTs). In addition, this report also provides an initial analysis of the performance of recently released OLED products—the Brite 3 panels from OLEDWorks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Ion-Accessible Surface Area CNT-Ultracapacitors for Groundwater Desalination

Fresh water is a vital resource for human survival, as well as a key component for a wide range of industrial and agricultural needs. However, only 0.65% of the world’s water resources are available as fresh water, and the demand on the world’s water reserves continues to rise, with the demand already beginning to outpace the supply in many areas. A water-energy nexus is being reached that requires low -cost and -energy solutions for various degrees of treated water. Public awareness of the problem has also risen, such that in a 2012 survey, 88% of Americans reported concerns about potential water shortages. Approximately two-thirds of the world’s population could suffer water shortages over the next few years. Seawater and other saline water supplies make up around 98% of the world’s accessible water. Properly treated to reduce the levels of salinity, this represents an almost unlimited supply of fresh water. The high energy requirements, capital costs, and maintenance requirements to remove salts and other unwanted compounds, however, are barriers to widespread implementation of salt-to-freshwater facilities. These facilities most commonly use reverse osmosis (RO) systems that suffer from high required pressures and failures of moving parts; additionally, these facilities consume much grid energy and require constant maintenance, leading to high capital and operational costs. The RO process also generates large volumes of highly concentrated bio-hazardous brine that is costly to safely return to the ocean. In contrast to RO, capacitive desalination or capacitive deionization (CDI) has fewer moving parts (a low-pressure pump and several valves), operates at low pressure, and does not generate large quantities of brine that are hazardous to marine life. The capacitive charge/discharge of a CDI system can be cycled almost indefinitely, and the system has low energy requirements because the capacitive discharge electrical current can be co-generated back to the system. RO must remove the water from the salt while CDI removes the salt from the water. This represents a significant difference in the number of molecules which must be moved and energy required to desalinate water. However, CDI has not seen widespread use for large- or small-scale desalination because electrode efficiency has limited the extraction rate below what is useful for most applications. Mainstream demonstrated the following successes during this SBIR program: Performance - We developed an innovative new electrode structure for the high-efficiency removal of ions from salt-contaminated water samples by CDI. Based on prototype electrochemical tests, our CDI consumes as low as 0.71 kW/m 3 of treated water (compared to 2.9 to 3.7 kW/m 3 for RO). Scalability – During Phase II, we increased the electrode size from 3.8 cm 2 single-sided electrodes to 180 cm 2 double-sided electrodes. Using larger acid baths and CVD furnace, we increased electrode fabrication capacity increased by 315 times. Scalable electrochemical CDI stack design and balance of plant – During Phase II, we demonstrated at scalable low-pressure drop stack design and balance of plant for the continuous removal of ions. Corrosion Resistance – Based on accelerated corrosion testing data, our high-quality graphitic electrodes have a significantly improved corrosion resistance. This was 20 times better corrosion resistance than our Phase I electrodes and significantly higher than typical CDI system electrodes. Flexibility –By tuning the pore size of the electrode materials, we demonstrated the removal of key target ionic contaminants, such as sodium chloride, nitrate, and phosphate salts. These ionic contaminants are common in agricultural and industrial wastewater runoff and are difficult to remove by conventional methods, which require excessive use of reagents.

Cox, Dr. Philip↗

Effect of Extended Aging and Oxidation on Linear Poly(propylenimine)-Mesoporous Silica Composites for CO 2 Capture from Simulated Air and Flue Gas Streams

Physical aging or degradation of amine-containing polymers and supported amine adsorbents is a critical issue that could limit practical application of such materials for CO 2 capture. However, to date, there is a scarcity of studies that evaluate the long-term stability of amine-based sorbents without the exclusive use of accelerated aging tests. Here, we demonstrate that extended aging (~2 years) of linear poly(propylenimine) (LPPI) confined in mesoporous silica (SBA-15) supports does not drastically impact the CO 2 adsorption performance under simulated flue gas (10% CO 2 ) and direct air capture (DAC, 400 ppm CO 2 ) conditions, although the behavior of the aged sorbents and polymers in the two CO 2 concentration regimes differs. Sorbents made with aged LPPI had modestly decreased CO 2 uptake performance (<~20% lower) compared to the fresh polymers, with overall good CO 2 cycling performance. The data indicate that only slow degradation occurs under the deployed ambient storage conditions. Even after extended aging, the LPPI-based sorbents preserved their ability to display stable temperature-swing cycling performance. In parallel, the impact of blending LPPI polymers of different number-average molecular weights, M n , is evaluated, seeking to understand its impact on adsorbent performance. We find that the results demonstrate that blends of two M n aged LPPI give similar CO 2 adsorption performance to adsorbents made from a single M n LPPI, suggesting that molecular weight will not negatively impact adsorbent performance in the studied M n range. After an accelerated oxidation experiment, the aged LPPI sorbents retained a larger portion of the samples’ original performance when cycling under simulated flue gas conditions than under DAC conditions. However, in each case, the oxidized sorbents could be cycled repeatedly with consistent uptake performance. Overall, these first of their kind extended aging tests suggest that LPPI-based amine adsorbents offer promise for long term, stable use in carbon capture applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Battery Life Prediction Using Reduced-Order Physics Models and Machine Learning (CRADA Final Report)

Phase 1 (Original CRADA, plus no-cost extension modifications #1-3, 6/1/2017 to 3/13/2021): The Australian Department of Defence (AUDoD) is performing accelerated aging tests of Li-ion batteries to benchmark their reliability and degradation characteristics. Using its previously developed battery lifetime predictive model framework, the National Laboratory of the Rockies (NLR) will develop analytical models based the AUDoD data to predict lifetime of the multiple Li-ion battery chemistries under real-world use scenarios of interest to AUDoD. The NLR model is based on physical degradation mechanisms encountered by Li-ion batteries and has been previously validated. Phase 2 (CRADA modification #4, plus no-cost extension modification #5, 2/22/2021 to 3/30/2025): Train and support Australian Department of Defence personnel to use NLR software for model-based estimation of Li-ion battery lifetime using accelerated battery aging data collected by the Australian Department of Defence. Under separate DOE funding from 2019 to 2021, NLR enhanced its battery life-prediction software using machine learning algorithms to automate portions of the model-fitting process, requiring significantly less labor and expert judgment and also adding uncertainty quantification, increasing statistical rigor. Under Phase 2, NLR will customize NLR Software and provide it to AuDoD. NLR will enhance its NLR Model to capture aging modes of AuDoD's multi-cell modules, including cell-balancing effects. NLR will develop example single-cell and multi-cell models based on one AuDoD battery aging dataset. NLR will train AuDoD personnel on NLR Software. By the conclusion of the project, NLR will have provided AuDoD the training materials, a user manual and software needed to perform their own analysis of additional and/or future battery aging datasets.

33 ADVANCED PROPULSION SYSTEMS↗

Application of Electronics Packaging Fundamentals to Photovoltaic Interconnects and Packaging

The energy capacity of photovoltaic (PV) installations worldwide has increased significantly in the last decade, increasing the demand for rigorous investigation of the physical phenomena causing degradation and failures in PV modules. As PV reliability science develops, established methods and approaches from longer-standing industries can inform and expedite PV reliability advances. This work demonstrates how thermomechanical solder bond fatigue models derived for electronics packaging applications can be applied to both standard and emerging PV interconnect designs. This expertise cannot be directly translated to PV however, as target PV module lifetimes are significantly longer than most electronics and the modules must withstand the natural climate wherever they are deployed. Verification of analytical reliability models is then an additional challenge, due to model size, test time, and climate variability. Furthermore, unconventional materials, such as low-temperature solders, are now being integrated into PV designs, for which appropriate material models must be selected and material parameters derived. In this paper, the current state of PV interconnect research is explored, with an emphasis on the experimental and simulation approaches and models being used for this work. Recent results for standard module architectures as well as emerging interconnect schemes are discussed.

14 SOLAR ENERGY↗

"Soiling, Cleaning, and Abrasion: The Results of the Five-Year Photovoltaic Glass Coating Field Study" [Slides]

External contamination ("soiling") of the incident surface is a major limiting factor for solar technologies. A 5-year field glass coupon study was conducted to better understand external contamination and its effects; compare cleaning methods and the use of preventative coatings; and explore the abrasion resulting from cleaning to advise on accelerated abrasion testing. Test sites included the cities of Dubai (UAE), Kuwait City (Kuwait), Mesa (AZ), Mumbai (India), and Sacramento (CA). Through the 5-year cumulative study, dry brush, water spray, and wet sponge and squeegee cleaning methods were compared to no cleaning. Optical microscopy was used to obtain images, including representative color images, grayscale images for object analysis, and oblique images for coating integrity assessment. A thresholding protocol was developed to analyze and distinguish specimens using the ImageJ software. Optical performance was quantified using a spectrophotometer, including comprehensive optical characterization (transmittance, reflectance, and absorptance in addition to forward- and back-scattering). Atomic force microscopy was used to verify the abrasion damage morphology, including the width and depth of surface scratches. Analysis of the results included correlation of optical performance and particle area coverage, rank order (by coating or location), and the acceleration factor for abrasion damage. The efficacy of external cleaning was more readily distinguished from the effectiveness of antisoiling coatings. The acceleration factor for dry brush cleaning of a porous silica coating was found to be on the order of unity.

14 SOLAR ENERGY↗

Betatron radiation and emittance growth in plasma wakefield accelerators

Beam-driven plasma wakefield acceleration (PWFA) has demonstrated great progress during the past two decades of research. The novel Facility for Advanced Accelerator Experimental Tests (FACET) II, currently under construction, will provide 10 GeV electron beams with unprecedented parameters for the next generation of PWFA experiments. In the context of the FACET II facility, we introduce simulation results on expected betatron radiation and its potential application to diagnose emittance preservation and hosing instability in the upcoming PWFA experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodes

Purpose: The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). Methods: Seventy-five kilovoltage cone beam CTs (KV-CBCT) from six patients were included for this retrospective study. For each patient, three different IMRT plans were created based on a planning CT using three different MLC leaf widths of 2.5, 5, and 10 mm, respectively. For each CBCT, the prostate displacement was determined by a dual image registration. Adaptive plans were created by shifting selected MLC leaf pairs to compensate for daily prostate movements. To evaluate the impact of MLC leaf width on the adaptive plan for each daily CBCT, three MLC shifted plans were created using three different leaf widths of MLCs (a total of 225 adaptive treatment plans). Selective dosimetric endpoints for the tumor volumes and organs at risk (OARs) were evaluated for these adaptive plans. Using the planning CT from a selected patient, MLC shifted plans for three hypothetical longitudinal shifts of 2, 4, and 8 mm were delivered on the three linear accelerators to test the deliverability of the shifted plans and to compare the dose accuracy of the shifted plans with the original IMRT plans. Results: Adaptive plans from 2.5 and 5 mm MLCs had inadequate dose coverage to the prostate (D99 < 97%, or D{sub mean} < 99% of the planned dose) in 6%-8% of the fractions, while adaptive plans from 10 mm MLC led to inadequate dose coverage to the prostate in 25.3% of the fractions. The average V{sub 56Gy} of the prostate over the six patients was improved by 6.4% (1.6%-32.7%) and 5.8% (1.5%-35.7%) with adaptive plans from 2.5 and 5 mm MLCs, respectively, when compared with adaptive plans from 10 mm MLC. Pelvic lymph nodes were well covered for all MLC adaptive plans, as small differences were observed for D99, D{sub mean}, and V{sub 50.4Gy}. Similar OAR sparing could be achieved for the bladder and rectum with all three MLCs for treatment adaptation. The MLC shifted plans can be accurately delivered on all three linear accelerators with accuracy similar to their original IMRT plans, where gamma (3%/3 mm) passing rates were 99.6%, 93.0%, and 92.1% for 2.5, 5, and 10 mm MLCs, respectively. The percentages of pixels with dose differences between the measurement and calculation being less than 3% of the maximum dose were 85.9%, 82.5%, and 70.5% for the original IMRT plans from the three MLCs, respectively. Conclusions: Dosimetric advantages associated with smaller MLC leaves were observed in terms of the coverage to the prostate, when the treatment was adapted to account for daily prostate movement for concurrent irradiation of the prostate and pelvic lymph nodes. The benefit of switching the MLC from 10 to 5 mm was significant (p Much-Less-Than 0.01); however, switching the MLC from 5 to 2.5 mm would not gain significant (p= 0.15) improvement. IMRT plans with smaller MLC leaf widths achieved more accurate dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of breathing cracks using vibrations

The influence of half-ellipse-shaped fatigue cracks and machined through-thickness cuts on the impact response of cantilever beam samples were analysed using the Finite Element Method and compared to experimental data for different crack depths. The effect of sample width was analysed for geometries with fatigue cracks (aspect ratio a/c = 0.45) and through-thickness cuts (rectangular cracks). The differences between both types of damage were analysed numerically and experimentally. The effect of sample width was studied and it was found that the behaviour of the cantilever with a fatigue-crack approaches that of the saw cut sample when the fatigue crack reaches the edges of the test piece. Acceleration data were analysed using the Fast Fourier Transform algorithm and Power Density Spectra (PSD) were obtained. For fatigue-cracked samples, harmonics of the frequencies of natural modes of oscillation were found. Analytical modelling was done using a mass-spring-damper system for studying the bilinear behaviour of the stiffness element. Harmonics found were assigned to the breathing behaviour of the crack. The detection threshold using frequency shifts inspection was twice as high as using spectral analysis. This would allow crack detection at half of the fatigue life of the specimen.

42 ENGINEERING↗

Regenerative Carbonate-Based Thermochemical Energy Storage System for Concentrating Solar Power

Southern Research has developed a thermochemical energy storage (TCES) technology that utilizes the endothermic-exothermic reversible carbonation of calcium oxide (lime) to store thermal energy at high-temperatures, such as those achieved by next generation concentrating solar power (CSP) facilities. The major challenges addressed in the development of this system include refining a high capacity, yet durable sorbent material and designing a low thermal resistance low-cost heat exchanger reactor system to move heat between the sorbent and a heat transfer fluid under conditions relevant for CSP operation (e.g., energy density, reaction kinetics, heat flow). The proprietary stabilized sorbent was developed by Precision Combustion, Inc. (PCI). A factorial matrix of sorbent compositions covering the design space was tested using accelerated high throughput screening in a thermo-gravimetric analyzer. Several promising formulations were selected for more thorough evaluation and one formulation with high capacity (0.38 g CO 2 /g sorbent) and durability (>99.7% capacity retention over 100 cycles) was chosen as a basis for further development of the energy storage reactor system. In parallel with this effort, a full range of currently available commercial and developmental heat exchange reactor systems and sorbent loading methods were examined through literature research and contacts with commercial vendors. Process models were developed to examine if a heat exchange reactor system and balance of plant can meet required TCES performance and cost targets, optimizing tradeoffs between thermal performance, exergetic efficiency, and cost. Reactor types evaluated included many forms, from microchannel reactor, to diffusion bonded heat exchanger, to shell and tube heat exchangers. The most viable design for application to a supercritical CO 2 power cycle operating at 200-300 bar pressure and >700°C was determined to be a combination of a diffusion bonded heat exchanger with a shell and tube reactor. A bench scale reactor system was then designed and constructed to test sorbent performance under more commercially relevant conditions. This system utilizes a tube-in tube reactor design containing approximately 250 grams sorbent and is able to operate under a wide range of temperature, pressure and flow conditions as needed to explore system performance under a variety of operating conditions. A variety of sorbent loading methods may be tested using the reactor design. Initial bench test results over 25 cycles showed very high sorbent stability (>99%) and sufficient capacity (>0.28 g CO 2 /g sorbent) for an economical commercial-scale system. Initial technoeconomic evaluation of the proposed storage system show that the sorbent cost should not have a significant impact on overall system cost, and that the largest cost impacts come from the heat exchanger reactor and balance of plant equipment, including compressors and gas storage, due to the high temperatures for sCO 2 cycles. Current estimated system costs are $47/kWhth based on current material and equipment cost estimates.

14 SOLAR ENERGY↗

TURBULENCE AND RADIO MINI-HALOS IN THE SLOSHING CORES OF GALAXY CLUSTERS

A number of relaxed, cool-core galaxy clusters exhibit diffuse, steep-spectrum radio sources in their central regions, known as radio mini-halos. It has been proposed that the relativistic electrons responsible for the emission have been reaccelerated by turbulence generated by the sloshing of the cool core gas. We present a high-resolution MHD simulation of gas sloshing in a galaxy cluster coupled with subgrid simulations of relativistic electron acceleration to test this hypothesis. Our simulation shows that the sloshing motions generate turbulence on the order of {delta}v {approx} 50-200 km s{sup -1} on spatial scales of {approx}50-100 kpc and below in the cool core region within the envelope of the sloshing cold fronts, whereas outside the cold fronts, there is negligible turbulence. This turbulence is potentially strong enough to reaccelerate relativistic electron seeds (with initial {gamma} {approx} 100-500) to {gamma} {approx} 10{sup 4} via damping of magnetosonic waves and non-resonant compression. The seed electrons could remain in the cluster from, e.g., past active galactic nucleus activity. In combination with the magnetic field amplification in the core, these electrons then produce diffuse radio synchrotron emission that is coincident with the region bounded by the sloshing cold fronts, as indeed observed in X-rays and the radio. The result holds for different initial spatial distributions of pre-existing relativistic electrons. The power and the steep spectral index ({alpha} Almost-Equal-To 1-2) of the resulting radio emission are consistent with observations of mini-halos, though the theoretical uncertainties of the acceleration mechanisms are high. We also produce simulated maps of inverse-Compton hard X-ray emission from the same population of relativistic electrons.

79 ASTRONOMY AND ASTROPHYSICS↗