Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

2022 LDRD Annual Report

This summary report provides an overview of all LDRD projects at Argonne that concluded in Fiscal Year 2022. Many projects are funded for multiple years, the initial fiscal year for each project is indicated by the first four digits of the LDRD project number.

25 ENERGY STORAGE↗

Acceptance Criteria Part B: LMQXFA cold mass and cryo-assembly

This document specifies the acceptance criteria for the LMQXFA cold mass and cryoassembly. If all the requirements specified in this document are met, then the U.S. HL-LHC AUP LMQXFA and LQXFA deliverables will be accepted by Please note that the definition of threshold as it is being used by the American contribution is not the same as objective, according to the HL-LHC quality policy.

43 PARTICLE ACCELERATORS↗

Final Co-op Presentation Fall 2023

This presentation is an overview of the four projects I worked on during my first co-op term. The first project was a 3D-printed support for a horn that was being X-rayed. My second project was a website that compiled all data available on outgassing and created a comprehensive database. My third project was creating a cart for a PIP-II absorber that needs to be transported down the beamline using NX. My fourth and final project was testing a prototype of a collimator.

43 PARTICLE ACCELERATORS↗

Final Cooling with Thick Wedges for a Muon Collider

A muon collider is a particle accelerator that collides muons rather than protons or electrons. An important component of such a collider is cooling, in which the emittance of the muon beam is reduced to make it suitable for use in a collider. In the last stage of this process, called final 4D cooling, emittance in the transverse axes is reduced while emittance in the longitudinal axis is allowed to grow. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on single thick wedges. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We characterized the effects of various parameters on the performance of this system, including the initial emittances and Twiss parameters, the length and angle of the wedges, the length of the drift channel, and the length, frequency, gradient, and phase of the RF cavities. We optimized the design parameters of the cooling channel and produced two conceptual designs (corresponding to two possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ≈ 3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Fabrication and test of COMB dipole magnet with STAR® wires

Fermilab is working on superconducting accelerator magnet R&D under the framework of the U.S. MagnetDevelopment Program (USMDP). An integral part of that program is High Temperature Superconducting (HTS)accelerator magnet development to- demonstrate HTS self‐fields of 5 T or greater- be compatible with operation in hybrid LTS/HTS configuration• to probe fields beyond 16 T for future High Energy Physics (HEP) experiments

43 PARTICLE ACCELERATORS↗

Test Stand Functional Requirements for Testing MQXFA Magnets and Q1/Q3 Cryostat Assemblies (Rev.3)

This document specifies test stand requirements for testing the High Luminosity LHC (HL-LHC, or HiLumi LHC) MQXFA magnets and LQXFA/B cryostat assemblies. Total of 12 (3 pre-series, 7 series production and 2 re-work) of these cryostat assemblies are expected to be fabricated and delivered to CERN by the U.S. HL-LHC Accelerator Upgrade Project (US HL-LHC AUP) as part of the U.S. contributions to the LHC High Luminosity Upgrade. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 (LQXFA) and Q3 (LQXFB) inner triplet optical elements in front of the interactions points 1 (ATLAS) and 5 (CMS). One LMQXFA cold mass is installed in each cryostat assembly and each cold mass consists of two MQXFA quadrupole magnets. MQXFA, LMQXFA and LQXFA/B functional requirements are specified in [1,2,3].MQXFA magnets will be tested at BNL Vertical Magnet Test Facility (VMTF) and 12 cryostat assembly tests planned at Fermilab’s Horizontal Magnet Test Facility (HMTF). This document specifies the test stand functional requirements for testing MQXFA magnets and LQXFA/B cryostat assemblies.

43 PARTICLE ACCELERATORS↗

Booster Neutrino Beam operations and neutrino flux prediction

The Booster Neutrino Beam (BNB) Line is used to produce neutrino beams for the 8 GeV Neutrino Program at Fermilab. This talk will provide a summary of the BNB operations and an estimate of the neutrino flux that is produced by the beamline. The talk will also summarize the work to upgrade the system which records the longitudinal structure of the primary proton beam that is delivered to BNB production target.

43 PARTICLE ACCELERATORS↗

IROS 2023 Workshop Report: Draft Guidelines on Manufacturing Procedures, Test Methods and Reporting for Soft Robotics

Soft roboticists are facing challenges with reproducibility, which prevents researchers from making holistic comparisons to prior work, impedes full understanding of results, and forces the need to “reinvent the wheel,” delaying fundamental advances. Reproducibility of results is key to advancing science as well as achieving technology transfer from research laboratories to industrial applications. Recently, a discussion-based workshop dedicated to the topic, “Developing Standard Testing and Reporting Guidelines for Soft Robotics,” was held at IROS 2023 in Detroit, MI. The purpose of this document is to record a set of recommendations and voluntary draft guidelines for soft roboticists concerning fabrication/manufacturing, test procedures, and reporting, which were collectively developed at the workshop. Together as a community, we hope to improve the reporting standards of soft robotics and drive the field as a whole toward more rigorous research practices.

43 PARTICLE ACCELERATORS↗

T-1065: Secondary Emitters Study

One possibility to make a fast and radiation resistant shower maximum (SM) detector or preshower detector is to use a secondary emitter (SE) as an active element. This method was proposed in 1990. Micro channel plates (MCP) were used as SE in the SM. The attractive properties of such SM are: 1) a two-dimensional map of energy at the SE location; 2) timing information at few tens of picosecond level, also as transverse shower size and 3) possible separation of electromagnetic and hadronic energy based on the differences of the shower size and timing. An electron-multiplier-based sampling calorimeter requires thin planar detectors at an affordable cost. Large-area photo detectors based on ALD-functionalized 20-cm-square borosilicate glass capillary micro-channel plates (MCPs), currently being developed by the LAPPD Collaboration, are candidates for the active elements. The first results of the new shower maximum detector with the micro channel plate photomultiplier (MCP-PMT) as active elements are described. The current proposal is the next natural step in this direction. The experimenters propose using large-area MCPs assembled without the usual bialkali photocathodes as the active element in sampling calorimeters. LAPPD modules without photocathodes can be economically assembled in a glove box and then pumped and sealed using the process to construct photomultipliers, bypassing the slow and expensive vacuum-transfer process required by bialkali photocathodes. The first use of electron multipliers, in this case MCPs (Fig. 1, left) as an active element in multi-layer sampling calorimeters is described. A chevron of two MCPs in vacuum, was located behind a tungsten plate on which 5 GeV and 26 GeV electrons were incident (Fig. 1, right). The amplitude of the MCP signal (Fig. 2) as a function of the tungsten thickness was measured. The primary electrons produce a shower of secondary particles, including positron-electron pairs and gammas; the response of the MCPs (Fig. 2, left) is proportional to the number of particles in the shower, which is dependent on the initial particle energy. The MCP signal shape is presented in the Fig. 2, right). The FWHM of the signal is 1 ns.

43 PARTICLE ACCELERATORS↗

Improved Chopper System for a Direct Geometry Spectrometer at the Second Target Station

This report describes a chopper cascade suitable for a cold direct geometry spectrometer at a pulsed neutron source with a low repetition rate such as the Second Target Station (STS) currently being planned at Oak Ridge National Laboratory (ORNL). The chopper cascade offers the following capabilities: selection of a variable number of pulses per frame (flexible pulse suppression), selection of pulses with increasing timing separation within one frame, and an increasing pulse width ∆t within one frame, in order to achieve an even energy resolution over several pulses at different wavelengths across the frame.

43 PARTICLE ACCELERATORS↗

Simulation Study of Monoenergetic Photon Source LiDAR System Performance for Emergency Response Applications

The following report summarizes the results of a Monte Carlo simulation and modeling study of the Lawrence Berkeley National Laboratory’s (LBL) Monoenergetic Photon Source (MPS) as part of a high-energy LiDAR system for use in emergency response applications. A set of image quality indicators (IQI) and nonsensitive phantoms or generalized surrogates for search targets have been identified for use in the planned measurement campaign at the Berkeley Lab Laser Accelerator (BELLA) Center toward the end FY2023. These items were modeled and the time-of-flight (TOF) spectral responses following irradiation were calculated for a set of varying operating conditions. The goal of this study was to both predict the LiDAR system performance as well as determine if minor modifications to the IQI and phantom designs were required before fabrication. It was found that the IQI and target designs both overlap and extend towards the limit of performance of the system and are thus suitable for the final project measurement campaign.

43 - PARTICLE ACCELERATORS↗

Guidelines for beamline and front-end radiation shielding design at the Advanced Photon Source.

Shielding for the APS will be such that the individual radiation worker dose will be as low as reasonably achievable (ALARA). The ALARA goals for the APS are to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 500 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS radiation worker, the goal is to keep the maximum occupational total effective dose equivalent of any one employee as far below 200 mrem/yr as reasonably achievable. The ALARA goal for APS beamline scientists is to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 100 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS beamline scientist, the goal is to keep the maximum occupational total effective dose equivalent of any one scientist as far below 50 mrem/yr as reasonably achievable. The dose is actively monitored by the radiation monitors on the storage ring wall in each sector and by the frequent area surveys performed by the health physics personnel. For cases in which surveys indicate elevated hourly dose rates that may impact worker exposure, additional local shielding is provided to reduce the radiation field to an acceptable level. Passive area monitors are used throughout the facility to integrate doses in various areas. The results are analyzed for trends of increased doses, and shielding in these areas is evaluated and improved, as appropriate. The APS policy for on-site nonradiation workers in the vicinity of the APS facilities requires that the average nonradiation worker dose be below 0.2 mSv/yr (20 mrem/yr). In addition, the dose at the site boundary from all pathways is required to be below 0.1 mSv/yr (10 mrem/yr). For future modifications of the facility, the doses shall be evaluated and additional shielding provided to meet the policy requirements.

43 PARTICLE ACCELERATORS↗

Integrated Program of Experimental Diagnostics at the NNSS. An Integrated, Prioritized Work Plan for Diagnostic Development and Maintenance and Supporting Capability

This Integrated Program of Experimental Diagnostics at the NNSS is an integrated prioritized work plan for the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), program that is independent of individual National Security Enterprise Laboratories’ (Labs) requests or specific Subprograms being supported. This prioritized work plan is influenced by national priorities presented in the Predictive Capability Framework (PCF) and other strategy documents (Primary and Secondary Assessment Technologies Plans and the Plutonium Experiments Plan). This document satisfies completion criteria for FY 2010 MRT milestone #3496: Document an integrated, prioritized work plan for diagnostic development, maintenance, and supporting capability. This document is an update of the 3-year NNSS plan written a year ago, September 21, 2009, to define and understand Lab requests for diagnostic implementation. This plan is consistent with Lab interpretations of the PCF, Primary Assessment Technologies, and Plutonium Experiment plans.

43 PARTICLE ACCELERATORS↗