Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytic linearization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Computational evaluation of the flexoelectric effect in dielectric solids

Flexoelectricity is a size-dependent electromechanical mechanism coupling polarization and strain gradient. It exists in a wide variety of materials, and is most noticeable for nanoscale objects, where strain gradients are higher. Simulations are important to understand flexoelectricity because experiments at very small scales are difficult, and analytical solutions are scarce. Here, we computationally evaluate the role of flexoelectricity in the electromechanical response of linear dielectric solids in two-dimensions. We deal with the higher-order coupled partial differential equations using smooth meshfree basis functions in a Galerkin method, which allows us to consider general geometries and boundary conditions. We focus on the most common setups to quantify the flexoelectric response, namely, bending of cantilever beams and compression of truncated pyramids, which are generally interpreted through approximate solutions. While these approximations capture the size-dependent flexoelectric electromechanical coupling, we show that they only provide order-of-magnitude estimates as compared with a solution fully accounting for the multidimensional nature of the problem. We discuss the flexoelectric mechanism behind the enhanced size-dependent elasticity in beam configurations. We show that this mechanism is also responsible for the actuation of beams under purely electrical loading, supporting the idea that a mechanical flexoelectric sensor also behaves as an actuator. The predicted actuation-induced curvature is in a good agreement with experimental results. The truncated pyramid configuration highlights the critical role of geometry and boundary conditions on the effective electromechanical response. Our results suggest that computer simulations can help understanding and quantifying the physical properties of flexoelectric devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Linear and Rotary Electric Machine Topologies for a Hybrid Hydraulic Electric Architecture of Off-Highway Vehicles

Electrification of off-highway vehicles offers the benefits of improved energy efficiency, enhanced controllability, and reduction in greenhouse gas emissions. However, progress towards electrification has been limited by the low power density of electric components compared to hydraulic components. A recently proposed hybrid hydraulic electric vehicle architecture provides a potential solution to these power density challenges by minimizing the required power rating of the electric components. This paper investigates the optimal design of linear and rotary electric machines for this new system architecture. Key performance metrics are identified for the electric machine, several variants of electric machines are analytically sized and compared for two different power levels, and an FEA-assisted design optimization is performed on promising candidates. Based on the optimization results, it is shown that an axial flux rotary machine is most suitable for implements requiring high power ratings, while the linear machine's form factor makes it a compelling candidate for lower power implements.

42 ENGINEERING↗

Nonequilibrium solvent effects in Born-Oppenheimer molecular dynamics for ground and excited electronic states

The effects of solvent on molecular processes such as excited state relaxation and photochemical reaction often occurs in a nonequilibrium regime. Dynamic processes such as these can be simulated using excited state molecular dynamics. In this work, we describe methods of simulating nonequilibrium solvent effects in excited state molecular dynamics using linear-response time-dependent density functional theory and apparent surface charge methods. These developments include a propagation method for solvent degrees of freedom and analytical energy gradients for the calculation of forces. Molecular dynamics of acetaldehyde in water or acetonitrile are demonstrated where the solute-solvent system is out of equilibrium due to photoexcitation and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data points tested. The model was capable of predicting the depth of the maximum dose within 1 mm. Anthropomorphic phantom benchmark testing of modulated and patterned MLCs treatment plans showed agreement to measurement within 3% in target regions using thermoluminescent dosimeters (TLD). Using radiochromic film normalized to TLD, a gamma criteria of 3% of maximum dose and 2 mm DTA was applied with a pass rate of least 85% in the high dose, high gradient, and low dose regions. Finally, recalculations of patient plans using DPM showed good agreement relative to a commercial TPS when comparing dose volume histograms and 2D dose distributions. Conclusions: A unique analytical source model coupled to the dose planning method Monte Carlo dose calculation code has been modified and validated using basic beam data and anthropomorphic phantom measurement. While this tool can be applied in general use for a particular linac model, specifically it was developed to provide a singular methodology to independently assess treatment plan dose distributions from those clinical institutions participating in National Cancer Institute trials.

60 APPLIED LIFE SCIENCES↗

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cascaded analysis of signal and noise propagation through a heterogeneous breast model

Purpose: The detectability of lesions in radiographic images can be impaired by patterns caused by the surrounding anatomic structures. The presence of such patterns is often referred to as anatomic noise. Others have previously extended signal and noise propagation theory to include variable background structure as an additional noise term and used in simulations for analysis by human and ideal observers. Here, the analytic forms of the signal and noise transfer are derived to obtain an exact expression for any input random distribution and the ''power law'' filter used to generate the texture of the tissue distribution. Methods: A cascaded analysis of propagation through a heterogeneous model is derived for x-ray projection through simulated heterogeneous backgrounds. This is achieved by considering transmission through the breast as a correlated amplification point process. The analytic forms of the cascaded analysis were compared to monoenergetic Monte Carlo simulations of x-ray propagation through power law structured backgrounds. Results: As expected, it was found that although the quantum noise power component scales linearly with the x-ray signal, the anatomic noise will scale with the square of the x-ray signal. There was a good agreement between results obtained using analytic expressions for the noise power and those from Monte Carlo simulations for different background textures, random input functions, and x-ray fluence. Conclusions: Analytic equations for the signal and noise properties of heterogeneous backgrounds were derived. These may be used in direct analysis or as a tool to validate simulations in evaluating detectability.

60 APPLIED LIFE SCIENCES↗

Computing Nonequilibrium Responses with Score-Shifted Stochastic Differential Equations

Using equilibrium fluctuations to understand the response of a physical system to an externally imposed perturbation is the basis for linear response theory, which is widely used to interpret experiments and shed light on microscopic dynamics. For nonequilibrium systems, perturbations cannot be interpreted simply by monitoring fluctuations in a conjugate observable and general response results rely on path ensemble averaging. Furthermore, these techniques do not apply to perturbations that affect the diffusion tensor in a stochastic system. Here, we introduce an “effective” physical process that represents the diffusion perturbed dynamics and enables accurate calculations of responses to a change in the diffusion. Interestingly, the effective dynamics contain an additional drift involving the instantaneous “score” of the system, and we leverage score matching algorithms to carry out nonequilibrium response calculations on systems for which the exact stationary distribution is unknown.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perturbation theory analysis of attosecond photoionization

Ionization of an atom by a few-cycle attosecond xuv pulse is analyzed using perturbation theory (PT), keeping terms in the transition amplitude up to second order in the pulse electric field. Within the PT approach, we present an ab initio parametrization of the ionized electron angular distribution (AD) using rotational invariance and symmetry arguments. This parametrization gives analytically the dependence of the AD on the carrier envelope phase (CEP), the polarization of the pulse, and on the ionized electron momentum direction, p. For the general case of an elliptically polarized pulse, we show that interference of the first- and second-order transition amplitudes causes a CEP-dependent asymmetry (with respect to p->-p) and both elliptic and circular dichroism effects. All of these effects are maximal in the polarization plane and depend not only on the CEP but also on the phase of dynamical atomic parameters that enter our parametrization of the AD. Within the single active electron model of an atom, for an initial s or p state we define all dynamical parameters in terms of radial matrix elements (analytic expressions for which are given for the Coulomb and zero-range potentials). For ionization of the H atom by linearly polarized pulses, our PT results are in excellent agreement with results of numerical solutions of the time-dependent Schroedinger equation of Peng et al.[New J. Phys. 10, 025030 (2008)]. Also, our numerical results show that the asymmetries and dichroism effects at low electron energies have a different physical origin from those at high electron energies. Moreover, our results for Gaussian and cosine-squared pulse shapes are in good qualitative agreement. Finally, we show that our analytic formulas may prove useful for determining few-cycle extreme ultraviolet (xuv) pulse characteristics, such as the CEP and the polarization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Verification of particle simulation of radio frequency waves in fusion plasmas

Radio frequency (RF) waves can offer heating, current and flow drive, as well as instability control for steady state operations of fusion experiments. A particle simulation model has been designed in this work to provide a first-principles tool for studying the RF nonlinear interactions with plasmas. In this model, ions are considered as fully kinetic particles using the Vlasov equation and electrons are treated as guiding centers using the drift kinetic equation. This model has been implemented in a global gyrokinetic toroidal code using real electron-to-ion mass ratio. To confirm the model, linear simulations of ion plasma oscillation, ion Bernstein wave, and lower hybrid wave are carried out in cylindrical geometry and found to agree well with analytic predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A realistic renormalizable supersymmetric E₆ model

A complete realistic model based on the supersymmetric version of E₆ is presented. It consists of three copies of matter 27, and a Higgs sector made of 2×(27+27⁻)+351´+351´⁻ representations. An analytic solution to the equations of motion is found which spontaneously breaks the gauge group into the Standard Model. The light fermion mass matrices are written down explicitly as non-linear functions of three Yukawa matrices. This contribution is based on Ref. [1].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoacoustic effect generated by moving optical sources: Motion in one dimension

Although the photoacoustic effect is typically generated by pulsed or amplitude modulated optical beams, it is clear from examination of the wave equation for pressure that motion of an optical source in space will result in the production of sound as well. Here, the properties of the photoacoustic effect generated by moving sources in one dimension are investigated. The cases of a moving Gaussian beam, an oscillating delta function source, and an accelerating Gaussian optical sources are reported. The salient feature of one-dimensional sources in the linear acoustic limit is that the amplitude of the beam increases in time without bound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Curvature and Frontier Orbital Energies in Density Functional Theory

Perdew et al. [Phys. Rev. Lett 49, 1691 (1982)] discovered and proved two different properties that exact Kohn-Sham density functional theory (DFT) must obey: (i) The exact total energy versus particle number must be a series of linear segments between integer electron points; (ii) Across an integer number of electrons, the exchange-correlation potential may ``jump’’ by a constant, known as the derivative discontinuity (DD). Here, we show analytically that in both the original and the generalized Kohn-Sham formulation of DFT, the two are in fact two sides of the same coin. Absence of a derivative discontinuity necessitates deviation from piecewise linearity, and the latter can be used to correct for the former, thereby restoring the physical meaning of the orbital energies. Using selected small molecules, we show that this results in a simple correction scheme for any underlying functional, including semi-local and hybrid functionals as well as Hartree-Fock theory, suggesting a practical correction for the infamous gap problem of density functional theory. Moreover, we show that optimally-tuned range-separated hybrid functionals can inherently minimize both DD and curvature, thus requiring no correction, and show that this can be used as a sound theoretical basis for novel tuning strategies.

density functional theory↗

Sedimentation and shear-induced dynamics of spheroids in fluids with spatial viscosity variations

A generalized reciprocal theorem is used to relate the force and torque induced on a particle in an inertia-less fluid with small variation in viscosity to integrals involving Stokes flow fields and the spatial dependence of viscosity. These resistivity expressions are analytically evaluated using spheroidal harmonics and then used to obtain the mobility of the spheroid during sedimentation, and in linear flows, of a fluid with linear viscosity stratification. The coupling between the rotational and translational motion induced by stratification rotates the spheroid’s centerline, creating a variety of rotational and translational dynamics dependent upon the particle’s aspect ratio, κ, and the component of the stratification unit vector in the gravity direction, d g . Spheroids with 0.55 ⪅ κ ⪅ 2.0 exhibit the largest variety of settling behaviors. Interestingly, this range covers most microplastics and typical microorganisms. One of the modes include a stable orientation dependent only on κ and d g , but independent of initial orientation, thus allowing for the potential control of settling angles and sedimentation rates. In a simple shear flow, cross-streamline migration occurs due to the stratification-induced force generated on the particle. Similarly, a particle no longer stays at the stagnation point of a uniaxial extensional flow. While fully analytical results are obtained for spheroids, numerical simulations provide a source of validation. These simulations also provide additional insights into the stratification-induced force- and torque-producing mechanisms through the stratification-induced stress, which is not accessed in the reciprocal theorem-based analytical calculations.

Geophysical and Geological Flows: Stratified flows↗

Unitarity of spin-2 theories with linearized Weyl symmetry in D=2+1 dimensions

Here we prove unitarity of the recently found fourth-order (in derivatives) self-dual model of spin-2 by investigating the analytic structure of its propagator. The model describes massive particles of helicity +2 (or -2) in D=2+1 dimensions and corresponds to the quadratic truncation of a higher derivative topologically massive gravity about a flat background. It is an intriguing example of a theory where a term in the propagator of the form 1/[{open_square}{sup 2}({open_square}-m{sup 2})] does not lead to ghosts. The crucial role of the linearized Weyl symmetry in getting rid of the ghosts is pointed out. We use a peculiar pair of gauge conditions which fix the linearized reparametrizations and linearized Weyl symmetries separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Simple Analytical Model for Rocky Planet Interiors

This work aims to explore the scaling relations among rocky exoplanets. The assumption that the internal gravity increases linearly in the core and stays constant in the mantle is tested against numerical simulations, and a simple model is constructed, applicable to rocky exoplanets of CMF (core mass fraction) = 0.2–0.35 and mass = 0.1–30 M ⊕. Various scaling relations are derived: (1) CMF ≈ CRF 2 (core radius fraction squared), (2) ${P}_{\mathrm{typical}}\sim {g}_{s}^{2}$ (typical interior pressure scales as surface gravity squared), (3) energy released in core formation is $\sim \tfrac{1}{10}$ the total gravitational energy, (4) effective heat capacity of the mantle $\approx \left(\tfrac{{M}_{p}}{{M}_{\oplus }}\right)\times 7.5\times {10}^{27}$ J K -1 , (5) moment of inertia $\approx \tfrac{1}{3}{M}_{p}{R}_{p}^{2}$. These approximate relations are handy for quick use owing to their simplicity and lucidity, and provide insights into the interior structures of those exoplanets.

planets and satellites: interiors↗

MODELING THE LARGE-SCALE BIAS OF NEUTRAL HYDROGEN

We present new analytical estimates of the large-scale bias of neutral hydrogen (H I). We use a simple, non-parametric model which monotonically relates the total mass of a halo M{sub tot} with its H I mass M{sub HI} at zero redshift; for earlier times we assume limiting models for the {Omega}{sub HI} evolution consistent with the data presently available, as well as two main scenarios for the evolution of our M{sub HI}-M{sub tot} relation. We find that both the linear and the first nonlinear bias terms exhibit a strong evolution with redshift, regardless of the specific limiting model assumed for the H I density over time. These analytical predictions are then shown to be consistent with measurements performed on the Millennium Simulation. Additionally, we show that this strong bias evolution does not sensibly affect the measurement of the H I power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗