Search NASA⌕ Search

SEARCH · Search NASA

Results for “Basis functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

General-Surrogate Adaptive Sampling Using Interquartile Range for Design Space Exploration

Abstract A surrogate model is a common tool to approximate system response at untested points for design space exploration. Adaptive sampling has been studied for improving the accuracy of surrogates iteratively by introducing additional samples (simulations and experiments). New samples are often selected based on the estimated uncertainty in the design space. While some surrogates such as kriging have readily available uncertainty models for their predictions, other surrogates do not. Consequently, there have been studies of using the process of leaving-samples-out (LSO) used in cross-validation tools to estimate prediction uncertainty, such as the universal prediction distribution (UPD). In this paper, an adaptive sampling scheme for general surrogates is proposed based on LSO, similar to cross-validation and interquartile range (IQR). Multiple submodels are first developed from LSO. The uncertainty is then estimated from the IQR of these surrogates at a given point. New samples are added iteratively at the point with maximum IQR for design space exploration. The proposed scheme is illustrated using kriging, radial basis function, and neural network surrogates. The proposed scheme is evaluated using four algebraic test functions. Multiple sets of initial samples were produced to account for randomness. For these test functions, the proposed scheme was found to be more accurate and robust than kriging with its own uncertainty model. The proposed scheme was more accurate than the UPD for three out of the four test functions. For a fixed number of samples, the IQR-based adaptive sampling also proved to be more accurate than all-at-once sampling in most cases even when the estimated uncertainty was only mildly correlated with prediction errors.

Engineering↗

A Novel Active Optimization Approach for Rapid and Efficient Design Space Exploration Using Ensemble Machine Learning

In this work, a novel design optimization technique based on active learning, which involves dynamic exploration and exploitation of the design space of interest using an ensemble of machine learning algorithms, is presented. In this approach, a hybrid methodology incorporating an explorative weak learner (regularized basis function model) that fits high-level information about the response surface and an exploitative strong learner (based on committee machine) that fits finer details around promising regions identified by the weak learner is employed. For each design iteration, an aristocratic approach is used to select a set of nominees, where points that meet a threshold merit value as predicted by the weak learner are selected for evaluation. In addition to these points, the global optimum as predicted by the strong learner is also evaluated to enable rapid convergence to the actual global optimum once the most promising region has been identified by the optimizer. Additionally, this methodology is first tested by applying it to the optimization of a two-dimensional multi-modal surface and, subsequently, to a complex internal combustion (IC) engine combustion optimization case with nine control parameters related to fuel injection, initial thermodynamic conditions, and in-cylinder flow. It is found that the new approach significantly lowers the number of function evaluations that are needed to reach the optimum design configuration (by up to 80%) when compared to conventional optimization techniques, such as particle swarm and genetic algorithm-based optimization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel active optimization approach for rapid and efficient design space exploration using ensemble machine learning

In this work, a novel design optimization technique based on active learning, which involves dynamic exploration and exploitation of the design space of interest using an ensemble of machine learning algorithms, is presented. In this approach, a hybrid methodology incorporating an explorative weak learner (regularized basis function model) which fits high-level information about the response surface, and an exploitative strong learner (based on committee machine) that fits finer details around promising regions identified by the weak learner, is employed. For each design iteration, an aristocratic approach is used to select a set of nominees, where points that meet a threshold merit value as predicted by the weak learner are selected to be evaluated using expensive function evaluation. In addition to these points, the global optimum as predicted by the strong learner is also evaluated to enable rapid convergence to the actual global optimum once the most promising region has been identified by the optimizer. This methodology is first tested by applying it to the optimization of a two-dimensional multi-modal surface. The performance of the new active learning approach is compared with traditional global optimization methods, namely micro-genetic algorithm (pGA) and particle swarm optimization (PSO). It is demonstrated that the new optimizer is able to reach the global optimum much faster with a significantly fewer number of function evaluations. Subsequently, the new optimizer is also applied to a complex internal combustion (IC) engine combustion optimization case with nine control parameters related to fuel injection, initial thermodynamic conditions, and in-cylinder flow. It is again found that the new approach significantly lowers the number of function evaluations that are needed to reach the optimum design configuration (by up to 80%) when compared to particle swarm and genetic algorithm-based optimization techniques.

Machine learning, active learning, design optimiza↗

Hybrid Improved Empirical Mode Decomposition and Artificial Neural Network Model for the Prediction of Critical Heat Flux (CHF)

Three Hybrid artificial neural network (ANN) models namely radial basis function (RBF), generalized regression neural networks (GRNN), and multi-layer perceptron (MLP) combined with empirical mode decomposition (EMD) are developed for CHF predictive modelling using CHF experimental databases.First, the original experimental inputs data series are decomposed into several intrinsic mode functions (IMFs) and one residual by EMD, whose components are divided into high, medium and low components. The performance parameters of the hybrid models indicates that the root mean square error (RMSE) are 0.8831, 0.6522, and 0.4149; the mean absolute error (MAE) are 0.6697, 0.4636, and 0.1935. The values of the R-square of the developed prediction approach utilizing EMD-RBF, EMD-GRNN, and EMD-MLP models are 0.8553, 0.9302, and 0.9818, and the index of agreement are 0.9464, 0.9700, and 0.9894., The value of the R-square and the index of agreement of the proposed models are much higher than those of the simple models .The Pearson's test results show that the association strength between the measured and the predicted values of the proposed model EMD-MLP is the strongest. These results show the following: (a) compared with other related, recent studies, the prediction accuracy of the hybrid model EMD- MLP proposed in this research is the best hybrid model; (b) the proposed hybrid model (EMD-MLP) attains superior performance compared with simple models.

Djeddou, Messaoud↗

Homogenized blocked arcs for multicriteria optimization of radiotherapy: Analytical and numerical solutions

Purpose: Homogenized blocked arcs are intuitively appealing as basis functions for multicriteria optimization of rotational radiotherapy. Such arcs avoid an organ-at-risk (OAR), spread dose out well over the rest-of-body (ROB), and deliver homogeneous doses to a planning target volume (PTV) using intensity modulated fluence profiles, obtainable either from closed-form solutions or iterative numerical calculations. Here, the analytic and iterative arcs are compared. Methods: Dose-distributions have been calculated for nondivergent beams, both including and excluding scatter, beam penumbra, and attenuation effects, which are left out of the derivation of the analytic arcs. The most straightforward analytic arc is created by truncating the well-known Brahme, Roos, and Lax (BRL) solution, cutting its uniform dose region down from an annulus to a smaller nonconcave region lying beyond the OAR. However, the truncation leaves behind high dose hot-spots immediately on either side of the OAR, generated by very high BRL fluence levels just beyond the OAR. These hot-spots can be eliminated using alternative analytical solutions ''C'' and ''L,'' which, respectively, deliver constant and linearly rising fluences in the gap region between the OAR and PTV (before truncation). Results: Measured in terms of PTV dose homogeneity, ROB dose-spread, and OAR avoidance, C solutions generate better arc dose-distributions than L when scatter, penumbra, and attenuation are left out of the dose modeling. Including these factors, L becomes the best analytical solution. However, the iterative approach generates better dose-distributions than any of the analytical solutions because it can account and compensate for penumbra and scatter effects. Using the analytical solutions as starting points for the iterative methodology, dose-distributions almost as good as those obtained using the conventional iterative approach can be calculated very rapidly. Conclusions: The iterative methodology is appropriate and useful for computing homogenized blocked arcs, as it produces better dose-distributions than the analytic approaches and their obvious extensions, and can more straightforwardly be used to generate homogenized arcs for concave OARs. However, the analytical solutions provide promising starting points for the iterative algorithm, leading to fast convergence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomy structure creation and editing using 3D implicit surfaces

Purpose: To accurately reconstruct, and interactively reshape 3D anatomy structures' surfaces using small numbers of 2D contours drawn in the most visually informative views of 3D imagery. The innovation of this program is that the number of 2D contours can be very much smaller than the number of transverse sections, even for anatomy structures spanning many sections. This program can edit 3D structures from prior segmentations, including those from autosegmentation programs. The reconstruction and surface editing works with any image modality. Methods: Structures are represented by variational implicit surfaces defined by weighted sums of radial basis functions (RBFs). Such surfaces are smooth, continuous, and closed and can be reconstructed with RBFs optimally located to efficiently capture shape in any combination of transverse (T), sagittal (S), and coronal (C) views. The accuracy of implicit surface reconstructions was measured by comparisons with the corresponding expert-contoured surfaces in 103 prostate cancer radiotherapy plans. Editing a pre-existing surface is done by overdrawing its profiles in image views spanning the affected part of the structure, deleting an appropriate set of prior RBFs, and merging the remainder with the new edit contour RBFs. Two methods were devised to identify RBFs to be deleted based only on the geometry of the initial surface and the locations of the new RBFs. Results: Expert-contoured surfaces were compared with implicit surfaces reconstructed from them over varying numbers and combinations of T/S/C planes. Studies revealed that surface-surface agreement increases monotonically with increasing RBF-sample density, and that the rate of increase declines over the same range. These trends were observed for all surface agreement metrics and for all the organs studied--prostate, bladder, and rectum. In addition, S and C contours may convey more shape information than T views for CT studies in which the axial slice thickness is greater than the pixel size. Surface editing accuracy likewise improves with larger sampling densities, and the rate of improvement similarly declines over the same conditions. Conclusions: Implicit surfaces based on RBFs are accurate representations of anatomic structures and can be interactively generated or modified to correct segmentation errors. The number of input contours is typically smaller than the number of T contours spanned by the structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-CAMPUS-J-02: Automatic Recognition of Patient Treatment Site in Portal Images Using Machine Learning

Purpose: To investigate the method to automatically recognize the treatment site in the X-Ray portal images. It could be useful to detect potential treatment errors, and to provide guidance to sequential tasks, e.g. automatically verify the patient daily setup. Methods: The portal images were exported from MOSAIQ as DICOM files, and were 1) processed with a threshold based intensity transformation algorithm to enhance contrast, and 2) where then down-sampled (from 1024×768 to 128×96) by using bi-cubic interpolation algorithm. An appearance-based vector space model (VSM) was used to rearrange the images into vectors. A principal component analysis (PCA) method was used to reduce the vector dimensions. A multi-class support vector machine (SVM), with radial basis function kernel, was used to build the treatment site recognition models. These models were then used to recognize the treatment sites in the portal image. Portal images of 120 patients were included in the study. The images were selected to cover six treatment sites: brain, head and neck, breast, lung, abdomen and pelvis. Each site had images of the twenty patients. Cross-validation experiments were performed to evaluate the performance. Results: MATLAB image processing Toolbox and scikit-learn (a machine learning library in python) were used to implement the proposed method. The average accuracies using the AP and RT images separately were 95% and 94% respectively. The average accuracy using AP and RT images together was 98%. Computation time was ∼0.16 seconds per patient with AP or RT image, ∼0.33 seconds per patient with both of AP and RT images. Conclusion: The proposed method of treatment site recognition is efficient and accurate. It is not sensitive to the differences of image intensity, size and positions of patients in the portal images. It could be useful for the patient safety assurance. The work was partially supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Improving lung cancer prognosis assessment by incorporating synthetic minority oversampling technique and score fusion method

Purpose: This study aims to investigate the potential to improve lung cancer recurrence risk prediction performance for stage I NSCLS patients by integrating oversampling, feature selection, and score fusion techniques and develop an optimal prediction model. Methods: A dataset involving 94 early stage lung cancer patients was retrospectively assembled, which includes CT images, nine clinical and biological (CB) markers, and outcome of 3-yr disease-free survival (DFS) after surgery. Among the 94 patients, 74 remained DFS and 20 had cancer recurrence. Applying a computer-aided detection scheme, tumors were segmented from the CT images and 35 quantitative image (QI) features were initially computed. Two normalized Gaussian radial basis function network (RBFN) based classifiers were built based on QI features and CB markers separately. To improve prediction performance, the authors applied a synthetic minority oversampling technique (SMOTE) and a BestFirst based feature selection method to optimize the classifiers and also tested fusion methods to combine QI and CB based prediction results. Results: Using a leave-one-case-out cross-validation (K-fold cross-validation) method, the computed areas under a receiver operating characteristic curve (AUCs) were 0.716 ± 0.071 and 0.642 ± 0.061, when using the QI and CB based classifiers, respectively. By fusion of the scores generated by the two classifiers, AUC significantly increased to 0.859 ± 0.052 (p < 0.05) with an overall prediction accuracy of 89.4%. Conclusions: This study demonstrated the feasibility of improving prediction performance by integrating SMOTE, feature selection, and score fusion techniques. Combining QI features and CB markers and performing SMOTE prior to feature selection in classifier training enabled RBFN based classifier to yield improved prediction accuracy.

60 APPLIED LIFE SCIENCES↗

SU-F-R-17: Advancing Glioblastoma Multiforme (GBM) Recurrence Detection with MRI Image Texture Feature Extraction and Machine Learning

Purpose: To test the potential of early Glioblastoma Multiforme (GBM) recurrence detection utilizing image texture pattern analysis in serial MR images post primary treatment intervention. Methods: MR image-sets of six time points prior to the confirmed recurrence diagnosis of a GBM patient were included in this study, with each time point containing T1 pre-contrast, T1 post-contrast, T2-Flair, and T2-TSE images. Eight Gray-level co-occurrence matrix (GLCM) texture features including Contrast, Correlation, Dissimilarity, Energy, Entropy, Homogeneity, Sum-Average, and Variance were calculated from all images, resulting in a total of 32 features at each time point. A confirmed recurrent volume was contoured, along with an adjacent non-recurrent region-of-interest (ROI) and both volumes were propagated to all prior time points via deformable image registration. A support vector machine (SVM) with radial-basis-function kernels was trained on the latest time point prior to the confirmed recurrence to construct a model for recurrence classification. The SVM model was then applied to all prior time points and the volumes classified as recurrence were obtained. Results: An increase in classified volume was observed over time as expected. The size of classified recurrence maintained at a stable level of approximately 0.1 cm{sup 3} up to 272 days prior to confirmation. Noticeable volume increase to 0.44 cm{sup 3} was demonstrated at 96 days prior, followed by significant increase to 1.57 cm{sup 3} at 42 days prior. Visualization of the classified volume shows the merging of recurrence-susceptible region as the volume change became noticeable. Conclusion: Image texture pattern analysis in serial MR images appears to be sensitive to detecting the recurrent GBM a long time before the recurrence is confirmed by a radiologist. The early detection may improve the efficacy of targeted intervention including radiosurgery. More patient cases will be included to create a generalizable classification model applicable to a larger patient cohort. NIH R43CA183390 and R01CA188300.NSF Graduate Research Fellowship DGE-1144087.

60 APPLIED LIFE SCIENCES↗

SU-F-I-41: Calibration-Free Material Decomposition for Dual-Energy CT

Purpose: To eliminate tedious phantom calibration or manually region of interest (ROI) selection as required in dual-energy CT material decomposition, we establish a new projection-domain material decomposition framework with incorporation of energy spectrum. Methods: Similar to the case of dual-energy CT, the integral of the basis material image in our model is expressed as a linear combination of basis functions, which are the polynomials of high- and low-energy raw projection data. To yield the unknown coefficients of the linear combination, the proposed algorithm minimizes the quadratic error between the high- and low-energy raw projection data and the projection calculated using material images. We evaluate the algorithm with an iodine concentration numerical phantom at different dose and iodine concentration levels. The x-ray energy spectra of the high and low energy are estimated using an indirect transmission method. The derived monochromatic images are compared with the high- and low-energy CT images to demonstrate beam hardening artifacts reduction. Quantitative results were measured and compared to the true values. Results: The differences between the true density value used for simulation and that were obtained from the monochromatic images, are 1.8%, 1.3%, 2.3%, and 2.9% for the dose levels from standard dose to 1/8 dose, and are 0.4%, 0.7%, 1.5%, and 1.8% for the four iodine concentration levels from 6 mg/mL to 24 mg/mL. For all of the cases, beam hardening artifacts, especially streaks shown between dense inserts, are almost completely removed in the monochromatic images. Conclusion: The proposed algorithm provides an effective way to yield material images and artifacts-free monochromatic images at different dose levels without the need for phantom calibration or ROI selection. Furthermore, the approach also yields accurate results when the concentration of the iodine concentrate insert is very low, suggesting the algorithm is robust with respect to the low-contrast scenario.

60 APPLIED LIFE SCIENCES↗

Effect of the shape on the spin state and exchange in quantum dots. Feynman path integral analysis

The ab initio computer simulation of the mixed quantum states of 1–5-nm model ellipsoid quantum dots with “soft” walls containing two and three quantum-indistinguishable nonrelativistic electrons has been performed by the path integral method. The calculation has been carried out beyond the single-electron and mean-field approximations with the fundamentally exact inclusion of Coulomb and exchange correlations of all orders and the spin variable. Distributions over the eigenfunctions of the spin-squared operator, as well as the equilibrium spin numbers, have been obtained depending on the shape of a quantum dot and the temperature. The complete set of basis functions symmetrized in permutations according to the spin of the system has been obtained by application of the Young symmetry operators. The dependence of the energy on the shape of the quantum dot corresponds to the negative sign of the surface tension at its boundary. The calculation indicates that the spin magnetic susceptibility in the system of two electrons decreases strongly for spherical quantum dots (“pairing” of spins) and the temperature dependences have a pronounced maximum whose position depends on the shape of the quantum dot. For three electrons in an oblate quantum dot, the inversion of the energy levels of spin states is observed and affects the spin magnetic susceptibility. The results indicate a strong dependence of the energy of collective spin states of electrons on the detailed inclusion of exchange and Coulomb spatial correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic and ferroelectric ordering in BiMn{sub 2}O{sub 5} oxide

A group-theoretical analysis of the magnetic phase of BiMn{sub 2}O{sub 5} oxide is performed using the space symmetry group of the compound. Using the projection operator method, we determine the basis functions of the irreducible representation of the space group, which are expressed in terms of the magnetic vector components. This representation can govern two phase transitions from the paramagnetic state to the antiferromagnetic phase with close temperatures and ordering of the spins of manganese ions in two crystallographic positions. It is found from renorm group analysis of these transitions that when these transitions occur as second- order transitions, the electric polarization does not appear in the system because spin fluctuations in this case elevate the symmetry of the system. Polarization appears when at least one of these transitions becomes a first-order transition as a result of spin fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A small-parameter approach for few-body problems

A procedure to solve few-body problems is developed which is based on an expansion over a small parameter. The parameter is the ratio of potential energy to kinetic energy for states having not small hyperspherical quantum numbers, K>K{sub 0}. Dynamic equations are reduced perturbatively to equations in the finite-dimension subspace with K {<=} K{sub 0}. Contributions from states with K>K{sub 0} are taken into account in a closed form, i.e., without an expansion over basis functions. Estimates concerning the efficiency of the approach are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional imaginary lobachevsky space. Separation of variables and contractions

The Inoenue-Wigner contraction from the SO(2, 1) group to the E(1, 1) group is used to relate the separation of variables in Laplace-Beltrami (Helmholtz) equations for the corresponding two-dimensional homogeneous spaces: two-dimensional one sheeted hyperboloid and two-dimensional pseudo-Euclidean space. Here we consider the contraction limits of some basis functions for the subgroup coordinates only.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixing of hole states in GaAs/AlAs(110) heterostructures

States in the AlAs/GaAs(12)/AlAs(110) quantum well and AlAs(6)/GaAs(12)(110) superlattice are considered. For analysis of mixing of light- and heavy-hole states in these structures, a parameter-dependent set of basis functions is suggested and the values of the parameter at which one of the functions describes basically heavy-hole states and the other light-hole states are determined. For the energy region considered in the study, four energy levels are determined in the AlAs/GaAs(12)/AlAs(110) quantum well and, correspondingly, four minibands in the AlAs(6)/GaAs(12)(110) superlattice. Analysis shows that the first and fourth levels in the quantum well and the first and fourth minibands in the superlattice are related basically to heavy-hole states. The other two states in the quantum well and the second and third minibands in the super-lattice are structurally more complex: in these states and minibands, the hole states are noticeably mixed. In these minibands, states are substantially separated in space and in spin.

36 MATERIALS SCIENCE↗

On Possible States of the Crystal Structure Preceding to a Phase Transition in Zn{sub 1 –} {sub x}V{sub x}Se (0.01 ≤ x ≤ 0.10) Crystals

The systematic new formations observed in the reciprocal lattice of the cubic structural modification of a II–VI compound are characterized using a detailed neutron diffraction study of bulk semiconducting ZnSe crystals with an increased vanadium content. Direct evidence that the additional sites k = (1/3 1/3 1/3) 2π/a (k is the wave vector and a is cubic unit cell parameter) observed by neutron scattering in the crystals, in the case when they belong to mutually penetrated rotated sublattices, contain a superstructure contribution formed by short-wave deformation, is obtained for the first time. This structure state is determined as a pretransition to the concentration fcc–hcp phase transformation, and the basis functions that allow one to analyze atomic displacements, the correlation between which create distortion-type superstructures, are indicated for the transition through one-arm channel, considering the transitions by the star of wave vector k{sub 5} of the fcc lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗