Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments, Part II: On-line studies with short-lived accelerator-produced radionuclides

We report a novel combination of advanced gas-chromatography and detection systems coupled to a buffer-gas cell was characterized on-line to allow gas-phase chemical studies of accelerator-produced short-lived α -decaying mercury, francium, and astatine isotopes. These were produced in 40 Ar- and 48 Ca-induced nuclear fusion–evaporation reactions, subsequently isolated in the recoil separators MARS at Texas A&M University, USA, and TASCA at GSI Darmstadt, Germany, before being thermalized in a buffer-gas-stopping cell. From the latter, the nuclear reaction products were extracted into gas-phase chromatographic systems, suitable for registering α-decaying short-lived radionuclides, such as isotopes of superheavy elements. Efficiencies of 21(3)% for 204-209 Fr were reached for the extraction into the optimized miniCOMPACT gas-chromatography setup, indicating that this technique enables the identification of isotopes of volatile as well as non-volatile elements. These studies guide the path towards chemical investigations of superheavy elements beyond flerovium, which are out of reach with currently used setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mo-99/Tc-99m Separation: An Assessment of Technical Options

Several strategies for the effective separation of 99mTc from 99Mo have been developed and validated. Due to the success of column chromatographic separation using acidic alumina coupled with high specific activity fission 99Mo (F 99Mo) for production of 99Mo/99mTc generators, however, most technologies until recently have generated little interest. The reduced availability of F 99Mo and consequently the shortage of 99Mo/99mTc column generators in the recent past have resurrected interest in the production of 99Mo as well as 99mTc by alternate routes. Most of these alternative production processes require separation techniques capable of providing clinical grade 99mTc from low specific activity 99Mo or irradiated Mo targets. For this reason there has been renewed interest in alternate separation routes. This paper reviews the reported separation technologies which include column chromatography, solvent extraction, sublimation and gel systems that have been traditionally used for the fabrication of 99Mo/99mTc generator systems. The comparative advantage, disadvantage, and technical challenges toward adapting the emerging requirements are discussed. New developments such as solid-phase column extraction, electrochemical separation, extraction chromatography, supported liquid membrane (SLM) and thermochromatographic techniques are also being evaluated for their potential application in the changed scenario of providing 99mTc from alternate routes. Based on the analysis provided in this review, it appears that some proven separation technologies can be quickly resurrected for the separation of clinical grade 99mTc from macroscopic levels of reactor or cyclotron irradiated molybdenum targets. Furthermore, emerging technologies can be developed further to respond to the expected changing modes of 99mTc production.

nuclear medicine↗

Thermal stability of poly(ethylene-co-vinyl acetate) based materials

The thermal stability properties of poly (ethylene-co-vinyl acetate) composites have been studied in support of our core programmes in materials qualification and life assessment. The material is used as a binder phase for boron particles in highly filled (70 wt %) composites. Our studies show that the uncured resin readily accumulates acetic acid through hydrolysis of the pendent acetate groups which alters the acidity (pH) of the material. Thermal desorption studies in combination with gas-chromatography-mass spectrometry show that the resin readily evolves acetic acid when thermally aged to temperatures up to 75°C. Gel Permeation Chromatography (GPC) suggests that thermal ageing induces a gradual reduction in resin molecular weight and confirms the susceptibility of the material to chain scission. Heating at elevated temperatures in excess of 300oC is required to induce significant changes in the carbon skeleton through deacetylation and dehydration processes and the production of unsaturated main chain double bonds. Overall, the mechanical response of these filled composites are found to be relatively complex with the extent of polymer-filler interactions possibly playing an important role in determining key engineering properties. Mechanical property studies confirm a small but significant decrease in modulus presumably linked to thermally induced chain scission of the EVA binder.

36 MATERIALS SCIENCE↗

Developing a new ethylene glycol/H 2 O pretreatment system to achieve efficient enzymatic hydrolysis of sugarcane bagasse cellulose and recover highly active lignin: Countercurrent extraction

Improving pretreatment efficiency is a critical premise in achieving efficient biomass conversion, and obtaining high-performance natural polymers is the guarantee of high-value conversion of biomass. Here, in this study, a new pilot-scale continuous countercurrent pretreatment reaction unit about ethylene glycol-alkali solution was designed for pretreating sugarcane bagasse in order to achieve efficient separation of the three major components of lignocellulose when expanding the scale of pretreatment, reduce lignin deposition on the fiber surface, and obtain highly active lignin and excellent enzymatic hydrolysis efficiency of cellulose. X-ray diffractometer (XRD), X-ray photoelectron spectrometer (XPS), brunauer-emmett-teller (BET) and scanning electron microscope (SEM) methods are used to analyze the structural properties of sugarcane bagasse before and after pretreatment, and high-performance liquid chromatography (HPLC) is used to analyze the monosaccharide components in the enzymatic solution. In addition, the structural properties of the recovered lignin are analyzed by gel permeation chromatography (GPC), 31 P NMR and 2D-HSQC-NMR methods. The results indicate that the system can gain a high cellulose recovery of 92.99% along with a lignin removal of 95.33%, and recovered lignin has low lignin carbohydrate complexes, low condensation, and rich in phenolic hydroxyl groups for 1.95 mmol/g. Meanwhile, the countercurrent pretreatment system can effectively reduce the deposition of lignin on the cellulose surface, which is evidently superior to the non-countercurrent pretreatment and facilitates the efficiency of enzymatic saccharification of substrate, achieving a high glucose yield of 99% as well as a total sugar yield of 91.11%. The method efficiently separates biomass in a green manner, and solid residues are easily hydrolyzed, showing potential for industrial-scale production.

09 BIOMASS FUELS↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Confocal Raman Microscopy Study of Ion-Interaction Retention at Reversed-Phase Chromatographic Interfaces

Ion-interaction chromatography utilizes the addition of amphiphilic (surfactant) molecules to the mobile phase solution in order to bring about the retention and separation of hydrophilic ionic analytes on reversed-phase liquid chromatographic stationary phases. The mechanism by which retention and separation in ion-interaction chromatography is accomplished remains unclear, although two primary mechanisms of this phenomenon have been proposed: pre-adsorption of the hydrophobic counter ions to the hydrophobic stationary phase followed by interaction with the ionic analyte, or ion pairing in solution with subsequent sorption of the paired species to the hydrophobic surface. There is evidence that both mechanisms contribute to ionic retention and separations. In this work, ion interactions at a C18 stationary phase interface are investigated by confocal Raman microscopy of individual stationary-phase particles, which is capable of quantifying surface concentrations of surfactants and model solutes. Raman spectra taken within the interior of the particle indicate that pre-adsorption of the hydrophobic surfactant cetylpyridinium to the stationary phase interface is sensitive to ionic strength and concentration of organic modifier in the mobile phase. Furthermore, it was also determined that the presence of low concentrations of a model, ionic solute, nitrobenzenesulfonate, leads to greater adsorption of cetylpyridinium ion at the hydrophobic interface. As the concentration of nitrobenzenesulfonate is increased, the 1:1 increase in the cetylpyridinium-ion interfacial concentration provides evidence of ion pairs forming at the stationary phase surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A subambient pressure ionization with nanoelectrospray (SPIN) source and interface for improved sensitivity in mass spectrometry

Subambient Pressure Ionization with Nanoelectrospray (SPIN), an electrospray ionization source that operates at 30 Torr inside the first vacuum chamber of a mass spectrometer, has been demonstrated for reversed-phase liquid chromatography-mass spectrometry analysis of a protein tryptic digest solution. A 5–12-fold improvement in sensitivity relative to a standard atmospheric pressure ESI source was observed for a variety of detected peptides. The low liquid chromatographic flow rate (300 nL/min) allowed stable electrospray to be established before the onset of electrical discharge, and the higher operating pressure of the SPIN source relative to previous low-pressure ESI source designs prevented the solvents from freezing. The range of accessible flow rates for the SPIN source was also extended to 2.5 μL/min by using an array of electrospray emitters that divided the flow to 6 discrete electrosprays.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Annotation of Untargeted Metabolomics Data through Buffer Modifications That Shift Adduct Mass and Intensity

Annotation of untargeted high-resolution full-scan LC-MS metabolomics data remains challenging due to individual metabolites generating multiple LC-MS peaks arising from isotopes, adducts and fragments. Adduct annotation is a particular challenge, as the same mass difference between peaks can arise from adduct formation, fragmentation, or different biological species. To address this, here we describe a Buffer Modification Workflow (BMW), in which the same sample is run by LC-MS in both liquid chromatography solvent with 14 NH 3 -acetate buffer, and in solvent with the buffer modified with 15 NH 3 -formate. Buffer switching results in characteristic mass and signal intensity changes for adduct peaks, facilitating their annotation. This relatively simple and convenient chromatography modification annotated yeast metabolomics data with similar effectiveness to growing the yeast in isotope-labeled media. Application to mouse liver data annotated both known metabolite and known adduct peaks with 95% accuracy. Altogether, it identified 26% of ~ 27,000 liver LC-MS features as putative metabolites, of which ~ 2600 showed HMDB or KEGG database formula match. This workflow is well-suited to biological samples that cannot be readily isotope labeled, including plants, mammalian tissues, and tumors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

Development of a Universal Second-Tier Newborn Screening LC–MS/MS Method for Amino Acids, Lysophosphatidylcholines, and Organic Acids

First-tier MS-based newborn screening by flow injection analysis can have high presumptive positive rates, often due to isomeric/isobaric compounds or poor biomarker specificity. These presumptive positive samples can be analyzed by second-tier screening assays employing separations such as liquid chromatography–mass spectrometry (LC–MS/MS), which increases test specificity and drastically reduces false positive referrals. The ability to screen for multiple disorders in a single multiplexed test simplifies workflows and maximizes public health laboratories’ resources. In this study, we developed and validated a highly multiplexed second-tier method for dried blood spots using a hydrophilic interaction liquid chromatography (HILIC) column coupled to an MS/MS system. The LC–MS/MS method was capable of simultaneously detecting second-tier biomarkers for maple syrup urine disease, homocystinuria, methylmalonic acidemia, propionic acidemia, glutaric acidemia type 1, glutaric acidemia type 2, guanidinoacetate methyltransferase deficiency, short-chain acyl-CoA dehydrogenase deficiency, adrenoleukodystrophy, and Pompe disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical Attribution of Fentanyl Using Multivariate Statistical Analysis of Orthogonal Mass Spectral Data

Attribution of the origin of an illicit drug relies on identification of compounds indicative of its clandestine production and is a key component of many modern forensic investigations. Here, the results of these studies can yield detailed information on method of manufacture, starting material source, and final product, all critical forensic evidence. In the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic fentanyl, N-(1-phenylethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Six synthesis methods, all previously published fentanyl synthetic routes or hybrid versions thereof, were studied in an effort to identify and classify route-specific signatures. A total of 160 distinct compounds and inorganic species were identified using gas and liquid chromatographies combined with mass spectrometric methods (gas chromatography/mass spectrometry (GC/MS) and liquid chromatography–tandem mass spectrometry-time of-flight (LC–MS/MS-TOF)) in conjunction with inductively coupled plasma mass spectrometry (ICPMS). The complexity of the resultant data matrix urged the use of multivariate statistical analysis. Using partial least-squares-discriminant analysis (PLS-DA), 87 route-specific CAS were classified and a statistical model capable of predicting the method of fentanyl synthesis was validated and tested against CAS profiles from crude fentanyl products deposited and later extracted from two operationally relevant surfaces: stainless steel and vinyl tile. Finally, this work provides the most detailed fentanyl CAS investigation to date by using orthogonal mass spectral data to identify CAS of forensic significance for illicit drug detection, profiling, and attribution.

36 MATERIALS SCIENCE↗

Autonomous METLIN-Guided In-source Fragment Annotation for Untargeted Metabolomics

Computational metabolite annotation in untargeted profiling aims at uncovering neutral molecular masses of underlying metabolites and assign those with putative identities. Existing annotation strategies rely on the observation and annotation of adducts to determine metabolite neutral masses. However, a significant fraction of features usually detected in untargeted experiments remains unannotated, which limits our ability to determine neutral molecular masses. Despite the availability of tools to annotate, relatively few of them benefit from the inherent presence of in-source fragments in liquid chromatography-electrospray ionization-mass spectrometry. Here, we introduce a strategy to annotate in-source fragments in untargeted data using low-energy tandem mass spectrometry (MS) spectra from the METLIN library. Our algorithm, MISA (METLIN-guided in-source annotation), compares detected features against low-energy fragments from MS/MS spectra, enabling robust annotation and putative identification of metabolic features based on low-energy spectral matching. The algorithm was evaluated through an annotation analysis of a total of 140 metabolites across three different sets of biological samples analyzed with liquid chromatography-mass spectrometry. Results showed that, in cases where adducts were not formed or detected, MISA was able to uncover neutral molecular masses by in-source fragment matching. MISA was also able to provide putative metabolite identities via two annotation scores. These scores take into account the number of in-source fragments matched and the relative intensity similarity between the experimental data and the reference low-energy MS/MS spectra. Overall, results showed that in-source fragmentation is a highly frequent phenomena that should be considered for comprehensive feature annotation. Thus, combined with adduct annotation, this strategy adds a complementary annotation layer, enabling in-source fragments to be annotated and increasing putative identification confidence. The algorithm is integrated into the XCMS Online platform and is freely available at http://xcmsonline.scripps.edu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human Microdosing with Carcinogenic Polycyclic Aromatic Hydrocarbons: In Vivo Pharmacokinetics of Dibenzo[ def,p ]chrysene and Metabolites by UPLC Accelerator Mass Spectrometry

Metabolism is a key health risk factor following exposures to pro-carcinogenic polycyclic aromatic hydrocarbons (PAHs) such as dibenzo[def,p]chrysene (DBC), an IARC classified 2A probable human carcinogen. Human exposure to PAHs occurs primarily from the diet in non-smokers. However, little data is available on the metabolism and pharmacokinetics in humans of high molecular weight PAHs (≥4 aromatic rings), including DBC. We previously determined the pharmacokinetics of DBC in human volunteers orally administered a micro-dose (29 ng; 5 nCi) of [14C]-DBC by accelerator mass spectrometry (AMS) analysis of total [14C] in plasma and urine. In the current study, we utilized a novel “moving wire” interface between ultra-performance liquid chromatography (UPLC) and AMS to detect and quantify parent DBC and its major metabolites. The major [14C] product identified in plasma was unmetabolized [14C]-DBC itself, (Cmax= 18.5 ± 15.9 fg/mL, Tmax= 2.1 ± 1.0 h), whereas the major metabolite was identified as [14C]-(+/-)-DBC-11,12-diol (Cmax= 2.5 ± 1.3 fg/mL, Tmax= 1.8 h). Several minor species of [14C]-DBC metabolites were also detected for which no reference standards were available. Free and conjugated metabolites were detected in urine with [14C]-(+/-)-DBC-11,12,13,14-tetraol isomers identified as the major metabolites, 56.3% of which were conjugated (Cmax= 35.8 ± 23.0 pg/pool, Tmax= 6-12 h pool). [14C]-DBC-11,12-diol, of which 97.5% was conjugated, was also identified in urine (Cmax= 29.4 ± 11.6 pg/pool, Tmax= 6-12 h pool). Parent [14C]-DBC was not detected in urine. This is the first dataset to assess metabolite profiles and associated pharmacokinetics of a carcinogenic PAH in human volunteers at an environmentally relevant dose, providing the data necessary for translation of high dose animal models to humans for translation of environmental health risk assessment.

Madeen, Erin P.↗

Conversion of Phenolic Oil from Biomass Pyrolysis into Phenyl Esters

Bio-oil is among the most economical approaches for advanced biofuel production. However, bio-oil faces several challenges including high acidity and viscosity, poor storage, and thermal stability. This study focuses on the upgradation of lignocellulosic (corn stover and yellow pine) bio-oil derived phenolic oil (PO), produced by the autothermal fast pyrolysis, through acid-catalyzed esterification reaction. Our strategy exploits a little recognized chemistry: the Fischer esterification of PO and carboxylic acids into carboxylic acid phenyl esters (CAPE) using Dean Stark distillation. Analyses by the Folin–Ciocalteu method, Karl Fischer titration, gas chromatography flame ionization detector, and the molecular weight determination by gel permeation chromatography suggest the conversion of 50 wt% added phenolics to their corresponding CAPE. The Fourier transform infrared spectroscopy analysis confirmed the formation of new C=O and two C–O stretching bands and decrease in the intensity of phenolic-OH bands in the CAPE. The 13 C NMR analysis supports the formation of CAPE together with some unreacted precursors. A base-catalyzed ester hydrolysis experiment and mass balance calculation show an excellent agreement (within 5% range) of the equivalent weight between the produced ester and the phenyl hexanoate. Brookfield analysis indicates that CAPE has 330-fold lower viscosity than starting PO. Heating values of CAPE were higher than PO, from which they were derived (42.2 and 43.6%, respectively, for PO from pyrolysis of corn stover and yellow pine), while moisture content decreased by 98.3 and 98.7%, respectively. The CAPE, which is a phenolic analogue of methyl esters used in biodiesel, has improved stability compared to PO from which it was derived.

42 ENGINEERING↗

Characterizing PM 2.5 Emissions and Temporal Evolution of Organic Composition from Incense Burning in a California Residence

The chemical composition of incense-generated organic aerosol in residential indoor air has received limited attention in Western literature. In this study, we conducted incense burning experiments in a single-family California residence during vacancy. Here, we report the chemical composition of organic fine particulate matter (PM 2.5 ), associated emission factors (EFs), and gas-particle phase partitioning for indoor semivolatile organic compounds (SVOCs). Speciated organic PM 2.5 measurements were made using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HR-ToF-MS) and semivolatile thermal desorption aerosol gas chromatography (SV-TAG). Organic PM 2.5 EFs ranged from 7 to 31 mg g –1 for burned incense and were largely comprised of polar and oxygenated species, with high abundance of biomass-burning tracers such as levoglucosan. Differences in PM 2.5 EFs and chemical profiles were observed in relation to the type of incense burned. Nine indoor SVOCs considered to originate from sources other than incense combustion were enhanced during incense events. Time-resolved concentrations of these SVOCs correlated well with PM 2.5 mass (R 2 > 0.75), suggesting that low-volatility SVOCs such as bis(2-ethylhexyl)phthalate and butyl benzyl phthalate partitioned to incense-generated PM 2.5 . Both direct emissions and enhanced partitioning of low-volatility indoor SVOCs to incense-generated PM 2.5 can influence inhalation exposures during and after indoor incense use.

54 ENVIRONMENTAL SCIENCES↗

Comprehensive Chemical Characterization of Hydrocarbons in NIST Standard Reference Material 2779 Gulf of Mexico Crude Oil

Comprehensive chemical information is needed to understand the environmental fate and impact of hydrocarbons released during oil spills. However, chemical information remains incomplete because of the limitations of current analytical techniques and the inherent chemical complexity of crude oils. In this study, gas chromatography (GC)-amenable C 9 -C 33 hydrocarbons were comprehensively characterized from the National Institute of Standards and Technology Standard Reference Material (NIST SRM) 2779 Gulf of Mexico crude oil by GC coupled to vacuum ultraviolet photoionization mass spectrometry (GC/VUV-MS), with a mass balance of 68 ± 22%. This technique overcomes one important limitation faced by traditional GC and even comprehensive 2D gas chromatography (GC×GC): the necessity for individual compounds to be chromatographically resolved from one another in order to be characterized. VUV photoionization minimizes fragmentation of the molecular ions, facilitating the characterization of the observed hydrocarbons as a function of molecular weight (carbon number, N C ), structure (number of double bond equivalents, N DBE ), and mass fraction (mg kg -1 ), which represent important metrics for understanding their fate and environmental impacts. Linear alkanes (8 ± 1%), bran ched alkanes (11 ± 2%), and cycloalkanes (37 ± 12%) dominated the mass with the largest contribution from cycloalkanes containing one or two rings and one or more alkyl side chains (27 ± 9%). Linearity and good agreement with previous work for a subset of >100 components and for the sum of compound classes provided confidence in our measurements and represents the first independent assessment of our analytical approach and calibration methodology. Another crude oil collected from the Marlin platform (35 km northeast of the Macondo well) was shown to be chemically identical within experimental errors to NIST SRM 2779, demonstrating that Marlin crude is an appropriate surrogate oil for researchers conducting laboratory research into impacts of the DeepWater Horizon disaster.

02 PETROLEUM↗

Solvent Selection for the Separation of Lignin-Derived Monomers Using the Conductor-like Screening Model for Real Solvents

The separation of desired monomers from a liquid-phase mixture of lignin depolymerization products is necessary to facilitate their upscaling and upgrading for industrial applications. One effective method to separate multiple liquid-phase products is countercurrent chromatography (CCC), which is a common liquid chromatography technique that separates target solutes based on differences in their partitioning in a biphasic solvent system. Effective CCC separation requires the selection of solvent compositions to tune solute partition coefficients. Here, to alleviate the experimental burden of selecting optimal solvent systems, we apply the conductor-like screening model for real solvents (COSMO-RS) method to compute partition coefficients of representative lignin monomers from four currently used depolymerization strategies in standard solvent systems. We further design new ternary and quaternary solvent systems that are predicted to further improve separation efficacy. On the basis of these predicted partition coefficients and empirical solvent selection criteria for CCC measurements, we suggest a range of solvent systems that would be suitable for the effective separation of aromatic lignin-derived products via CCC or similar liquid–liquid extraction methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗