Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Techno-Economic Analysis of Data-Driven and Transactive Approaches for Resilience Enhancement

As extreme weather events lead to more frequent power outages, understanding and enhancing grid resilience is critical to mitigating economic losses and non-energy impacts from service disruptions. Here, this study introduces a novel techno-economic analysis framework for evaluating resilience enhancement mechanisms. The framework combines grid response modeling with a co-simulation approach and valuation methodology to provide a comprehensive assessment. We apply this framework to a realistic case study of the Texas grid during Winter Storm Uri in February 2021. Two advanced resilience strategies are analyzed: a data-driven rolling outage mechanism and a transactive energy (TE) based allocation scheme. The rolling outage scheme selectively serves customers based on real-time curtailment needs, while the TE scheme allows customers to trade energy allocations according to their preferences. Our findings show that both the rolling outage and TE schemes significantly outperform conventional methods (i.e. controlled outages) by reducing the amount of energy not supplied to customers by 41% and 64%, respectively. These approaches also enhance flexibility and customer satisfaction, while improving energy utilization for greater resilience. Additionally, they maintain thermal comfort about 3.5 times better and substantially lower customer risk exposure. A key contribution of this study is addressing both utility and customer perspectives while considering both energy and non-energy impacts. The techno-economic analysis indicates that implementing these resilience enhancement strategies would incur an additional 1.1Bto1.6B in utility costs but has the potential to avoid 17.3Bto18B of customer losses as compared to existing solutions, thereby underscoring the value of investing in advanced resilience, as it provides significant societal benefits to customers.

42 ENGINEERING↗

Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions

Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human-Machine Shared Control for Path Following Considering Driver Fatigue Characteristics

Fatigue driving has been regarded as one of the most important factors that cause traffic accidents. This paper proposes a robust human-machine shared control strategy to improve the vehicle performance for different driver fatigue states. Firstly, the time-varying driver steering model is proposed to address the model mismatch caused by fatigue driving. And the driver fatigue evaluation system is established based on facial features to quantify driver fatigue levels. Based on the quantified fatigue levels, a novel strategy for allocating authorities of the driver and controller is developed for building the driver-vehicle interaction system. Then, to weaken the influence of parameter perturbations caused by the time-varying driver states, we design a fatigue-based shared controller through state feedback. The actuator saturation and system constraints are considered in the controller design through the robust set-invariance property to improve vehicle safety and driving comfort. The driver-in-the-loop platform is conducted to validate the effectiveness of the proposed shared steering controller. In conclusion, the experimental results show that the proposed strategy can adaptively optimize the human-machine authorities according to fatigue states and comprehensively improve vehicle performance.

97 MATHEMATICS AND COMPUTING↗

A Human-Machine Shared Control Framework Considering Time-Varying Driver Characteristics

The uncertainties of driver's behavior seriously affect road safety and bring significant challenges to the human-machine cooperative control. Here, this paper proposes a human-machine shared control framework considering driver's time-varying characteristics to improve the co-driving cooperation performance. Firstly, the driving intention is introduced to describe the driver's involvement level through using Gauss-Bernoulli restricted Boltzmann machine method. And the index of driving ability is proposed to evaluate driver skills based on path-tracking errors. Then, a novel human-machine authority allocation strategy is designed by combining the two driving behavior characteristics and used to construct the driver-vehicle interaction system. Subsequently, a T-S fuzzy robust state-feedback shared control system is developed considering time-varying driver behaviors and vehicle states. Finally, the proposed shared steering system is validated by the driver-in-the-loop test bench. The results show that the proposed control method can reduce human-machine conflicts and has obvious superiority in improving performance of driving comfort, path tracking, and vehicle stability for the co-driving vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

An Evaluation of the Water Heater Load Potential for Providing Regulation Service

This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users’ water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part II: Results and Performance Evaluation

This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. We developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation in Part I. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Lastly, our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Scalable and Distributed Algorithm for Managing Residential Demand Response Programs using Alternating Direction Method of Multipliers (ADMM)

For effective engagement of residential demand-side resources and to ensure efficient operation of distribution networks, we must overcome the challenges of controlling and coordinating residential components and devices at scale. To overcome this challenge, we present a distributed and scalable algorithm with a three-level hierarchical information exchange architecture for managing the residential demand response programs. First, a centralized optimization model is formulated to maximize community social welfare. Then, this centralized model is solved in a distributed manner with alternating direction method of multipliers (ADMM) by decomposing the original problem to utility-level and house-level problems. The information exchange between the different layers is limited to the primary residual (i.e., supply-demand mismatch), Lagrangian multipliers, and the total load of each house to protect each customer’s privacy. Simulation studies are performed on the IEEE 33 bus test system with 605 residential customers. The results demonstrate that the proposed approach can save customers’ electricity bills and reduce the peak load at the utility level without much affecting customers’ comfort and privacy. Finally, a quantitative comparison of the distributed and centralized algorithms shows the scalability advantage of the proposed ADMM-based approach, and it gives benchmarking results with achievable value for future research works.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Influence of Visual Provenance Representations on Strategies in a Collaborative Hand-off Data Analysis Scenario

Conducting data analysis tasks rarely occur in isolation. Especially in intelligence analysis scenarios where different experts contribute knowledge to a shared understanding, members must communicate how insights develop to establish common ground among collaborators. The use of provenance to communicate analytic sensemaking carries promise by describing the interactions and summarizing the steps taken to reach insights. Yet, no universal guidelines exist for communicating provenance in different settings. Our work here focuses on the presentation of provenance information and the resulting conclusions reached and strategies used by new analysts. In an open-ended, 30-minute, textual exploration scenario, we qualitatively compare how adding different types of provenance information (specifically data coverage and interaction history) affects analysts' confidence in conclusions developed, propensity to repeat work, filtering of data, identification of relevant information, and typical investigation strategies. We see that data coverage (i.e., what was interacted with) provides provenance information without limiting individual investigation freedom. On the other hand, while interaction history (i.e., when something was interacted with) does not significantly encourage more mimicry, it does take more time to comfortably understand, as represented by less confident conclusions and less relevant information-gathering behaviors. In conclusion, our results contribute empirical data towards understanding how provenance summarizations can influence analysis behaviors.

97 MATHEMATICS AND COMPUTING↗

Re-Evaluating Virtual Reality Manipulation Techniques for Precise Alignment of Complex 3D Objects

Prior research has developed a number of manipulation techniques that can achieve precise object placement in virtual reality, but studies of these techniques typically use simple objects. We conducted a study comparing two existing techniques, (AMP-IT and WISDOM), during alignment of objects with complex geometry to evaluate the potential influence of geometric complexity on performance, usability, workload and preference. Our findings indicate that participants had faster completion times and higher trial completion rates with AMP-IT on high-precision alignment tasks, contrary to earlier findings that used simple objects. Yet WISDOM is still preferred and considered more usable, despite increased workload and poorer performance, exposing participants' willingness to trade objective performance for comfort during use.

97 MATHEMATICS AND COMPUTING↗

Control of airborne infectious disease in buildings: Evidence and research priorities

The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Finally, improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of a Respirator Vortex Cooling Device

The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. Finally, the statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

47 OTHER INSTRUMENTATION↗

Co-Optimization of Velocity and Charge-Depletion for Plug-In Hybrid Electric Vehicles: Accounting for Acceleration and Jerk Constraints

Abstract Recent advances in vehicle connectivity and automation technologies promote advanced control algorithms that co-optimize the longitudinal dynamics and powertrain operation of hybrid electric vehicles. Typically, a sequential optimization with the vehicle dynamics optimized followed by powertrain optimization is adopted to manage a number of complexities such as the inherent mixed-integer nature of the hybrid powertrain, the numerous state and control variables, the differing time scales of vehicle and powertrain subsystems, time-varying state constraints, and large horizon lengths. Instead, we solve the offline optimization problem in a centralize manner assuming exact knowledge of the lead vehicle's position over the entire trip by applying a discrete-time single shooting-based numerical approach, Discrete Mixed-Integer Shooting (DMIS), including a linearly increasing computational complexity to the problem horizon. In particular, the hierarchical problem structure is exploited to decompose the computationally intensive Hamiltonian minimization step into a set of low-dimensional optimizations. DMIS allows us to compute the direct fuel minimization problem including the vehicle and powertrain dynamics in a centralized manner to its full horizon while systematically tuning weighting factors that penalize passenger discomfort. For the first time, this study reveals that practically implemented sequential optimization exhibits similar fuel optimality as co-optimization when a certain level of passenger comfort is required.

Automation & Control Systems↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Special Issue: Thermal Energy Storage for Buildings

This special issue (SI) of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) features peer-reviewed papers specific to technologies and applications of thermal energy storage (TES) for buildings. TES systems store energy in materials as a heat source or a cold sink and then discharge the stored energy hours or weeks later to enhance thermal comfort or reduce utility bills [1]. As buildings and cities are facing increasing energy consumption and extreme weather events, TES offers a powerful solution to balance supply and demand, reduce operational energy costs, and strengthen energy resilience during power outages.

25 ENERGY STORAGE↗

Novel Functional Thermal Energy Storage Materials for Buildings Applications

The leakage of solid-liquid phase change materials (PCMs) tremendously limits their long-term application in thermal energy storage (TES). In this work, we present durable and form-stable shape-stabilized PCMs (ss-PCMs) for TES in building envelopes. These ss-PCMs are fabricated by encapsulating polyethylene glycol (PEG) consisting of different molecular weights within mesoporous magnesium oxide and silica dioxide. For the first time, the phase transition temperature (Tt) of ss-PCMs has been fine-tuned synthetically to be comfortable to building occupants by utilizing PEG blends with molecular weights of 600 and 800 g/mol. Several parameters, including surface hydrophilicity/hydrophobicity, surface area, and PCM loading percentage, have been studied to maximize the latent heat enthalpy for high energy efficiency and maintain form stability. The best ss-PCM candidate with suitable Tt and appreciable latent heat enthalpy exhibits a repeatable phase change behavior for up to 1,000 thermal cycles without leakage, which provides a promising solution for durable TES in buildings. The Tt tunability extends its application over a wider temperature range beyond buildings.

building envelope↗

PET/CT in radiation oncology

PET/CT is an effective tool for the diagnosis, staging and restaging of cancer patients. It combines the complementary information of functional PET images and anatomical CT images in one imaging session. Conventional stand-alone PET has been replaced by PET/CT for improved patient comfort, patient throughput, and most importantly the proven clinical outcome of PET/CT over that of PET and that of separate PET and CT. There are over two thousand PET/CT scanners installed worldwide since 2001. Oncology is the main application for PET/CT. Fluorine-18 deoxyglucose is the choice of radiopharmaceutical in PET for imaging the glucose uptake in tissues, correlated with an increased rate of glycolysis in many tumor cells. New molecular targeted agents are being developed to improve the accuracy of targeting different disease states and assessing therapeutic response. Over 50% of cancer patients receive radiation therapy (RT) in the course of their disease treatment. Clinical data have demonstrated that the information provided by PET/CT often changes patient management of the patient and/or modifies the RT plan from conventional CT simulation. The application of PET/CT in RT is growing and will become increasingly important. Continuing improvement of PET/CT instrumentation will also make it easier for radiation oncologists to integrate PET/CT in RT. The purpose of this article is to provide a review of the current PET/CT technology, to project the future development of PET and CT for PET/CT, and to discuss some issues in adopting PET/CT in RT and potential improvements in PET/CT simulation of the thorax in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam hardening effect. Conclusions: The results showed that a CT system using an energy resolving detector reduces the dose to the patient while maintaining image quality for various breast imaging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗