Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

An experimental investigation of the flow in a diffusing S-duct

Compressible, subsonic flow through a diffusing S-duct has been experimentally investigated. Benchmark aerodynamic data are presented for flow through a representative S-duct configuration. The collected data would be beneficial to aircraft inlet designers and is suitable for the validation of computational codes. Measurements of the 3D velocity field and total and static pressures were obtained at five cross-sectional planes. Surface static pressures and flow visualization also helped to reveal flow field characteristics. All reported tests were conducted with an inlet centerline Mach number of 0.6 and a Reynolds number, based on the inlet centerline velocity and duct inlet diameter, of 2.6 x 10(exp 6). The results show that a larger region of streamwise flow separation occurred within the duct. Details about the separated flow region, including mechanisms which drive this complicated flow phenomenon, are discussed. Transverse velocity components indicate that the duct curvature induces strong pressure driven secondary flows, which evolve into a large pair of counter-rotating vortices. These vortices convect the low momentum fluid of the boundary layer towards the center of the duct, degrading both the uniformity and magnitude of the total pressure profile.

Wellborn, Steven R.↗

Assessment of the pharmacodynamics of intranasal, intravenous and oral scopolamine

Space motion sickness is an important issue in the space medical sciences program. One of the objectives of the ongoing clinical experimental protocol Pharmacokinetics of Intranasal Scopolamine in Normal Subjects is to evaluate the pharmacodynamics of scopolamine using salivary flow rate and pH profiles and cognitive performance tests as pharmacodynamic parameters. Normal volunteers collected saliva and performed the NTI Multiresource Performance Battery tests at designed time intervals to establish control saliva flow rates, salivary pH profiles, and the characteristics of the learning curve for the performance program under normal conditions. In the clinical part of the study, saliva samples and performance test scores are collected from healthy nonsmoking subjects after receiving a single 0.4 mg dose of either intranasal, intravenous, or oral scopolamine.

Tietze, Karen J.↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Flow Past a Tilted Vena Cava Filter

Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside a model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.

42 ENGINEERING↗

A multi-channel gel electrophoresis and continuous fraction collection apparatus for high throughput protein separation and characterization

To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A Counter Free-Flow elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high-resolution separation of a complex protein mixture can be achieved on this system using SDS-PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48-96 fractions over a mass range of 10-150 kDa; sample recovery rates were 50percent or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 L/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 g per channel and reduced resolution.

60 APPLIED LIFE SCIENCES↗

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter). All Fluid Management Plan requirements were met.

54 ENVIRONMENTAL SCIENCES↗

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 1

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter) for a portion of the Tertiary volcanic section near the water table. Tritium concentrations were at or near the field detection limit in the Lower carbonate aquifer (LCA) while drilling. During drilling, a sample was collected while circulating in the LCA. The sample was submitted for off-site laboratory analysis. The sample results indicated low but measurable tritium concentrations. All Fluid Management Plan requirements were met during drilling activities.

54 ENVIRONMENTAL SCIENCES↗

Field Measurements at River and Tidal Current Sites for Hydrokinetic Energy Development: Best Practices Manual

In this report, existing data collection techniques and protocols for characterizing open channel flows are reviewed and refined to further address the needs of the MHK industry. The report provides an overview of the hydrodynamics of river and tidal channels, and the working principles of modern acoustic instrumentation, including best practices in remote sensing methods that can be applied to hydrokinetic energy site characterization. Emphasis is placed upon acoustic Doppler velocimeter (ADV) and acoustic-Doppler current profiler (ADCP) instruments, as these represent the most practical and economical tools for use in the MHK industry. Incorporating the best practices as found in the literature, including the parameters to be measured, the instruments to be deployed, the instrument deployment strategy, and data post-processing techniques. The data collected from this procedure aims to inform the hydro-mechanical design of MHK systems with respect to energy generation and structural loading, as well as provide reference hydrodynamics for environmental impact studies. The standard metrics and protocols defined herein can be utilized to guide field experiments with MHK systems.

13 HYDRO ENERGY↗

Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically we investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.

holding time↗

Hydrological and Thermal Dynamics of a Supra‐Permafrost Subterranean Estuary

Subterranean estuaries (STEs), where groundwater interacts with seawater, influence surface and subsurface coastal ecology and biogeochemistry. In Arctic-STEs overlying permafrost, groundwater flow and heat transport determine the fate of organic matter. Yet, direct observations of groundwater flow and heat and solute transport processes in Arctic STEs remain limited. This study characterized groundwater flow paths and fluxes and heat transport within an Arctic-STE along Alaska's Beaufort Sea coast during thawing, summer, and freeze-up. Intertidal seabed temperature-depth profiles collected along a 10-m transect captured the active groundwater flow period, from thaw and flow onset in mid-June to freeze-up in late-September. During this period, aquifer geometry evolved non-uniformly due to spatially varying thaw rates across the STE (mean (m) thaw depths–beach: 0.25 to 0.55–0.6 m on 20 June, 25 July, 1 October; seabed: 0.6–0.9 m from 25 July to 1 October). Groundwater and surface water levels, salinity, and subsurface temperature profiles measured over tidal time scales were interpreted alongside groundwater flow-heat transport numerical simulations. Fresh groundwater discharge was sporadic during thawing (m: 0.32 m 3 /day/m), abundant in summer (m: 0.45 m 3 /day/m), and was largely absent during freeze-up. During freeze-up, groundwater flow was driven exclusively by seawater recirculation via tidal pumping (from thawing to summer to freeze-up: 0.00025–0.15–0.5 m3/day/m) and convection. Heat advection dominated near aquatic interfaces (shaping intertidal ice), and conduction controlled vertical temperature gradients in low-flow and unsaturated sediments. These findings will help predict how prolonged summers will alter Arctic-STE cryo-hydrology and biogeochemistry.

54 ENVIRONMENTAL SCIENCES↗

Deep learning assisted jet tomography for the study of Mach cones in QGP

Abstract Mach cones are expected to form in the expanding quark-gluon plasma (QGP) when energetic quarks and gluons traverse the hot medium at a velocity faster than the speed of sound in high-energy heavy-ion collisions. The shape of the Mach cone and the associated diffusion wake are sensitive to the initial jet production location and the propagation direction of the parton shower relative to the radial flow because of the distortion caused by the collective expansion of the QGP and the large density gradient. The shape of jet-induced Mach cones and their distortions in heavy-ion collisions provide a unique and direct probe of the dynamical evolution and the equation of state of QGP. However, it is difficult to identify the Mach cone and the diffusion wake in current experimental measurements of final hadron distributions because they are averaged over all possible initial jet production locations and parton-shower propagation directions. To overcome this difficulty, we develop a deep learning assisted jet tomography which uses the full information of the final hadrons from jets to localize the initial jet production positions. This method can help to constrain the initial regions of jet production in heavy-ion collisions and enable a differential study of Mach-cones with different path lengths and orientations relative to the radial flow of the QGP in heavy-ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pahute Mesa-Oasis Valley Hydrostratigraphic Framework Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada (Rev. 0)

A new, revised three-dimensional (3-D) hydrostratigraphic framework model (HFM) for the Central and Western Pahute Mesa Corrective Action Units 101 and 102 was completed in 2019. The initial (Phase I) model was completed in 2002 and was documented in A Hydrostratigraphic Model and Alternatives for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada (BN, 2002). Subsequent flow and transport modeling revealed the need to collect additional data to reduce uncertainties. The Phase II data collection and characterization effort included extensive well drilling and testing activities, and rebuilding of the Phase I 3-D HFM, resulting in the Phase II HFM (NSTec, 2014). Further drilling (Well ER-20-12), data collection, and interpretive work (e.g., Thirsty Canyon Lineament [Wurtz and Day, 2018]) were incorporated into the Pahute Mesa-Oasis Valley (PM-OV) HFM. The PM-OV HFM incorporates the area of interest from the Phase II HFM and adds additional areas, primarily to the north and west with minor additions to the south and east. The new, expanded area matches the PM-OV groundwater basin as defined in Fenelon et al. (2016) and includes Pahute Mesa, a former nuclear testing area at the Nevada National Security Site; and Oasis Valley, a groundwater discharge area downgradient from contaminant source areas on Pahute Mesa. The data and information necessary to build the PM-OV HFM are provided in Navarro (2019). The PM-OV HFM will be used by hydrologic modelers who are tasked with developing a model to determine how contaminants are transported by groundwater flow in an area of complex geology. The model area is large (more than 6,250 square kilometers) and geologically complex, including Paleozoic- to Mesozoic-age structures (e.g., thrust faults, Thirsty Canyon Lineament), at least seven Tertiary-age calderas, several intrusive bodies, and many relatively recent basin-and-range normal faults. Investigators from the U.S. Geological Survey; National Security Technologies, LLC; National Laboratories; and U.S. Department of Energy contractors have organized the more than 300 volcanic units and other rocks in the model area into 77 hydrostratigraphic units (HSUs). The volcanic rocks are subdivided into 42 aquifers, 11 confining units, and 9 composite units (containing both aquifer and confining unit rocks). The underlying pre-Tertiary rocks were divided into 5 HSUs, comprising 2 aquifers and 3 confining units. The model also includes 1 alluvial aquifer unit, 8 intrusive confining units, and 1 granite confining unit. The model depicts the thickness, extent, and geometric relationships of these HSUs (“layers” in the model) along with all the major structural features that control them, including calderas and faults. The most substantive differences between the Phase II HFM and the PM-OVHFM include (1) addition of the new data and resulting revised interpretations from the additional area encompassed by the PM-OV groundwater basin; (2) incorporation of 16 new faults; (3) 12 boreholes from the northern extension; (4) 2 additional caldera-collapse collars; and (5) correlation of the simulated faulting and hydrostratigraphy in the eastern part of the model domain with the delineations represented in the neighboring Rainier Mesa-Shoshone Mountain HFM-Prime and Yucca Flat-Climax Mine HFM. All PM-OV HFM delineations were based on published and unpublished data from geophysical investigations, surface geologic maps, and drill-hole records. Phase II approached model uncertainty using the model-building software to test model configurations and hydrologic consequences using a range of values for parameters such as fault offset amounts and HSU elevations. The PM-OV HFM expands on this approach to encompass the entire PM-OV groundwater basin.

54 ENVIRONMENTAL SCIENCES↗

Occurrence of perched saturation and interflow over an argillic horizon in a low relief hillslope.

Abstract. Many of the soils in the south-eastern US are characterized by an argillic, or clay horizon, that largely parallels the soil surface at depths ranging from a few centimeters to 100 cen-timeters. The degree to which these argillic horizons alter subsurface movement of infiltrated water is not well known. Interflow, or throughflow, is shallow lateral subsurface flow that moves over a horizon that restricts percolation. This research investigates how often and under what conditions a relatively deep (20-150+cm) argillic horizon on low slope (2-6%) hillsides causes interflow to oc-cur. Research is being conducted at the Savannah River Site, Aiken, South Carolina, on a small zero-order watershed. In the first phase of this research, a high resolution topographic map of the clay layer was developed. This map will be used to instrument designated “low” spots with max rise piezo-meters in order to determine if there is channelized subsurface flow. In situ conductivities of the clay layer and the surface horizons were measured using an Amoozegar meter, and bulk density samples were taken and measured. Along with soil topographic measurements, data-logging piezometers have been installed to measure the piezometric head above, in, and below the argillic horizon to further investigate interflow as a potential hydraulic routing mechanism. The stream that drains the catchment was instrumented with a 2’ H flume and data-logging pressure transducer to measure stream flow. Climate data including precipitation, barometric pressure and temperature, are being continuously collected in an open area approximately ¼ mile from the study site. Combining the shallow surface and subsurface piezometric heads with stream flow rates, we should be able to determine if and when the clay layer is contributing to inter-flow.

60 APPLIED LIFE SCIENCES↗

Spatial and temporal variations of the ion velocity measured in the Venus ionosphere

Temporal and spatial deviations of ion velocity from the dominant flow of the Venusian ionosphere were detected in data collected from a retarding potential analyzer (RPA) aboard the Pioneer-Venus orbiter spectrometer. The ion velocity measurements were analyzed for the first 3.5 Venus years of the Pioneer-Venus mission, approximately through orbit 780. The deviations of ion velocity from the dominant velocity of the Venusian ionosphere, which generally flows nightward and is almost symmetric about the sun-Venus axis, affect both the ionospheric structure and dynamics. Two examples of departure from steady symmetric flow that were measured by the RPA are discussed.

Miller, K. L.↗

An experimental study on fish attraction using a fish barge model

Fish-collection and transportation systems (FCTS) have been introduced and applied as innovative approaches to facilitate fish passage in China for several years. The efficacy of FCTSs depends directly on the efficiency of the fish-guidance measures employed. In this study, the effects of three parameters—water flow, artificial lighting, and bubble curtains—on the attraction of mosquitofish ( Gambusia affinis ) was investigated using a fish barge model in a large pond. The experiment was conducted in two steps. First, a univariate experiment was performed, and then, a multivariate experiment using an orthogonal design was performed. Four different colors of light were tested: 1) yellow light (570 nm), 2) blue light (460 nm), 3) warm white light (3000 K), and 4) a weak light control group, whose illuminance belongs to the interval 0.001 lx to 0.3 lx. Supplementing water flow within the barge decreased the number of attracted fish (i.e., the number of the targeted fish species that appeared within 1.5m of the barge model’s entrance) but increased the fish-collection ratio of the fish-collecting platform (i.e., the ratio of the number of attracted fish to the number of collected fish). Warm white light was shown to be significantly effective in attracting fish, while no obvious effect was observed in terms of the fish collection ratio. The bubble curtain exhibited excellent fish-attraction efficacies, but also had no significant effect on the attraction and collection efficacy of the fish-collecting platform. During the day, the optimal combination for fish attraction was to have no water flow with a bubble curtain, while the optimal combination for fish collection was to have no water flow and no bubble curtain. During the night, the optimal combination for fish attraction was to have no water flow, no bubble curtain, and a warm white light, while the optimal combination for fish collection was to have water flow, no bubble curtain, and a weak light. This study tested the combined efficacies of various fish-guidance measures on a fish-collecting platform, thus providing experimental support for optimizing various fish-attraction measures and the application of these measures in FCTS projects.

Lin, Chenyu↗

A microgravity boiling and convective condensation experiment

A boiling and condensing test article consisting of two straight tube boilers, one quartz and one stainless steel, and two 1.5 m long glass-in-glass heat exchangers, on 6 mm ID and one 10 mm ID, was flown on the NASA KC-135 0-G aircraft. Using water as the working fluid, the 5 kw boiler produces two phase mixtures of varying quality for mass flow rates between 0.005 and 0.1 kg/sec. The test section is instrumented at eight locations with absolute and differential pressure transducers and thermocouples. A gamma densitometer is used to measure void fraction, and high speed photography records the flow regimes. A three axis accelerometer provides aircraft acceleration data (+ or - 0.01G). Data are collected via an analog-to-digital conversion and data acquisition system. Bubbly, annular, and slug flow regimes were observed in the test section under microgravity conditions. Flow oscillations were observed for some operating conditions and the effect of the 2-G pullout prior to the 0-G period was observed by continuously recording data throughout the parabolas. A total fo 300 parabolas was flown.

Kachnik, Leo↗

Electrophoretic Focusing

Electrophoretic focusing is a new method of continuous flow electrophoresis that introduces precision flow control to achieve high resolution separations. The electric field is applied perpendicular to an incoming sample lamina and buffer but also perpendicular to the broad faces of the thin rectangular chamber. A uniform fluid cross-flow then enters and exits the separation chamber through the same broad faces which are porous. A balance is achieved by adjusting either the electric field or the cross-flow so the desired sample fraction with its specific migration velocity encounters an opposing flow of the same velocity. Applying an electric field transverse to the incoming sample lamina and opposing this field with a carefully configured buffer flow, a sample constituent can be selected and focused into a narrow stream for subsequent analysis. Monotonically changing either electric field or buffer cross-flow will yield a scan of all constituents of the sample. Stopping the scan increases the collection time for minor constituents to improve their analysis. Using the high voltage gradients and/or cross-flow to rapidly deflect extraneous sample through the porous screens and into either of the side (purge) chambers, the selected sample is focused in the center plane of the separation chamber and collected without contact or interaction with the separation chamber walls. Results will be presented on the separation of a range of materials including dyes, proteins, and monodisperse polystyrene latexes. Sources of sample dispersion inherent in other electrokinetic techniques will be shown to be negligible for a variety of sample concentrations, buffer properties and operating conditions.

Snyder, Robert S.↗