Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Cyber-Informed Engineering for Nuclear Reactor Digital Instrumentation and Control

As nuclear reactors transition from analog to digital technology, the benefits of enhanced operational capabilities and improved efficiencies are potentially offset by cyber risks. Cyber-Informed Engineering (CIE) is an approach that can be used by engineers and staff to characterize and reduce new cyber risks in digital instrumentation and control systems. CIE provides guidance that can be applied throughout the entire systems engineering lifecycle, from conceptual design to decommissioning. In addition to outlining the use of CIE in nuclear reactor applications, this chapter provides a brief primer on nuclear reactor instrumentation and control and the associated cyber risks in existing light water reactors as well as the digital technology that will likely be used in future reactor designs and applications.

42 ENGINEERING↗

Implementation of new PRODIAG algorithm and simulation-based acceptance test - 219

This paper presents the improvement of an automated-reasoning computer program for nuclear power plant diagnosis, namely PRODIAG. PRODIAG, first developed at the Argonne National Laboratory, uses confluence-based reasoning to perform fault diagnosis in engineering systems that can be described by the conservation laws for mass, energy, and momentum. Therefore, unlike other plant configuration-dependent rule-based diagnosis algorithms, the code is generally applicable to a wide variety of plant configurations by simply replacing the plant instrumentation diagram (PID) database. The need for improvement was raised when the original PRODIAG failed to provide the requisite degree of extensibility and maintainability for new applications. These shortcomings have been addressed through a new code architecture that uses an objected-oriented logic-programming language in place of the original Prolog language and uses an open-source automated reasoning engine in place of the original hardwired rule-evaluation sequence. This paper presents the architecture and implementation details of the code transition. Verification and validation studies were performed for the new PRODIAG, which involved re-running the distinct fault cases defined at the time the code was originally developed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SPECT imaging with resolution recovery

Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Provenance–aware workflow for data quality management and improvement for large continuous scientific data streams

Data quality assessment, management and improvement is integral part of any big data intensive scientific research to ensure accurate, reliable and reproducible science discoveries. The task of maintaining the quality of data, however, is non-trivial and pose a challenge for a program like Department of Energy’s Atmospheric Radiation Measurement (ARM) that collects data from hundreds of instruments across the world,and distributes thousands of streaming data products that are continuously growing in near-real-time in an archive 1.7 Petabyte in size and growing. We present a computational data processing workflow to collect the data quality issue via an easy and intuitive web-based portal that allows reporting of any quality issues for any site, facility or instruments at a granularity down to individual variable in the data files. Portal allows instrument specialists and scientists to provide corrective actions in form of symbolic equation. A parallel processing framework applies the data improvement to large volume of data in efficient parallel environment, while optimizing data transfer and file I/O operations. Corrected files are systematically versioned and archived. A provenance tracking module tracks and records any change made to the data during its entire life cycle which are communicated transparently to the scientific users. Developed in Python using open source technologies, software architecture enables efficient and fast management and improvement of data in an operational data center environment.

Kumar, Jitendra↗

Ultrasonic power measurement system based on acousto-optic interaction

Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Design of a full photon-timing recorder down to 1-ns resolution for fluorescence fluctuation measurements

A photon timing recorder was realized in a field programmable gate array to capture all timing data of photons on multiple channels with down to a 1-ns resolution and to transfer all data to a host computer in real-time through universal serial bus with more than 10 M events/s transfer rate. The main concept is that photon time series can be regarded as a serial communication data stream. This recorder was successfully applied for simultaneous measurements of fluorescence fluctuation and lifetime of near-infrared dyes in solution. This design is not only limited to the fluorescence fluctuation measurement but also applicable to any kind of photon counting experiments in a nanosecond time range because of the simple and easily modifiable design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconductor Electronics: Status and Outlook

Superconductor electronics combines passive and active superconducting components and sometimes normal resistors into functional circuits and systems that also include room-temperature electronics for amplification, power sources, necessary controls, etc., usually computer operated. Furthermore, complete systems include magnetic and electromagnetic shielding, cryogenic enclosures, and increasingly a cryocooler in self-contained units. Components or devices of low or high critical temperature superconductors include inductances (coils), passive transmission lines, resonators, antennae, filters, as well as active elements: Josephson junctions, Josephson oscillators, and superconducting quantum interference devices. Of multiple demonstrated applications, mostly but not only in science and metrology, currently most successful are voltage standards, astronomy detectors and large telescope cameras, instruments for material characterization, and magnetometers for geomagnetic prospecting. Major current efforts concentrate on energy-efficient high-end computing and quantum computing. The outcomes of these efforts are likely to be known in the course of the following decade.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

Advances in in situ/operando techniques for catalysis research: enhancing insights and discoveries

Abstract Catalysis research has witnessed remarkable progress with the advent of in situ and operando techniques. These methods enable the study of catalysts under actual operating conditions, providing unprecedented insights into catalytic mechanisms and dynamic catalyst behavior. This review discusses key in situ techniques and their applications in catalysis research. Advances in in situ electron microscopy allow direct visualization of catalysts at the atomic scale under reaction conditions. In situ spectroscopy techniques like X-ray absorption spectroscopy and nuclear magnetic resonance spectroscopy can track chemical states and reveal transient intermediates. Synchrotron-based techniques offer enhanced capabilities for in situ studies. The integration of in situ methods with machine learning and computational modeling provides a powerful approach to accelerate catalyst optimization. However, challenges remain regarding radiation damage, instrumentation limitations, and data interpretation. Overall, continued development of multi-modal in situ techniques is pivotal for addressing emerging challenges and opportunities in catalysis research and technology.

Chen, Linfeng↗

Mapping structural heterogeneity at the nanoscale with scanning nano-structure electron microscopy (SNEM)

Here, in this work, we explore the use of scanning electron diffraction (also known as 4D-STEM) coupled with electron atomic pair distribution function analysis (ePDF) to understand the local order (structure and chemistry) as a function of position in a complex multicomponent system, a hot rolled, Ni-encapsulated, Zr 65 Cu 17.5 Ni 10 Al 7.5 bulk metallic glass (BMG), with a spatial resolution of 3 nm. We show that it is possible to gain insight into the chemistry and chemical clustering/ordering tendency in different regions of the sample, including in the vicinity of nano-scale crystallites that are identified from virtual dark field images and in heavily deformed regions at the edge of the BMG. In addition to simpler analysis, unsupervised machine learning was used to extract partial PDFs from the material, modeled as a quasi-binary alloy, and map them in space. These maps allowed key insights not only into the local average composition, as validated by EELS, but also a unique insight into chemical short-range ordering tendencies in different regions of the sample during formation. The experiments are straightforward and rapid and, unlike spectroscopic measurements, don’t require energy filters on the instrument. We spatially map different quantities of interest (QoI’s), defined as scalars that can be computed directly from positions and widths of ePDF peaks or parameters refined from fits to the patterns. We developed a flexible and rapid data reduction and analysis software framework that allows experimenters to rapidly explore images of the sample on the basis of different QoI’s. The power and flexibility of this approach are explored and described in detail. Because of the fact that we are getting spatially resolved images of the nanoscale structure obtained from ePDFs we call this approach scanning nano-structure electron microscopy (SNEM), and we believe that it will be powerful and useful extension of current 4D-STEM methods.

36 MATERIALS SCIENCE↗

FEM-BEM coupling methods for Tokamak plasma axisymmetric free-boundary equilibrium computations in unbounded domains

Incorporating boundary conditions at infinity into simulations on bounded computational domains is a repeatedly occurring problem in scientific computing. The combination of finite element methods (FEM) and boundary element methods (BEM) is the obvious instrument, and we adapt here for the first time the two standard FEM-BEM coupling approaches to the free-boundary equilibrium problem: the Johnson–Nédélec coupling and the Bielak–MacCamy coupling. We recall also the classical approach for fusion applications, dubbed according to its first appearance von-Hagenow–Lackner coupling and present the less used alternative introduced by Albanese, Blum and de Barbieri in . We show that the von-Hagenow–Lackner coupling suffers from undesirable non-optimal convergence properties, that suggest that other coupling schemes, in particular Johnson–Nédélec or Albanese–Blum–de Barbieri are more appropriate for non-linear equilibrium problems. Moreover, we show that any of such coupling methods requires Newton-like iteration schemes for solving the corresponding non-linear discrete algebraic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 2 MV Van de Graaff accelerator as a tool for planetary and impact physics research

Investigating the dynamical and physical properties of cosmic dust can reveal a great deal of information about both the dust and its many sources. Over recent years, several spacecraft (e.g., Cassini, Stardust, Galileo, and Ulysses) have successfully characterised interstellar, interplanetary, and circumplanetary dust using a variety of techniques, including in situ analyses and sample return. Charge, mass, and velocity measurements of the dust are performed either directly (induced charge signals) or indirectly (mass and velocity from impact ionisation signals or crater morphology) and constrain the dynamical parameters of the dust grains. Dust compositional information may be obtained via either time-of-flight mass spectrometry of the impact plasma or direct sample return. The accurate and reliable interpretation of collected spacecraft data requires a comprehensive programme of terrestrial instrument calibration. This process involves accelerating suitable solar system analogue dust particles to hypervelocity speeds in the laboratory, an activity performed at the Max Planck Institut fuer Kernphysik in Heidelberg, Germany. Here, a 2 MV Van de Graaff accelerator electrostatically accelerates charged micron and submicron-sized dust particles to speeds up to 80 km s{sup -1}. Recent advances in dust production and processing have allowed solar system analogue dust particles (silicates and other minerals) to be coated with a thin conductive shell, enabling them to be charged and accelerated. Refinements and upgrades to the beam line instrumentation and electronics now allow for the reliable selection of particles at velocities of 1-80 km s{sup -1} and with diameters of between 0.05 {mu}m and 5 {mu}m. This ability to select particles for subsequent impact studies based on their charges, masses, or velocities is provided by a particle selection unit (PSU). The PSU contains a field programmable gate array, capable of monitoring in real time the particles' speeds and charges, and is controlled remotely by a custom, platform independent, software package. The new control instrumentation and electronics, together with the wide range of accelerable particle types, allow the controlled investigation of hypervelocity impact phenomena across a hitherto unobtainable range of impact parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glow-to-arc transition events in H{sub 2}-Ar direct current pulsed plasma: Automated measurement of current and voltage

The glow-to-arc transition phenomena (arcing) observed in plasma reactors used in materials processing was studied through the arcs characteristic current and voltage waveforms. In order to capture these arcs signals, a LABVIEW based automated instrumentation system (ARCVIEW) was developed, including the integration of an oscilloscope equipped with proper current and voltage probes. The system also allows capturing the process parameters at the arc occurrence moments, which were used to map the arcs events conditions. Experiments in H{sub 2}-Ar DC pulsed plasma returned signals data from 215 arcs events, which were analyzed through software routines. According to the results, an anti-arcing system should react in the time order of few microseconds to prevent most of the damage caused by the undesired arcing phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a time-variable nuclear pulser for half life measurements

In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic wave-based structural health monitoring embedded instrument

Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact focusing spectrometer: Visible (1 eV) to hard x-rays (200 keV)

A low-cost spectrometer that covers a wide range of photon energies can be useful to teach spectroscopy, and for simple, rapid measurements of the photon spectrum produced by small plasma devices. The spectrometer here achieves its wide range, nominally from 1 eV to 200 keV, with a series of spherically and cylindrically bent gratings or crystals that all have the same shape and the same radius of curvature; they are complemented by matching apertures and diagnostics on the Rowland circle that serves as the circular part of the spectrometer's vacuum vessel. Spectral lines are easily identified with software that finds their positions from the dispersion of each diffractive element and the known energies of the lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of high temporal resolution Thomson scattering data during a modulated electron cyclotron resonance heating using conditional averaging

This paper provides a software application of the sampling scope concept for fusion research. The time evolution of Thomson scattering data is reconstructed with a high temporal resolution during a modulated electron cyclotron resonance heating (MECH) phase. The amplitude profile and the delay time profile of the heat pulse propagation are obtained from the reconstructed signal for discharges having on-axis and off-axis MECH depositions. The results are found to be consistent with the MECH deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗