Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

System and method for determining stator winding resistance in an AC motor

A system and method for determining stator winding resistance in an AC motor is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of an AC motor. The circuit includes at least one contactor and at least one switch to control current flow and terminal voltages in the AC motor. The system also includes a controller connected to the circuit and configured to modify a switching time of the at least one switch to create a DC component in an output of the system corresponding to an input to the AC motor and determine a stator winding resistance of the AC motor based on the injected DC component of the voltage and current.

42 ENGINEERING↗

Plasma-Material Interface Development for Future Spherical Tokamak-based Devices in NSTX.

The divertor plasma-material interface (PMI) must be able to withstand steady-state heat fluxes up to 10 MW/m{sup 2} (a limit imposed by the present day divertor material and engineering constraints) with minimal material erosion, as well as to provide impurity control and ion density pumping capabilities. In spherical tokamaks (STs), the compact divertor geometry and the requirement of low core electron collisionality n*{sub e} at n{sub e} < 0.5-0.7 n{sub G} (where n{sub G} is the Greenwald density) for increased neutral beam current drive efficiency impose much greater demands on divertor and first-wall particle and heat flux mitigation solutions. In NSTX, divertor heat flux mitigation and impurity control with an innovative 'snowflake' divertor configuration and ion density pumping by evaporated lithium wall and divertor coatings are studied. Lithium coatings have enabled ion density reduction up to 50% in NSTX through the reduction of wall and divertor recycling rates. The 'snowflake' divertor configuration was obtained in NSTX in 0.8-1 MA 4-6 MW NBI-heated H-mode lithium-assisted discharges using three divertor coils. The snowflake divertor formation was always accompanied by a partial detachment of the outer strike point with an up to 50% increase in divertor radiation from intrinsic carbon, the peak divertor heat flux reduction from 3-6 MW/m{sup 2} to 0.5-1 MW/m{sup 2}, and a significant increase in divertor volume recombination. High core confinement was maintained with the snowflake divertor, evidenced by the t{sub E}, W{sub MHD} and the H98(y,2) factors similar to those of the standard divertor discharges. Core carbon concentration and radiated power were reduced by 30-70%, apparently as a result of reduced divertor physical and chemical sputtering in the snowflake divertor and ELMs. In the SFD discharges, the MHD stability of the H-mode pedestal region was altered leading to the re-appearance of medium size (DW/W = 5-10%), Type I, ELMs otherwise suppressed due to lithium conditioning. Fast divertor measurements showed that impulsive particle and heat fluxes due to the ELMs were significantly dissipated in the high magnetic flux expansion region of the snowflake divertor. The snowflake divertor configuration is being combined in experiments with extrinsic deuterium or impurity gas puffing for increased dissipative divertor power losses, additional upper divertor nulls for increased power sharing between the upper and the lower divertors, and lithium coated plasma facing components for large area ion pumping. These efforts are aimed at the development of an integrated PMI for future ST-based devices for fusion development applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anode protection system for shutdown of solid oxide fuel cell system

An Anode Protection Systems for a SOFC system, having a Reductant Supply and safety subsystem, a SOFC anode protection subsystem, and a Post Combustion and slip stream control subsystem. The Reductant Supply and safety subsystem includes means for generating a reducing gas or vapor to prevent re-oxidation of the Ni in the anode layer during the course of shut down of the SOFC stack. The underlying ammonia or hydrogen based material used to generate a reducing gas or vapor to prevent the re-oxidation of the Ni can be in either a solid or liquid stored inside a portable container. The SOFC anode protection subsystem provides an internal pressure of 0.2 to 10 kPa to prevent air from entering into the SOFC system. The Post Combustion and slip stream control subsystem provides a catalyst converter configured to treat any residual reducing gas in the slip stream gas exiting from SOFC stack.

30 DIRECT ENERGY CONVERSION↗

Device to lower NOx in a gas turbine engine combustion system

An emissions control system for a gas turbine engine including a flow-directing structure (24) that delivers combustion gases (22) from a burner (32) to a turbine. The emissions control system includes: a conduit (48) configured to establish fluid communication between compressed air (22) and the combustion gases within the flow-directing structure (24). The compressed air (22) is disposed at a location upstream of a combustor head-end and exhibits an intermediate static pressure less than a static pressure of the combustion gases within the combustor (14). During operation of the gas turbine engine a pressure difference between the intermediate static pressure and a static pressure of the combustion gases within the flow-directing structure (24) is effective to generate a fluid flow through the conduit (48).

33 ADVANCED PROPULSION SYSTEMS↗

Recent Fast Neutron Imaging Measurements with the Fieldable Nuclear Materials Identification System

This paper describes some recent fast neutron imaging measurements of the fieldable nuclear materials identification system (FNMIS) under development by the National Nuclear Security Administration (NNSA-NA-22) for possible future use in arms control and nonproliferation applications. The general configuration of FNMIS has been previously described, and a description of the application-specific integrated circuit (ASIC) electronics designed for FNMIS has been reported. This paper presents initial imaging measurements performed at ORNL with a Thermo Fisher API 120 DT generator and the fast-neutron imaging module of FNMIS.

Wellington, Tracey↗

Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring

Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report by Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.

Hernandez Jimenez, Jarilyn M↗

Configuration of an optical switch fabric using machine learning

An optical switch fabric comprises two or more optical switch elements. The optical switch elements are configured in a topology. A switch control has a plurality of bias control signals. The switch control can address one or more of the optical switch elements and can apply one of the bias control signals to bias of the addressed optical switch element to establish a switch setting. The topology and switch settings determine how each of one of the inputs is connected to each of one of the outputs of the optical switch fabric. The switch settings are determined by a machine learning process which includes a model creation. The model can be made to adapt dynamically during optical switch fabric operation.

Dupuis, Nicolas↗

Development and experimental qualification of a calculation scheme for the evaluation of gamma heating in experimental reactors. Application to MARIA and Jules Horowitz (JHR) MTR Reactors

Precise computational determination of nuclear heating which consists predominantly of gamma heating (more than 80 %) is one of the challenges in material testing reactor exploitation. Due to sophisticated construction and conditions of experimental programs planned in JHR it became essential to use most accurate and precise gamma heating model. Before the JHR starts to operate, gamma heating evaluation methods need to be developed and qualified in other experimental reactor facilities. This is done inter alia using OSIRIS, MINERVE or EOLE research reactors in France. Furthermore, MARIA - Polish material testing reactor - has been chosen to contribute to the qualification of gamma heating calculation schemes/tools. This reactor has some characteristics close to those of JHR (beryllium usage, fuel element geometry). To evaluate gamma heating in JHR and MARIA reactors, both simulation tools and experimental program have been developed and performed. For gamma heating simulation, new calculation scheme and gamma heating model of MARIA have been carried out using TRIPOLI4 and APOLLO2 codes. Calculation outcome has been verified by comparison to experimental measurements in MARIA reactor. To have more precise calculation results, model of MARIA in TRIPOLI4 has been made using the whole geometry of the core. This has been done for the first time in the history of MARIA reactor and was complex due to cut cone shape of all its elements. Material composition of burnt fuel elements has been implemented from APOLLO2 calculations. An experiment for nuclear heating measurements and calculation verification has been done in September 2014. This involved neutron, photon and nuclear heating measurements at selected locations in MARIA reactor using in particular Rh SPND, Ag SPND, Ionization Chamber (all three from CEA), KAROLINA calorimeter (NCBJ) and Gamma Thermometer (CEA/SCK CEN). Measurements were done in forty points using four channels. Maximal nuclear heating evaluated from measurements is of the order of 2.5 W/g at half of the possible MARIA power - 15 MW. The approach and the detailed program for experimental verification of calculations will be presented. The following points will be discussed: - Development of a gamma heating model of MARIA reactor with TRIPOLI 4 (coupled neutron-photon mode) and APOLLO2 model taking into account the key parameters like: configuration of the core, experimental loading, control rod location, reactor power, fuel depletion); - Design of specific measurement tools for MARIA experiments including for instance a new single-cell calorimeter called KAROLINA calorimeter; - MARIA experimental program description and a preliminary analysis of results; - Comparison of calculations for JHR and MARIA cores with experimental verification analysis, calculation behavior and n-γ 'environments'. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

R and DE Robotic Sensor Intern Team: Sensor Suite Mock Up Testing

Assess sensor suite performance: - Mounted on crawler typical to what would be used in tunnel; - In test bed simulating the tunnel environment. The SuperDroid fiber tethered LT-F crawler is a general-purpose surveillance robot that our team has refurbished as a testing platform for the sensor suite. This crawler was selected because its dimensions are similar to the actual crawler that will be deployed in the field. Crawler preparation included: - Communicating with vendor to resolve software and platform issues; - Configuring a laptop with the crawler control software; - Reconfiguration of communication protocol between computer and crawler; - Resolution of control board checksum errors; - Installation of a mounting fixture on the base; - In progress: addition of lighting needed for total darkness. A solution for hosting the selected sensors onto a single unit that could function standalone or be mounted on the crawler was needed. Sensor mount requirements included: - Host Lidar, panospheric cameras and IMU sensors; - Cable management for rotating Lidar; - House on-board crawler computer; - Method for affixing to crawler; - Robust and vibration proof. The Lidar sensor required a sturdy mount that ensured the axis of rotation be centered with the LiDAR's desired laser path and included a slender profile in order to not block the scanning FOV. The mounting plate holds two 180-degree cameras on either side and the servo on the center. The servo mount is located so the axis of rotation is in the center of the plate. The mount features a set of guides that hold the wires and ensure they wrap around the spool area properly. The sensor box design features thick walls for added strength, holes for mounting the sensor suite to the crawler, notches on the bottom for the different components and holes for cable routing and management. The sensor mounts were designed using CREO and printed in the R and DE Additive Manufacturing Lab. To test the performance of the sensor suite for our application it was desired to design and build a test bed simulating the H-Canyon tunnel environment. Requirements included: - Dimensions similar to the tunnel; - Wall surfaces simulating the eroded tunnel walls; - Complete darkness; - Even and uneven crawler path; - Ability to change the tunnel width to simulate erosion. The HCAEX tunnel changes in height and includes several bends ranging from approximately 30 to 80 degrees, for that reason a test bed capable of easily being changed was needed. The final design includes two sections that can be connected to provide a 16' tunnel or placed at an angle to create a tunnel bend. The test bed features caster wheels for easy movement and has a sliding inner wall that enables tunnel width to be controlled. In order to simulate the tunnel walls without adding a lot of weight to the test bed, sheets of faux stone are to be used on the inner walls. To create a completely dark tunnel, 100% black-out film will be draped over the tunnel structure. Carpet remnants in the lab will enable folds to be introduced in the floor to generate uneven surface data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Depletion Analysis of Additively Manufactured Control Elements in HFIR

The High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory is a flux-trap type research reactor which provides one of the highest steady-state neutron sources in the world. HFIR neutrons are used for a range of research applications, including scattering experiments, materials irradiation, and isotope production. The HFIR core operates at 85 MW and is light water cooled and moderated. The core consists of several concentric cylindrical regions, as depicted in Fig. 1. At the center of the core is the flux trap, where the thermal flux reaches a maximum on the order of 10{sup 15} neutrons/cm{sup 2}-s. Immediately surrounding the flux trap are two annular fuel elements, an inner fuel element and an outer fuel element, each loaded with hundreds of thin fuel plates curved into an involute shape. Surrounding the outer fuel element are two thin control elements (CEs), an inner CE (ICE) and an outer CE (OCE). The CEs are axially zoned into three regions according to absorption strength: the white regions contain only structural aluminum and do not significantly contribute to absorption; the gray regions contain tantalum (Ta) as the primary absorber with a concentration of 30% by volume; and the black regions contain europium in the form of Eu{sub 2}O{sub 3} with a concentration of 33% by volume. A thick beryllium reflector is the final core component surrounding the CEs. A particular challenge to efficient maintenance and continued operation of HFIR is fabrication of the CEs, the current methods for which are tedious, outdated, and expensive. In an effort to improve the operational economics of HFIR and to demonstrate the application of advanced manufacturing techniques to the production of nuclear reactor components, the ultrasonic additive manufacturing (UAM) process is being investigated for fabrication of the HFIR CEs. This application of UAM involves directly embedding small cylindrical compacts (∼5.6 mm diameter, ∼1.7 mm thick) containing 60% neutron poison by volume into an aluminum matrix, using energy from ultrasonic vibrations to bond the compacts to the aluminum. The CEs contain discrete regions of absorbing material, in contrast to the standard design with homogeneously distributed absorbers. This novel design necessitates an investigation into how the HFIR core neutronic behavior differs from the case with homogeneous CEs so as to ascertain the feasibility of using additively manufactured CEs in HFIR. From an operations perspective, it is desirable for the discrete CEs to match the performance of the homogeneous CEs as closely as possible so as to avoid reconsideration of established safety margins. Earlier analyses of HFIR under beginning of cycle (BOC) conditions have indicated that although absorption properties on a local scale differ significantly between CE designs, the macroscopic behavior (neutron multiplication and flux and power distributions) of the HFIR core is not significantly altered. This study now addresses CE performance throughout depletion of the HFIR core during a reactor cycle. These analyses help to construct a more complete picture of the feasibility of employing additively manufactured CEs in HFIR and will reveal any adjustments which must be made to the design in order to maintain acceptable performance. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IOTA Pre-Bake Test Development

The IOTA (Integrable Optics Test Accelerator) Bakeout project is intended to improve the quality of the vacuum within the IOTA ring. Impurities consisting of hydrogen and oxygen that build within the beampipe are reduced through applying heat to the beampipe’s exterior. Two versions of the Bakeout project exist, one as a smaller scale test setup, and one five times larger located within the IOTA ring. During my internship, I worked together with a team to bring this project from an effectively dormant state to ready for testing, working together to create full documentation of the PLC (Programmable Logic Controller) programs, making multiple new hardware configurations of this test possible, as well as an additional safety system.

Seagrave, Kayla [DuPage Coll.; Fermilab]↗

Deterministic Modeling of the High Temperature Test Reactor

Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine INL’s current prismatic reactor deterministic analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 column thin annular core, and the fully loaded core critical condition with 30 columns. Special emphasis is devoted to the annular core modeling, which shares more characteristics with the NGNP base design. The DRAGON code is used in this study because it offers significant ease and versatility in modeling prismatic designs. Despite some geometric limitations, the code performs quite well compared to other lattice physics codes. DRAGON can generate transport solutions via collision probability (CP), method of characteristics (MOC), and discrete ordinates (Sn). A fine group cross section library based on the SHEM 281 energy structure is used in the DRAGON calculations. HEXPEDITE is the hexagonal z full core solver used in this study and is based on the Green’s Function solution of the transverse integrated equations. In addition, two Monte Carlo (MC) based codes, MCNP5 and PSG2/SERPENT, provide benchmarking capability for the DRAGON and the nodal diffusion solver codes. The results from this study show a consistent bias of 2–3% for the core multiplication factor. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Beam Voltage, 10 MW, L-Band Cluster Klystron

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

43 PARTICLE ACCELERATORS↗

Converter with phase-offset switching

Various examples are directed to electrical converters and systems for operating the same. An electrical converter may comprise a first converter module configured to receive a first direct current (DC) input and provide a first output. The first converter module may comprise a first switch modulated according to a first switch control signal. A second converter module may be configured to receive a second DC input and provide a second output. The second converter module may be connected in series with the first converter module. The second converter module may comprise a second switch modulated according to a second switch control signal. A phase of the first switch control signal may be offset from a phase of the second switch control signal by a first phase offset.

Bhowmik, Shibashis↗

GMS Station SOH Monitoring Configuration Guide (V.1.2)

The GMS Station State-of-Health (SOH) monitoring capability provides the system controller the ability to view current SOH values and calculated statistics for stations and channels, view trend plots of SOH values, be notified when station SOH status changes, and acknowledge or quiet notifications while the station issues are being investigated. The SOH monitoring capability includes components to acquire CD 1.1 protocol station data, extract SOH information from the raw data packets, process the raw SOH information for display, store the SOH information, and display the SOH information in an interactive display. All these components use system and processing configuration to provide the system controller mission-relevant information about station health. This document is a guide to setting the processing configuration for GMS SOH monitoring.

97 MATHEMATICS AND COMPUTING↗

Adaptive Control of Distributed Energy Resources for Distribution Grid Voltage Stability

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. Here we provide a derivation of the adaptive control approach and validate the algorithm in experiments on the IEEE 37 and 8500 node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deterministic Modeling of the High Temperature Test Reactor with DRAGON-HEXPEDITE

The Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine the INL’s current prismatic reactor analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 fuel column thin annular core, and the fully loaded core critical condition with 30 fuel columns. Special emphasis is devoted to physical phenomena and artifacts in HTTR that are similar to phenomena and artifacts in the NGNP base design. The DRAGON code is used in this study since it offers significant ease and versatility in modeling prismatic designs. DRAGON can generate transport solutions via Collision Probability (CP), Method of Characteristics (MOC) and Discrete Ordinates (Sn). A fine group cross-section library based on the SHEM 281 energy structure is used in the DRAGON calculations. The results from this study show reasonable agreement in the calculation of the core multiplication factor with the MC methods, but a consistent bias of 2-3% with the experimental values is obtained. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U 235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement partially stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗