Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline↗

Which Is the Optimal Biologically Effective Dose of Stereotactic Body Radiotherapy for Stage I Non-Small-Cell Lung Cancer? A Meta-Analysis

Purpose: To assess the relationship between biologically effective dose (BED) and efficacy of stereotactic body radiation therapy (SBRT) and to explore the optimal BED range for Stage I non-small-cell lung cancer (NSCLC). Methods and Materials: Eligible studies were identified on Medline, Embase, the Cochrane Library, and the proceedings of annual meetings through June 2010. According to the quartile of included studies, BED was divided into four dose groups: low (<83.2 Gy), medium (83.2-106 Gy), medium to high (106-146 Gy), high (>146 Gy). To obtain pooled estimates of overall survival (OS), cancer-specific survival (CSS), and local control rate (LCR), data were combined in a random effect model. Pooled estimates were corrected for the percentage of small tumors (<3 cm). Results: Thirty-four observational studies with a total of 2,587 patients were included in the meta-analysis. Corrected pooled estimates of 2- or 3-year OS in the medium BED (76.1%, 63.5%) or the medium to high BED (68.3%, 63.2%) groups were higher than in the low (62.3%, 51.9%) or high groups (55.9%, 49.5%), respectively (p {<=} 0.004). Corrected 3-year CSS in the medium (79.5%), medium to high (80.6%), and high groups (90.0%) were higher than in the low group (70.1%, p = 0.016, 0.018, 0.001, respectively). Conclusion: The OS for the medium or medium to high BED groups were higher than those for the low or high BED group for SBRT in Stage I NSCLC. The medium or medium to high BED (range, 83.2-146 Gy) for SBRT may currently be more beneficial and reasonable in Stage I NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CDF trigger final balance: Offline resolution at low level selections to fight against Tevatron increasing luminosity

The CDF detector at Tevatron collider is at present the most long-lasting high energy physics experiment. Since its first data taking in 1992 it has produced many results of primary importance, such as the discovery of top quark and, more recently, the observations of Bs oscillations and single-top production. None of them would have been possible without a fast and efficient trigger system. Based on a three level architecture, the CDF trigger takes decisions on simple calorimetric and tracking objects and assures both high efficiency on signal events and low dead time. It reduces the data flow rate from 2.53 MHz, the collision rate, to 150 Hz, the current limit on tape writing and is flexible enough to be easily adapted to the continuously growing instantaneous luminosity. In the last years the Tevatron instantaneous luminosity has rapidly increased and is now reaching 4 x 10{sup 32} cm{sup -2} s{sup -1}. The CDF trigger system has been widely upgraded to cope with increasing trigger rates. The upgrade result is online reconstruction of missing transverse energy, jets and tracks with a quality comparable to the offline one. Jet energy and direction can be precisely determined and tracks can be subjected to 3-D reconstruction with good resolution. These upgrades reduce high trigger rates to acceptable levels and have provided invaluable tools to increase the purity of the collected samples. They also represent a helpful experience for LHC experiments where background rates will be much more demanding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated control and optimization of laser-driven ion acceleration

The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimization of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by machine learning present a valuable opportunity for efficient source optimization. Here, an automated, HRR-compatible system produced high-fidelity parameter scans, revealing the influence of laser intensity on target pre-heating and proton generation. A closed-loop Bayesian optimization of maximum proton energy, through control of the laser wavefront and target position, produced proton beams with equivalent maximum energy to manually optimized laser pulses but using only 60% of the laser energy. This demonstration of automated optimization of laser-driven proton beams is a crucial step towards deeper physical insight and the construction of future radiation sources.

47 OTHER INSTRUMENTATION↗

Atomic Force Microscope Controlled Topographical Imaging and Proximal Probe Thermal Desorption/Ionization Mass Spectrometry Imaging

This paper reports on the development of a hybrid atmospheric pressure atomic force microscopy/mass spectrometry imaging system utilizing nano-thermal analysis probes for thermal desorption surface sampling with subsequent atmospheric pressure chemical ionization and mass analysis. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to correlate topographic images of a surface with atomic force microscopy and a mass spectral chemical image of the same surface, utilizing the same probe without moving the sample from the system, was demonstrated. Co-registered mass spectral chemical images and atomic force microscopy topographical images were obtained from inked patterns on paper as well as from a living bacterial colony on an agar gel. Spatial resolution of the topography images based on pixel size (0.2 m x 0.8 m) was better than the resolution of the mass spectral images (2.5 m x 2.0 m), which were limited by current mass spectral data acquisition rate and system detection levels.

Ovchinnikova, Olga S↗

Effect of Adsorbed Carboxylates on the Dissolution of Boehmite Nanoplates in Highly Alkaline Solutions

Understanding the dissolution of boehmite in highly alkaline solutions is important to the processing of the complex nuclear wastes stored at the Hanford (WA) and Savannah River (SC) sites. Here, we report the adsorption of model carboxylate anions on boehmite nanoplates in alkaline solutions and their effects on subsequent boehmite dissolution in 3 M NaOH at 80 °C. Although expectedly lower than at circumneutral pH, adsorption of oxalate at pH 13 at room temperature was significant and remained so through a linear decrease to 3 M NaOH conditions with no evidence for the appearance of new phases. Modeling of the adsorption data and rate were consistent with the formation of outer-sphere surface complexes. By using these conditions to preload the boehmite nanoplates with oxalate, and separately acetate, we measured and compared their dissolution behavior at 80 °C and observed a clear suppression of the dissolution rate for the case of adsorbed oxalate by 23% and for adsorbed acetate by 10% compared to pure solids. Ex situ scanning electron microscopy (SEM) and transmission electron microscopy (TEM) characterization revealed no detectable difference in the morphologic evolution of the dissolving boehmite materials. In conclusion, we nonetheless conclude that pre-adsorbed carboxylate anions, even as nominally weakly bound outer-sphere complexes, can persist on the surface through highly alkaline conditions, decreasing the density of dissolution-active sites and thereby adding an extrinsic control on the dissolution rate.

Adsorption kinetics↗

Rapid mapping of polarization switching through complete information acquisition

Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (~1 s) switching and fast (~10 kHz–1 MHz) detection waveforms. Here we develop an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures.

36 MATERIALS SCIENCE↗

Real-Time event reconstruction for Nuclear Physics Experiments using Artificial Intelligence

Charged track reconstruction is a critical task in nuclear physics experiments, enabling the identification and analysis of particles produced in high-energy collisions. Machine learning (ML) has emerged as a powerful tool for this purpose, addressing the challenges posed by complex detector geometries, high event multiplicities, and noisy data. Traditional methods rely on pattern recognition algorithms like the Kalman filter, but ML techniques, such as neural networks, graph neural networks (GNNs), and recurrent neural networks (RNNs), offer improved accuracy and scalability. By learning from simulated and real detector data, ML models can identify and classify tracks, predict trajectories, and handle ambiguities caused by overlapping or missing hits. Moreover, ML-based approaches can process data in near-real-time, enhancing the efficiency of experiments at large-scale facilities like the Large Hadron Collider (LHC) and Jefferson Lab (JLAB). As detector technologies and computational resources evolve, ML-driven charged track reconstruction continues to push the boundaries of precision and discovery in nuclear physics. In these proceedings, we highlight advancements in charged track identification leveraging Artificial Intelligence within the CLAS12 detector, achieving a notable enhancement in experimental statistics compared to traditional methods. Additionally, we showcase real-time event reconstruction capabilities, including the inference of charged particle properties, such as momentum, direction, and species identification, at speeds matching data acquisition rates. These innovations enable the extraction of physics observables directly from the experiment in real-time.

Gavalian, Gagik (ORCID:0000000267385457)↗

Effect of recording condition on the diffraction efficiency of magnetic hologram with magnetic garnet films

A holographic memory has been attracting attention as recording media with high recording density and high data transfer rate. We have studied the magnetic garnets as a rewritable and long life media for magnetic holography. However, since the signal intensity of reconstructed image was relatively low, the effects of recording conditions on the diffraction efficiency of magnetic hologram were investigated with experiments and the numerical simulation using COMSOL multi-physics. The diffraction efficiency tends to decrease as increasing the spatial frequency, and the use of short pulse laser with the pulse width of 50 ps was found to be effective to achieve high diffraction efficiency. This suggests that the formation of clear magnetic fringe similar to interference pattern can be obtained by the use of short pulse laser since undesirable heat diffusion during radiation does not occur. On the other hand, the diffraction efficiency increased as increasing the film thickness up to 3.1 μm but was saturated in the garnet film thicker than 3.1 μm in the case of spatial frequency of 1500 line pair/mm. The numerical simulation showed that the effective depth of magnetic fringe was limited about 1.8 μm irrespective of the garnet film thickness because the fringes were connected by thermal diffusion near the surface of the film, and the effective depth is limited due to this connection of the magnetic fringe. Avoiding this fringe connection, much higher diffraction efficiency will be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A widefield fluorescence microscope with a linear image sensor for image cytometry of biospecimens: Considerations for image quality optimization

Linear image sensors have been widely used in numerous research and industry applications to provide continuous imaging of moving objects. Here, we present a widefield fluorescence microscope with a linear image sensor used to image translating objects for image cytometry. First, a calibration curve was characterized for a custom microfluidic chamber over a span of volumetric pump rates. Image data were also acquired using 15 μm fluorescent polystyrene spheres on a slide with a motorized translation stage in order to match linear translation speed with line exposure periods to preserve the image aspect ratio. Aspect ratios were then calculated after imaging to ensure quality control of image data. Fluorescent beads were imaged in suspension flowing through the microfluidics chamber being pumped by a mechanical syringe pump at 16 μl min{sup −1} with a line exposure period of 150 μs. The line period was selected to acquire images of fluorescent beads with a 40 dB signal-to-background ratio. A motorized translation stage was then used to transport conventional glass slides of stained cellular biospecimens. Whole blood collected from healthy volunteers was stained with 0.02% (w/v) proflavine hemisulfate was imaged to highlight leukocyte morphology with a 1.56 mm × 1.28 mm field of view (1540 ms total acquisition time). Oral squamous cells were also collected from healthy volunteers and stained with 0.01% (w/v) proflavine hemisulfate to demonstrate quantifiable subcellular features and an average nuclear to cytoplasmic ratio of 0.03 (n = 75), with a resolution of 0.31 μm pixels{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EVOLUTION OF X-RAY SPECTRA AND LIGHT CURVES OF V1494 AQUILAE

We present six Chandra X-ray spectra and light curves obtained for the nova V1494 Aql (1999 No. 2) in outburst. The first three observations were taken with the Advanced CCD Imaging Spectrometer (ACIS-I) on days 134, 187, and 248 after outburst. The count rates were 1.00, 0.69, and 0.53 counts s{sup -1}, respectively. We found no significant periodicity in the ACIS light curves. The X-ray spectra show continuum emission and lines originating from N and O. We found acceptable spectral fits using isothermal APEC models with significantly increased elemental abundances of O and N for all observations. On day 248 after outburst a bright soft component appeared in addition to the fading emission lines. The Chandra observations on days 300, 304, and 727 were carried out with the High Resolution Camera/Low Energy Transmission Grating Spectrometer (LETGS). The spectra consist of continuum emission plus strong emission lines of O and N, implying a high abundance of these elements. On day 300, a flare occurred and periodic oscillations were detected in the light curves taken on days 300 and 304. This flare must have originated deep in the outflowing material since it was variable on short timescales. The spectra extracted immediately before and after the flare are remarkably similar, implying that the flare was an extremely isolated event. Our attempts to fit blackbody, cloudy, or APEC models to the LETGS spectra failed, owing to the difficulty in disentangling continuum and emission-line components. The spectrum extracted during the flare shows a significant increase in the strengths of many of the lines and the appearance of several previously undetected lines. In addition, some of the lines seen before and after the flare are not present during the flare. On day 727 only the count rate from the zeroth order could be derived, and the source was too faint for the extraction of a light curve or spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

SPITZER OBSERVATIONS OF COLD DUST GALAXIES

We combine new Spitzer Space Telescope observations in the mid-infrared and far-infrared (FIR) with SCUBA 850 {mu}m observations to improve the measurement of dust temperatures, masses, and luminosities for 11 galaxies of the SCUBA Local Universe Galaxy Survey. By fitting dust models we measure typical dust masses of 10{sup 7.9} M {sub sun} and dust luminosities of {approx}10{sup 10} L {sub sun}, for galaxies with modest star formation rates. The data presented in this paper combined with previous observations show that cold dust is present in all types of spiral galaxies and is a major contributor to their total luminosity. Because of the lower dust temperature of the SCUBA sources measured in this paper, they have flatter FIR {nu}F{sub {nu}}(160 {mu}m)/{nu}F{sub {nu}}(850 {mu}m) slopes than the larger Spitzer Infrared Nearby Galaxies Survey (SINGS), the sample that provides the best measurements of the dust properties of galaxies in the nearby universe. The new data presented here added to SINGS extend the parameter space that is well covered by local galaxies, providing a comprehensive set of templates that can be used to interpret the observations of nearby and distant galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

METHODS FOR ESTIMATING FLUXES AND ABSORPTIONS OF FAINT X-RAY SOURCES

X-ray sources with very few counts can be identified with low-noise X-ray detectors such as the Advanced CCD Imaging Spectrometer on board the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broadband X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high signal-to-noise spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of approx2000 faint sources in the Chandra observation of the rich young stellar cluster in the M 17 H II region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of nonlinear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

A MULTI-WAVELENGTH VIEW OF THE STAR FORMATION ACTIVITY AT z {approx} 3

We present a multi-wavelength, UV-to-radio analysis for a sample of massive (M{sub *} {approx} 10{sup 10} M{sub sun}) IRAC- and MIPS 24 {mu}m detected Lyman break galaxies (LBGs) with spectroscopic redshifts z {approx} 3 in the GOODS-North field. For LBGs without individual 24 {mu}m detections, we employ stacking techniques at 24 {mu}m, 1.1 mm, and 1.4 GHz to construct the average UV-to-radio spectral energy distribution and find it to be consistent with that of a luminous infrared galaxy with L{sub IR} = 4.5{sup +1.1}{sub -2.3} x 10{sup 11} L{sub sun} and a specific star formation rate of 4.3 Gyr{sup -1} that corresponds to a mass doubling time {approx}230 Myr. On the other hand, when considering the 24 {mu}m detected LBGs we find among them galaxies with L{sub IR}>10{sup 12} L{sub sun}, indicating that the space density of z {approx} 3 UV-selected ultra-luminous infrared galaxies (ULIRGs) is {approx}(1.5 {+-} 0.5) x 10{sup -5} Mpc{sup -3}. We compare measurements of star formation rates from data at different wavelengths and find that there is tight correlation (Kendall's {tau}>99.7%) and excellent agreement between the values derived from dust-corrected UV, mid-IR, millimeter, and radio data for the whole range of L{sub IR} up to L{sub IR} {approx} 10{sup 13} L{sub sun}. This range is greater than that for which the correlation is known to hold at z {approx} 2, possibly due to the lack of significant contribution from polycyclic aromatic hydrocarbons to the 24 {mu}m flux at z {approx} 3. The fact that this agreement is observed for galaxies with L{sub IR}>10{sup 12} L{sub sun} suggests that star formation in UV-selected ULIRGs, as well as the bulk of star formation activity at this redshift, is not embedded in optically thick regions as seen in local ULIRGs and submillimeter-selected galaxies at z = 2.

79 ASTRONOMY AND ASTROPHYSICS↗