Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Characterizations of silver alloys used in modern Mexican coins

This paper presents a complete methodology for the characterization of silver alloys used in modern coin production. Mexican coins with a nominal silver concentration from 10% to 99.99% were used in this study. Calibrated Glow Discharge Optical Emission Spectrometers were used to determine the chemical composition of the alloys as a function of the depth, while inductively coupled plasma was used to determine the total element composition in bulk. Scanning Electron Microscope was used to study the phase distributions in the different silver coins. According to Glow Discharge Optical Emission Spectrometers and inductively coupled plasma, the silver content found in the studied samples was consistently greater than that of the nominal silver content reported by the Mexican mint. This may lead to a review of the new methods of analysis used nowadays in contemporary coin minting. This result is very important because silver is increasing in value as metal and, considering the volume of production of silver coins, this may increase further as a consequence of a growing popular confidence in silver currency. In the case of silver studies, an advantage of the absence of silver detector in the Glow Discharge Optical Emission Spectrometers system is that it allows for the recalibration to have a better range of detection of other metals present in the alloys. A calibration curve using the copper content obtained by inductively coupled plasma (bulk) and Glow Discharge Optical Emission Spectrometers (depth profile) was performed. The relevance of control in modern silver coin minting was clarified, especially in minimizing the discrepancy between the nominal and the core fineness. The physical and chemical properties of the alloys studied are defined, revealing important variations in silver and copper contents. A new methodology and metrology for the control of coinage are suggested.

36 MATERIALS SCIENCE↗

Rigid versus Flexible Ligands on Carbon Nanotubes for the Enhanced Sensitivity of Cobalt Ions

Carbon nanotubes have shown great promise in the fabrication of ultra-compact and highly sensitive chemical and biological sensors. Additional chemical functionalization schemes can controllably improve selectivity of the carbon nanotube-based sensors; however the exact transduction mechanism is still under debate. In this article we detail the synthesis and selective response of single-walled carbon nanotubes (SWNTs) functionalized with polyazomethine (PAM) polymer towards the application of a specific trace metal ion detector. The response of the polymer system was compared to shape persistent macrocycle (MAC) comprised of identical ion coordination ligands. While ion detection with rigid MAC/SWNT chemiresistor was comparable to bare SWNT, flexible PAM offers significant SWNT signal amplification, allowing for picomolar detection of Co{sup 2+} ions with both selectivity and a fast response. We hypothesized that rearrangement of the flexible PAM on the SWNT network is a sensing mechanism which allows for ultrasensitive detection of metal ions. The electron transfer and polymer rearrangement on the SWNT was studied by a combination of optical spectroscopy and electrical measurements - ultimately allowing for a better understanding of fundamental mechanisms that prompt device response.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The DUNE-DAQ Application Framework

The deep underground neutrino experiment (DUNE) is a next-generation neutrino experiment that will probe the properties of these elusive particles with unparalleled precision. It will also act as an observatory for neutrino bursts caused by nearby supernovae, in the event that one occurs, while the experiment is in operation. Given these goals, the DUNE trigger and DAQ system must be able to maintain extremely high uptime and provide a path for full readout of the detectors for very long times (up to 100 s). To achieve these ends, we have designed the DUNE DAQ system around a flexible “application framework,” which provides a modular interface for specific tasks while handling the interconnections between them. The application framework collects modules into applications, which can then be interacted with as units by the control, configuration, and monitoring systems. One of the key features of the framework is its communication abstraction layer, which allows for modules to interact with both internal queues and external network connections with a single transport-agnostic interface. We will report on the architecture and features of the framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront control of the Large Optics Test and Integration Site (LOTIS) 6.5m Collimator

The LOTIS Collimator provides scene projection within a 6.5m diameter collimated beam used for optical testing research in air and vacuum. Diffraction-limited performance (0.4 to 5{mu}m wavelength) requires active wavefront control of the alignment and primary mirror shape. A hexapod corrects secondary mirror alignment using measurements from collimated sources directed into the system with nine scanning pentaprisms. The primary mirror shape is controlled with 104 adjustable force actuators based on figure measurements from a center-of-curvature test. A variation of the Hartmann test measures slopes by monitoring the reflections from 36 small mirrors bonded to the optical surface of the primary mirror. The Hartmann source and detector are located at the f/15 Cassegrain focus. Initial operation has demonstrated a closed-loop 110nmrms wavefront error in ambient air over the 6.5mcollimated beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The robot's eyes - Stereo vision system for automated scene analysis

Attention is given to the robot stereo vision system which maintains the image produced by solid-state detector television cameras in a dynamic random access memory called RAPID. The imaging hardware consists of sensors (two solid-state image arrays using a charge injection technique), a video-rate analog-to-digital converter, the RAPID memory, and various types of computer-controlled displays, and preprocessing equipment (for reflexive actions, processing aids, and object detection). The software is aimed at locating objects and transversibility. An object-tracking algorithm is discussed and it is noted that tracking speed is in the 50-75 pixels/s range.

Williams, D. S.↗

Space processing of electronic materials

The bulk growth of solid solution alloys of mercury telluride and cadmium telluride is discussed. These alloys are usually described by the formula Hg1-xCdxTe, and are useful for the construction of infrared detectors. The electronic energy band gap can be controlled between zero and 1.6 electron volts by adjusting the composition x. The most useful materials are at x approximately 20%, suitable for detection wavelengths of about 10 micrometers. The problems of growing large crystals are rooted in the wide phase diagram of the HgTe-CdTe pseudobinary system which leads to exaggerate segregation in freezing, constitutional supercooling, and other difficulties, and in the high vapor pressure of mercury at the growth temperatures, which leads to loss of stoichiometry and to the necessity of working in strong, pressure resistant sealed containers.

Holland, L. R.↗

Thermal modeling of the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically cooled telescope in the one-meter aperture class designed for sensing in the infrared from 2-200 microns. This facility is currently planned for multiple missions onboard the Space Shuttle with varying instrument complements. All components of the SIRTF within the field of view of the optics are cryogenically cooled. The baseline primary coolant is supercritical helium which is stored in an external tank and routed through the telescope-cooling the instruments, the optical components and the baffles. For detector cooling below 6 K, small reservoirs of superfluid helium (HeII) are provided. The SIRTF was thermally modeled on the SINDA computer program both for steady state and transient solutions. The analysis shows that the baseline configuration has a large capacity for growth in cryogen requirements. A proportional controller model was developed for transient operations. The control system maintained the optics within all prescribed temperature limits except for certain combinations of transients involving a large step change in the power dissipation in the secondary mirror assembly and/or when the primary mirror was assumed to be constructed of quartz. The baseline SIRTF will perform the mission for which it was designed.

Gier, H. L.↗

Analysis of materials from MSFC LDEF experiments

In preparation for the arrival of the Long Duration Exposure Facility (LDEF) samples, a material testing and handling approach was developed for the evaluation of the materials. A configured lab was made ready for the de-integration of the LDEF experiments. The lab was prepared to clean room specifications and arranged with the appropriate clean benches, tables, lab benches, clean room tools, particulate counter, and calibrated and characterized analytical instrumentation. Clean room procedures were followed. Clean room attire and shoe cleaning equipment were selected and installed for those entering. Upon arrival of the shipping crates they were taken to the lab, logged in, and opened for examination. The sample trays were then opened for inspection and test measurements. The control sample measurements were made prior to placement into handling and transport containers for the flight sample measurements and analysis. Both LDEF flight samples and LDEF type materials were analyzed and tested for future flight candidate material evaluation. Both existing and newly purchased equipment was used for the testing and evaluation. Existing Space Simulation Systems had to be upgraded to incorporate revised test objectives and approaches. Fixtures such as special configured sample holders, water, power and LN2 feed-throughs, temperature measurement and control, front surface mirrors for reflectance and deposition, and UV grade windows had to be designed, fabricated, and installed into systems to achieve the revised requirements. New equipment purchased for LDEF analysis was incorporated into and/or used with existing components and systems. A partial list of this equipment includes a portable monochromator, enhanced UV System, portable helium leak detector for porosity and leak measurements, new turbo pumping system, vacuum coaster assembly, cryopumps, and analytical and data acquisition equipment. A list of materials tested, equipment designed, fabricated and installed, systems used, and analytical research accomplished on both LDEF flight samples and on similar materials which were lab tested for a comparative analysis to the LDEF flight samples is presented.

Johnson, R. Barry↗

Directional spectral emissivity measurement system

Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

Halyo, Nesim↗

Design for Minimum Casualty Area – The IXPE Case

The Imaging X-Ray Polarimetry Explorer (IXPE) is a new international space observatory in NASA’s Small Explorer program, designed in a collaboration between the Italian Space Agency and NASA’s Marshall Space Flight Center, and built by Ball Aerospace. IXPE has an expected launch in November 2021, to a 600-km altitude equatorial orbit. IXPE is an astrophysics mission using three telescope assemblies to measure the polarization of cosmic X-rays. Each assembly is composed of a mirror module assembly (MMA) with 24 nested nickel-cobalt cylindrical shells and a unique, polarization-sensitive, gas pixel detector (GPD) within the detector unit (DU). As a NASA mission, IXPE must adhere to the orbital debris mitigation requirements specified in NASA Standard 8719.14 [1]; in the present work, we will only discuss reentry human casualty risk. As initially designed, the IXPE observatory exceeded NASA’s casualty risk threshold. IXPE does not include a propulsion system to perform a controlled reentry at the end of mission to mitigate the ground casualty risk. To reduce the risk from the uncontrolled reentry of this observatory, the IXPE design team worked with the NASA Orbital Debris Program Office to reduce the debris casualty area through design-for-demise and containment methods. The flight design of IXPE is now compliant with the ground casualty risk requirement at a casualty probability of 1:13,100 compared to a casualty requirement of better than 1:10,000.

C Ostrom↗

Advanced Bent Crystal Collimation Studies at the Tevatron (T-980)

The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics, electronics, control and software has been manufactured, tested and installed in the E0 crystal region. The purpose of the pixel telescope is to measure and image channeled (CH), volume-reflected (VR) and multiple volume-reflected (MVR) beam profiles produced by bent crystals. Third, an ORIGIN-based system has been developed for thorough analysis of experimental and simulation data. Results of analysis are presented for different types of crystals used from 2005 to present for channeling and volume reflection including pioneering tests of two-plane crystal collimation at the collider, all in comparison with detailed simulations.

43 PARTICLE ACCELERATORS↗

Performance Characteristics Of An Intensity Modulated Advanced X-Ray Source (IMAXS) For Homeland Security Applications

X-ray cargo inspection systems for the detection and verification of threats and contraband must address stringent, competitive performance requirements. High x-ray intensity is needed to penetrate dense cargo, while low intensity is desirable to minimize the radiation footprint, i.e. the size of the controlled area, required shielding and the dose to personnel. In a collaborative effort between HESCO/PTSE Inc., XScell Corp., Stangenes Industries, Inc. and Rapiscan Laboratories, Inc., an Intensity Modulated Advanced X-ray Source (IMAXS) was designed and produced. Cargo inspection systems utilizing such a source have been projected to achieve up to 2 inches steel-equivalent greater penetration capability, while on average producing the same or smaller radiation footprint as present fixed-intensity sources. Alternatively, the design can be used to obtain the same penetration capability as with conventional sources, but reducing the radiation footprint by about a factor of three. The key idea is to anticipate the needed intensity for each x-ray pulse by evaluating signal strength in the cargo inspection system detector array for the previous pulse. The IMAXS is therefore capable of changing intensity from one pulse to the next by an electronic signal provided by electronics inside the cargo inspection system detector array, which determine the required source intensity for the next pulse. We report on the completion of a 9 MV S-band (2998 MHz) IMAXS source and comment on its performance.

07 ISOTOPE AND RADIATION SOURCES↗

Quantum Instrumentation and Control Kit (QICK) for Quantum Networks

We report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC FPGA technology to drive an entangled photon pair source and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon Gamma Detector Project Support

This project provided funding of $48,500 for part of one year to support the development of compressed xenon spectrometers at BNL. This report describes upgrades that were made to the existing detector system electronics during that period, as well as subsequent testing with check sources and Special Nuclear Materials. Previous testing of the equipment extended only up to the energy of 1.3 MeV, and did not include a spectrum of Pu-239. The new electronics allowed one-button activation of the high voltage ramp that was previously controlled by manual adjustments. Mechanical relays of the charging circuit were replaced by a tera-ohm resistor chain and an optical switch. The preamplifier and shaping amplifier were replaced by more modern custom designs. We found that the xenon purity had not been degraded since the chamber was filled 10 years earlier. The resulting spectra showed significantly better resolution than sodium iodide spectra, and could be analyzed quite effectively by methods using peak area templates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risks, designs, and research for fire safety in spacecraft

Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.

Friedman, Robert↗

Optical detector having a plurality of matrix layers with cobalt disilicide particles embedded therein

Silicon and metal are coevaporated onto a silicon substrate in a molecular beam epitaxy system with a larger than stoichiometric amount of silicon so as to epitaxially grow particles of metal silicide embedded in a matrix of single crystal epitaxially grown silicon. The particles interact with incident photons by resonant optical absorption at the surface plasmon resonance frequency. Controlling the substrate temperature and deposition rate and time allows the aspect ratio of the particles to be tailored to desired wavelength photons and polarizations. The plasmon energy may decay as excited charge carriers of phonons, either of which can be monitored to indicate the amount of incident radiation at the selected frequency and polarization.

Fathauer, Robert W.↗

Optoelectronic Infrastructure for Radio Frequency and Optical Phased Arrays

Optoelectronic integrated circuits offer radiation-hardened solutions for satellite systems in addition to improved size, weight, power, and bandwidth characteristics. ODIS, Inc., has developed optoelectronic integrated circuit technology for sensing and data transfer in phased arrays. The technology applies integrated components (lasers, amplifiers, modulators, detectors, and optical waveguide switches) to a radio frequency (RF) array with true time delay for beamsteering. Optical beamsteering is achieved by controlling the current in a two-dimensional (2D) array. In this project, ODIS integrated key components to produce common RF-optical aperture operation.

Cai, Jianhong↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗