Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Estimate of the single diffractive heavy quark production in heavy ion collisions at the CERN LHC

The single diffractive cross section for heavy quarks production is calculated at next-to-leading order (for nucleus-nucleus collisions. Such processes are expected to occur at the LHC, where the nuclei involved are lead at {radical}(s)=5.5 TeV and calcium at {radical}(s)=6.3 TeV. We start using the hard diffractive factorization formalism, taking into account a recent experimental parametrization for the Pomeron structure function (DPDF). Absorptive corrections are accounted for by the multiple Pomeron contributions considering a gap survival probability, where its theoretical uncertainty for nuclear collisions is discussed. We estimate the diffractive ratios for the single diffraction process in nuclear coherent/incoherent collisions at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unitarized model of inclusive and diffractive DIS with Q{sup 2} evolution

We discuss the interplay of low-x physics and QCD scaling violations by extending the unified approach describing inclusive structure functions and diffractive production in {gamma}*p interactions proposed in previous papers to large values of Q{sup 2}. We describe the procedure of extracting, from the nonperturbative model, initial conditions for the QCD evolution that respect unitarity. Assuming Regge factorization of the diffractive structure function, a similar procedure is proposed for the calculation of hard diffraction. The results are in good agreement with experimental data on the proton structure function F{sub 2} and the most recent data on the reduced diffractive cross section, x{sub P{sigma}r}{sup D(3)}. Predictions for both F{sub 2} and F{sub L} are presented in a wide kinematical range and compared to calculations within high-energy QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recovering magnetization distributions from their noisy diffraction data

We study, using simulated experiments inspired by thin-film magnetic domain patterns, the feasibility of phase retrieval in x-ray diffractive imaging in the presence of intrinsic charge scattering given only photon-shot-noise limited diffraction data. We detail a reconstruction algorithm to recover the sample's magnetization distribution under such conditions and compare its performance with that of Fourier transform holography. Concerning the design of future experiments, we also chart out the reconstruction limits of diffractive imaging when photon-shot-noise and the intensity of charge scattering noise are independently varied. This work is directly relevant to the time-resolved imaging of magnetic dynamics using coherent and ultrafast radiation from x-ray free-electron lasers and also to broader classes of diffractive imaging experiments which suffer noisy data, missing data, or both.

36 MATERIALS SCIENCE↗

Suppression of Decoherence in Fast-Atom Diffraction at Surfaces

Scattering of fast neutral atoms with keV kinetic energies at alkali-halide surfaces under grazing angles displays intriguing diffraction patterns. The surprisingly strong persistence of quantum coherence despite the impulsive interaction with an environment at solid state density and elevated temperatures raises fundamental questions such as to the suppression of decoherence and of the quantum-to-classical crossover. We present an ab initio simulation of the quantum diffraction of fast helium beams at a LiF (100) surface in the <110> direction and compare with recent experimental diffraction data. From the quantitative reconstruction of diffraction images the vertical LiF-surface reconstruction, or buckling, can be determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validating classical line profile analyses using microbeam diffraction from individual dislocation cell walls and cell interiors

Dislocation structures in deformed metals produce broad asymmetric diffraction line profiles. During analysis, these profiles are generally separated into two nearly symmetric subprofiles corresponding to diffraction by dislocation cell walls and cell interiors. These subprofiles are then interpreted using complex models of dislocation-based line broadening. Until now, it has not been possible to test the many assumptions that are made in such an analysis. Here, depth-resolved microbeam diffraction was used to measure diffraction line profiles from numerous individual dislocation cell walls and cell interiors in a heavily deformed Cu single crystal. Summing these profiles directly constructed the cell-interior and cell-wall subprofiles that have been approximated in the line profile analysis literature for the past 30 years. Direct comparison between the reconstructed subprofiles and the macroscopic asymmetric line profile from the same sample allows the first direct tests of many of the assumptions that have been used for interpreting these X-ray measurements.

36 MATERIALS SCIENCE↗

Cyclic olefin homopolymer-based microfluidics for protein crystallization and in situ X-ray diffraction

A cyclic olefin homopolymer-based microfluidics system has been established for protein crystallization and in situ X-ray diffraction. Microfluidics is a promising technology for the rapid identification of protein crystallization conditions. However, most of the existing systems utilize silicone elastomers as the chip material which, despite its many benefits, is highly permeable to water vapour. This limits the time available for protein crystallization to less than a week. Here, the use of a cyclic olefin homopolymer-based microfluidics system for protein crystallization and in situ X-ray diffraction is described. Liquid handling in this system is performed in 2 mm thin transparent cards which contain 500 chambers, each with a volume of 320 nl. Microbatch, vapour-diffusion and free-interface diffusion protocols for protein crystallization were implemented and crystals were obtained of a number of proteins, including chicken lysozyme, bovine trypsin, a human p53 protein containing both the DNA-binding and oligomerization domains bound to DNA and a functionally important domain of Arabidopsis Morpheus’ molecule 1 (MOM1). The latter two polypeptides have not been crystallized previously. For X-ray diffraction analysis, either the cards were opened to allow mounting of the crystals on loops or the crystals were exposed to X-rays in situ. For lysozyme, an entire X-ray diffraction data set at 1.5 Å resolution was collected without removing the crystal from the card. Thus, cyclic olefin homopolymer-based microfluidics systems have the potential to further automate protein crystallization and structural genomics efforts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-crystal Anomalous Diffraction for Low-resolution Macromolecular Phasing

Multiwavelength anomalous diffraction (MAD) and single-wavelength anomalous diffraction (SAD) are the two most commonly used methods for de novo determination of macromolecular structures. Both methods rely on the accurate extraction of anomalous signals; however, because of factors such as poor intrinsic order, radiation damage, inadequate anomalous scatterers, poor diffraction quality and other noise-causing factors, the anomalous signal from a single crystal is not always good enough for structure solution. In this study, procedures for extracting more accurate anomalous signals by merging data from multiple crystals are devised and tested. SAD phasing tests were made with a relatively large (1456 ordered residues) poorly diffracting (d{sub min} = 3.5 {angstrom}) selenomethionyl protein (20 Se). It is quantified that the anomalous signal, success in substructure determination and accuracy of phases and electron-density maps all improve with an increase in the number of crystals used in merging. Structure solutions are possible when no single crystal can support structural analysis. It is proposed that such multi-crystal strategies may be broadly useful when only weak anomalous signals are available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Processing incommensurately modulated protein diffraction data with Eval15

Data processing of an incommensurately modulated profilin–actin crystal is described. Recent challenges in biological X-ray crystallography include the processing of modulated diffraction data. A modulated crystal has lost its three-dimensional translational symmetry but retains long-range order that can be restored by refining a periodic modulation function. The presence of a crystal modulation is indicated by an X-ray diffraction pattern with periodic main reflections flanked by off-lattice satellite reflections. While the periodic main reflections can easily be indexed using three reciprocal-lattice vectors a*, b*, c*, the satellite reflections have a non-integral relationship to the main lattice and require a q vector for indexing. While methods for the processing of diffraction intensities from modulated small-molecule crystals are well developed, they have not been applied in protein crystallography. A recipe is presented here for processing incommensurately modulated data from a macromolecular crystal using the Eval program suite. The diffraction data are from an incommensurately modulated crystal of profilin–actin with single-order satellites parallel to b*. The steps taken in this report can be used as a guide for protein crystallographers when encountering crystal modulations. To our knowledge, this is the first report of the processing of data from an incommensurately modulated macromolecular crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sound velocities of compressed Fe{sup 3}c from simultaneous synchrotron x-ray diffraction and nuclear resonant scattering measurements.

The applications of nuclear resonant scattering in laser-heated diamond anvil cells have provided an important probe for the magnetic and vibrational properties of {sup 57}Fe-bearing materials under high pressure and high temperature. Synchrotron X-ray diffraction is one of the most powerful tools for studying phase stability and equation of state over a wide range of pressure and temperature conditions. Recently an experimental capability has been developed for simultaneous nuclear resonant scattering and X-ray diffraction measurements using synchrotron radiation. Here the application of this method to determine the sound velocities of compressed Fe{sub 3}C is shown. The X-ray diffraction measurements allow detection of microscale impurities, phase transitions and chemical reactions upon compression or heating. They also provide information on sample pressure, grain size distribution and unit cell volume. By combining the Debye velocity extracted from the nuclear resonant inelastic X-ray scattering measurements and the structure, density and elasticity data from the X-ray diffraction measurements simultaneously obtained, more accurate sound velocity data can be derived. Our results on few-crystal and powder samples indicate strong anisotropy in the sound velocities of Fe{sub 3}C under ambient conditions.

43 PARTICLE ACCELERATORS↗

Diffraction pattern simulation of cellulose fibrils using distributed and quantized pair distances

Intensity simulation of X-ray scattering from large twisted cellulose molecular fibrils is important in understanding the impact of chemical or physical treatments on structural properties such as twisting or coiling. This paper describes a highly efficient method for the simulation of X-ray diffraction patterns from complex fibrils using atom-type-specific pair-distance quantization. Pair distances are sorted into arrays which are labelled by atom type. Histograms of pair distances in each array are computed and binned and the resulting population distributions are used to represent the whole pair-distance data set. These quantized pair-distance arrays are used with a modified and vectorized Debye formula to simulate diffraction patterns. This approach utilizes fewer pair distances in each iteration, and atomic scattering factors are moved outside the iteration since the arrays are labelled by atom type. As a result, this algorithm significantly reduces the computation time while maintaining the accuracy of diffraction pattern simulation, making possible the simulation of diffraction patterns from large twisted fibrils in a relatively short period of time, as is required for model testing and refinement.

09 BIOMASS FUELS↗

New developments including X-ray standing waves in the dynamical Bragg diffraction program of X-ray Server

X-ray Server (https://x-server.gmca.aps.anl.gov) is a collection of programs for online modelling of X-ray diffraction and scattering. Additionally, the dynamical diffraction program is the second most popular Server program, contributing 34% of total Server usage. It models dynamical X-ray diffraction from strained crystals and multilayers for any Bragg-case geometry including grazing incidence and exit. This paper reports on a revision of equations used by the program, which yields ten times faster calculations in most use cases, on implementing calculations of X-ray standing waves and on adding new options for modelling diffraction from monolayers.

36 MATERIALS SCIENCE↗

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

47 OTHER INSTRUMENTATION↗

Identification of inversion domains in KTiOPO{sub 4}via resonant X-ray diffraction

The identification and high-resolution mapping of the absolute crystallographic structure in multi-domain ferroelectric KTiOPO{sub 4} is achieved through a novel synchrotron X-ray diffraction method. On a single Bragg reflection, the intensity ratio in resonant diffraction below and above the Ti absorption K edge demonstrates a domain contrast up to a factor of ∼270, thus implementing a non-contact, non-destructive imaging technique with micrometre spatial resolution, applicable to samples of arbitrarily large dimensions. A novel method is presented for the identification of the absolute crystallographic structure in multi-domain polar materials such as ferroelectric KTiOPO{sub 4}. Resonant (or ‘anomalous’) X-ray diffraction spectra collected across the absorption K edge of Ti (4.966 keV) on a single Bragg reflection demonstrate a huge intensity ratio above and below the edge, providing a polar domain contrast of ∼270. This allows one to map the spatial domain distribution in a periodically inverted sample, with a resolution of ∼1 µm achieved with a microfocused beam. This non-contact, non-destructive technique is well suited for samples of large dimensions (in contrast with traditional resonant X-ray methods based on diffraction from Friedel pairs), and its potential is particularly relevant in the context of physical phenomena connected with an absence of inversion symmetry, which require characterization of the underlying absolute atomic structure (such as in the case of magnetoelectric coupling and multiferroics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Background optimization of powder electron diffraction for implementation of the e-PDF technique and study of the local structure of iron oxide nanocrystals

The local structural characterization of iron oxide nanoparticles is explored using a total scattering analysis method known as pair distribution function (PDF) (also known as reduced density function) analysis. The PDF profiles are derived from background-corrected powder electron diffraction patterns (the e-PDF technique). Due to the strong Coulombic interaction between the electron beam and the sample, electron diffraction generally leads to multiple scattering, causing redistribution of intensities towards higher scattering angles and an increased background in the diffraction profile. In addition to this, the electron–specimen interaction gives rise to an undesirable inelastic scattering signal that contributes primarily to the background. The present work demonstrates the efficacy of a pre-treatment of the underlying complex background function, which is a combination of both incoherent multiple and inelastic scatterings that cannot be identical for different electron beam energies. Therefore, two different background subtraction approaches are proposed for the electron diffraction patterns acquired at 80 kV and 300 kV beam energies. From the least-square refinement (small-box modelling), both approaches are found to be very promising, leading to a successful implementation of the e-PDF technique to study the local structure of the considered nanomaterial.

36 MATERIALS SCIENCE↗

Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This work demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimization of the Total Depth of Internal Saw-Tooth Reliefs of a Two-Layer Relief-Phase Diffraction Microstructure

Results of studying the possibility to decrease the total depth of reliefs of a two-layer microstructure having two internal saw-tooth microreliefs reducing the dependence of the diffraction efficiency of the microstructure on the radiation wavelength and angle of radiation incidence on the microstructure are presented. These results allow one to minimize the complexity of obtaining optimum microrelief depths depending on requirements applicable to the diffraction optical element in the framework of the electromagnetic-diffraction theory. Optimum depths provide in the specified spectral range and interval of angles of radiation incidence the maximum possible (for the chosen width of the narrowest zone of the saw-tooth microrelief) value of the diffraction efficiency at the point of its minimum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗