Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Nuclear-spin observation of noise spectra in semiconductors

We propose a systematic method of obtaining the spectra of noises that cause the decoherence of spins in solids. Based on this method, we experimentally show that this method can be applied to nuclear spins in semiconductors. We clarify that the spectral intensity must be derived from the long-time tail of the multiple-echo decay. To obtain higher-frequency noise, the inversion-pulse interval must be as short as possible, which required us to employ the alternating-phase Carr-Purcell sequence instead of the widely used Carr-Purcell Meiboom-Gill. For {sup 75}As nuclear spin in variously-doped GaAs, we observed a Lorentzian spectrum, instead of the commonly observed 1/f spectrum. This indicates that the nuclear spins are indeed in a coherently-controlled state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoneutron reactions in the range of giant dipole resonance

The well-known significant systematic disagreements between data on partial photoneutron reaction cross sections obtained in experiments using quasimonoenergetic annihilation photons and bremsstrahlung were investigated using objective physical criteria of data reliability. It was shown that many data are not reliable because of significant systematic uncertainties of the photoneutron multiplicity sorting methods used. The experimental-theoretical method for evaluation of reliable partial reaction cross sections was proposed and many new data were obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research Essay for the Goldwater Scholarship Application

Oxygen is found in many natural and human-made structures and materials, including water, concrete, or any oxide. The severe lack of data on the cross section of 16 O(n,α), a reaction that can be found in any material containing oxygen, is detrimental to a complete understanding of the natural or induced behavior of these materials [HYL16]. Additionally, study of this particular reaction and other neutron-induced reactions involving oxygen are useful in the design of naval light water reactors and applications in radio-biology [HYL16]. A detailed understanding of the 16 O(n,α) reaction is vital to the safe and efficient study, design, and development of applications such as these. My consequent work at the Los Alamos National Laboratory (LANL), under the supervision of my mentor, Dr. Hye Young Lee, concerned an experiment to measure the reaction rate of 16 O(n,α) with unprecedented precision, using a method of experimentation known as the ”forward propagating approach.” What separates this method from traditional experimentation is in the use of computer simulations; in essence, this method entails the development of a computer-simulated experimental environment that behaves similarly to a corresponding physical experimental environment (the word ”similar” is used here to convey an equivalence in properties of materials, like geometry or density, and characteristics of certain nuclear processes between the simulated and physical environments). The simulated environment receives inputs, like detector resolution and efficiency, beam resolution, or theoretical calculations of cross sections, that are determined from physically measured results, and then output data that – provided the simulation was prepared and executed properly – closely resemble the results expected from physical execution of the experiment. By comparing data from the simulated experiment and the physical experiment, the relevant results can be constrained to achieve a high precision measurement. The goal of my mentor’s experiment–the experiment that I helped build and simulate–was to achieve a high precision measurement of the cross section of 16 O(n,α) using the forward propagating approach technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water contact angles on quartz surfaces under supercritical CO 2 sequestration conditions: Experimental and molecular dynamics simulation studies

The ambiguity of contact angle experimental measurements due to surface chemistry changes resulted from sample contamination and/or the degrees of reaction with supercritical CO 2 has resulted in great difficulties to precisely understand the wetting behavior of CO 2 under the geological carbon sequestration (GCS) conditions. Water contact angles on quartz surface under GCS conditions were investigated through the combined experimental and molecular dynamics simulation (MDS) methods. The experimental results show that water contact angles increases as ionic strength increases. The effects of pressure and temperature are very weak. The dependence of ionic strength, pressure and temperature is same for monovalent and divalent ions solutions. In the MDS, a hydroxylated quartz surface was used as the base point. A good agreement between the MDS and experimental results were obtained. Using the MDS method, a clean mineral surface with a desired surface chemistry can be constructed, which is difficult in experiments. So by comparing MDS and experimental results, the mechanisms of the reservoir wettability can be better understood. Further investigation can be made on quartz surface with different functional groups to better understand wettability alteration caused by contamination and/or CO 2 reaction.

54 ENVIRONMENTAL SCIENCES↗

Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a maximum uncertainty of 11% (k = 1) found at 1 cm from the source. Radial dose values in water were compared against published results of the American Association of Physicists in Medicine and the European Society for Radiotherapy and Oncology and no significant differences (maximum value of 3.1%) were found within uncertainties except for one position at 9 cm (5.8%). At this location the background contribution relative to the TLD signal is relatively small and an unexpected experimental fluctuation in the background estimate may have caused such a large discrepancy. Conclusions: This paper shows that reliable measurements with TLDs in complex energy spectra require a study of the detector dose response with the radiation quality and specific calibration methodologies which model accurately the experimental conditions where the detectors will be used. The authors have developed and studied a method with highly sensitive TLDs and contributed to its validation by comparison with results from the literature. This methodology can be used to provide direct estimates of the absorbed dose rate in water for irradiations with HDR{sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended experimental inferential structure determination method in determining the structural ensembles of disordered protein states

Proteins with intrinsic or unfolded state disorder comprise a new frontier in structural biology, requiring the characterization of diverse and dynamic structural ensembles. Here we introduce a comprehensive Bayesian framework, the Extended Experimental Inferential Structure Determination (X-EISD) method, which calculates the maximum log-likelihood of a disordered protein ensemble. X-EISD accounts for the uncertainties of a range of experimental data and back-calculation models from structures, including NMR chemical shifts, J-couplings, Nuclear Overhauser Effects (NOEs), paramagnetic relaxation enhancements (PREs), residual dipolar couplings (RDCs), hydrodynamic radii (R h ), single molecule fluorescence Förster resonance energy transfer (smFRET) and small angle X-ray scattering (SAXS). We apply X-EISD to the joint optimization against experimental data for the unfolded drkN SH3 domain and find that combining a local data type, such as chemical shifts or J-couplings, paired with long-ranged restraints such as NOEs, PREs or smFRET, yields structural ensembles in good agreement with all other data types if combined with representative IDP conformers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.

60 APPLIED LIFE SCIENCES↗

On the reliability of HELIOSAT method: A comparison with experimental data

This study deals with comparison of Cameroonian ground based measurements with estimations done using satellite images, by applying the second version of the HELIOSAT method, as computed by the web tool HELIOCLIM of the SoDa project. Measurements and satellite resources were chosen for the same period of the year 1985, on ten Cameroonian locations, distributed with mean spatial resolution of 200 km between two neighbouring stations. Correlations curves are constructed between daily irradiation estimates from satellite data and from measurements. The consequent regression equations are established, using the least square method. Finally, a brief discussion is carried out on the spatial distribution of errors observed on results. Similarly to previous studies this study confirmed the capability of the method to produce good results for the Garoua location, and established its extension on other sahelian sites, comparatively to the poor agreement observed on southern sites. Furthermore, even if the study was not done on a long period, it brought out the necessity to correct the HELIOSAT results for many Cameroonian locations, to march the experimental results. (author)

14 SOLAR ENERGY↗

Methodology of Materials Discovery in Complex Metal Hydrides Using Experimental and Computational Tools

We present a review of the experimental and theoretical methods used in the discovery of new metal-hydrogen materials systems for hydrogen storage applications. Rather than a comprehensive review of all new materials and methods used in the metal hydride community, we focus on a specific subset of successful methods utilizing theoretical crystal structure prediction methods, computational approaches for screening large numbers of compound classes, and medium-throughput experimental methods for the preparation of such materials. Monte Carlo techniques paired with a simplified empirical Hamiltonian provide crystal structure candidates that are refined using Density Functional Theory. First-principle methods using high-quality structural candidates are further screened for an estimate of reaction energetics, decomposition enthalpies, and determination of reaction pathways. Experimental synthesis utilizes a compacted-pellet sintering technique under high-pressure hydrogen at elevated temperatures. Crystal structure determination follows from a combination of Rietveld refinements of diffraction patterns and first-principles computation of total energies and dynamical stability of competing structures. The methods presented within are general and applicable to a wide class of materials for energy storage.

08 HYDROGEN↗

Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the prostate surface and trained to adaptively capture the appearance in different prostate zones, thus achieving better local tissue differentiation. For each local region, multiple classifiers are trained based on the randomly selected samples and finally assembled by a specific fusion method. In addition to this nonparametric appearance model, a prostate shape model is learned from the shape statistics using a novel approach, sparse shape composition, which can model nonGaussian distributions of shape variation and regularize the 3D mesh deformation by constraining it within the observed shape subspace. Results: The proposed method has been evaluated on two datasets consisting of T2-weighted MR prostate images. For the first (internal) dataset, the classification effectiveness of the authors' improved dictionary learning has been validated by comparing it with three other variants of traditional dictionary learning methods. The experimental results show that the authors' method yields a Dice Ratio of 89.1% compared to the manual segmentation, which is more accurate than the three state-of-the-art MR prostate segmentation methods under comparison. For the second dataset, the MICCAI 2012 challenge dataset, the authors' proposed method yields a Dice Ratio of 87.4%, which also achieves better segmentation accuracy than other methods under comparison. Conclusions: A new magnetic resonance image prostate segmentation method is proposed based on the combination of deformable model and dictionary learning methods, which achieves more accurate segmentation performance on prostate T2 MR images.

60 APPLIED LIFE SCIENCES↗

New directions in the search for dark matter

The identification of the nature of dark matter is one of the most important problems confronting particle physics. Current observational constraints permit the mass of the dark matter to range from 10^{-22} 10 − 22 eV - 10^{48} 10 48 GeV. Given the weak nature of these bounds and the ease with which dark matter models can be constructed, it is clear that the problem can only be solved experimentally. In these lectures, I discuss methods to experimentally probe a wide range of dark matter candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of spin frustration in an Fe III 7 cluster using a combination of computational, experimental, and magnetostructural correlation methods

The synthesis, structure, and magnetic properties are reported for [Fe 7 O 3 (O 2 C t Bu) 9 (mda) 3 (H 2 O) 3 ] ( 1 ), where mdaH 2 is N -methyldiethanolamine. 1 was prepared from the reaction of [Fe 3 O(O 2 C t Bu) 6 (H 2 O) 3 ](NO 3 ) with mdaH 2 in a 1:~3 ratio in MeCN. The core of 1 consists of a central octahedral Fe III ion held within a non-planar Fe 6 loop by three μ 3 -O 2- and three μ 2 -RO - arms from the three mda 2- chelates. Variable-temperature dc and ac magnetic susceptibility studies revealed dominant antiferromagnetic coupling, leading to a ground state spin of S = 5 / 2 . The ground state was confirmed by a fit of magnetization data collected in the 0.1–7.0 T and 1.8–10.0 K ranges. The four Fe 2 pairwise exchange parameters ( J 1 - J 4 ) were estimated by independent methods: theoretical calculations using either broken symmetry energy differences (-46.3, -16.2, -3.9, and - 28.1 cm -1 , respectively) or Green’s function approximation methods (-41.4, -14.8, -13.2, and - 24.7 cm -1 ), and a magnetostructural correlation (MSC) previously developed for high nuclearity Fe III /O complexes (-39.5, -13.8, -6.7, and - 23.5 cm -1 ). Additionally, the J 1 - J 4 obtained from the MSC and theoretical methods were used with the program PHI to both simulate χ M T vs T as well as to serve as reasonable input values to fit the experimental data (-41.0, -11.4, -5.0, and - 27.3 cm -1 ). Analysis of the J ij led to identification of the spin frustration effects operative and the resultant spin vector alignments at each Fe III ion, thus allowing for the rationalization of the experimental ground state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In pursuit of an accurate spatial and temporal model of biomolecules at the atomistic level: a perspective on computer simulation

The current computational techniques available for biomolecular simulation are described, and the successes and limitations of each with reference to the experimental biophysical methods that they complement are presented. Despite huge advances in the computational techniques available for simulating biomolecules at the quantum-mechanical, atomistic and coarse-grained levels, there is still a widespread perception amongst the experimental community that these calculations are highly specialist and are not generally applicable by researchers outside the theoretical community. In this article, the successes and limitations of biomolecular simulation and the further developments that are likely in the near future are discussed. A brief overview is also provided of the experimental biophysical methods that are commonly used to probe biomolecular structure and dynamics, and the accuracy of the information that can be obtained from each is compared with that from modelling. It is concluded that progress towards an accurate spatial and temporal model of biomacromolecules requires a combination of all of these biophysical techniques, both experimental and computational.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Zirconium and Yttrium (p, d) Surrogate Nuclear Reactions: Measurement and determination of gamma-ray probabilities: Experimental Physics Report

This technical report documents the surrogate reaction method and experimental results used to determine the desired neutron induced cross sections of 87 Y(n,g) and the known 90 Zr(n,g) cross section. This experiment was performed at the STARLiTeR apparatus located at Texas A&M Cyclotron Institute using the K150 Cyclotron which produced a 28.56 MeV proton beam. The proton beam impinged on Y and Zr targets to produce the nuclear reactions 89 Y(p,d) 88 Y and 92 Zr(p,d) 91 Zr. Both particle singles data and particle-gamma ray coincident data were measured during the experiment. This data was used to determine the γ-ray probability as a function of energy for these reactions. The results for the γ-ray probabilities as a function of energy for both these nuclei are documented here. For completeness, extensive tabulated and graphical results are provided in the appendices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy

Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current advances in synchrotron radiation instrumentation for MX experiments

Following pioneering work 40 years ago, synchrotron beamlines dedicated to macromolecular crystallography (MX) have improved in almost every aspect as instrumentation has evolved. Beam sizes and crystal dimensions are now on the single micron scale while data can be collected from proteins with molecular weights over 10 MDa and from crystals with unit cell dimensions over 1000 Å. Furthermore it is possible to collect a complete data set in seconds, and obtain the resulting structure in minutes. The impact of MX synchrotron beamlines and their evolution is reflected in their scientific output, and MX is now the method of choice for a variety of aims from ligand binding to structure determination of membrane proteins, viruses and ribosomes, resulting in a much deeper understanding of the machinery of life. A main driving force of beamline evolution have been advances in almost every aspect of the instrumentation comprising a synchrotron beamline. In this review we aim to provide an overview of the current status of instrumentation at modern MX experiments. The most critical optical components are discussed, as are aspects of endstation design, sample delivery, visualisation and positioning, the sample environment, beam shaping, detectors and data acquisition and processing.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental quantification of “hardenability” of 2195 and 2050 Al-Li alloys by using cold-rolled sheets

Highlights: • An experimental simulation method for intuitive “hardenability” evaluation. • With increasing the distance from the quenching end, the strength of 2050 alloy lowers more slowly than that of 2195 alloy, indicating its better “hardenability”. • At the location far away from the quenching end, lenticular-shaped phases form within grains, which impede T1 precipitation at the same local location during the following aging process. • More intra-granular lenticular-shaped phases in 2195 Al-Li alloy corresponds to its lower “hardenability”. - Abstract: To effectively and intuitively evaluate the “hardenability” during the design of new heat-treatable Al alloys, an experimental evaluation method by using cold-rolled thin sheets was proposed, which combined end-quenching with tensile test after aging, and eliminated the effect of different original structure of thick plate through-thickness. The “hardenability” of 2050 and 2195 Al-Li alloys was then intuitively characterized by their strength lowering as a function of distance away from the quenching end after T8-aging following end-quenching. As the distance is increased, the strength of the 2050 Al-Li alloy lowers more slowly than that of the 2195 Al-Li alloy, indicating a better “hardenability” of the 2050 Al-Li alloy. At the location with a certain distance away from the quenching end, in addition to the Cu-rich secondary phases at the grain boundary, lenticular-shaped Cu-containing secondary phases also form within grains during the end quenching process, which impede the precipitation of T1 (Al{sub 2}CuLi) phase at the same local location during the following aging process. More importantly, the number of the intra-granular lenticular-shaped phases in the 2195 Al-Li alloy is much more than that in the 2050 Al-Li alloy, which contributes to a less “hardenability” of the 2195 Al-Li alloy.

36 MATERIALS SCIENCE↗