Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Sensitivity of Pyrocumulus Convection to Tree Mortality During the 2020 Creek Fire in California

Abstract This study investigated the sensitivity of pyrocumulonimbus (PyroCb) induced by the California Creek fire of 2020 to the amount and type of surface fuels, within the WRF‐SFIRE modeling system. Satellite data were used to derive fire arrival times to constrain fire progression, and to augment the fuel characterization with better estimates of combustible vegetation accounting for tree mortality. Machine learning was employed to classify standing dead vegetation from aerial imagery, which was then added as a custom fuel class along with the standard Anderson fuel categories. Simulations using this new fuel class produced a larger and more vigorous PyroCb than the control run, however, still under‐predicted the cloud top. Additional augmentation of fuel mass to represent the accumulation of dead vegetation on the forest floor further improved the simulations, demonstrating the efficacy of representing both dead standing and fallen vegetation to produce more realistic PyroCb and smoke simulations.

54 ENVIRONMENTAL SCIENCES↗

The use of computer models to predict temperature and smoke movement in high bay spaces

The Building and Fire Research Laboratory (BFRL) was given the opportunity to make measurements during fire calibration tests of the heat detection system in an aircraft hangar with a nominal 30.4 (100 ft) ceiling height near Dallas, TX. Fire gas temperatures resulting from an approximately 8250 kW isopropyl alcohol pool fire were measured above the fire and along the ceiling. The results of the experiments were then compared to predictions from the computer fire models DETACT-QS, FPETOOL, and LAVENT. In section A of the analysis conducted, DETACT-QS AND FPETOOL significantly underpredicted the gas temperature. LAVENT at the position below the ceiling corresponding to maximum temperature and velocity provided better agreement with the data. For large spaces, hot gas transport time and an improved fire plume dynamics model should be incorporated into the computer fire model activation routines. A computational fluid dynamics (CFD) model, HARWELL FLOW3D, was then used to model the hot gas movement in the space. Reasonable agreement was found between the temperatures predicted from the CFD calculations and the temperatures measured in the aircraft hangar. In section B, an existing NASA high bay space was modeled using the CFD model. The NASA space was a clean room, 27.4 m (90 ft) high with forced horizontal laminar flow. The purpose of this analysis is to determine how the existing fire detection devices would respond to various size fires in the space. The analysis was conducted for 32 MW, 400 kW, and 40 kW fires.

Notarianni, Kathy A.↗

Performance and Safety Evaluations of Moli Spinel Lithium-Ion Cells

The current spike obtained during the hard external short test is small (8.2 A) compared to those obtained from a LiCoO2 system (60 to 80 A). The simulated internal short did not result in an explosion or fire as it does with the LiCoO2 systems. The temperatures obtained during the heat-to-vent test are not very high compared to the cobaltate cells. The cells do not retain capacity very well, but the capacity can be recovered with cycling. The spinel cells are much safer under abuse conditions than the lithium-ion cells with other transition metal oxides.

Jevarajan, Judith↗

Mobile satellite communications in the Forest Service

There are usually some places within a forest that do not have adequate communication coverage due to line-of-sight or other reasons. These areas are generally known by the foresters and radio technicians and allowances are made for that when working or traveling in those areas. However, when wildfire or other emergencies occur, communications are vital because wildfires can require hundreds of firefighters and cover thousands of acres. During these emergency operations, the existing communications are not adequate and complete radio systems are moved into the area for the conduct of fire communications. Incident command posts (ICPs) and fire camps are set up in remote locations and there is constant need for communications in the fire area and to agency headquarters and dispatch offices. Mobile satellite communications would be an ideal supplement to the Forest Service's current communications system in aiding forest fire control activities.

Warren, John R.↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

New Technology for the Fire Attire

Although little can be done to reduce the risks of firefighting, something can be done to curb the injuries and fatalities. This is the goal of Project FIRES, a program jointly sponsored by NASA and the Federal Emergency Management Agency's U.S. Fire Administration with technical management provided by Marshall Space Flight Center. Project FIRES (Firefighter's Integrated Response Equipment System) involves applications of advanced materials and design concepts, derived from Apollo to update existing gear which does not adequately protect against many of the hazards encountered in fire suppression activities. A major focus of the effort involves application to the FIRES ensemble of lightweight, fire-resistant, heat-protective materials originally developed for use in astronauts' space suits or in spacecraft components which require thermal protection. Data from the fourteen municipal fire departments participating in the field evaluation will form a basis for development of new nationwide protective ensemble students.

Source record↗

Improving the Cost-Effectiveness of Algal CO2 Utilization by Synergistic Integration With Power Plant and Wastewater Treatment Operations

Creating an economic demand for carbon utilization products will require lowering the overall cost of the products to compete within the current market. Photosynthetic uptake of carbon dioxide is an emerging pathway for product development in the animal feed market that globally amounts to over 400 Billion USD and is expected to continue growing. This project aims to continue the development of a process that utilizes carbon dioxide while increasing the cost competitiveness of algae as an animal feed product. The overall goal of the project is to demonstrate an engineering-scale open raceway pond algae cultivation system (180 m2) including integration of technologies that utilize coal-fired power plant CO2 and wastewater nutrient inputs. The system is designed to maximize the cost-effectiveness and environmental benefits of algal biomass production for commodity animal feed.

20 FOSSIL-FUELED POWER PLANTS↗

Assessment of industrial applications for fuel cell cogeneration systems

The fuel cell energy systems are designed with and without a utility connection for emergency back-up power. Sale of electricity to the utility during periods of low plant demand is not considered. For each of the three industrial applications, conceptual designs were also developed for conventional utility systems relying on purchased electric power and fossil-fired boilers for steam/hot water. The capital investment for each energy system is estimated. Annual operating costs are also determined for each system. These cost estimates are converted to levelized annual costs by applying appropriate economic factors. The breakeven electricity price that would make fuel cell systems competitive with the conventional systems is plotted as a function of naphtha price. The sensitivity of the breakeven point to capital investment and coal price is also evaluated.

Stickles, R. P.↗

Machine learning to predict final fire size at the time of ignition

Fires in boreal forests of Alaska are changing, threatening human health and ecosystems. Given expected increases in fire activity with climate warming, insight into the controls on fire size from the time of ignition is necessary. Such insight may be increasingly useful for fire management, especially in cases where many ignitions occur in a short time period. Here we investigated the controls and predictability of final fire size at the time of ignition. Using decision trees, we show that ignitions can be classified as leading to small, medium or large fires with 50.4 ± 5.2% accuracy. This was accomplished using two variables: vapour pressure deficit and the fraction of spruce cover near the ignition point. The model predicted that 40% of ignitions would lead to large fires, and those ultimately accounted for 75% of the total burned area. Other machine learning classification algorithms, including random forests and multi-layer perceptrons, were tested but did not outperform the simpler decision tree model. Applying the model to areas with intensive human management resulted in overprediction of large fires, as expected. This type of simple classification system could offer insight into optimal resource allocation, helping to maintain a historical fire regime and protect Alaskan ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Recent NASA Dryden COA Experience

This viewgraph presentation concerns the experience that Dryden has had with Certificate of Authorization (COA) in reference to unmanned aerial systems (UAS). It reviews recent Certificate of Authorization UAS's i.e., 2005 Altair NOAA Mission, 2006 Altair Western States Fire Mission, and 2007 Ikhana. The priorities for the safety process is reviewed, as are typical UAS hazards. Slides also review the common COA provisions, best practices and lessons learned, the 2005 NOAA/NASA Science Demonstration Flights and the use of the UAS systems during fire emergencies.

Cobleigh, Brent↗

Resilience of terrestrial and aquatic fauna to historical and future wildfire regimes in western North America

Wildfires in many western North American forests are becoming more frequent, larger, and severe, with changed seasonal patterns. In response, coniferous forest ecosystems will transition toward dominance by fire-adapted hardwoods, shrubs, meadows, and grasslands, which may benefit some faunal communities, but not others. We describe factors that limit and promote faunal resilience to shifting wildfire regimes for terrestrial and aquatic ecosystems. We highlight the potential value of interspersed nonforest patches to terrestrial wildlife. Similarly, we review watershed thresholds and factors that control the resilience of aquatic ecosystems to wildfire, mediated by thermal changes and chemical, debris, and sediment loadings. We present a 2-dimensional life history framework to describe temporal and spatial life history traits that species use to resist wildfire effects or to recover after wildfire disturbance at a metapopulation scale. The role of fire refuge is explored for metapopulations of species. In aquatic systems, recovery of assemblages postfire may be faster for smaller fires where unburned tributary basins or instream structures provide refuge from debris and sediment flows. We envision that more-frequent, lower-severity fires will favor opportunistic species and that less-frequent high-severity fires will favor better competitors. Along the spatial dimension, we hypothesize that fire regimes that are predictable and generate burned patches in close proximity to refuge will favor species that move to refuges and later recolonize, whereas fire regimes that tend to generate less-severely burned patches may favor species that shelter in place. Looking beyond the trees to forest fauna, we consider mitigation options to enhance resilience and buy time for species facing a no-analog future.

54 ENVIRONMENTAL SCIENCES↗

A novel means to flexibly operate a hybrid concentrated solar power plant and improve operation during non-ideal direct normal irradiation conditions

Hybridization of concentrated solar power (CSP) with other energy sources can drastically increase how much solar energy is harnessed and potentially expand the current geographical deployment of CSP installlations. In this study, a novel operation strategy referred to as flexible heat integration (FHI), is proposed and applied to a hybrid CSP-natural gas power plant. The proposed plant, modeled in Simulink, employs a solar central receiver (SCR) and dual-source gas boiler to drive a steam Rankine power cycle. FHI involves collecting and dispatching solar energy at modified temperatures during off-design direct normal irradiance (DNI). During low-grade (<100 W/m 2 ) and medium-grade (100–500 W/m 2 ) levels of DNI, molten salt is used for steam boiling and feedwater preheating, respectively, rather than superheating usually seen in SCR steam plants. Hybrid gas-firing supplies energy to bypassed systems. FHI is applied to a hybrid plant over the course of a day from each season for a plant located in Salt Lake City, Utah, an unconventional location due to off-design DNI variability. A spring day exhibiting variable DNI is used as the main case study to demonstrate the dynamics and robust operation under the FHI framework. The operation of the plant over the winter day shows the largest improvement in solar-to-electric (STE) efficiency whereas the summer day exhibits the smallest improvement. Monthly results follow a similar trend with FHI improving STE from 15.3% and 16.3% to 17.0% and 16.7% in January and July, respectively. Yearly results show FHI improving STE efficiency from 16.1% to 17.1% relative to standard hybrid operation. Altogether, the proposed concept expands the current understanding of energy management in hybrid SCR-natural power plants under non-ideal DNI conditions and locations that have lower DNI by applying FHI.

14 SOLAR ENERGY↗

X-ray micro-tomography investigation of the foaming process in the system of waste glass–silica mud–MnO{sub 2}

In case of foamed lightweight aggregates (LWAs), porosity is introduced by the addition of a foaming agent to the glassy matrix, which degasses at an elevated temperature, so that the resulting gases remain trapped inside the glassy structure. The efficiency of action of MnO{sub 2} as a foaming agent in waste glass and waste glass/silica mud systems was studied. Samples were fired at different temperatures and with different dwelling times at a certain temperature, and the development of porosity was investigated by means of X-ray micro-tomography. It was found that, with the prolongation in dwelling times, the number of pores decreased, while, on the other hand, the volume of these pores increased, and that the addition of silica mud increases the foaming temperature and slows down the foaming process. - Highlights: • Preparation of lightweight aggregate from waste glass, silica sludge, and MnO{sub 2} • DTA/TG investigation of MnO{sub 2} • Characterization of pore-forming process by means of X-ray micro-tomography (μcT)

36 MATERIALS SCIENCE↗

Impacts of Wildfire Aerosols on Global Energy Budget and Climate: The Role of Climate Feedbacks

Aerosols emitted from wildfires could significantly affect global climate through perturbing global radiation balance. In this study, the Community Earth System Model with prescribed daily fire aerosol emissions is used to investigate fire aerosols’ impacts on global climate with emphasis on the role of climate feedbacks. The total global fire aerosol radiative effect (RE) is estimated to be -0.78 ± 0.29 W m -2 , which is mostly from shortwave RE due to aerosol–cloud interactions (REaci; -0.70 ± 0.20 W m -2 ). The associated global annual-mean surface air temperature (SAT) change ΔT is -0.64 ± 0.16 K with the largest reduction in the Arctic regions where the shortwave REaci is strong. Associated with the cooling, the Arctic sea ice is increased, which acts to reamplify the Arctic cooling through a positive ice-albedo feedback. The fast response (irrelevant to ΔT) tends to decrease surface latent heat flux into atmosphere in the tropics to balance strong atmospheric fire black carbon absorption, which reduces the precipitation in the tropical land regions (southern Africa and South America). The climate feedback processes (associated with ΔT) lead to a significant surface latent heat flux reduction over global ocean areas, which could explain most (~80%) of the global precipitation reduction. The precipitation significantly decreases in deep tropical regions (5°N) but increases in the Southern Hemisphere tropical ocean, which is associated with the southward shift of the intertropical convergence zone and the weakening of Southern Hemisphere Hadley cell. Such changes could partly compensate the interhemispheric temperature asymmetry induced by boreal forest fire aerosol indirect effects, through intensifying the cross-equator atmospheric heat transport.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Energy Savings and Thermal Comfort Improvements Derived from Using Interior Storm Windows

This field study of a single historic home in Seattle, WA documents the performance of Indow ® Windows’s interior storm window inserts. Energy use and the temperature profile of the house were monitored before and after the installation of the window inserts and changes in the two recorded metrics were examined. Using the defined analysis approach, it was determined that the interior storm windows produced a 22% reduction of the HVAC energy bill and had an undetermined effect on the thermal comfort in the house. Although there was no measurable changes in the thermal comfort of the house, the occupant noted the house to be “warmer in the winter and cooler in the summer” and that the “temperatures are more even (throughout the house).” The interior storm windows were found to be not cost effective, largely due to the retrofits completed on its heating system. However, if the economic analysis was conducted based on the old heating system, a 72% efficient oil fired furnace, the Indow Windows proved to be economical and had a simple payback period of 9.0 years.

high performance housing↗

Project Closeout Report for the MFC Firewater Replacement Project

The Material and Fuels Complex (MFC) Firewater Replacement Project was an indirectly funded Institutional General Plant Project (IGPP) capital acquisition initiated in July 2013 and completed in June 2016. Its purpose was to improve the capacity, redundancy and reliability of the MFC fire water and potable water systems, making them compliant with DOE O 420.1C and applicable state and federal regulations.

99 GENERAL AND MISCELLANEOUS↗