Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Light Duty Engine Performance Characteristics with Dimethyl Ether and Propane

Here, this paper explores the performance characteristics of a compression ignition HYUNDAI 2.2L engine operating with Dimethyl Ether (DME). Test are carried out at three operating conditions that weigh heavily in the FTP75 certification cycle (1000rpm-12Nm, 1500rpm-50Nm, 2000rpm-100Nm). The engine features a high-pressure common rail fuel injection system designed to operate with liquified gases. The main component of the fuel system is a high-pressure pump that incorporates an electronic inlet metering valve commanded on a crank-angle base to control the rail pressure. The pump, which requires no pressure regulator, provides the flow needed to the injectors without flow returning to the inlet. This novel fueling system is leveraged in tests that are conducted to examine the impact of EGR, combustion phasing, injection pressure on efficiency and emissions. In addition, the impact of introducing 15% Propane by mass is examined. During the tests, the engine ECU is aided by an Engine Controller High Speed Oversight unit (ECHO) to provide combustion phasing control, improved cylinder-to-cylinder uniformity, and an effective optimization over the testing effort. The use of DME and Propane allowed for peak thermal efficiency of nearly 43%. These fuels enable significant carbon index (CI) reductions over the baseline Diesel fuel, with indications that 50% reduction in CO 2 over the Diesel engine are possible.

33 ADVANCED PROPULSION SYSTEMS↗

Altitude test of several afterburner configurations on a turbofan engine with a hydrogen heater to simulate an elevated turbine discharge temperature

A performance test of several experimental afterburner configurations was conducted with a mixed-flow turbofan engine in an altitude facility. The simulated flight conditions were for Mach 1.4 at two altitudes, 12,190 and 14,630 meters. Turbine discharge temperatures of 889 and 1056 K were used. A production afterburner was tested for comparison. The research afterburners included partial forced mixers with V-gutter flameholders, a carburetted V-gutter flameholder, and a triple ring V-gutter flameholder with four swirl-can fuel mixers. Fuel injection variations were included. Performance data shown include augmented thrust ratio, thrust specific fuel consumption, combustion efficiency, and total pressure drop across the afterburner.

Johnsen, R. L.↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

High Reynolds Number Investigation of a Flush-Mounted, S-Duct Inlet With Large Amounts of Boundary Layer Ingestion

An experimental investigation of a flush-mounted, S-duct inlet with large amounts of boundary layer ingestion has been conducted at Reynolds numbers up to full scale. The study was conducted in the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. In addition, a supplemental computational study on one of the inlet configurations was conducted using the Navier-Stokes flow solver, OVERFLOW. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on aerodynamic interface plane diameter) from 5.1 million to 13.9 million (full-scale value), and inlet mass-flow ratios from 0.29 to 1.22, depending on Mach number. Results of the study indicated that increasing Mach number, increasing boundary layer thickness (relative to inlet height) or ingesting a boundary layer with a distorted profile decreased inlet performance. At Mach numbers above 0.4, increasing inlet airflow increased inlet pressure recovery but also increased distortion. Finally, inlet distortion was found to be relatively insensitive to Reynolds number, but pressure recovery increased slightly with increasing Reynolds number.

Berrier, Bobby L.↗

High Reynolds Number Investigation of a Flush Mounted, S-Duct Inlet With Large Amounts of Boundary Layer Ingestion

An experimental investigation of a flush-mounted, S-duct inlet with large amounts of boundary layer ingestion has been conducted at Reynolds numbers up to full scale. The study was conducted in the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. In addition, a supplemental computational study on one of the inlet configurations was conducted using the Navier-Stokes flow solver, OVERFLOW. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on aerodynamic interface plane diameter) from 5.1 million to 13.9 million (full-scale value), and inlet mass-flow ratios from 0.29 to 1.22, depending on Mach number. Results of the study indicated that increasing Mach number, increasing boundary layer thickness (relative to inlet height) or ingesting a boundary layer with a distorted profile decreased inlet performance. At Mach numbers above 0.4, increasing inlet airflow increased inlet pressure recovery but also increased distortion. Finally, inlet distortion was found to be relatively insensitive to Reynolds number, but pressure recovery increased slightly with increasing Reynolds number.This CD-ROM supplement contains inlet data including: Boundary layer data, Duct static pressure data, performance-AIP (fan face) data, Photos, Tunnel wall P-PTO data and definitions.

Berrier, Bobby L.↗

Effect of Surface Traffic Count on Taxi Time at Dallas-Fort Worth (DFW) International Airport

As the amount of air traffic increases over the years, most airports simply do not have the means of expanding to handle the intensified traffic on the surface that will ensue. Precise surveillance equipment and automation concepts, as well as advanced surface traffic algorithms are being developed to improve airport efficiency. These surface algorithms require inputs unique to each airport to ensure maximum efficiency, and minimal taxi delay. This study analyzes surface traffic at Dallas-Fort Worth International Airport (DFW) to determine the effect of the number of aircraft on the surface and the amount of stop and go situations they experience to the amount of additional taxi time encountered. If the surface capacity of an airport is known, minimal delay can be accomplished by limiting the number of taxiing aircraft to that capacity. This concept is related to highways, where traffic flow drastically decreases as more cars occupy the road. An attempt to minimize this effect on highways is seen with the use of metering lights at freeway on-ramps. Since the surface traffic at airports is highly regulated, and aircraft are less mobile on the ground, limiting the surface count to a certain number can greatly reduce the amount of additional taxi time encountered, as well as reduce hazardous emissions. This study will also find the regions of an airport that encounter the most additional taxi time when the number of aircraft in that area is increased. This could help surface traffic algorithms avoid congesting that area, or re-route aircraft to different runways when that area reaches its capacity. The relationship between the amount of stop and go situations an aircraft encounters and their effect on the taxi time of that aircraft will also be investigated. This will help to determine the effect of holding an aircraft on the taxiway as opposed to re-routing it. The lesser of the two should be used when developing surface traffic algorithms to further minimize the delay encountered. The fields investigated in this study include taxi time, the number of aircraft on the surface, the number of stop and go situations, and the time stopped for each aircraft. Taxi time is defined as spot to runway for departures, and runway to spot for arrivals. It does not include ramp area taxi time because the ramp area is controlled differently, and surface traffic schedulers do not currently incorporate them. Taxi time is found by finding the difference between take-off time (OFF) and spot crossing time for departures, and spot crossing time and landing time (ON) for arrivals. All surface data was either found directly using the Surface Operations Data Analysis and Adaptation (SODAA), a tool to analyze the Surface Management System (SMS) generated log files, or indirectly from SODAA using Matlab to derive values from SODAA data. The number of aircraft on the surface is found by looping through the ON times, OFF times, and spot times for each aircraft during a particular day. For each departure aircraft, surface counts are taken at its spot crossing and OFF time. The average of these two is used as the surface count for that aircraft. For arrivals, surface counts are taken at its ON time and its spot crossing time. The average of these two is used.

Kistler, Matthew Stephen↗

Stochastic multi-period optimal dispatch of energy storage in unbalanced distribution feeders

This report presents a convex, multi-period, AC-feasible Optimal Power Flow (OPF) framework that robustly dispatches flexible demand-side resources in unbalanced distribution feeders against uncertainty in very-short timescale solar Photo-Voltaic (PV) forecasts. This is valuable for power systems with significant behind-the-meter solar PV generation as their operation is affected by uncertainty from forecasts of demand and solar PV generation. The aim of this work is then to ensure the feasibility and reliability of distribution system operation under high solar PV penetration. We develop and present a novel, robust OPF formulation that accounts for both the nonlinear power flow constraints and the uncertainty in forecasts. This is achieved by linearizing an optimal trajectory and using first-order methods to systematically tighten voltage bounds. Case studies on a realistic distribution feeder shows the effectiveness of a receding-horizon implementation.

25 ENERGY STORAGE↗

Numerical modeling of groundwater flow in the Navajo sandstone aquifer at the Tuba city, Arizona, disposal site - 15167

A numerical model is being developed to describe groundwater flow in the Navajo Sandstone aquifer that underlies the US DOE Office of Legacy Management Tuba City disposal site that is located near Tuba City, Arizona. The site is a former uranium-ore processing mill that operated from 1956 until 1966. Resulting groundwater contamination extends approximately 457 meters (1,500 feet) off the site. The primary contaminants are nitrate, sulfate, and uranium. Onsite solid waste encapsulation was completed by 1990 and pump-and-treat groundwater remediation was implemented in 2002. A site conceptual model, along with an approach to numerically simulate groundwater flow and advective transport of contaminants at the site, is being developed. Numerical model calibration will address transient periods of active and inactive groundwater withdrawal during the remedial action. The calibrated model will be applied to forecast contaminant capture under the current and hypothetical groundwater extraction scenarios. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reuse of Produced Water from CO 2 Enhanced Oil Recovery, Coal-Bed Methane, and Mine Pool Water by Coal-Based Power Plants

Power generation in the Illinois Basin is expected to increase by as much as 30% by the year 2030, and this would increase the cooling water consumption in the region by approximately 40%. This project investigated the potential use of produced water from CO 2 enhanced oil recovery (CO 2 -EOR) operations; coal-bed methane (CBM) recovery; and active and abandoned underground coal mines for power plant cooling in the Illinois Basin. Specific objectives of this project were: (1) to characterize the quantity, quality, and geographic distribution of produced water in the Illinois Basin; (2) to evaluate treatment options so that produced water may be used beneficially at power plants; and (3) to perform a techno-economic analysis of the treatment and transportation of produced water to thermoelectric power plants in the Illinois Basin. Current produced water availability within the basin is not large, but potential flow rates up to 257 million liters per day (68 million gallons per day (MGD)) are possible if CO 2 -enhanced oil recovery and coal bed methane recovery are implemented on a large scale. Produced water samples taken during the project tend to have dissolved solids concentrations between 10 and 100 g/L, and water from coal beds tends to have lower TDS values than water from oil fields. Current pretreatment and desalination technologies including filtration, adsorption, reverse osmosis (RO), and distillation can be used to treat produced water to a high quality level, with estimated costs ranging from $2.6 to $10.5 per cubic meter ($10 to $40 per 1000 gallons). Because of the distances between produced water sources and power plants, transportation costs tend to be greater than treatment costs. An optimization algorithm was developed to determine the lowest cost pipe network connecting sources and sinks. Total water costs increased with flow rate up to 26 million liters per day (7 MGD), and the range was from $4 to $16 per cubic meter ($15 to $60 per 1000 gallons), with treatment costs accounting for 13-23% of the overall cost. Results from this project suggest that produced water is a potential large source of cooling water, but treatment and transportation costs for this water are large.

20 FOSSIL-FUELED POWER PLANTS↗

Mud Volcanoes - Analogs to Martian Cones and Domes (by the Thousands!)

Mud volcanoes are mounds formed by low temperature slurries of gas, liquid, sediments and rock that erupt to the surface from depths of meters to kilometers. They are common on Earth, with estimates of thousands onshore and tens of thousands offshore. Mud volcanoes occur in basins with rapidly-deposited accumulations of fine-grained sediments. Such settings are ideal for concentration and preservation of organic materials, and mud volcanoes typically occur in sedimentary basins that are rich in organic biosignatures. Domes and cones, cited as possible mud volcanoes by previous authors, are common on the northern plains of Mars. Our analysis of selected regions in southern Acidalia Planitia has revealed over 18,000 such features, and we estimate that more than 40,000 occur across the area. These domes and cones strongly resemble terrestrial mud volcanoes in size, shape, morphology, associated flow structures and geologic setting. Geologic and mineralogic arguments rule out alternative formation mechanisms involving lava, ice and impacts. We are studying terrestrial mud volcanoes from onshore and submarine locations. The largest concentration of onshore features is in Azerbaijan, near the western edge of the Caspian Sea. These features are typically hundreds of meters to several kilometers in diameter, and tens to hundreds of meters in height. Satellite images show spatial densities of 20 to 40 eruptive centers per 1000 square km. Many of the features remain active, and fresh mud flows as long as several kilometers are common. A large field of submarine mud volcanoes is located in the Gulf of Cadiz, off the Atlantic coasts of Morocco and Spain. High-resolution sonar bathymetry reveals numerous km-scale mud volcanoes, hundreds of meters in height. Seismic profiles demonstrate that the mud erupts from depths of several hundred meters. These submarine mud volcanoes are the closest morphologic analogs yet found to the features in Acidalia Planitia. We are also conducting laboratory analyses of surface samples collected from mud volcanoes in Azerbaijan, Taiwan and Japan. X-ray diffraction, visible / near infrared reflectance spectroscopy and Raman spectroscopy show that the samples are dominated by mixed-layer smectite clays, along with quartz, calcite and pyrite. Thin section analysis by optical and scanning electron microscopy confirms the mineral identifications. These samples also contain chemical and morphological biosignatures, including common microfossils, with evidence of partial replacement by pyrite. The bulk samples contain approximately 1 wt% total organic carbon and 0.4 mg / gm volatile hydrocarbons. The thousands of features in Acidalia Planitia cited as analogous to terrestrial mud volcanoes clearly represent an important element in the sedimentary record of Mars. Their location, in the distal depocenter for massive Hesperian-age floods, suggests that they contain fine-grained sediments from a large catchment area in the martian highlands. We have proposed these features as a new class of exploration target that can provide access to minimally-altered material from significant depth. By analogy to terrestrial mud volcanoes, these features may also be excellent sites for the sampling martian organics and subsurface microbial life, if such exist or ever existed.

Allen, Carlton C.↗

DUST CONCENTRATION AT THE BOUNDARY BETWEEN STEADY SUPER/SUB-KEPLERIAN FLOW CREATED BY INHOMOGENEOUS GROWTH OF MAGNETO-ROTATIONAL INSTABILITY

How planetesimals are created from tiny dust particles in a proto-planetary disk before the dust particles spiral to the central star is one of the most challenging problems in the theory of planetary system formation. In our previous paper, we have shown that a steady angular velocity profile that consists of both super- and sub-Keplerian regions is created in the disk through non-uniform excitation of magneto-rotational instability (MRI). Such non-uniform MRI excitation is reasonably expected in a part of disks with relatively low ionization degree. In this paper, we show through three-dimensional resistive MHD simulations with test particles that this radial structure of the angular velocity indeed leads to the prevention of spiral-in of dust particles and furthermore to their accumulation at the boundary of super-Keplerian and sub-Keplerian regions. Treating dust particles as test particles, their motions under the influence of the non-uniform MRI through gas drag are simulated. In the most favorable cases (meter-size dust particles in the disk region with a relatively large fraction of MRI-stable region), we found that the dust concentration is peaked around the super/sub-Keplerian flow boundary and the peak dust density is 10,000 times as high as the initial value. The peak density is high enough for the subsequent gravitational instability to set in, suggesting a possible route to planetesimal formation via non-uniformly excited MRI in weakly ionized regions of a disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-simultaneous Polar and DMSP Measurements of Topside Ionospheric Field-Aligned Flows at High Latitudes

Near-simultaneous observations of topside O(+) parallel flows are presented for four periods of measurement by the Polar and DMSP satellites during April 1996. The Polar measurements were from southern perigee measurements near 5000 km altitude, while the DMSP measurements were from 840 km altitude. In general, the velocities were upward at expected cleft and auroral latitudes, typically about 2-10 km per second at 5000 km altitude, and 0-2 km per second at 840 km altitude. At the highest, polar cap latitudes, downward velocities were more frequent at both altitudes, but especially at the lower 840 km altitude. The downward velocities were typically a few hundred meters per second at 840 km altitude, and 0-1 km per second at 5000 km altitude. In some instances, downward velocities were observed at 840 km altitude while upward O(+) flows were observed at 5000 km altitude, possibly on the same flux tube. The O(+) densities were characteristically 10(exp 3) - 10(exp 4) O(+) at 5000 km altitude and 10(exp 3) - 10(exp 4) O(+) cm (exp -3) at 840 km altitude, while the O(+) fluxes were characteristically 10(exp 5) - 10(exp 7) O(+) cm(exp -2) per second at 5000 km altitude and characteristically 10(exp 7) - 10(exp 9) O(+) cm(exp -2) per second at 840 km altitude. We have also examined the dual-altitude parameter measurements for a polar cap field line, the Polar and DMSP measurements approximately 30 min apart, and compared them with results from a transport simulation. The simulated high-altitude velocity altitude profiles for the period during and after the initiation of the auroral processes generally bracketed the observations, but the observed downward velocities (500 - 600 m per second) at 840 km altitude were much larger in magnitude than those observed at both altitudes.

Zeng, W.↗

Tracking Energy Flow Using a Volumetric Acoustic Intensity Imager (VAIM)

A new measurement device has been invented at the Naval Research Laboratory which images instantaneously the intensity vector throughout a three-dimensional volume nearly a meter on a side. The measurement device consists of a nearly transparent spherical array of 50 inexpensive microphones optimally positioned on an imaginary spherical surface of radius 0.2m. Front-end signal processing uses coherence analysis to produce multiple, phase-coherent holograms in the frequency domain each related to references located on suspect sound sources in an aircraft cabin. The analysis uses either SVD or Cholesky decomposition methods using ensemble averages of the cross-spectral density with the fixed references. The holograms are mathematically processed using spherical NAH (nearfield acoustical holography) to convert the measured pressure field into a vector intensity field in the volume of maximum radius 0.4 m centered on the sphere origin. The utility of this probe is evaluated in a detailed analysis of a recent in-flight experiment in cooperation with Boeing and NASA on NASA s Aries 757 aircraft. In this experiment the trim panels and insulation were removed over a section of the aircraft and the bare panels and windows were instrumented with accelerometers to use as references for the VAIM. Results show excellent success at locating and identifying the sources of interior noise in-flight in the frequency range of 0 to 1400 Hz. This work was supported by NASA and the Office of Naval Research.

Klos, Jacob↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets (invited)

A multi-chord fiber-coupled interferometer is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment. The long coherence length of the laser (>10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which both positive and negative phase shift values are observed depending on the ionization fraction. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx}15-50 km/s), jet length ({approx}20-100 cm), and 3D expansion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impacts of urbanization, antecedent rainfall event, and cyclone tracks on extreme floods at Houston reservoirs during Hurricane Harvey

The objective of this study is to evaluate the effects of urbanization, antecedent rainfall event (ARE), and varying cyclone tracks on the streamflow—and thus the subsequent reservoir status—during the floods caused by Hurricane Harvey in August-September 2017. Through a hydrological modeling approach, we examined how these factors influenced the inflows, peak pool elevations and outflows of the two most important detention reservoirs in the Houston region, the Addicks and Barker Reservoirs. A high-resolution rainfall reanalysis dataset for extreme storm events, along with a suite of synthetic rainfall values from a variety of storm tracks, were adopted to represent both the truth and the maximum possible rainfall during the Hurricane Harvey period. Results showed the following: Urbanization only led to slight increases in peak inflows, not necessarily leading to an increase in peak pool elevations. ARE contributed to the peak inflow and pool elevation slightly. In contrast, if the cyclone had followed the most adverse track consistent with earlier forecasts (all else being equal), the total volumetric flow into the two reservoirs could have been significantly larger (37.00% and 48.70% respectively), thus increasing the peak pool elevations by 1.06 and 1.37 meters respectively. These results suggest that large uncertainties exist for flood management at a watershed scale during hurricanes, because of the uncertainties with regard to the cyclone track. This is true even if storm-relative precipitation rates could be predicted perfectly.

54 ENVIRONMENTAL SCIENCES↗

FINAL TECHNICAL REPORT: Underwater Active Acoustic Monitoring Network For Marine And Hydrokinetic Energy Projects

This project saw the completion of the design and development of a second generation, high frequency (90-120 kHz) Subsurface-Threat Detection Sonar Network (SDSN). The system was deployed, operated, and tested in Cobscook Bay, Maine near the site the Ocean Renewable Power Company TidGen™ power unit. This effort resulted in a very successful demonstration of the SDSN detection, tracking, localization, and classification capabilities in a high current, MHK environment as measured by results from the detection and tracking trials in Cobscook Bay. The new high frequency node, designed to operate outside the hearing range of a subset of marine mammals, was shown to detect and track objects of marine mammal-like target strength to ranges of approximately 500 meters. This performance range results in the SDSN system tracking objects for a significant duration - on the order of minutes - even in a tidal flow of 5-7 knots, potentially allowing time for MHK system or operator decision-making if marine mammals are present. Having demonstrated detection and tracking of synthetic targets with target strengths similar to some marine mammals, the primary hurdle to eventual automated monitoring is a dataset of actual marine mammal kinematic behavior and modifying the tracking algorithms and parameters which are currently tuned to human diver kinematics and classification.

16 TIDAL AND WAVE POWER↗

Development of ultrasonic methods of hemodynamic measurements

A pulsed ultrasonic Doppler velocity meter which can be used (by modifying transducers) as a flowmeter for blood circulation was experimentally studied. Calculations and profiles of turbulent and laminar flow within blood vessels are shown. Graphs and charts of transducers are included.

Histand, M. B.↗

Applications of a laser velocimeter in the Langley 4- by 7-meter tunnel

Applications of a laser velocimeter in the Langley 4 by 7 meter wind tunnel are discussed. The system configuration is described. The data acquisition, the laser velocimeter traversing, and the particle generating systems are discussed. Flow distribution and rotor wake applications are discussed.

Sellers, W. L.↗