Search NASA⌕ Search

SEARCH · Search NASA

Results for “Forward sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Advanced Gas Turbine (AGT) powertrain system development for automotive applications

Rotor dynamic instability investigations were conducted. Forward ball bearing hydraulic mount configurations were tested with little effect. Trial assembly of S/N 002 ceramic engine was initiated. Impeller design activities were completed on the straight line element (SLE) blade definition to address near-net-shape powder metal die forging. Performance characteristics of the Baseline Test 2A impeller were closely preserved. The modified blading design has been released for tooling procurement. Developmental testing of the diffusion flame combustor (DFC) for initial use in the S/N 002 2100 F ceramic structures engine was completed. A natural gas slave preheater was designed and fabricated. Preliminary regenerator static seal rig testing showed a significant reduction in leakage and sensitivity to stack height. Ceramic screening tests were completed and two complete sets of ceramic static structures were qualified for engine testing. Efforts on rotor dynamics development to resolve subsynchronous motion were continued.

Source record↗

Inverse Solutions in Spectroscopic Analysis with Applications to Problems in Global Safeguards

This work describes a nondestructive strategy and algorithm designed to evaluate the burnup and plutonium content of light-water-reactor spent fuel and thereby confirm declared values. In contrast with previous methods that focus on only a few photopeaks (e.g., 137 Cs at 662 keV), the present approach involves the entire gamma spectrum up to 2000 keV. Spectra are used as input for the inverse code INDEPTH, which is designed to predict reactor parameters (fuel enrichment, power level, irradiation time, and cooling time) when given either a set of nuclide inventories or the gamma spectrum that they produce. This approach has the advantage of often making possible the determination of parameters other than burnup when they are unknown or in doubt. In addition, error in one photopeak evaluation is mitigated by the inclusion of the entire spectrum. The solution procedure involves multiple runs of the forward code ORIGEN/ARP, each of which produces an extensive list of nuclides formed through depletion/decay processes. The gamma spectrum of these nuclides is compared with the gamma spectrum from a detector through a bin-by-bin sum of squared error. New choices for the reactor parameters that are input to ORIGEN/ARP are determined using a gradient search technique, and the best parameter set is that which minimizes the squared error between calculated and measured gamma spectra. The method is applied to the analysis of gamma data taken from various sections of actual spent reactor fuel and is compared with declared values and other methods of evaluation. The sensitivity of the inverse solution with respect to various parameters is calculated and indicates that the algorithm is stable and robust. One example includes the presence of multiple solutions, each of which can be characterized using additional information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-E-17A-02: Predictive Modeling of Outcome Following SABR for NSCLC Based On Radiomics of FDG-PET Images

Purpose: This study aims to develop predictive models of patient outcome by extracting advanced imaging features (i.e., Radiomics) from FDG-PET images. Methods: We acquired pre-treatment PET scans for 51 stage I NSCLC patients treated with SABR. We calculated 139 quantitative features from each patient PET image, including 5 morphological features, 8 statistical features, 27 texture features, and 100 features from the intensity-volume histogram. Based on the imaging features, we aim to distinguish between 2 risk groups of patients: those with regional failure or distant metastasis versus those without. We investigated 3 pattern classification algorithms: linear discriminant analysis (LDA), naive Bayes (NB), and logistic regression (LR). To avoid the curse of dimensionality, we performed feature selection by first removing redundant features and then applying sequential forward selection using the wrapper approach. To evaluate the predictive performance, we performed 10-fold cross validation with 1000 random splits of the data and calculated the area under the ROC curve (AUC). Results: Feature selection identified 2 texture features (homogeneity and/or wavelet decompositions) for NB and LR, while for LDA SUVmax and one texture feature (correlation) were identified. All 3 classifiers achieved statistically significant improvements over conventional PET imaging metrics such as tumor volume (AUC = 0.668) and SUVmax (AUC = 0.737). Overall, NB achieved the best predictive performance (AUC = 0.806). This also compares favorably with MTV using the best threshold at an SUV of 11.6 (AUC = 0.746). At a sensitivity of 80%, NB achieved 69% specificity, while SUVmax and tumor volume only had 36% and 47% specificity. Conclusion: Through a systematic analysis of advanced PET imaging features, we are able to build models with improved predictive value over conventional imaging metrics. If validated in a large independent cohort, the proposed techniques could potentially aid in identifying patients who might benefit from adjuvant therapy.

60 APPLIED LIFE SCIENCES↗

Injection photodiodes based on low-resistivity ZnS single crystals

Results of an experimental study of Ni-n-n{sup +}-In photodiode structures fabricated from a low-resistivity ZnS:Al crystal (n{sup +}-region) are reported. The high-resistivity compensated n-type layer is produced by thermal diffusion of silver. The photodiodes exhibit an injection amplification of the photocurrent under a forward bias of 1-10 V. The dependence of the currents through the diodes on the thickness of the n-type layer in the dark and under UV irradiation is determined. The photosensitivity is at a maximum in the fundamental absorption range in a narrow spectral band.

36 MATERIALS SCIENCE↗

X-ray topography using the forward transmitted beam under multiple-beam diffraction conditions

X-ray topographs are taken for a sapphire wafer with the [0001] surface normal, as an example, by forward transmitted synchrotron x-ray beams combined with two-dimensional electronic arrays in the x-ray detector having a spatial resolution of 1 μm. They exhibit no shape deformation and no position shift of the dislocation lines on the topographs. Since the topography is performed under multiple-beam diffraction conditions, the topographic images of a single diffraction (two-wave approximation condition) or plural diffractions (six-wave approximation condition) can be recorded without large specimen position changes. As usual Lang topographs, it is possible to determine the Burgers vector of each dislocation line. Because of high parallelism of the incoming x-rays and linear sensitivity of the electronic arrays to the incident x-rays, the present technique can be used to visualize individual dislocations in single crystals of the dislocation density as high as 1 × 10{sup 5} cm{sup −2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗

ANALYSIS OF THE FORWARD-SCATTERING HANLE EFFECT IN THE Ca I 4227 A LINE

Coherent scattering of limb-darkened radiation is responsible for the generation of the linearly polarized spectrum of the Sun (the Second Solar Spectrum). This Second Solar Spectrum is usually observed near the limb of the Sun, where the polarization amplitudes are largest. At the center of the solar disk the linear polarization is zero for an axially symmetric atmosphere. Any mechanism that breaks the axial symmetry (like the presence of an oriented magnetic field, or resolved inhomogeneities in the atmosphere) can generate a non-zero linear polarization. In the present paper we study the linear polarization near the disk center in a weakly magnetized region, where the axisymmetry is broken. We present polarimetric (I, Q/I, U/I, and V/I) observations of the Ca I 4227 A line recorded around {mu} = cos {theta} = 0.9 (where {theta} is the heliocentric angle) and a modeling of these observations. The high sensitivity of the instrument (ZIMPOL-3) makes it possible to measure the weak polarimetric signals with great accuracy. The modeling of these high-quality observations requires the solution of the polarized radiative transfer equation in the presence of a magnetic field. For this we use standard one-dimensional model atmospheres. We show that the linear polarization is mainly produced by the Hanle effect (rather than by the transverse Zeeman effect), while the circular polarization is due to the longitudinal Zeeman effect. A unique determination of the full B vector may be achieved when both effects are accounted for. The field strengths required for the simultaneous fitting of Q/I, U/I, and V/I are in the range 10-50 G. The shapes and signs of the Q/I and U/I profiles are highly sensitive to the orientation of the magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Midplane neutral density profiles in the National Spherical Torus Experiment

Atomic and molecular density data in the outer midplane of NSTX [Ono et al., Nucl. Fusion 40, 557 (2000)] are inferred from tangential camera data via a forward modeling procedure using the DEGAS 2 Monte Carlo neutral transport code. The observed Balmer-b light emission data from 17 shots during the 2010 NSTX campaign display no obvious trends with discharge parameters such as the divertor Balmer-a emission level or edge deuterium ion density. Simulations of 12 time slices in 7 of these discharges produce molecular densities near the vacuum vessel wall of 2–8 x 10 17 m -3 and atomic densities ranging from 1 to 7 x 10 16 m -3 ; neither has a clear correlation with other parameters. Validation of the technique, begun in an earlier publication, is continued with an assessment of the sensitivity of the simulated camera image and neutral densities to uncertainties in the data input to the model. The simulated camera image is sensitive to the plasma profiles and virtually nothing else. The neutral densities at the vessel wall depend most strongly on the spatial distribution of the source; simulations with a localized neutral source yield densities within a factor of two of the baseline, uniform source, case. The uncertainties in the neutral densities associated with other model inputs and assumptions are ≤ 50%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Lighter-Than-Air System Enhanced with Kinetic Lift

A hybrid airship system is proposed in which the buoyant lift is enhanced with kinetic lift. The airship would consist of twin hulls in which the buoyant gas is contained. The twin hulls would be connected in parallel by a wing having an airfoil contour. In forward flight, the wing would provide kinetic lift that would add to the buoyant lift. The added lift would permit a greater payload/altitude combination than that which could be supported by the buoyant lift alone. The buoyant lift is a function of the volume of gas and the flight altitude. The kinetic lift is a function of the airfoil section, wing area, and the speed and altitude of flight. Accordingly there are a number of factors that can be manipulated to arrive at a particular design. Particular designs could vary from small, lightweight systems to very large, heavy-load systems. It will be the purpose of this paper to examine the sensitivity of such a design to the several variables. In addition, possible uses made achievable by such a hybrid system will be suggested.

Spearman, M. Leroy↗

Adaptive nonlocal means filtering based on local noise level for CT denoising

Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MnEdgeNet for accurate decomposition of mixed oxidation states for Mn XAS and EELS L2,3 edges without reference and calibration

Accurate decomposition of the mixed Mn oxidation states is highly important for characterizing the electronic structures, charge transfer and redox centers for electronic, and electrocatalytic and energy storage materials that contain Mn. Electron energy loss spectroscopy (EELS) and soft X-ray absorption spectroscopy (XAS) measurements of the Mn L2,3 edges are widely used for this purpose. To date, although the measurements of the Mn L2,3 edges are straightforward given the sample is prepared properly, an accurate decomposition of the mix valence states of Mn remains non-trivial. For both EELS and XAS, 2+, 3+, and 4+ reference spectra need to be taken on the same instrument/beamline and preferably in the same experimental session because the instrumental resolution and the energy axis offset could vary from one session to another. To circumvent this hurdle, in this study, we adopted a deep learning approach and developed a calibration-free and reference-free method to decompose the oxidation state of Mn L2,3 edges for both EELS and XAS. A deep learning regression model is trained to accurately predict the composition of the mix valence state of Mn. To synthesize physics-informed and ground-truth labeled training datasets, we created a forward model that takes into account plural scattering, instrumentation broadening, noise, and energy axis offset. With that, we created a 1.2 million-spectrum database with 1-by-3 oxidation state composition ground truth vectors. The library includes a sufficient variety of data including both EELS and XAS spectra. By training on this large database, our convolutional neural network achieves 85% accuracy on the validation dataset. We tested the model and found it is robust against noise (down to PSNR of 10) and plural scattering (up to t/λ = 1). We further validated the model against spectral data that were not used in training. In particular, the model shows high accuracy and high sensitivity for the decomposition of Mn 3 O 4 , MnO, Mn 2 O 3 , and MnO 2 . The accurate decomposition of Mn 3 O 4 experimental data shows the model is quantitatively correct and can be deployed for real experimental data. Our model will not only be a valuable tool to researchers and material scientists but also can assist experienced electron microscopists and synchrotron scientists in the automated analysis of Mn L edge data.

25 ENERGY STORAGE↗

Communication: Nucleation rates of supersaturated aqueous NaCl using a polarizable force field

In this work, we use molecular dynamics simulations with a polarizable force field, namely, the modified AH/BK3 model [J. Kolafa, J. Chem. Phys. 145, 204509 (2016)], in combination with the forward flux sampling technique, to calculate the rates of homogeneous nucleation of NaCl from supersaturated aqueous solutions at 298 K and 1 bar. A non-polarizable model that reproduces the experimental equilibrium solubility {AH/TIP4P-2005 of Benavides et al. [J. Chem. Phys. 147, 104501 (2017)]} is also used for comparison. Nucleation rates calculated from the polarizable force field are found to be in good agreement with experimental measurements, while the non-polarizable model severely underestimates the nucleation rates. These results, in combination with our earlier study of a different non-polarizable force field [H. Jiang et al., J. Chem. Phys. 148, 044505 (2018)], lead to the conclusion that nucleation rates are sensitive to the details of force fields, and a good representation of nucleation rates may not be feasible using available non-polarizable force fields, even if these reproduce the equilibrium salt solubility. Finally, inclusion of polarization could be important for an accurate prediction of nucleation rates in salt solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of the BDX experiment for Light Dark Matter searches at JLab

The Light Dark Matter (LDM) hypothesis postulates the existence of a new class of sub GeV particles, neutral under Standard Model (SM) interactions. In its simplest form, LDM consists of particles ¿ with masses below 1 GeV/c2, interacting with SM particles via a new force mediated by a light, spin-1 boson A0, commonly referred to as “Dark Photon”. This framework envisions a distinct “Dark Sector” with its own particles and interactions, offering a theoretically well motivated explanation for Dark Matter, consistent with astrophysical observations and a thermal production mechanism. The Beam Dump eXperiment (BDX) is an approved experiment at Jefferson Lab designed to search for Light Dark Matter. BDX will utilize an 11 GeV electron beam impinging on a thick target to produce a forward-boosted secondary beam of Light Dark Matter particles, which will then be detected by a dedicated downstream detector. Approved in 2018, BDX is expected to be commissioned in 2026 and run in 2027-2029. My thesis focuses on the preparatory work to deploy the BDX experiment. The detector design has been optimized to balance practicality with enhanced Light Dark Matter detection capabilities. Extensive characterization of detector components has been performed to ensure a precise understanding of detector response. A custom Monte Carlo framework has been developed to simulate Light Dark Matter signal and explore various theoretical models of interest. Additionally, a comprehensive data analysis framework has been developed to maximize the experiment sensitivity to Light Dark Matter, with optimizations based on expected detector performance. The ultimate goal of this thesis is to optimize BDX as a flagship experiment in Light Dark Matter searches, enabling it to probe different Dark Matter models.

Spreafico, M. [Univ. of Genova (Italy)]↗

Sensitivity of MODIS 2.1-(micrometers) Channel for Off-Nadir View Angles for Use in Remote Sensing of Aerosol

In this sensitivity study, we examined the ratio technique, the official method for remote sensing of aerosols over land from Moderate Resolution Imaging Spectroradiometer (MODIS) DATA, for view angles from nadir to 65 deg. off-nadir using Cloud Absorption Radiometer (CAR) data collected during the Smoke, Clouds, and Radiation-Brazil (SCAR-B) experiment conducted in 1995. For the data analyzed and for the view angles tested, results seem to suggest that the reflectance (rho)0.47 and (rho)0.67 are predictable from (rho)2.1 using: (rho)0.47 = (rho)2.1/6, which is a slight modification and (rho)0.67 = (rho)2.1/2. These results hold for target viewed from backscattered direction, but not for the forward direction.

Gatebe, C. K.↗

ACCURATE CHARACTERIZATION OF HIGH-DEGREE MODES USING MDI OBSERVATIONS

We present the first accurate characterization of high-degree modes, derived using the best Michelson Doppler Imager (MDI) full-disk full-resolution data set available. A 90 day long time series of full-disk 2 arcsec pixel{sup -1} resolution Dopplergrams was acquired in 2001, thanks to the high rate telemetry provided by the Deep Space Network. These Dopplergrams were spatially decomposed using our best estimate of the image scale and the known components of MDI's image distortion. A multi-taper power spectrum estimator was used to generate power spectra for all degrees and all azimuthal orders, up to l = 1000. We used a large number of tapers to reduce the realization noise, since at high degrees the individual modes blend into ridges and thus there is no reason to preserve a high spectral resolution. These power spectra were fitted for all degrees and all azimuthal orders, between l = 100 and l = 1000, and for all the orders with substantial amplitude. This fitting generated in excess of 5.2 Multiplication-Sign 10{sup 6} individual estimates of ridge frequencies, line widths, amplitudes, and asymmetries (singlets), corresponding to some 5700 multiplets (l, n). Fitting at high degrees generates ridge characteristics, characteristics that do not correspond to the underlying mode characteristics. We used a sophisticated forward modeling to recover the best possible estimate of the underlying mode characteristics (mode frequencies, as well as line widths, amplitudes, and asymmetries). We describe in detail this modeling and its validation. The modeling has been extensively reviewed and refined, by including an iterative process to improve its input parameters to better match the observations. Also, the contribution of the leakage matrix on the accuracy of the procedure has been carefully assessed. We present the derived set of corrected mode characteristics, which includes not only frequencies, but line widths, asymmetries, and amplitudes. We present and discuss their uncertainties and the precision of the ridge-to-mode correction schemes, through a detailed assessment of the sensitivity of the model to its input set. The precision of the ridge-to-mode correction is indicative of any possible residual systematic biases in the inferred mode characteristics. In our conclusions, we address how to further improve these estimates, and the implications for other data sets, like GONG+ and HMI.

79 ASTRONOMY AND ASTROPHYSICS↗

Additive Manufacturing of Advanced High Temperature Masking Fixtures for EBPVD TBC Coating

The purpose of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Praxair Surface Technologies, Inc. (PST) and Oak Ridge National Laboratory (ORNL) was to develop an additive manufacturing process to fabricate next generation high temperature masking fixtures for coating of turbine airfoils with ceramic Thermal Barrier Coatings (TBC) by the Electron Beam Physical Vapor Deposition (EBPVD) process. Typical masking fixtures are sophisticated designs and require complex part manipulation in order to achieve the desired coating distribution. Fixtures are typically fabricated from high temperature nickel (Ni) based superalloys. The fixtures are fabricated from conventional processes by welding of thin sheet material into a complex geometry, to decrease the weight load for the manipulator and to reduce the thermal mass of the fixture. Recent attempts have been made in order to fabricate the fixtures through casting, but thin walled sections are difficult to cast and have high scrap rates. This project focused on understanding the potential for fabricating high temperature Ni based superalloy fixtures through additive manufacturing. Two different deposition processes; electron beam melting (EBM) and laser powder bed fusion were evaluated to determine the ideal processing route of these materials. Two different high temperature materials were evaluated. The high temperature materials evaluated were Inconel 718 and another Ni base alloy, designated throughout the remainder of this document as Alloy X, as the alloy composition is sensitive. Inconel 718 is a more widely utilized material for additive manufacturing although it is not currently the material utilized for current fixtures. Alloy X is the alloy currently used for the fixtures, but is not a commercially available alloy for additive manufacturing. Praxair determined it was possible to build the fixture using laser powder bed technology from Inconel 718. ORNL fabricated the fixture geometry using the EBM technology in order to compare deposition features such as surface roughness, geometric accuracy, deposition rate, surface and subsurface porosity, and material quality. It was determined that the laser powder bed technology was ideal for the geometry and requirements of the fixture set by Praxair, and Praxair moved forward with the purchase of a laser powder bed system. The subsequent portion of the project focused on determining the ideal processing parameters for alloy X for the laser powder bed system using ORNL’s Renishaw laser powder bed system. Praxair supplied gas atomized powders of alloy X material with properties specified by ORNL. ORNL printed text cube arrays in order to determine the ideal combination of laser powder and laser travel speed in order to maximize material density, improve surface quality, and maintain geometric accuracy. Additional powder supplied by Praxair was used to fabricate a full-scale fixture component.

42 ENGINEERING↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Scientific/Technical Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 µm or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

20KV↗