Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Ptychography at the Linac Coherent Light Source in a parasitic geometry

X-ray free-electron lasers (FELs) are being recognized as a powerful tool in an ever-increasing number of research fields, but are very limited as to the number of experiments that they can support. This work shows that more beamtime could be made available by using `parasitic' geometries, where a secondary experiment uses the X-ray beam that the primary experiment does not utilize. The first successful ptychography experiment, a scanning coherent diffractive imaging technique, in a parasitic geometry at an X-ray FEL is demonstrated. Utilizing the CXI hutch at the Linac Coherent Light Source (LCLS), it is shown that the obtained data are of high quality and that characterizing the beam using ptychography can be much faster than traditional imprinting methods.

42 ENGINEERING↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

In situ electrochemical high-energy X-ray diffraction using a capillary working electrode cell geometry

The ability to generate new electrochemically active materials for energy generation and storage with improved properties will likely be derived from an understanding of atomic-scale structure/function relationships during electrochemical events. Here, the design and implementation of a new capillary electrochemical cell designed specifically for in situ high-energy X-ray diffraction measurements is described. By increasing the amount of electrochemically active material in the X-ray path while implementing low- Z cell materials with anisotropic scattering profiles, an order of magnitude enhancement in diffracted X-ray signal over traditional cell geometries for multiple electrochemically active materials is demonstrated. This signal improvement is crucial for high-energy X-ray diffraction measurements and subsequent Fourier transformation into atomic pair distribution functions for atomic-scale structural analysis. As an example, clear structural changes in LiCoO 2 under reductive and oxidative conditions using the capillary cell are demonstrated, which agree with prior studies. Accurate modeling of the LiCoO 2 diffraction data using reverse Monte Carlo simulations further verifies accurate background subtraction and strong signal from the electrochemically active material, enabled by the capillary working electrode geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of collimator geometries for imaging mixed radiation fields with fast liquid organic scintillators

As a result of recent advances in digital pulse-shape discrimination methods it has become possible to image mixed fields (radiation environments compromising both neutrons and gamma rays) relatively quickly with a single, organic liquid 'fast' scintillator within a heavy metal collimator. The use of a liquid scintillator has significant benefits over other techniques for imaging radiation environments as the acquired data can be analysed to provide separate information about the gamma and neutron emissions from a source (or sources) in a single scan. The imaging resolution achieved is fundamentally related to the detector efficiency and to the collimator geometry. In this paper the impact of using two different geometries of tungsten collimator are compared experimentally and three different materials considered in the Monte Carlo simulation, in order to determine the optimum set-up for mixed-field imaging. The measurements were performed in the low-scatter facility of the National Physical Laboratory, Teddington. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inductor Geometry With Improved Energy Density

The "constant-flux" concept is leveraged to achieve high magnetic-energy density, leading to inductor geometries with height significantly lower than that of conventional products. Techniques to shape the core and to distribute the winding turns to shape a desirable field profile are described for the two basic classes of magnetic geometries: those with the winding enclosed by the core and those with the core enclosed by the winding. A relatively constant flux distribution is advantageous not only from the density standpoint, but also from the thermal standpoint via the reduction of hot spots, and from the reliability standpoint via the suppression of flux crowding. In this journal paper on a constant-flux inductor (CFI) with enclosed winding, the foci are operating principle, dc analysis, and basic design procedure. Prototype cores and windings were routed from powder-iron disks and copper sheets, respectively. The design of CFI was validated by the assembled inductor prototype.

Cui, H↗

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE↗

Performance Modeling of a Variable-Geometry Oscillating Surge Wave Energy Converter on a Raised Foundation

This paper analyzes the power capture potential, structural loadings, and costs associated with an oscillating surge wave energy converter (OSWEC) operating on a raised foundation. The raised OSWEC offers opportunities for reduced installation costs, improved energy production, and greater flexibility of deployment when compared with fixed-bottom models. In this investigation, we simulated several different foundation geometries using WEC-Sim to estimate power capture and structural loads. In an effort to maximize power capture, several cases in which flat plates of varying size were attached to the top of the foundation, under and parallel with the OSWEC, were also simulated. These plates were found to enhance power capture by preventing the wave-induced pressure from passing underneath the OSWEC, diverting this pressure toward the OSWEC instead. The OSWEC was simulated in the six Wave Energy Prize sea states, which were chosen as a representative sample of U.S. deployment sites. A first-order estimate of structural costs was calculated using the Wave Energy Prize ACE metric, with the foundation comprised predominantly of steel-reinforced concrete and the OSWEC comprised of A36 steel. Influence of foundation geometry on power capture, structural loadings, and ACE are topics of particular interest. This work has been inspired by advances in large-scale additive manufacturing techniques that have the potential to dramatically reduce the cost of subsea foundations. These advancements may enable cost-effective WEC systems to be deployed on raised foundations.

cost↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. The deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Because opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. The load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. The comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational power take-off damping about the hinge axis. Changing the rotational power take-off damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

Development of high-vacuum planar magnetron sputtering using an advanced magnetic field geometry

A permanent magnet in a new magnetic field geometry (namely, with the magnetization in the radial direction) was fabricated and used for high-vacuum planar magnetron sputtering using Penning discharge. Because of the development of this magnet, the discharge current and deposition rate were increased two to three times in comparison with the values attainable with a magnet in the conventional geometry. This improvement was because the available space for effective discharge of the energetic electrons for the ionization increased because the magnetic field distribution increased in both the axial and radial directions of discharge.

42 ENGINEERING↗

Modeling blur in various detector geometries for MeV radiography

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for applications in MeV radiography. Segmented scintillating detectors, where low Z scintillators combined with a high-Z metal matrix, can be designed in which the resolution increases with increasing metal fraction. Here, the combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution. Select detector geometries were tested by comparing simulation and experimental modulation transfer functions to validate the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing software upgrades, plan properties and patient geometry using intensity modulated radiation therapy (IMRT) complexity metrics

Purpose: The aim of this study is to compare the sensitivity of different metrics to detect differences in complexity of intensity modulated radiation therapy (IMRT) plans following upgrades, changes to planning parameters, and patient geometry. Correlations between complexity metrics are also assessed. Method: A program was developed to calculate a series of metrics used to describe the complexity of IMRT fields using monitor units (MUs) and multileaf collimator files: Modulation index (MI), modulation complexity score (MCS), and plan intensity map variation (PIMV). Each metric, including the MUs, was used to assess changes in beam complexity for six prostate patients, following upgrades in the inverse planning optimization software designed to incorporate direct aperture optimization (DAO). All beams were delivered to a 2D ionization chamber array and compared to those calculated using gamma analysis. Each complexity metric was then calculated for all beams, on a different set of six prostate IMRT patients, to assess differences between plans calculated using different minimum field sizes and different maximum segment numbers. Different geometries, including CShape, prostate, and head and neck phantoms, were also assessed using the metrics. Correlations between complexity metrics were calculated for 20 prostate IMRT patients. Results: MU, MCS, MI, and PIMV could all detect reduced complexity following an upgrade to the optimization leaf sequencer, although only MI and MCS could detect a reduction in complexity when one-step optimization (DAO) was employed rather than two-step optimization. All metrics detected a reduction in complexity when the minimum field size was increased from 1 to 4 cm and all apart from PIMV detected reduced complexity when the number of segments was significantly reduced. All metrics apart from MI showed differences in complexity depending on the treatment site. Significant correlations exist between all metrics apart from MI and PIMV for prostate IMRT patients. Treatment deliverability appeared to be more correlated with MI and MCS than MU or PIMV. Conclusions: The application of complexity metrics in the IMRT treatment planning process has been demonstrated. Complexity of treatment plans can vary for different inverse planning software versions and can depend on planning parameters and the treatment site. MCS is most suitable for inclusion within the cost function to limit complexity in IMRT optimization due to its sensitivity to complexity changes and correlation to treatment deliverability.

60 APPLIED LIFE SCIENCES↗

An empirical model of diagnostic x-ray attenuation under narrow-beam geometry

Purpose: The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. Methods: An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semilogarithmic (exponential) and linear interpolation]. Results: The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R{sup 2} > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. Conclusions: The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries - application to far-from-axis fields

Purpose: Two new codes, PENEASY and PENEASYLINAC, which automate the Monte Carlo simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their electron applicators and multileaf collimators, are introduced. The challenging case of a relatively small and far-from-axis field has been studied with these tools. Methods: PENEASY is a modular, general-purpose main program for the PENELOPE Monte Carlo system that includes various source models, tallies and variance-reduction techniques (VRT). The code includes a new geometry model that allows the superposition of voxels and objects limited by quadric surfaces. A variant of the VRT known as particle splitting, called fan splitting, is also introduced. PENEASYLINAC, in turn, automatically generates detailed geometry and configuration files to simulate linacs with PENEASY. These tools are applied to the generation of phase-space files, and of the corresponding absorbed dose distributions in water, for two 6 MV photon beams from a Varian Clinac 2100 C/D: a 40 x 40 cm{sup 2} centered field; and a 3 x 5 cm{sup 2} field centered at (4.5, -11.5) cm from the beam central axis. This latter configuration implies the largest possible over-traveling values of two of the jaws. Simulation results for the depth dose and lateral profiles at various depths are compared, by using the gamma index, with experimental values obtained with a PTW 31002 ionization chamber. The contribution of several VRTs to the computing speed of the more demanding off-axis case is analyzed. Results: For the 40 x 40 cm{sup 2} field, the percentages {gamma}{sub 1} and {gamma}{sub 1.2} of voxels with gamma indices (using 0.2 cm and 2% criteria) larger than unity and larger than 1.2 are 0.2% and 0%, respectively. For the 3 x 5 cm{sup 2} field, {gamma}{sub 1} = 0%. These figures indicate an excellent agreement between simulation and experiment. The dose distribution for the off-axis case with voxels of 2.5 x 2.5 x 2.5 mm{sup 3} and an average standard statistical uncertainty of 2% (1{sigma}) is computed in 3.1 h on a single core of a 2.8 GHz Intel Core 2 Duo processor. This result is obtained with the optimal combination of the tested VRTs. In particular, fan splitting for the off-axis case accelerates execution by a factor of 240 with respect to standard particle splitting. Conclusions: PENEASY and PENEASYLINAC can simulate the considered Varian Clinacs both in an accurate and efficient manner. Fan splitting is crucial to achieve simulation results for the off-axis field in an affordable amount of CPU time. Work to include Elekta linacs and to develop a graphical interface that will facilitate user input is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries

Purpose: Pencil beam algorithms are commonly used for proton therapy dose calculations. Szymanowski and Oelfke ['Two-dimensional pencil beam scaling: An improved proton dose algorithm for heterogeneous media,' Phys. Med. Biol. 47, 3313-3330 (2002)] developed a two-dimensional (2D) scaling algorithm which accurately models the radial pencil beam width as a function of depth in heterogeneous slab geometries using a scaled expression for the radial kernel width in water as a function of depth and kinetic energy. However, an assumption made in the derivation of the technique limits its range of validity to cases where the input expression for the radial kernel width in water is derived from a local scattering power model. The goal of this work is to derive a generalized form of 2D pencil beam scaling that is independent of the scattering power model and appropriate for use with any expression for the radial kernel width in water as a function of depth. Methods: Using Fermi-Eyges transport theory, the authors derive an expression for the radial pencil beam width in heterogeneous slab geometries which is independent of the proton scattering power and related quantities. The authors then perform test calculations in homogeneous and heterogeneous slab phantoms using both the original 2D scaling model and the new model with expressions for the radial kernel width in water computed from both local and nonlocal scattering power models, as well as a nonlocal parameterization of Moliere scattering theory. In addition to kernel width calculations, dose calculations are also performed for a narrow Gaussian proton beam. Results: Pencil beam width calculations indicate that both 2D scaling formalisms perform well when the radial kernel width in water is derived from a local scattering power model. Computing the radial kernel width from a nonlocal scattering model results in the local 2D scaling formula under-predicting the pencil beam width by as much as 1.4 mm (21%) at the depth of the Bragg peak for a 220 MeV proton beam in homogeneous water. This translates into a 32% dose discrepancy for a 5 mm Gaussian proton beam. Similar trends were observed for calculations made in heterogeneous slab phantoms where it was also noted that errors tend to increase with greater beam penetration. The generalized 2D scaling model performs well in all situations, with a maximum dose error of 0.3% at the Bragg peak in a heterogeneous phantom containing 3 cm of hard bone. Conclusions: The authors have derived a generalized form of 2D pencil beam scaling which is independent of the proton scattering power model and robust to the functional form of the radial kernel width in water used for the calculations. Sample calculations made with this model show excellent agreement with expected values in both homogeneous water and heterogeneous phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-12: Flexible Geometry Computed Tomography

Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable tradeoff of producing meaningful image-quality verses the practicality of how to obtain sufficient image data.

60 APPLIED LIFE SCIENCES↗

Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on real-time implementation and application-specific analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗