At least 829 records · Page 46

The effectiveness of D 2 pellet and gas injection in reducing intra-ELM tungsten erosion and heat flux in the DIII-D small angle slot divertor

Edge localized modes (ELMs) in H-mode plasmas can melt and erode plasma-facing components (PFCs) and lead to impurities in the core, reducing confinement. This study analyzes the use of D 2 pellet and gas injection for ELM mitigation on the DIII-D tokamak during the 2022 Small Angle Slot V-shaped Tungsten (W) (SAS-VW) divertor campaign, reducing W erosion and heat flux during ELMs. D α (656 nm) and WI (400.9 nm) filterscopes and Langmuir probes provide photon emission and electron density/temperature to estimate W atom erosion using the S/XB method, while surface eroding thermocouples measured ELM peak heat flux at the outer strike point (OSP). Thomson Scattering measurements of pedestal T e and n e provided input to predict W divertor erosion and heat flux during ELMs via the Free-Streaming plus Recycling Model (FSRM). While a greater D 2 mass injection rate decreased the ELM peak heat flux, the impact on W erosion was not monotonic. The average ‘large’ intra-ELM W erosion was lower for plasma shots with D 2 mass injection compared to the plasma shots without any D 2 mass injection in the SAS-VW divertor. However, plasma shots did not see significant changes in ‘large’ intra-ELM W divertor erosion as the D 2 mass injection rate increased. On average, the FSRM overestimated SAS-VW experimental intra-ELM W erosion by a factor of 6.9, but the overestimation is reduced to a factor of 3.6 with the implication of C deposition effects. Generally, experimentally measured and predicted quantities were worse for plasma shots with a lower D 2 mass injection rate and corresponding higher plasma carbon (C) impurity percentage (f C ). The discrepancies are postulated to be due to C/W material mixing, for which a simple analytic mixed-material model is presented. These results highlight the importance of incorporating and improving the robustness of a mixed-material layer model in the analysis of PFC erosion on present and future tokamak devices.

Carbon (C)↗

Dynamics of heat-pipe reactors.

A split-core heat-pipe reactor fueled with either 233-UC or 235-UC in a tungsten cermet and cooled by 7-Li-W heat pipes is examined for the effects of the heat pipes on this reactor in trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel-melting temperature and heat-pipe wall heat flux are mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗

Validation of a Thermo-Ablative Model of Elastomeric Internal Insulation Materials

In thermo-ablative material modeling, as in many fields of analysis, the quality of the existing models significantly exceeds that of the experimental data required for their validation. In an effort to narrow this gap, a laboratory-scale internal insulation test bed was developed that exposes insulation samples to realistic solid rocket motor (SRM) internal environments while being instrumented to record real-time rates of both model inputs (i.e., chamber pressure, total surface heat flux, and radiative heat flux) as well as model outputs (i.e., material decomposition depths (MDDs) and in-depth material temperatures). In this work, the measured SRM internal environment parameters were used in conjunction with equilibrium thermochemistry codes as inputs to one-dimensional thermo-ablative models of the PBINBR and CFEPDM insulation samples used in the lab-scale test firings. The computed MDD histories were then compared with those deduced from real-time X-ray radiography of the insulation samples, and the calculated in-depth temperatures were compared with those measured by embedded thermocouples. The results of this exercise emphasize the challenges of modeling and testing elastomeric materials in SRM environments while illuminating the path forward to improved fidelity.

Martin, Heath T.↗

Heating system with induction power supply and electromagnetic acoustic transducer with induction power supply

A system for heating a fluid and an electromagnetic acoustic transducer EMAT system is provided. Both systems have a drive circuit. The amount of heat and the amplitude (and acceleration) of the vibrations is respectively controllable by controlling an input to a terminal of a switch. The heating system comprises a porous graphite foam conductor which is exposed to an electromagnetic field generated by an oscillating circuit. When exposed, the foam conductor conducts induced electric current which heats the same and a fluid in contact with the conductor. The EMAT system comprises at least one magnet configured to generate a static magnetic field, an oscillating circuit and a working element. The working element, when exposed to the static magnetic field and the electromagnetic field produced by the oscillating circuit, vibrates against a load. The vibrations dry the load.

Kisner, Roger A.↗

Heat dissipation in water-cooled reflectors

The energy balance of a lamp varies with the thermal and optical characteristics of the reflector. The photosynthetic radiation efficiency of lamps, defined as input power divided by photosynthetically active radiation (PAR, 400-700 nm) emitted from the lamp ranges between 0.17 and 0.26. The rest of the energy input is wasted as longwave (3000 nm and over) and non-PAR shortwave radiation (from 700 nm to 3000 nm), convective, and conductive heat from the lamp, reflector, and ballast, and simply for increasing the cooling load. Furthermore, some portion of the PAR is uselessly absorbed by the inner walls, shelves, vessels, etc. and some portion of the PAR received by the plantlets is converted into sensible and latent heat. More than 98% of the energy input is probably converted into heat, with only less than 2% of the energy input being converted into chemical energy as carbohydrates by photosynthesis. Therefore, it is essential to reduce the generation of heat in the culture room in order to reduce the cooling load. Through use of a water-cooled reflector, the generation of convective and conductive heat and longwave radiation from the reflector can be reduced, without reduction of PAR.

Kozai, Toyoki↗

Water-cooled Reactor Cavity Cooling System Flow Analysis

A research team at University of Wisconsin - Madison designed and constructed a 1/4 scaled experimental facility to study natural circulation cooling in a water based reactor cavity cooling system (WRCCS) for decay heat removal in an advanced high temperature reactor. The facility is capable of natural circulation operation scaled for simulated decay heat removal (up to 45 kW input power, which is equivalent to 1.70 MW at full scale) and pressurized up to 2 bar pressure. The WRCCS facility has been used to study natural circulation flow behavior from transients due to evaporation of the water inventory from decay heat removal. The natural circulation flow is observed to be oscillatory with the mean flow increasing as the pressure head in the system drops due to evaporation of the water inventory during two-phase operation. A first principles model was developed to understand the behavioral limits and trends. Through the use of void fraction measurements and the model, we find that the mass flow rate in the system increases due to small increases in the time-averaged void fraction over the course of a four-hour boil-off experiment. This increase in void fraction causes an increase in the buoyancy head and mass flow. The model also determines the operational limits on the mass flow rate under two-phase operation that can be verified with extended tests in the WRCCS facility. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Rotary engine performance computer program (RCEMAP and RCEMAPPC): User's guide

This report is a user's guide for a computer code that simulates the performance of several rotary combustion engine configurations. It is intended to assist prospective users in getting started with RCEMAP and/or RCEMAPPC. RCEMAP (Rotary Combustion Engine performance MAP generating code) is the mainframe version, while RCEMAPPC is a simplified subset designed for the personal computer, or PC, environment. Both versions are based on an open, zero-dimensional combustion system model for the prediction of instantaneous pressures, temperature, chemical composition and other in-chamber thermodynamic properties. Both versions predict overall engine performance and thermal characteristics, including bmep, bsfc, exhaust gas temperature, average material temperatures, and turbocharger operating conditions. Required inputs include engine geometry, materials, constants for use in the combustion heat release model, and turbomachinery maps. Illustrative examples and sample input files for both versions are included.

Bartrand, Timothy A.↗

Investigation of the transport shortfall in Alcator C-Mod L-mode plasmas

A so-called 'transport shortfall,' where ion and electron heat fluxes and turbulence are underpredicted by gyrokinetic codes, has been robustly identified in DIII-D L-mode plasmas for {rho}>0.55[T. L. Rhodes et al., Nucl. Fusion 51(6), 063022 (2011); and C. Holland et al., Phys. Plasmas 16(5), 052301 (2009)]. To probe the existence of a transport shortfall across different tokamaks, a dedicated scan of auxiliary heated L-mode discharges in Alcator C-Mod are studied in detail with nonlinear gyrokinetic simulations for the first time. Two discharges, only differing by the amount of auxiliary heating are investigated using both linear and nonlinear simulation of the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)]. Nonlinear gyrokinetic simulation of the low and high input power discharges reveals a discrepancy between simulation and experiment in only the electron heat flux channel of the low input power discharge. However, both discharges demonstrate excellent agreement in the ion heat flux channel, and the high input power discharge demonstrates simultaneous agreement with experiment in both the electron and ion heat flux channels. A summary of linear and nonlinear gyrokinetic results and a discussion of possible explanations for the agreement/disagreement in each heat flux channel is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poloidally and radially resolved parallel D{sup +} velocity measurements in the DIII-D boundary and comparison to neoclassical computations

First measurements of the D{sup +} parallel velocity, V{sub ||}{sup D+}, in L-mode discharges in the DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] tokamak boundary region at two poloidal locations, {theta}{approx}0 deg. and {theta}{approx}255 deg., made using Mach probes, feature a peak with velocities of up to 80 km/s at the midplane last closed flux surface (LCFS), as high as ten times the charge exchange recombination C{sup 6+} toroidal velocity, V{sub {phi}}{sup C6+}, in the same location. The V{sub ||}{sup D+} profiles are very asymmetric poloidally, by a factor of 8-10, and feature a local peak at the midplane. This peak, 1-2 cm wide, is located at or just inside the LCFS, and it suggests a large source of momentum in that location. This momentum source is quantified at {approx}0.31 N m by using a simple momentum transport model. This is the most accurate measurement of the effects of so called 'intrinsic' edge momentum source to date. The V{sub ||}{sup D+} measurements are quantitatively consistent with a purely neoclassical computational modeling of V{sub ||}{sup D+} by the code NEO[E. A. Belli and J. Candy, Plasma Phys. Controlled Fusion 50, 095010 (2008)], using V{sub {phi}}{sup C6+} as input, for {rho}{approx}0.7-0.95 at the two poloidal locations, where V{sub ||}{sup D+} measurements exist. The midplane NEO-calculated V{sub ||}{sup D+} grows larger than V{sub ||}{sup C6+} in the steeper edge gradient region and trends to agreement with the probe-measured V{sub ||}{sup D+} data near {rho}{approx}1, where the local V{sub ||}{sup D+} velocity peak exists. The measurements and computations were made in OH and L-mode discharges on an upper single null, with ion {nabla}B{sub T} drift away from the divertor. The rotating layer finding is similar in auxiliary heated discharges with and without external momentum input, except that at higher density the edge velocity weakens.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Heat Exchangers

The objective of this research is to develop tools to design and optimize heat exchangers (HE) and compact heat exchangers (CHE) for intermediate loop heat transport systems found in the very high temperature reator (VHTR) and other Generation IV designs by addressing heat transfer surface augmentation and conjugate modeling. To optimize heat exchanger, a fast running model must be created that will allow for multiple designs to be compared quickly. To model a heat exchanger, volume averaging theory, VAT, is used. VAT allows for the conservation of mass, momentum and energy to be solved for point by point in a 3 dimensional computer model of a heat exchanger. The end product of this project is a computer code that can predict an optimal configuration for a heat exchanger given only a few constraints (input fluids, size, cost, etc.). As VAT computer code can be used to model characteristics )pumping power, temperatures, and cost) of heat exchangers more quickly than traditional CFD or experiment, optimization of every geometric parameter simultaneously can be made. Using design of experiment, DOE and genetric algorithms, GE, to optimize the results of the computer code will improve heat exchanger disign.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rich n-heptane and diesel combustion in porous media

Rich n-heptane and diesel flames in two-layer porous media are experimentally investigated in the context of syngas production. The stable operating points of n-heptane reforming have been determined and the mole fractions of H{sub 2}, CO, CO{sub 2} and light hydrocarbons have been measured in the exhaust gas at an equivalence ratio of 2 for different thermal input values. The reformer performance has been assessed also from the point of view of the heat losses and the mixture homogeneity. The pre-vapouriser produces an approximately uniform vapour-air mixture upstream of the flame front. The range of flow rates for stable flames decreased with increasing equivalence ratio. Heat losses were about 10% of the thermal input at high firing rates. A 77.2% of the equilibrium H{sub 2} was achieved at a flame speed of 0.82 m/s. The same reactor with a different porous matrix for the reforming stage demonstrates diesel reforming to syngas with a conversion efficiency of 77.3% for a flame speed of 0.65 m/s. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient performance of MED processes with different feed configurations

Four different configurations of Multi-Effect-Desalination (MED): backward feed (BF), forward feed (FF), parallel feed (PF) and parallel/cross feed (PCF) are modeled in steady and dynamic operation to examine the behavior of these configurations under transient operation. Adding thermal vapor compressor (TVC) unit with the last effect of parallel/cross configuration is also studied and compared to the other configurations to show the advantage of this type of integration. The transient operation is achieved by applying ramp changes (disturbances) in the main input parameters that include steam flow rate at the heat source and cooling seawater temperature and flow rate at the heat sink. Steady state results indicate that parallel/cross feed has a relatively better performance characteristic than the other feed configurations regarding Gain Output Ratio (GOR) and specific heat consumption (SHC). Adding TVC unit to the parallel/cross feed achieves the lowest water production cost. Dynamic results show that MED-TVC with parallel/cross feed has the fastest response while backward feed and forward feed have the slower response to the applied disturbances. In the case of heat source disturbance, MED plants operating in the backward feed arrangement may be exposed to shut down due to the significant increase in brine level for the first effect. The MED-TVC process is susceptible to the heat sink disturbances compared to the PCF and other configurations. Also, changes in input parameters lead to the highest reduction in GOR for the MED-TVC process compared to the different configurations, especially for cooling seawater temperature. The highest reduction in brine level occurs in MED-TVC for a disturbance in the cooling seawater flow rate and may lead to MED-TVC evaporator drying condition. Hence, MED-TVC will require a reliable control system to avoid this type of plant operational disturbance.

42 ENGINEERING↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

EXTREME-ULTRAVIOLET OBSERVATIONAL CONSEQUENCES OF THE SPATIAL LOCALIZATION OF NANOFLARE HEATING WITHIN A MULTISTRANDED ATMOSPHERIC LOOP

Determining the preferred spatial location of the energy input to solar coronal loops would be an important step forward toward a more complete understanding of the coronal heating problem. Following from the 2008 paper of Sarkar and Walsh, this paper presents a short (10{sup 9} cm {identical_to}10 Mm) 'global loop' as 125 individual strands, where each strand is modeled independently by a one-dimensional hydrodynamic simulation. The strands undergo small-scale episodic heating and are coupled together through the frequency distribution of the total energy input to the loop which follows a power-law distribution with index {approx}2.29. The spatial preference of the swarm of heating events from apex to footpoint is investigated. From a theoretical perspective, the resulting emission-measure-weighted temperature profiles along these two extreme cases do demonstrate a possible observable difference. Subsequently, the simulated output is folded through the Transition Region and Coronal Explorer (TRACE) instrument response functions and a rederivation of the temperature using different filter ratio techniques is performed. Given the multithermal scenario created by this many-strand loop model, a broad differential emission measure results; the subsequent double and triple filter ratios are very similar to those obtained from observations. However, any potential observational signature to differentiate between apex and footpoint dominant heating is possibly below instrumental thresholds. The consequences of using a broadband instrument like TRACE and Hinode-XRT in this way are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techno-economic analysis of renewable energy source options for a district heating project

With the increased interest in exploiting renewable energy sources for district heating applications, the economic comparison of viable options has been considered as an important step in making a sound decision. In this paper, the economic performance of several energy options for a district heating system in Vancouver, British Columbia, is studied. The considered district heating system includes a 10 MW peaking/ backup natural gas boiler to provide about 40% of the annual energy requirement and a 2.5 MW base-load system. The energy options for the base-load system include: wood pellet, sewer heat, and geothermal heat. Present values of initial and operating costs of each system were calculated over 25-year service life of the systems, considering depreciation and salvage as a negative cost item. It was shown that the wood pellet heat producing technologies provided less expensive energy followed by the sewer heat recovery, geothermal and natural gas systems. Among wood pellet technologies, the grate burner was a less expensive option than powder and gasifier technologies. It was found that using natural gas as a fuel source for the peaking/backup system accounted for more than 40% of the heat production cost for the considered district heating center. This is mainly due to the high natural gas prices which cause high operating costs over the service life of the district heating system. Variations in several economic inputs did not change the ranking of the technology options in the sensitivity analysis. However, it was found that the results were more sensitive to changes in operating costs of the system than changes in initial investment. It is economical to utilize wood pellet boilers to provide the base-load energy requirement of district heating systems Moreover, the current business approach to use natural gas systems for peaking and backup in district heating systems could increase the cost of heat production significantly.

03 NATURAL GAS↗

A Monte Carlo model for 3D grain evolution during welding

Welding is one of the most wide-spread processes used in metal joining. However, there are currently no open-source software implementations for the simulation of microstructural evolution during a weld pass. Here we describe a Potts Monte Carlo based model implemented in the SPPARKS kinetic Monte Carlo computational framework. The model simulates melting, solidification and solid-state microstructural evolution of material in the fusion and heat-affected zones of a weld. The model does not simulate thermal behavior, but rather utilizes user input parameters to specify weld pool and heat-affect zone properties. Weld pool shapes are specified by Bezier curves, which allow for the specification of a wide range of pool shapes. Pool shapes can range from narrow and deep to wide and shallow representing different fluid flow conditions within the pool. Surrounding temperature gradients are calculated with the aide of a closest point projection algorithm. Furthermore, the model also allows simulation of pulsed power welding through time-dependent variation of the weld pool size. Example simulation results and comparisons with laboratory weld observations demonstrate microstructural variation with weld speed, pool shape, and pulsed-power.

36 MATERIALS SCIENCE↗

Ground Source Heat Pump Computational Results

This data submission includes simulation results for ground loop heat pump systems located in 6 different cities across the United States. The cities are Boston, MA, Dayton, OH, Omaha, NE, Orlando, FL, Sacramento, CA, and St. Paul, MN. These results were obtained from the two-dimensional geothermal computer code called GEO2D. GEO2D was written as part of this DOE funded grant. The results included in this submission for each of the 6 cities listed above are: 1) specific information on the building being heated or cooled by the ground loop geothermal system, 2) some extreme values for the building heating and cooling loads during the year, 3) the inputs required to carry out the simulation, 4) a plot of the hourly building heating and cooling loads throughout the year, 5) a plot of the fluid temperature exiting the ground loop for a 20 year period, 6) a plot of the heat exchange between the ground loop and the ground for a 20 year period, and 7) ground and ground loop temperature contour plots at different times of the year for the 20 year period.

15 GEOTHERMAL ENERGY↗