Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Quantitative characterization of collagen in the fibrotic capsule surrounding implanted polymeric microparticles through second harmonic generation imaging

The collagenous capsule formed around an implant will ultimately determine the nature of its in vivo fate. To provide a better understanding of how surface modifications can alter the collagen orientation and composition in the fibrotic capsule, we used second harmonic generation (SHG) microscopy to evaluate collagen organization and structure generated in mice subcutaneously injected with chemically functionalized polystyrene particles. SHG is sensitive to the orientation of a molecule, making it a powerful tool for measuring the alignment of collagen fibers. Additionally, SHG arises from the second order susceptibility of the interrogated molecule in response to the electric field. Variation in these tensor components distinguishes different molecular sources of SHG, providing collagen type specificity. Here, we demonstrated the ability of SHG to differentiate collagen type I and type III quantitatively and used this method to examine fibrous capsules of implanted polystyrene particles. Data presented in this work shows a wide range of collagen fiber orientations and collagen compositions in response to surface functionalized polystyrene particles. Dimethylamino functionalized particles were able to form a thin collagenous matrix resembling healthy skin. These findings have the potential to improve the fundamental understanding of how material properties influence collagen organization and composition quantitatively.

59 BASIC BIOLOGICAL SCIENCES↗

High Current Low Energy Beam Transport for Ion Implanters

One of the last remaining frontiers of the semiconductor industry is low energy ion implantation. Since the invention of the transistor, the trend has been to miniaturize semiconductor devices. As devices get smaller, shallower ion implantation for semiconductor manufacturing is needed.

Rohatgi, Upendra↗

Novel Source Development for Focused Ion Beam Implantation and Irradiation [Slides]

We have demonstrated focused ion implantation for fabrication of single atom devices and nanofabrication. This is a viable solution for prototyping - fast and easy! There is on-going work in diamond, SiN, SiC, hBN, GaN, AlGan, etc. A new liquid metal alloy ion source development is on-going. There is a pathway towards deterministic defect centers in wide bandgap materials using FIB implantation.

43 PARTICLE ACCELERATORS↗

Ultrasonic Phased Array Evaluations Of Implanted And In-Situ Grown Flaws In Cast Austenitic Stainless Steel Pressurizer Surge Line Piping

A set of circumferentially oriented thermal fatigue cracks (TFCs) were implanted into three cast austenitic stainless steel (CASS) pressurizer (PZR) surge-line specimen welds (pipe-to-elbow configuration) that were salvaged from a U.S. commercial nuclear power plant that had not been operated. Thus, these welds were fabricated using vintage CASS materials that were formed in the 1970s. Additionally, in-situ grown TFCs were placed in the adjacent CASS base material of one of these specimens. Ultrasonic phased-array responses from both types of flaws (implanted and in-situ grown) were analyzed for detection and characterization based on sizing and signal-to-noise determination. Multiple probes were employed covering the 0.8 to 2.0 MHz frequency range. To further validate the Pacific Northwest National Laboratory (PNNL) findings, an independent in-service inspection (ISI) supplier evaluated the flaws with their American Society of Mechanical Engineers (ASME) Code, Section XI, Appendix VIII-qualified procedure. The results obtained by PNNL personnel compared favorably to the ISI supplier results. All examined flaws were detected and sized within the ASME Code-allowable limits.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Surface acoustic wave probe implant for predicting epileptic seizures

A system and method for predicting and avoiding a seizure in a patient. The system and method includes use of an implanted surface acoustic wave probe and coupled RF antenna to monitor temperature of the patient's brain, critical changes in the temperature characteristic of a precursor to the seizure. The system can activate an implanted cooling unit which can avoid or minimize a seizure in the patient.

60 APPLIED LIFE SCIENCES↗

Security Risks, Low-tech User Interfaces, and Implantable Medical Devices: A Case Study with Insulin Pump Infusion Systems

Portable implantable medical device systems are playing a larger role in modern health care. Increasing attention is now being given to the wireless control interface of these systems. Our position is that wireless security in portable implantable medical device systems is just a part of the overall system security, and increased attention is needed to address low-tech security issues.

59 BASIC BIOLOGICAL SCIENCES↗

Laser process effects on physical texture and wetting in implantable Ti-alloys

Wetting is an important aspect for implantable biomaterials, as it affects the initial interaction with physiological fluids, which in turn dictates the protein adsorption, cell attachment, and tissue integration at the interface. In light of this in the present overview, surface engineering techniques based on laser processing of implantable titanium alloys for improved wettability and cell compatibility is discussed. Here three different laser processing techniques, laser interference patterning, continuous wave laser direct melting, and pulsed laser direct melting and the influence of each type of processing on the micro-texture evolution are studied Finally, the effect of micro-textures on the wettability and thereby its in vitro bioactivity and in vitro biocompatibility is systematically discussed.

Sammer, Paul↗

Multi-analyte analysis of saliva biomarkers as predictors of periodontal and pre-implant disease

The present invention relates to methods of measuring biomarkers to determine the probability of a periodontal and/or peri-implant disease. More specifically, the invention provides a panel of biomarkers that, when used in combination, can allow determination of the probability of a periodontal and/or peri-implant disease state with extremely high accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Passivated contact formation using ion implantation

Methods for forming passivated contacts include implanting compound-forming ions into a substrate to about a first depth below a surface of the substrate, and implanting dopant ions into the substrate to about a second depth below the surface. The second depth may be shallower than the first depth. The methods also include annealing the substrate.

36 MATERIALS SCIENCE↗

{sup 4}H-SiC neutron sensors based on ion implanted {sup 10}B neutron converter layer

In the framework of the I{sub S}MART project the main aim is to develop an innovative complete radiation detection system based on silicon carbide technology in view to detect neutrons (thermal and fast) and photons for harsh environments. In the present work two geometries have been realized based on ion implantation of boron. In the first geometry, {sup 10}B ions have been implanted into the Al metallic contact to create the neutron converter layer. In the second geometry one single process has been used to realize both the p+-layer and the neutron converter layer. The technological processes followed to fabricate these detectors, with a study of their electrical behavior and their responses under thermal neutron irradiations are addressed in this paper. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.↗

Dose Escalation to the Dominant Intraprostatic Lesion Defined by Sextant Biopsy in a Permanent Prostate I-125 Implant: A Prospective Comparative Toxicity Analysis

Purpose: Using real-time intraoperative inverse-planned permanent seed prostate implant (RTIOP/PSI), multiple core biopsy maps, and three-dimensional ultrasound guidance, we planned a boost volume (BV) within the prostate to which hyperdosage was delivered selectively. The aim of this study was to investigate the potential negative effects of such a procedure. Methods and Materials: Patients treated with RTIOP/PSI for localized prostate cancer with topographic biopsy results received an intraprostatic boost (boost group [BG]). They were compared with patients treated with a standard plan (reference group [RG]). Plans were generated using a simulated annealing inverse planning algorithm. Prospectively recorded urinary, rectal, and sexual toxicities and dosimetric parameters were compared between groups. Results: The study included 120 patients treated with boost technique who were compared with 70 patients treated with a standard plan. Boost technique did not significantly change the number of seeds (55.1/RG vs. 53.6/BG). The intraoperative prostate V150 was slightly higher in BG (75.2/RG vs. 77.2/BG, p = 0.039). Urethra V100, urethra D90, and rectal D50 were significantly lower in the BG. No significant differences were seen in acute or late urinary, rectal, or sexual toxicities. Conclusions: Because there were no differences between the groups in acute and late toxicities, we believe that BV can be planned and delivered to the dominant intraprostatic lesion without increasing toxicity. It is too soon to say whether a boost technique will ultimately increase local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Clinical Experience With the Strut-Adjusted Volume Implant (SAVI) Breast Brachytherapy Device for Accelerated Partial-Breast Irradiation (APBI): First 100 Patients With More Than 1 Year of Follow-Up

Purpose: The Strut-Adjusted Volume Implant (SAVI; Cianna Medical, Aliso Viejo, CA) is a multichannel single-entry brachytherapy device designed to allow dose modulation to minimize normal tissue dose while simultaneously maximizing target coverage. This is the first report on the initial 102 patients with nearly 2 years of median follow-up. Methods and Materials: One hundred two patients were treated at two institutions. Data were collected on eligibility and dosimetry and followed for toxicity and recurrence. Results: The median follow-up is 21 months. Overall dosimetry is outstanding (median percent of target volume receiving 90% of the prescription dose was 95.9%, volume of target receiving 150% of the prescription dose was 27.8 mL, and volume of target receiving 200% of the prescription dose was 14.0 cm{sup 3}). No devices were pulled prior to treatment completion. For patients with a skin bridge of less than 7 mm, the maximum median skin dose was 280 cGy (median percent of target volume receiving 90% of the prescription dose was 95.2%, volume of target receiving 150% of the prescription dose was 25.8 cm{sup 3} and volume of target receiving 200% of the prescription dose was 12.7 mL). For patients with both chest wall and skin of less than 7 mm, the maximum median lung dose was 205 cGy with simultaneous skin dose of 272 cGy. The rate of telangiectasia was 1.9%. Grade 1 hyperpigmentation developed in 10 patients (9.8%) and Grade 2 fibrosis in 2 patients (1.9%). There were 2 symptomatic seromas and 2 cases of asymptomatic fat necrosis (1.9%). Of the patients, 27% were not eligible for MammoSite balloon brachytherapy (Hologic, Inc., Marlborough, MA) and 5% were not eligible for any balloon brachytherapy. The recurrence rate was 1%. Conclusions: The SAVI appears to safely allow an increase in eligibility for APBI over balloon brachytherapy or three-dimensional conformal radiation, highlighting the outstanding device flexibility to maximize the target dose and minimize the normal tissue dose. The device was well tolerated by patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive process simulation of cryogenic implants for leading edge transistor design

Two cryogenic implant TCAD-modules have been developed: (i) A continuum-based compact model targeted towards a TCAD production environment calibrated against an extensive data-set for all common dopants. Ion-specific calibration parameters related to damage generation and dynamic annealing were used and resulted in excellent fits to the calibration data-set. (ii) A Kinetic Monte Carlo (kMC) model including the full time dependence of ion-exposure that a particular spot on the wafer experiences, as well as the resulting temperature vs. time profile of this spot. It was calibrated by adjusting damage generation and dynamic annealing parameters. The kMC simulations clearly demonstrate the importance of the time-structure of the beam for the amorphization process: Assuming an average dose-rate does not capture all of the physics and may lead to incorrect conclusions. The model enables optimization of the amorphization process through tool parameters such as scan speed or beam height.

36 MATERIALS SCIENCE↗

Magnetic and Structural Studies in Co- and Mn-implanted SrTiO3 Single Crystals

Micro Raman and static magnetization data on manganese or cobalt-implanted (at 3 or 5 at.%) strontium titanate (Mn,Co):SrTiO3 single crystals are presented. Micro Raman results reveal a cubic perovskite structure at 300 K with no evidence of any secondary phase. All samples show ferromagnetism both at 300 K and at 10 K. Moreover, micro Raman spectra at low temperature reveal the presence of polar ordering, which allow to consider the investigated materials as possible host matrices for multiferroic phenomena. Obtained results are discussed in connection to supplementary outcomes derived by content, optical absorption and electron paramagnetic resonance (EPR) measurements.

36 MATERIALS SCIENCE↗

Investigation of source-detector separation optimization for an implantable perfusion and oxygenation sensor for liver blood vessels

An implanted system is being developed to monitor transplanted liver health during the critical 7-10 day period posttransplantation. The unit will monitor organ perfusion and oxygen consumption using optically-based probes placed on both the inflow and outflow blood vessels, and on the liver parenchymal surface. Sensing probes are based on a 3- wavelength LED source and a photodiode detector. Sample diffuse reflectance is measured at 735, 805, and 940 nm. To ascertain optimal source-to-photodetector spacing for perfusion measurement in blood vessels, an ex vivo study was conducted. In this work, a dye mixture simulating 80% blood oxygen saturation was developed and perfused through excised porcine arteries while collecting data for various preset probe source-to-photodetector spacings. The results from this study demonstrate a decrease in the optical signal with decreasing LED drive current and a reduction in perfusion index signal with increasing probe spacing. They also reveal a 2- to 4-mm optimal range for blood vessel perfusion probe source-to-photodetector spacing that allows for sufficient perfusion signal modulation depth with maximized signal to noise ratio (SNR). These findings are currently being applied to guide electronic configuration and probe placement for in vivo liver perfusion porcine model studies.

60 APPLIED LIFE SCIENCES↗

Modulating Oxide‐Based Quantum Materials by Ion Implantation

Ion implantation has emerged as a powerful tool for manipulating and investigating oxide quantum materials, where strong electron correlations give rise to exotic phases and functionalities. This Review examines how controlled ion bombardment enables targeted modulation of structural, electronic, and magnetic properties in complex oxides. Recent advances in ion beam techniques is analyzed that provide unprecedented control over defect profiles, from point defects to extended damage cascades. In application, ion irradiation has demonstrated the ability to tune quantum phenomena including metal‐insulator transitions, magnetism, and superconductivity through selective doping, defect creation, and lattice strain. The ability to write quantum states with nanoscale precision using focused ion beams is opening new paths for quantum device fabrication. Challenges in understanding radiation damage mechanisms in strongly correlated systems is discussed, and identify opportunities for designing quantum functionality through defect‐engineering approaches. The technique's demonstrated capability to write quantum states with nanoscale precision, combined with its compatibility with existing semiconductor processing infrastructure, suggests a clear pathway for translating fundamental discoveries in quantum materials into practical technological applications.

defect engineering↗

In Situ Engineering of Intracellular Hemoglobin for Implantable High-Performance Biofuel Cells

The key challenge for the broad application of implantable biofuel cells (BFCs) is to achieve inorganic–organic composite biocompatibility while improving the activity and selectivity of the catalysts. We have fabricated nanoengineered red blood cells (NERBCs) by an environmentally friendly method by using red blood cells as the raw material and hemoglobin (Hb) embedded with ultrasmall hydroxyapatite (HAP, Ca 10 (PO 4 ) 6 (OH) 2 ) as the functional BFC cathode material. The NERBCs showed greatly enhanced cell performance with high electrocatalytic activity, stability, and selectivity. The NERBCs maintained the original biological properties of the natural cell, while enhancing the catalytic oxygen reduction reaction (ORR) through the interaction between -OH groups in HAP and the Hb in RBCs. Finally, they also enabled direct electron transportation, eliminating the need for an electron-transfer mediator, and showed catalytic inactivity for glucose oxidation, thus potentially enabling the development of separator-free BFCs.

09 BIOMASS FUELS↗