Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

CUPRI system configuration for NLC-91 and observations of PMSE during Salvo A

The Cornell University Portable Radar Interferometer (CUPRI) provided nearly continuous monitoring of the mesosphere above Esrange, Sweden during the noctilucent cloud rocket and radar campaign of the summer of 1991 (NLC-91). CUPRI probed the mesosphere above Esrange from 78 to 91 km altitude with 300-meter resolution and was sensitive to the enhanced Polar Mesospheric Summer Echoes (PMSE) that occur in the same altitude range as NLC formations. Out of the total of 264 hours of CUPRI observation time, PMSE were present for 140 hours. Rocket Salvo A was flown on the night of August 9-10 into an NLC event that occurred simultaneously with a thin and weakening PMSE layer. High-resolution Doppler spectrograms of this PMSE event revealed sawtooth-like discontinuities at approximately 83 km altitude, which we interpret to be a distorted partial reflection layer which was advected across the radar beam.

Swartz, Wesley E.↗

Systems Engineering and Application of System Performance Modeling in SIM Lite Mission

The SIM Lite Astrometric Observatory will be the first space-based Michelson interferometer operating in the visible wavelength, with the ability to perform ultra-high precision astrometric measurements on distant celestial objects. SIM Lite data will address in a fundamental way questions such as characterization of Earth-mass planets around nearby stars. To accomplish these goals it is necessary to rely on a model-based systems engineering approach - much more so than most other space missions. This paper will describe in further detail the components of this end-to-end performance model, called "SIM-sim", and show how it has helped the systems engineering process.

Exoplanet↗

THE STRUCTURE OF THE {beta} LEONIS DEBRIS DISK

We combine nulling interferometry at 10 {mu}m using the MMT and Keck Telescopes with spectroscopy, imaging, and photometry from 3 to 100 {mu}m using Spitzer to study the debris disk around {beta} Leo over a broad range of spatial scales, corresponding to radii of 0.1 to {approx}100 AU. We have also measured the close binary star o Leo with both Keck and MMT interferometers to verify our procedures with these instruments. The {beta} Leo debris system has a complex structure: (1) relatively little material within 1 AU; (2) an inner component with a color temperature of {approx}600 K, fitted by a dusty ring from about 2-3 AU; and (3) a second component with a color temperature of {approx}120 K fitted by a broad dusty emission zone extending from about {approx}5 AU to {approx}55 AU. Unlike many other A-type stars with debris disks, {beta} Leo lacks a dominant outer belt near 100 AU.

79 ASTRONOMY AND ASTROPHYSICS↗

Meteorological satellite products support for project COHMEX

The first year effort focussed on real-time support and satellite data collection during the field phase of COHMEX. Work efforts following the field phase of COHMEX concentrated on post-processing of the real-time data sets, and generation of enhanced, research-quality satellite data sets for selected COHMEX core days. These satellite-derived data sets will augment the special COHMEX conventional data base with high horizontal and temporal resolution information. The data sets will be examined for their usefulness in delineating important elements in the meteorological environment leading to convective activity. In addition, a limited research effort was conducted using the Cooperative Institute for Meteorological Satellite Studies (CIMSS) 4-d data assimilation system in conjunction with evaluating VISSR Atmospheric Sounder (VAS) and His-resolution Interferometer Sounder (HIS) data. The need to address the characteristics of the data types, and the problems they introduce into 4-d assimilation procedures is evident. The HIS instrument was flown aboard an ER-2 aircraft on several occasions during COHMEX. One of the flights was chosen for further study. Processed VAS soundings and COHMEX radiosonde data were also collected for this day. The case study included an evaluation of the HIS and VAS data and an impact study of the data on the assimilation system analysis.

Velden, Christopher S.↗

Comparisons of SiO maser and long-period variable positions in the R Aquarii and Omicron Ceti binary systems

It has been determined that the absolute position of the centroid of SiO maser-emitting spots toward both R Aqr and Omicron Cet are coincident with the position of the long-period variables (LPVs) in these binary systems to within the errors of measurement. The SiO positions were determined with the Hat Creek interferometer, while the LPV positions were determined with the 8-in transit circle of the US Naval Observatory. These results contradict an earlier report of a circumbinary SiO maser far removed from the LPV in the R Aqr binary system; statistical reasons for the discrepancy are suggested. High-resolution spectra of both sources are presented and possible models are discussed.

Hollis, J. M.↗

A multi-point laser Doppler vibrometer with fiber-based configuration

Laser Doppler vibrometer (LDV) is a non-contact optical interferometric system to measure vibrations of structures and machines with a high precision. Normal LDV can only offer a single-point measurement. Scanning LDV is usually impractical to do measurement on transient events. In this paper, a fiber-based self-synchronized multi-point LDV is proposed. The multiple laser beams with different frequency shifts are generated from one laser source. The beams are projected onto a vibrating object, reflected and interfered with a common reference beam. The signal including vibration information of multiple spatial points is captured by one single-pixel photodetector. The optical system is mainly integrated by fiber components for flexibility in measurement. Two experiments are conducted to measure a steady-state simple harmonic vibration of a cantilever beam and a transient vibration of a beam clamped at both ends. In the first measurement, a numerical interpolation is applied to reconstruct the mode shape with increased number of data points. The vibration mode obtained is compared with that from FEM simulation. In transient vibration measurement, the first five resonant frequencies are obtained. The results show the new-reported fiber-based multipoint LDV can offer a vibration measurement on various spatial points simultaneously. With the flexibility of fiber configuration, it becomes more practical for dynamic structural evaluation in industrial areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CARMA CO observations of three extremely metal-poor, star-forming galaxies

We present sensitive CO (J = 1 → 0) emission line observations of the three metal-poor dwarf irregular galaxies Leo P (Z ∼ 3% Z{sub ⊙}), Sextans A (Z ∼ 7.5% Z{sub ⊙}), and Sextans B (Z ∼ 7.5% Z{sub ⊙}), all obtained with the Combined Array for Millimeter-wave Astronomy interferometer. While no CO emission was detected, the proximity of the three systems allows us to place very stringent (4σ) upper limits on the CO luminosity (L{sub CO}) in these metal-poor galaxies. We find the CO luminosities to be L{sub CO} < 2900 K km s{sup −1} pc{sup 2} for Leo P, L{sub CO} < 12,400 K km s{sup −1} pc{sup 2} for Sextans A, and L{sub CO} < 9700 K km s{sup −1} pc{sup 2} for Sextans B. Comparison of our results with recent observational estimates of the factor for converting between L{sub CO} and the mass of molecular hydrogen, as well as theoretical models, provides further evidence that either the CO-to-H{sub 2} conversion factor increases sharply as metallicity decreases, or that stars are forming in these three galaxies very efficiently, requiring little molecular hydrogen.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical path control in the MAM testbed

Future space-based optical interferometers will require control of the optical path delay to accomplish some or all of the three objectives: balancing the optical path in the two arms to within a tolerance corresponding to the coherence length of the star light being observed, modulating the optical path in order to observe the phase of the star light interference fringe, and modulating the path length in order to reduce the effect of cyclic errors in the laser metrology system used to measure the optical path length in the two arms of the interferometer.

optical interferometers optical path MAM testbed M↗

Aligning Three Off-Axis Mirrors with Help of a DOE

A proposed method based on the use of a special-purpose diffractive optical element (DOE) would simplify (relative to prior methods) the alignment of three off-axis mirrors that constitute an imaging optical system. The method would exploit the fact that a DOE can be fabricated lithographically with high accuracy by electron-beam lithography in a thin film of poly(methyl methacrylate). The method would effectively transfer much of the problem of obtaining the needed accuracy from the mechanical-mirror-alignment domain to the lithographic domain. Unlike other methods that depend on specific symmetries (e.g., sphericity and/or concentricity), this method is expected to apply with equal ease and accuracy to mirrors of any configuration including aspherical, decentered mirrors. Assuming that one of the mirrors of a general three-mirror imaging optical system can serve as a reference for the alignment of the other two mirrors, such a system has 12 degrees of freedom in alignment. In the proposed method, one would use an interferometer in combination with a DOE to effect precise and relatively rapid and easy alignment of two of the mirrors with respect to each other, thus reducing the alignment task to that of the six degrees of freedom of the remaining mirror. The figure depicts a representative three-mirror off-axis imaging system, wherein the primary and tertiary mirrors (M1 and M3, respectively) are concave and the secondary mirror (M2) is convex. The DOE for aligning this system would be fabricated on the right surface of an optical flat and could be made to have either negative or positive focusing power, depending on the requirements of the specific application. The DOE could be designed to be placed at any convenient distance from M1 and M3 - again, depending on the application. The DOE would be illuminated with light coming from the left, generated by an interferometer. First, assuming the optical flat is of high quality, the plane of the DOE would be aligned perpendicular to the collimated beam by use of light reflected from the left face of the optical flat. The DOE would comprise two independent areas: one dedicated to M1, the other to M3. The portions of the collimated beam passing through those areas would be diffracted towards the corresponding mirrors. A mask, not shown in the figure, could be used to prevent light from passing through the rest of the area of the optical flat. Light rays reflected from M1 and M3 would retrace their paths through the DOE and would propagate leftward to the interferometer.

Mouroulis, Pantazis↗

The Table Mountain 8-mm wavelength interferometer

A two-element radio interferometer operating at 8.33-mm wavelength has been developed at the Jet Propulsion Laboratory's Table Mountain Observatory near Wrightwood, CA. The interferometer employs a 5.5-m and a 3-m diameter antenna on an east-west baseline of 60 or 120 m, yielding fringe spacings at transit of 28 or 14 arcsec, respectively. The broad intermediate-frequency bandpass of 100-350 MHz and the system noise temperature of 500 K provide high sensitivity for the measurement of continuum sources. The interferometer has been used for high-resolution studies of the planets and the sun, and it is currently being adapted to study solar flare emissions at high spatial and time resolution.

Janssen, M. A.↗

Thermal-Mechanical Analysis for in-Vessel Diagnostic Components in W7-X

For long pulse plasma operation of the W7-X stellarator, the most serious challenge for the design of in-vessel diagnostic systems is the thermo-mechanical problem. Thermal load from convective losses and from plasma radiation can be as high as 500 kW/m{sup 2} at some locations close to plasma. The typical thermal load from plasma radiation alone ranges from several 10 to 100 kW/m{sup 2} as derived from 3-D Monte-Carlo simulations. A finite element analysis (FEA-ANSYS) is conducted for a better understanding of thermo-mechanical effects on in-vessel diagnostic components and to guide the design of the diagnostic system for steady state operation. All in-vessel diagnostic components require active cooling. Besides for long-pulse plasma operation optical components must be optimized to minimize thermal deformations. In this paper, we present the thermo-mechanical analyses of the CO{sub 2}-laser interferometer retro-reflectors, the diamagnetic loops and the soft X-ray multi camera tomography system (XMCTS)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geodetic measurements with a mobile VLBI system

The Project ARIES 9 meter transportable antenna was used as one element of very long baseline interferometer (VLBI) to begin monitoring locations of six sites in California relative to large diameter fixed antennas at the NASA Deep Space Network, Goldstone, California, and at the Caltech Owens Valley Radio Observatory, Big Pine, California. An accuracy of about 6 cm in the horizontal components was demonstrated by comparison with measurements of the National Geodetic Survey. The root of mean square scatter of the lengths of the baselines between any pair of antennas was about 3 cm except for the Goldstone-JPL (Pasadena) baseline. In the period August 1974 to August 1977 the length of this baseline increased by 15 + or - 5 cm as JPL moved westward relative to Goldstone at the rate of 6 + or - 2 cm/year. The baseline lengths were unaffected by the uncertainties of UT1, polar motion, and tropospheric water vapor, which are the limitations to present three dimensional vector accuracies.

Niell, A. E.↗

Optical system and method for gas detection and monitoring

A free-space optical path of an optical interferometer is disposed in an environment of interest. A light beam is guided to the optical interferometer using a single-mode optical fiber. The light beam traverses the interferometer's optical path. The light beam guided to the optical path is combined with the light beam at the end of the optical path to define an output light. A temporal history of the output light is recorded.

Polzin, Kurt A.↗

MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

60 APPLIED LIFE SCIENCES↗

Development of a State Machine Sequencer for the Keck Interferometer: Evolution, Development and Lessons Learned using a CASE Tool Approach

This paper presents a discussion of the evolution of a sequencer from a simple EPICS (Experimental Physics and Industrial Control System) based sequencer into a complex implementation designed utilizing UML (Unified Modeling Language) methodologies and a CASE (Computer Aided Software Engineering) tool approach. The main purpose of the sequencer (called the IF Sequencer) is to provide overall control of the Keck Interferometer to enable science operations be carried out by a single operator (and/or observer). The interferometer links the two 10m telescopes of the W. M. Keck Observatory at Mauna Kea, Hawaii. The IF Sequencer is a high-level, multi-threaded, Hare1 finite state machine, software program designed to orchestrate several lower-level hardware and software hard real time subsystems that must perform their work in a specific and sequential order. The sequencing need not be done in hard real-time. Each state machine thread commands either a high-speed real-time multiple mode embedded controller via CORB A, or slower controllers via EPICS Channel Access interfaces. The overall operation of the system is simplified by the automation. The UML is discussed and our use of it to implement the sequencer is presented. The decision to use the Rhapsody product as our CASE tool is explained and reflected upon. Most importantly, a section on lessons learned is presented and the difficulty of integrating CASE tool automatically generated C++ code into a large control system consisting of multiple infrastructures is presented.

interferometer↗

Experimental and numerical study of plastic shear instability under high-speed loading conditions

The behavior of specimens dynamically loaded during the split Hopkinson (Kolsky) bar tests in a regime close to simple shear conditions was studied. The lateral surface of the specimens was investigated in a real-time mode with the aid of a high-speed infra-red camera CEDIP Silver 450M. The temperature field distribution obtained at different time made it possible to trace the evolution of plastic strain localization. The process of target perforation involving plug formation and ejection was examined using a high-speed infra-red camera and a VISAR velocity measurement system. The microstructure of tested specimens was analyzed using an optical interferometer-profilometer and a scanning electron microscope. The development of plastic shear instability regions has been simulated numerically.

36 MATERIALS SCIENCE↗

Study of plastic strain localization mechanisms caused by nonequilibrium transitions in mesodefect ensembles under high-speed loading

The behavior of specimens dynamically loaded during split Hopkinson (Kolsky) bar tests in a regime close to simple shear conditions was studied. The lateral surface of the specimens was investigated in-situ using a high-speed infrared camera CEDIP Silver 450M. The temperature field distribution obtained at different time allowed one to trace the evolution of plastic strain localization. The process of target perforation involving plug formation and ejection was examined using a high-speed infrared camera and a VISAR velocity measurement system. The microstructure of tested specimens was analyzed using an optical interferometer-profiler and a scanning electron microscope. The development of plastic shear instability regions has been simulated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗