Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Room Temperature Epitaxial Stabilization of a Tetragonal Phase in AruO(3) (A=Ca And Sr) Thin Films

We demonstrate that SrRuO{sub 3} and CaRuO{sub 3} thin films undergo a room temperature structural phase transition driven by the substrate imposed epitaxial biaxial strain. As tensile strain increases, ARuO{sub 3} (A=Ca and Sr) films transform from the orthorhombic phase which is usually observed in bulk SrRuO{sub 3} and CaRuO{sub 3} at room temperature into a tetragonal phase which in bulk samples is only stable at higher temperatures. More importantly, we show that the observed phenomenon strongly affects the electronic and magnetic properties of ARuO{sub 3} thin films that are grown on different single crystal substrates which, in turn, offers the possibility to tune these properties.

36 MATERIALS SCIENCE↗

Membrane insertion for the detection of lipopolysaccharides: Exploring the dynamics of amphiphile-in-lipid assays

Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assays to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.

59 BASIC BIOLOGICAL SCIENCES↗

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

Enhancement of the Magnetocaloric Effect in Composites Based on La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} (Re = Dy, Gd, and Eu) Polycrystalline Manganites

In this communication, we have used theoretical calculations in order to prepare a composite with an enhanced magnetocaloric effect from La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} (Re = Dy, Gd, and Eu) samples. Although the obtained composites did not exhibit very important values of magnetic entropy change (− ΔS), they are active in a very wide temperature range. One of the composites is characterized by a plateau-like shape of − ΔS(T) curves. Several anomalies were found in the magnetic and the magnetocaloric properties of our composites. The origin of these anomalies is essentially attributed to the phase separation phenomenon characterizing all the La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cd-rich and Te-rich low-temperature photoluminescence in cadmium telluride

Low-temperature photoluminescence emission spectra were measured in cadmium telluride (CdTe) samples in which composition was varied to promote either Cd or Te-rich stoichiometry. The ability to monitor stoichiometry is important, since it has been shown to impact carrier recombination. Te-rich samples show transitions corresponding to acceptor-bound excitons (∼1.58 eV) and free-electron to acceptor transitions (∼1.547 eV). In addition to acceptor-bound excitons, Cd-rich samples show transitions assigned to donor-bound excitons (1.591 eV) and Te vacancies at 1.552 eV. Photoluminescence is a noninvasive way to monitor stoichiometric shifts induced by post-deposition anneals in polycrystalline CdTe thin films deposited by close-spaced sublimation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffuse reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.

Visible near-infrared spectroscopy, integrating sp↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Out-of-distribution detection with non-parametric density estimation for models predicting processing history of uranium ore concentrates

The rapid advancement in machine learning (ML) and computer vision (CV) coincides with the growth of interest in deploying these ML/CV models in numerous fields from medicine to social science. Similar to those areas, we have witnessed a great number of works in materials science employing ML/CV models – neural networks in particular – in their studies in recent years. These models have proven to obtain accurate performance in various tasks. However, these models struggle to attain a similar performance when encountering test samples coming from a distribution that is different from the training set. More importantly, they fail without providing any warning to the users. Therefore, we propose a framework for detecting out-of-distribution (OOD) samples to alert users when a human intervention might be necessary in this work. Specifically, we explore the use of a non-parametric density estimation method to detect OOD samples. Here, we assess OOD detection capability of the proposed framework on ML models developed for categorizing precipitation routes of U 3 O 8 when encountering OOD datasets that contain samples (1) undergone different imaging acquisition process, (2) undergone different material synthesis process, and (3) different materials than ID set. Through those experiments, we achieve an average area under the receiver operating characteristic (AUROC) of at least 91% on average in detecting OOD samples. With minimal overhead cost and superior performance, the proposed framework enables a reliable and safe system when deploying in real-world scenarios.

Convolutional neural networks↗

Measurement report: Molecular composition, optical properties, and radiative effects of water-soluble organic carbon in snowpack samples from northern Xinjiang, China

Abstract. Water-soluble organic carbon (WSOC) in the cryosphere has an important impact on the biogeochemistry cycling and snow–ice surface energy balance through changes in the surface albedo. This work reports on the chemical characterization of WSOC in 28 representative snowpack samples collected across a regional area of northern Xinjiang, northwestern China. We employed multimodal analytical chemistry techniques to investigate both bulk and molecular-level composition of WSOC and its optical properties, informing the follow-up radiative forcing (RF) modeling estimates. Based on the geographic differences and proximity of emission sources, the snowpack collection sites were grouped as urban/industrial (U), rural/remote (R), and soil-influenced (S) sites, for which average WSOC total mass loadings were measured as 1968 ± 953 ng g−1 (U), 885 ± 328 ng g−1 (R), and 2082 ± 1438 ng g−1 (S), respectively. The S sites showed the higher mass absorption coefficients at 365 nm (MAC365) of 0.94 ± 0.31 m2 g−1 compared to those of U and R sites (0.39 ± 0.11 m2 g−1 and 0.38 ± 0.12 m2 g−1, respectively). Bulk composition of WSOC in the snowpack samples and its basic source apportionment was inferred from the excitation–emission matrices and the parallel factor analysis featuring relative contributions of one protein-like (PRLIS) and two humic-like (HULIS-1 and HULIS-2) components with ratios specific to each of the S, U, and R sites. Additionally, a sample from site 120 showed unique pollutant concentrations and spectroscopic features remarkably different from all other U, R, and S samples. Molecular-level characterization of WSOC using high-resolution mass spectrometry (HRMS) provided further insights into chemical differences among four types of samples (U, R, S, and 120). Specifically, many reduced-sulfur-containing species with high degrees of unsaturation and aromaticity were uniquely identified in U samples, suggesting an anthropogenic source. Aliphatic/protein-like species showed the highest contribution in R samples, indicating their biogenic origin. The WSOC components from S samples showed high oxygenation and saturation levels. A few unique CHON and CHONS compounds with high unsaturation degree and molecular weight were detected in the 120 sample, which might be anthraquinone derivatives from plant debris. Modeling of the WSOC-induced RF values showed warming effects of 0.04 to 0.59 W m−2 among different groups of sites, which contribute up to 16 % of that caused by black carbon (BC), demonstrating the important influences of WSOC on the snow energy budget.

54 ENVIRONMENTAL SCIENCES↗

To Sample or Not to Sample - An Investigation Into the Uncertainty from Sampling Followed by Laboratory Analysis Versus In-Toto Gamma Spectroscopy for Situations of Non-Uniform Radioactivity Distribution

During the decommissioning of structures and the remediation of soil, material that is known or suspected to be contaminated with radioactivity must be assayed. For many, if not most, of the cases, the radioactive material concentration can be determined or inferred by gamma spectroscopy. In most, if not all, of these cases, the radioactivity is not uniformly distributed. For these situations, is it better to perform in-toto measurements of the entire item, or is it better to extract a sample and analyze that sample? For the in-toto gamma spectroscopy measurement, the results will not be accurate unless the calibration method perfectly represents the measured item. And since the calibrations normally assume uniformly distributed radioactivity, any nonuniform distribution of radioactivity in the measured material will cause an error in the results. A mathematical program using probabilistic methods has been developed to estimate the uncertainty in in-toto gamma spectroscopy measurements. This program has the capability of determining the efficiency of various types of non-uniform radioactivity distributions and to compare it to the uniform distribution efficiency. Repeating this for a large number of random tries allows the estimation of the measurement uncertainty. A new feature has been added to the program to simulate the extraction of a sample from these same non-uniform distributions, to compute the average concentration in this extracted sample, and to compare it to the average concentration in the original item to be measured. Repeating this for a large number of random tries allows the estimation of the sampling uncertainty. These two computations were run on several different 'typical' contamination measurement scenarios [200 liter drums, 27 cubic meter 'truck' containers, 0.01-10 liter 'laboratory' containers, and 3600 square meter soil 'in-situ' plots]. In all cases examined, the sampling uncertainty was larger than the in-toto gamma measurement uncertainty - typically about an order of magnitude larger. This means that in-toto measurements are likely better for situations where the activity is not homogeneous, and where gamma spectroscopy is appropriate. If sampling is to be done, then the best results will be when the largest mass of sample is extracted and when it is made up from the largest number of discrete sub-samples. The more extreme the non-uniformity, the more important this is. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of pectin-degrading fungal communities in temperate forests using glycosyl hydrolase family 28 pectinase primers targeting Ascomycete fungi

Here, fungi have developed a wide assortment of enzymes to break down pectin, a prevalent polymer in plant cell walls that is important in plant defense and structure. One enzyme family used to degrade pectin is the glycosyl hydrolase family 28 (GH28). In this studywe developed primers for the amplification of GH28 coding genes from a database of 293 GH28 sequences from40 fungal genomes. The primerswere used to successfully amplify GH28 pectinases from all Ascomycota cultures tested, but only three out of seven Basidiomycota cultures. In addition, we further tested the primers in PCRs on metagenomic DNA extracted from senesced tree leaves from different forest ecosystems, followed by cloning and sequencing. Taxonomic specificity for Ascomycota GH28 genes was tested by comparing GH28 composition in leaves to internal transcribed spacer (ITS) amplicon composition using pyrosequencing. All sequences obtained from GH28 primers were classified as Ascomycota; in contrast, ITS sequences indicated that fungal communitieswere up to 39% Basidiomycetes. Analysis of leaf samples indicated that both forest stand and ecosystemtype were important in structuring fungal communities. However, site played the prominent role in explaining GH28 composition, whereas ecosystem type was more important for ITS composition, indicating possible genetic drift between populations of fungi. Overall, these primers will have utility in understanding relationships between fungal community composition and ecosystem processes, as well as detection of potentially pathogenic Ascomycetes.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of variation in indium concentration on the photosensitivity of chlorine doped In{sub 2}S{sub 3} thin films

Consequence of variation in Indium concentration in chlorine doped In2S{sub 3} thin films deposited by spray pyrolysis technique was studied. Chlorine was incorporated in the spray solution, using HCl and Indium concentration was varied by adjusting In/S ratio Interestingly, the photo response of all chlorine doped samples augmented compared to pristine samples; but the highest photosensitivity value of ∼2300 was obtained only when 36ml 0.5M HCl was added to the solution of In{sub 2}S{sub 3} having In/S=2/8. It was also observed that samples with high photosensitivity possess higher band gap and variation in sub band gap absoption levels were observed with increase in Indium concentration. The present study proved that concentration of Indium plays an important role in controlling the crystallinity and photosensitivity of chlorine doped samples.

36 MATERIALS SCIENCE↗

Characterization of Hydrogen in Basaltic Materials With Laser-Induced Breakdown Spectroscopy (LIBS) for Application to MSL ChemCam Data

Here, the Mars Science Laboratory rover, Curiosity , is equipped with ChemCam, a laser–induced breakdown spectroscopy (LIBS) instrument, to determine the elemental composition of nearby targets quickly and remotely. We use a laboratory sample set including prepared mixtures of basalt with systematic variation in hydrated mineral content and compositionally well–characterized, altered basaltic volcanic rocks to measure hydrogen by characterizing the H–alpha emission line in LIBS spectra under Martian environmental conditions. The H contents of all samples were independently measured using thermogravimetric analysis. We found that H peak area increases with weight percent H for our laboratory mixtures with basaltic matrices. The increase is linear with weight percent H in the mixtures with structurally bound H up to about 1.25 wt.% H and then steepens for higher H–content samples, a nonlinear trend not previously reported but potentially important for characterizing high water content materials. To compensate for instrument, environmental, and target matrix–related effects on quantification of H content from the LIBS signal, we examined multiple normalization methods. The best performing methods utilize O 778– and C 248–nm emission lines. The methods return comparable results when applied to ChemCam data of H–bearing materials on Mars. The calibration and normalization methods tested here will aid in investigations of H by LIBS on Mars with ChemCam and SuperCam. Further laboratory work will aid quantification across different physical matrices and heterogeneous textures because of differences we observed in H in pelletized and natural rock samples of the same composition.

58 GEOSCIENCES↗

Improved Thermal Stability of Oxysulfide Glassy Solid-State Electrolytes

In this study, the crystallization kinetics of (oxy)sulfide 70Li 2 S·(30-x)P 2 S 5 ·xP 2 O 5 (x = 0, 2, 5) solid-state electrolytes are reported. It was found that 5 mol% P 2 O 5 glass co-former slowed the crystallization rate of the Li 7 P 3 S 11−x/4 O x/4 ceramic phase by a factor of 10. After 10 min at 230 °C, a 70Li 2 S·30P 2 S 5 sulfide glass was 92% devitrified whereas a 70Li 2 S·25P 2 S 5 ·5P 2 O 5 oxysulfide glass was only 8% devitrified. The improved thermal stability of oxysulfide glasses was then utilized to demonstrate the fabrication of a standalone, reinforced SSE separator by hot pressing. More importantly, it was recognized that the microstructure of 70Li 2 S·25P 2 S 5 ·5P 2 O 5 oxysulfide SSE separators could be modified by hot pressing without changing ionic conductivity. This result was achieved because the precipitation of a superionically conductive Li 7 P 3 S 11−x/4 O x/4 ceramic phase was limited. A study was then conducted to determine what effect microstructure has on the susceptibility of SSE separators to shorting by lithium metal penetration. Hot-pressed separators were found to be more susceptible to shorting than cold-pressed separators. X-ray Computer Tomography (XCT) of post-mortem samples showed that hot-pressed samples failed by transverse microcrack pathways, which underscores the importance of low defect density in dense SSE separators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

H II REGION METALLICITY DISTRIBUTION IN THE MILKY WAY DISK

The distribution of metals in the Galaxy provides important information about galaxy formation and evolution. H II regions are the most luminous objects in the Milky Way at mid-infrared to radio wavelengths and can be seen across the entire Galactic disk. We used the National Radio Astronomy Observatory (NRAO) Green Bank Telescope to measure radio recombination line and continuum emission in 81 Galactic H II regions. We calculated LTE electron temperatures using these data. In thermal equilibrium metal abundances are expected to set the nebular electron temperature with high abundances producing low temperatures. Our H II region distribution covers a large range of Galactocentric radius (5-22 kpc) and samples the Galactic azimuth range 330{sup 0}-60{sup 0}. Using our highest quality data (72 objects) we derived an O/H Galactocentric radial gradient of -0.0383 {+-} 0.0074 dex kpc{sup -1}. Combining these data with a similar survey made with the NRAO 140 Foot telescope we get a radial gradient of -0.0446 {+-} 0.0049 dex kpc{sup -1} for this larger sample of 133 nebulae. The data are well fit by a linear model and no discontinuities are detected. Dividing our sample into three Galactic azimuth regions produced significantly different radial gradients that range from -0.03 to -0.07 dex kpc{sup -1}. These inhomogeneities suggest that metals are not well mixed at a given radius. We stress the importance of homogeneous samples to reduce the confusion of comparing data sets with different systematics. Galactic chemical evolution models typically derive chemical evolution along only the radial dimension with time. Future models should consider azimuthal evolution as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Path length dependent neutron diffraction peak shifts observed during residual strain measurements in U–8 wt% Mo castings

This study reports an angular diffraction peak shift that scales linearly with the neutron beam path length traveled through a diffracting sample. This shift was observed in the context of mapping the residual stress state of a large U–8 wt% Mo casting, as well as during complementary measurements on a smaller casting of the same material. If uncorrected, this peak shift implies a non-physical level of residual stress. A hypothesis for the origin of this shift is presented, based upon non-ideal focusing of the neutron monochromator in combination with changes to the wavelength distribution reaching the detector due to factors such as attenuation. The magnitude of the shift is observed to vary linearly with the width of the diffraction peak reaching the detector. Consideration of this shift will be important for strain measurements requiring long path lengths through samples with significant attenuation. This effect can probably be reduced by selecting smaller voxel slit widths.

36 MATERIALS SCIENCE↗