Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Insert facing tool

A manually actuated tool for facing the exposed end of an insert installed in a honeycomb panel is described. Several cutting bits are held in a round body portion that is rotated around the end of a stud to provide the cutting action. Pressure is adjusted through a spring against the body portion and the surface of the stud by a pressure nut threaded on the stud. A diagram of the components of the device is provided.

Abernathy, W. J.↗

1st Order Modeling of a SAW Delay Line using MathCAD(Registered)

To aid in the development of SAW sensors for Integrated Vehicle Health Monitoring applications, a first order model of a SAW Delay line has been created using MathCadA. The model implements the Impulse Response method to calculate the frequency response, impedance, and insertion loss. This paper presents the model and the results from the model for a SAW delay line design. Integrated Vehicle Health Monitoring (IVHM) of aerospace vehicles requires rugged sensors having reduced volume, mass, and power that can be used to measure a variety of phenomena. Wireless systems are preferred when retro-fitting sensors onto existing vehicles [1]. Surface Acoustic Wave (SAW) devices are capable of sensing: temperature, pressure, strain, chemical species, mass loading, acceleration, and shear stress. SAW technology is low cost, rugged, lightweight, and extremely low power. Passive wireless sensors have been developed using SAW technology. For these reasons new SAW sensors are being investigated for aerospace applications.

Wilson, William C.↗

A broadband RF continuously variable time delay device

A method for implementation of continuously variable time delay of broadband RF signals is described. The method uses Bragg Cell and optical heterodyne technology. The signal to be delayed is applied to the Bragg Cell acoustic transducer, and the delay time is the acoustic transit time from this transducer to the incident light beam. By translating the light beam, the delay is varied. Expressions describing the Bragg Cell diffraction, lens Fourier transformation, and the optical heterodyne processes are developed. Specifications for the variable delay including bandwidth, range of delay, and insertion loss are provided. Applications include radar signal processing, spread spectrum intercept, radar ECM, and adaptive array antenna processing.

Freyre, F. W.↗

Lightning discharge protection rod

A system for protecting an in-air vehicle from damage due to a lighning strike is disclosed. It is an extremely simple device consisting of a sacrificial graphite composite rod, approximately the diameter of a pencil with a length of about five inches. The sacrificial rod is constructed with the graphite fibers running axially within the rod in a manner that best provides a path of conduction axially from the trailing edge of an aircraft to the trailing end of the rod. The sacrificial rod is inserted into an attachment hole machined into trailing edges of aircraft flight surfaces, such as a vertical fin cap and attached with adhesive in a manner not prohibiting the conduction path between the rod and the aircraft. The trailing end of the rod may be tapered for aerodynamic and esthetic requirements. This rod is sacrificial but has the capability to sustain several lightning strikes and still provide protection.

Bryan, Charles F., Jr.↗

Threaded average temperature thermocouple

A threaded average temperature thermocouple 11 is provided to measure the average temperature of a test situs of a test material 30. A ceramic insulator rod 15 with two parallel holes 17 and 18 through the length thereof is securely fitted in a cylinder 16, which is bored along the longitudinal axis of symmetry of threaded bolt 12. Threaded bolt 12 is composed of material having thermal properties similar to those of test material 30. Leads of a thermocouple wire 20 leading from a remotely situated temperature sensing device 35 are each fed through one of the holes 17 or 18, secured at head end 13 of ceramic insulator rod 15, and exit at tip end 14. Each lead of thermocouple wire 20 is bent into and secured in an opposite radial groove 25 in tip end 14 of threaded bolt 12. Resulting threaded average temperature thermocouple 11 is ready to be inserted into cylindrical receptacle 32. The tip end 14 of the threaded average temperature thermocouple 11 is in intimate contact with receptacle 32. A jam nut 36 secures the threaded average temperature thermocouple 11 to test material 30.

Ward, Stanley W.↗

Study of and proposals for the correction of errors in a radar ranging device designed to facilitate docking of a teleoperator maneuvering system

A frequency modulated continuous wave radar system was developed. The system operates in the 35 gigahertz frequency range and provides millimeter accuracy range and range rate measurements. This level of range resolution allows soft docking for the proposed teleoperator maneuvering system (TMS) or other autonomous or robotic space vehicles. Sources of error in the operation of the system which tend to limit its range resolution capabilities are identified. Alternative signal processing techniques are explored with emphasis on determination of the effects of inserting various signal filtering circuits in the system. The identification and elimination of an extraneous low frequency signal component created as a result of zero range immediate reflection of radar energy from the surface of the antenna dish back into the mixer of the system is described.

Mcdonald, M. W.↗

Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter

The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavography prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Deployable Entry Placement Technology (ADEPT) Development for Small Sat Class Venus Missions

The Adaptable, Deployable Entry and Placement Technology (ADEPT) is a novel approach for entry vehicle design. Similar to an umbrella, it is stowed during launch and deployed prior to entry. ADEPT employs a high performance, 3-D woven, carbon fabric to serve as the primary surface of the mechanically deployed system. The successful ADEPT sounding rocket flight test matured the 1-meter Class ADEPT in the areas of deployment and structural integrity, and provided aerodynamic flight characteristics of the ADEPT open-back configuration from Mach 3 to Mach 0.3. Aerocapture uses the aerodynamic drag from a single hyperbolic atmospheric pass to provide the delta-V needed for orbit insertion. Studies suggest that, compared to propulsive orbit insertion, aerocapture could increase delivered payload by 70 percent at Venus. Drag modulation aerocapture, which shows promise of being simpler and more cost-effective than the more-often studied lift modulation methods, uses in-flight transformations of an entry vehicle's drag area to control the amount of deceleration produced during an atmospheric pass. In single-event drag modulation, a drag device is jettisoned after the appropriate deceleration. ADEPT, due to its unique ability to fold and unfold, is being considered for this SmallSat class payload mission applications.

Cassell, Alan M.↗

Radiation Characteristics of the FN-II Dense Plasma Focus Device

The Fuego Nuevo II (FN-II) dense plasma focus device is a small machine (4.6 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, in which neutrons, as well as soft and hard X rays have been studied with a number of diagnostics. Neutrons are studied with silver activation counters, and scintillator-photomultiplier detectors, while their angular distribution inside and outside the discharge chamber have been studied with CR-39 plastic track detectors. The soft X rays are studied with a multiple-pin-hole camera and PIN diodes, while the hard X-rays are observed with the scintillator-photomultiplier detectors mentioned above. When a needle is inserted on the inner electrode, a bright spot of hard x-rays can be concentrated, and used for the production of high-contrast radiography. Dosimetric measurements have been made for X-rays crossing a 300 micron aluminum window, through the axis of the machine, showing an average dose of 0.11{+-}0.01 mGy per shot. In contrast, the average dose with a hollow cathode is 0.077{+-}0.006 mGy per shot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single Center Experience with the AngioVac Aspiration System

PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and the patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Green (In,Ga,Al)P-GaP light-emitting diodes grown on high-index GaAs surfaces

We report on green (550–560 nm) electroluminescence (EL) from (Al{sub 0.5}Ga{sub 0.5}){sub 0.5}In{sub 0.5}P-(Al{sub 0.8}Ga{sub 0.2}){sub 0.5}In{sub 0.5}P double p-i-n heterostructures with monolayer-scale GaP insertions in the cladding layers and light-emitting diodes based thereupon. The structures are grown side-by-side on high-index and (100) GaAs substrates by molecular beam epitaxy. At moderate current densities (∼500 A/cm{sup 2}), the EL intensity of the structures is comparable for all substrate orientations. Opposite to the (100)-grown strictures, the EL spectra of (211) and (311)-grown devices are shifted towards shorter wavelengths (∼550 nm at room temperature). At high current densities (>1 kA/cm{sup 2}), a much higher EL intensity is achieved for the devices grown on high-index substrates. The integrated intensity of (311)-grown structures gradually saturates at current densities above 4 kA/cm{sup 2}, whereas no saturation is revealed for (211)-grown structures up to the current densities above 14 kA/cm{sup 2}. We attribute the effect to the surface orientation-dependent engineering of the GaP band structure, which prevents the escape of the nonequilibrium electrons into the indirect conduction band minima of the p-doped (Al{sub 0.8}Ga{sub 0.2}){sub 0.5}In{sub 0.5}P cladding layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-291: Sensitivity of a Simple 2D EPID in Vivo Dosimetry

Purpose: As radiotherapy (RT) increases in complexity, so does motivation for in vivo dosimetry (IVD), which may detect errors such as: setup, beam shaping and dose delivered. We have recently developed an easy-toimplement method for two-dimensional IVD based on images taken with the electronic portal imaging device (EPID) in cine mode during treatment. The purpose of this work is to characterize its sensitivity to possible RT delivery errors. Methods: We introduced a series of modifications to a simple RT field (10×10, 100MU, 300RR, 20cm homogeneous phantom) to simulate errors. These modifications included multi-leaf collimator (MLC) position, number of MUs, and collimator angle. We quantified the sensitivity to inhomogeneities by inserting variable amounts of solid lung and bone. Finally we delivered realistic fields to an anthropomorphic phantom to estimate sensitivity to gantry angle and setup errors. Results: Our EPIDIVD is sensitive to MLC positioning errors of 1mm and 3mm in the closed and open directions respectively, and to 3% MU variations. Sensitivity to collimator angle depends on field shape irregularity; in the case of a 10x10 field, we are sensitive to errors of 0.8°. The sensitivity to inhomogeneities is limited by the nature of MV imaging: approximately 1% signal change is noted when switching 5cm of water to equal amounts of bone or lung. This suggests that the EPID-IVD is likely not sensitive to small setup or gantry angle errors, as confirmed by anthropomorphic tests. Conclusion: We have characterized a simple method of 2D dose reconstruction at isocenter depth inside the patient, which is sensitive to possible RT delivery errors. This method may be useful as a secondary safety check, to prevent large errors from being carried on to following fractions, and to record delivered dose. By using readily available hardware, it is easily implemented and may prove especially useful in centers with limited resources.

60 APPLIED LIFE SCIENCES↗

Attitude and articulation control for CRAF/Cassini

The Comet Rendezvous/Asteroid Flyby (CRAF) and Cassini planetary missions provide exciting pointing and control challenges. The mission and science objectives, and an attitude and articulation control concept designed to meet these challenges, are described. CRAF/Cassini mission characteristics which drive pointing and control include: close range flybys of asteroids and icy satellites; Huygens probe guidance and communication; Saturn orbit insertion; comet rendezvous and orbit insertion; closed loop target tracking from a comet orbit perturbed by gas and dust pressure; fine spacecraft pointing for Titan radar mapping and Earth communications; requirements for autonomous failure detection; isolation; recovery; and 13.5 year lifetime. The philosophy and approach chosen to meet these challenges and the overall control architecture are addressed, including operational and autonomous safe modes. Critical functions are highlighted, such as charge coupled device imaging of stars and extended bodies which provide references for inertial and target referenced pointing respectively. Tradeoffs and rationale for the selection and location of sensors and actuators are reviewed.

Bell, C. E.↗

Evaluation and prediction of color-tunable organic light-emitting diodes based on carrier/exciton adjusting interlayer

A color tuning index (I{sub CT}) parameter for evaluating the color change capability of color-tunable organic light-emitting diodes (CT-OLEDs) was proposed and formulated. And a series of CT-OLEDs, consisting of five different carrier/exciton adjusting interlayers (C/EALs) inserted between two complementary emitting layers, were fabricated and applied to disclose the relationship between I{sub CT} and C/EALs. The result showed that the trend of electroluminescence spectra behavior in CT-OLEDs has good accordance with I{sub CT} values, indicating that the I{sub CT} parameter is feasible for the evaluation of color variation. Meanwhile, by changing energy level and C/EAL thickness, the optimized device with the widest color tuning range was based on N,N′-dicarbazolyl-3,5-benzene C/EAL, exhibiting the highest I{sub CT} value of 41.2%. Based on carrier quadratic hopping theory and exciton transfer model, two fitting I{sub CT} formulas derived from the highest occupied molecular orbital (HOMO) energy level and triplet energy level were simulated. Finally, a color tuning prediction (CTP) model was developed to deduce the I{sub CT} via C/EAL HOMO and triplet energy levels, and verified by the fabricated OLEDs with five different C/EALs. We believe that the CTP model assisted with I{sub CT} parameter will be helpful for fabricating high performance CT-OLEDs with a broad range of color tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peripheral white blood cells profile of biodegradable metal implant in mice animal model

Biocompatibility or safety of the medical device is considered important. It can be determined by blood profile examination. The aim of this study was to assess the biocompatibility of biodegradable metal implant through peripheral white blood cells (WBCs) profile approach. Forty eight male ddy mice were divided into four groups according to the materials implanted: iron wire (Fe), magnesium rod (Mg), stainless steel surgical wire (SS316L) and control with sham (K). Implants were inserted and attached onto the right femoral bone on latero-medial region. In this study, peripheral white blood cells and leukocyte differentiation were the parameters examined. The result showed that the WBCs value of all groups were decreased at the first day after implantation, increased at the 10th day and continued increasing at the 30th day of observation, except Mg group which has decreased. Neutrophil, as an inflammatory cells, was increased at the early weeks and decreased at the day-30 after surgery in all groups. Despite, these values during the observation were still within the normal range. As a conclus ion, biodegradable metal implants lead to an inflammatory reaction, with no adverse effect on WBC value found.

60 APPLIED LIFE SCIENCES↗

Absence of spin transport in the organic semiconductor Alq{sub 3}.

There have been differing interpretations regarding the magnetoresistance (MR) reported in spin-valve structures containing thick layers of the organic semiconductor tris-(8-hydroxyquinoline) aluminum (Alq{sub 3}). While some attribute it to spin injection and transport in Alq{sub 3}, others suggest tunneling through locally thin regions of the Alq{sub 3} layer as the mechanism. We present results of magnetotransport and charge transport measurements on Alq{sub 3}-based spin valves and unipolar devices where the Alq{sub 3} thickness is beyond the tunneling limit. We observe no measurable MR in the Fe/Alq{sub 3}/Co spin valve structures. Measurements of temperature-dependent current-voltage characteristics and comparisons with unipolar devices show that charge transport in Fe/Alq{sub 3}/Co spin valves is by holes only and is injection-limited. The hole-only transport in Alq{sub 3} is stable only at low current densities. This supports the tunneling interpretation of the earlier reported MR. Similar to inorganic semiconductors, the large conductivity mismatch between the metal electrodes and the organic semiconductor prevents spin injection. However, inserting a tunnel barrier between the magnetic electrode and the organic semiconductor did not improve spin injection.

36 MATERIALS SCIENCE↗

AI, automation and the Flight Telerobotic Servicer

A NASA study for the preliminary definition of a teleoperated robotic device has been recently completed. The Fligt Telerobotic Servicer (FTS) will be used to assist astronauts in many of the on-board tasks of assembly, maintenance, servicing, and inspection of the Space Station. The role of artificial intelligence (AI) in furthering the FTS automation capabilities and, hence, extending its capacity for growth and evolution is discussed. Relevant system engineering issues are identified, and an approach for insertion of AI technology is presented in terms of the NASA/NBS Standard Reference Model control architecture NASREM.

Goforth, Andre↗