Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOAD TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Multiaxial Fatigue Life Prediction Based on Nonlinear Continuum Damage Mechanics and Critical Plane Method

A new multiaxial fatigue life prediction model has been proposed in this paper. The concepts of nonlinear continuum damage mechanics and critical plane criteria were incorporated in the proposed model. The shear strain-based damage control parameter was chosen to account for multiaxial fatigue damage under constant amplitude loading. Fatigue tests were conducted on nickel-based superalloy GH4169 tubular specimens at the temperature of 400 °C under proportional and nonproportional loading. The proposed method was checked against the multiaxial fatigue test data of GH4169. Most of prediction results are within a factor of two scatter band of the test results.

36 MATERIALS SCIENCE↗

Vibration Testing of Electrical Cables to Quantify Loads at Tie-Down Locations

The standard method for defining static equivalent structural load factors for components is based on Mile s equation. Unless test data is available, 5% critical damping is assumed for all components when calculating loads. Application of this method to electrical cable tie-down hardware often results in high loads, which often exceed the capability of typical tie-down options such as cable ties and P-clamps. Random vibration testing of electrical cables was used to better understand the factors that influence component loads: natural frequency, damping, and mass participation. An initial round of vibration testing successfully identified variables of interest, checked out the test fixture and instrumentation, and provided justification for removing some conservatism in the standard method. Additional testing is planned that will include a larger range of cable sizes for the most significant contributors to load as variables to further refine loads at cable tie-down points. Completed testing has provided justification to reduce loads at cable tie-downs by 45% with additional refinement based on measured cable natural frequencies.

Dutson, Joseph D.↗

Load distribution on a close-coupled wing canard at transonic speeds

This paper reports on a wind-tunnel test where load distributions were obtained at transonic speeds on both the canard and wing surfaces of a closely-coupled wing-canard configuration. The investigation included detailed component and configuration arrangement studies to provide insight into the various aerodynamic interference effects for the leading-edge vortex flow conditions encountered. Data indicate that increasing the Mach number from 0.70 to 0.95 caused the wing leading-edge vortex to burst over the wing when the wing was in the presence of the high canard. For some of the outboard span locations, the leading-edge vortex reattachment streamline intersects the wing trailing edge inboard of these span locations, thus, the Kutta condition was not satisfied. In general, the effect of adding a canard was to reduce the lift inboard and somewhat increase the lift outboard similar to the trends that would have been expected had the flow been attached.

Gloss, B. B.↗

Deployable beam flight experiment (MAST)

Improvement of technology of space systems control is discussed. Future space systems such as large antennas or a space station may have dimensions on the order of 30 m to 200 m, yet their basic structures may be relatively lightweight and flexible, making ground tests for loads, controls analyses, and design verifications questionable if not impossible. Abandoning the extensive ground test and analysis verification program that led to the success of previous spacecraft is not a sensible option; making it meaningful using current technology will require inefficient, ultraconservative structure and control designs. New test methods are outlined.

Hanks, B. R.↗

Strength Tests of Thin-walled Duralumin Cylinders of Elliptic Section

This report is the fifth of a series presenting the results of strength tests of thin-walled cylinders and truncated cones of circular and elliptic section; it includes the results obtained from torsion tests on 30 cylinders, pure bending tests on 30 cylinders, and combined transverse shear and bending tests on 60 cylinders. All the cylinders tested were elliptic section with the ends clamped to rigid bulkheads. In the pure bending and combined transverse shear and bending tests the loads were applied in the plane of the major axis. The results of the tests on elliptic cylinders are correlated with the results of corresponding tests on circular cylinders and are presented in charts suitable for use in design.

STRESSED SKIN - CYLINDERS, ELLIPTIC - STRENGTH↗

Round Heat-treated Chromium-molybdenum-steel Tubing Under Combined Loads

The results of tests of round heat-treated chromium-molybdenum-steel tubing are presented. Tests were made on tubing under axial load, bending load, torsional load, combined bending and axial load, combined bending and torsional load, and combined axial, bending, and torsional load. Tensile and compressive tests were made to determine the properties of the material. Formulas are given for the evaluation of the maximum strength of this steel tubing under individual or combined loads. The solution of an example is included to show the procedure to be followed in designing a tubular cantilever member to carry combined loads.

Osgood, William R↗

Thermography Inspection for Early Detection of Composite Damage in Structures During Fatigue Loading

Advanced composite structures are commonly tested under controlled loading. Understanding the initiation and progression of composite damage under load is critical for validating design concepts and structural analysis tools. Thermal nondestructive evaluation (NDE) is used to detect and characterize damage in composite structures during fatigue loading. A difference image processing algorithm is demonstrated to enhance damage detection and characterization by removing thermal variations not associated with defects. In addition, a one-dimensional multilayered thermal model is used to characterize damage. Lastly, the thermography results are compared to other inspections such as non-immersion ultrasonic inspections and computed tomography X-ray.

Zalameda, Joseph N.↗

CO2-Binding Organic Liquids Gas Capture with Polarity-Swing-Assisted Regeneration Full Technology Feasibility Study B1 - Solvent-based Systems

PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600 cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present

Heldebrant, David J↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, J. J.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, Jessica J.↗

OC6 Project Phase IV: Validation of Numerical Models for Novel Floating Offshore Wind Support Structures

The fourth phase of the Offshore Code Comparison, Collaboration, Continued, with Correlation and unCertainty (OC6) aims to assess the ability of the tools to model a novel floating wind design. The design that was selected for this project is the TetraSpar designed by Stiesdal Offshore Technologies. The platform is a unique design that features a spar like stability with a very low center of gravity, but does not require deep-water ports. This combination is achieved with a system made of two separate steel structures, a hull at the water’s surface that supports the wind turbine tower, and a keel that is suspended below the main body. This lower keel has a very high density and drives the total platform’s low center of gravity. Scaled model tests of the TetraSpar design were performed in 2018-2019 by the University of Maine. The tests were performed with 1:43 Froude scaling. The data collected in the model tests provide a detailed description of the response of the platform in various controlled and relatively well understood conditions. Comparison with these data provides a good opportunity for validation of numerical models. The OC6 Phase IV work will focus on the specific parameters used in these scaled model tests. The load cases (LC) considered in this project are as follows: LC 1.X - Equilibrium and Static Offset Tests LC 2.X - Platform Free Decays LC 3.X - Turbine Thrust (Wind Only) LC 4.X - Regular and Irregular Waves (Wave only) LC 5.X - Combined Wind and Wave Loading

17 WIND ENERGY↗

Space fabrication demonstration system

The development effort on the composite beam cap fabricator was completed within cost and close to abbreviated goals. The design and analysis of flight weight primary and secondary beam builder structures proceeded satisfactorily but remains curtailed until further funding is made available to complete the work. The induction fastening effort remains within cost and schedule constraints. Tests of the LARC prototype induction welder is continuing in an instrumented test stand comprised of a Dumore drill press (air over oil feed for variable applied loads) and a dynamometer to measure actual welding loads. Continued testing shows that the interface screening must be well impregnated with resin to ensure proper flow when bonding graphite-acrylic lap shear samples. Specimens prepared from 0.030 inch thick graphite-polyethersulfone are also available for future induction fastening evaluation.

Source record↗

Avoiding unrealistic overtest by notching the vibration test specification

The test specifications for spacecraft and components permit test levels to be reduced under a procedure commonly referred to as notching. A summary is provided of the steps required to comply with the notching criterion. Primary structural loads are discussed along with aspect of mathematical modelling of the spacecraft structure, a launch loads analysis, a vibration test loads analysis, and notching methods. It is shown that current, general vibration test specifications are capable of producing unrealistically high spacecraft structural loads.

Hershfeld, D. J.↗

Design considerations for attaining 200-knot test velocities at the aircraft landing loads and traction facility

Design studies are presented which consider the important parameters in providing 200 knot test velocities at the landing loads and traction facility. Two major components of this facility, the hydraulic jet catapult and the test carriage structure, are considered. Suitable factors are determined to correlate analytical data for characteristics of the hydraulic jet catapult with data measured from the existing catapult system. The resulting equations are used to calculate test velocities for a range of jet nozzle diameters and carriage masses with both the current 122 m and an increased 183 m catapult stroke. Using the catapult characteristics, a target design point is selected and a carriage structure is sized to meet the target point strength requirements.

Giles, G. L.↗

Structural loads prediction in force-limited vibration testing

The purpose of this paper is to study whether the force limiting has accomplished the notching requirement to limit the equipment structural response in low frequency vibration tests to something less than the design load.

force limiting vibration testing flight limit load↗

Advanced composite aileron for L-1011 transport aircraft: Ground tests and flight evaluation

A composite aileron and a metal aileron were subjected to a series of comparative stiffness and vibration tests. These tests showed that the stiffness and vibration characteristics of the composite aileron are similar to the metal aileron. The first composite ground test article was statically tested to failure which occurred at 139 percent of design ultimate load. The second composite ground test article was tested to verify damage tolerance and fail-safe characteristics. Visible damage was inflicted to the aileron and the aileron was subjected to one lifetime of spectrum fatigue loading. After conducting limit load tests on the aileron, major damage was inflicted to the cover and the aileron was loaded to failure which occurred at 130 percent of design ultimate load. A shipset of composite ailerons were installed on Lockheed's L-1011 flight test aircraft and flown. The composite aileron was flutter-free throughout the flight envelope.

Griffin, C. F.↗

Handbook of structural stability part III : buckling of curved plates and shells

Available theories and test data on buckling of curved plates and shells are reviewed. For torsion and external-pressure loadings, the test data are correlated in terms of linear buckling theories for both the elastic and inelastic ranges. The cases which exhibit a marked disagreement between linear theory and test data include those of curved plates and cylinders under axial compression, cylinders under bending, and spherical plates under external pressure. These cases have been analyzed by a unified semiempirical approach for both the elastic and inelastic ranges which is satisfactory for analysis and design purposes. The effects of internal pressure on buckling of elements under uniaxial loads are discussed and data on various combined loadings are presented in interaction form. (author)

Gerard, George↗