SEARCH · Search NASA
Results for “Linear Technology”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Hilbert series, the Higgs mechanism, and HEFT
We expand Hilbert series technologies in effective field theory for the inclusion of massive particles, enabling, among other things, the enumeration of operator bases for non-linearly realized gauge theories. We find that the Higgs mechanism is manifest at the level of the Hilbert series, as expected for the partition function of an S-matrix that is subject to the Goldstone equivalence theorem. In addition to massive vectors, we detail how other massive, spinning particles can be studied with Hilbert series; in particular, we spell out the ingredients for massive gravity in general spacetime dimensions. Further methodology is introduced to enable Hilbert series to capture the effect of spurion fields acquiring vevs. We apply the techniques to the Higgs Effective Field Theory (HEFT), providing a systematic enumeration of its operator basis. This is achieved both from a direct and a custodial symmetry spurion-based approach; we compare and contrast the two approaches, and our results to those appearing in previous literature.
A Broadband Mechanically Tuned Superconducting Cavity Design Suitable for the Fermilab Main Injector
Radio Frequency superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab accelerator complex evolution initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.
SU-E-J-49: Design and Fabrication of Custom 3D Printed Phantoms for Radiation Therapy Research and Quality Assurance
Purpose The rapid proliferation of affordable 3D printing techniques has enabled the custom fabrication of items ranging from paper weights to medical implants. This study investigates the feasibility of utilizing the technology for developing novel phantoms for use in radiation therapy quality assurance (QA) procedures. Methods A phantom for measuring the geometric parameters of linear accelerator (LINAC) on-board imaging (OBI) systems was designed using SolidWorks. The design was transferred to a 3D printer and fabricated using a fused deposition modeling (FDM) technique. Fiducials were embedded in the phantom by placing 1.6 mm diameter steel balls in predefined holes and securing them with silicone. Several MV and kV images of the phantom were collected and the visibility and geometric accuracy were evaluated. A second phantom, for use in the experimental evaluation of a high dose rate (HDR) brachytherapy dosimeter, was designed to secure several applicator needles in water. The applicator was fabricated in the same 3D printer and used for experiments. Results The general accuracy of printed parts was determined to be 0.1 mm. The cost of materials for the imaging and QA phantoms were $22 and $5 respectively. Both the plastic structure and fiducial markers of the imaging phantom were visible in MV and kV images. Fiducial marker locations were determined to be within 1mm of desired locations, with the discrepancy being attributed to the fiducial attachment process. The HDR phantom secured the applicators within 0.5 mm of the desired locations. Conclusion 3D printing offers an inexpensive method for fabricating custom phantoms for use in radiation therapy quality assurance. While the geometric accuracy of such parts is limited compared to more expensive methods, the phantoms are still highly functional and provide a unique opportunity for rapid fabrication of custom phantoms for use in radiation therapy QA and research.
Experimental Demonstration of the Henon-Heiles Quasi-Integrable System at IOTA
The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. Its research program is focused on testing novel techniques for improving beam stability and quality, notably the concept of non-linear integrable optics. In this paper, we report the first results of experimental investigation of a quasi-integrable transverse focusing system with one invariant of motion, a Henon-Heiles type system implemented with octupole magnets. Good agreement with simulations is demonstrated on key parameters of achievable tune spread and dynamic aperture preservation. Resilience to perturbations and imperfections in the lattice is explored. We conclude by outlining future research plans and discussing applicability to future high intensity accelerators.
Experimental Studies of Single Invariant Quasi-Integrable Nonlinear Optics at IOTA
The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. Its research program is focused on testing novel techniques for improving beam stability and quality, notably the concept of non-linear integrable optics. In this paper, we report on run 1 results of experimental studies of a quasi-integrable transverse focusing system with one invariant of motion, a Henon-Heiles type system implemented with octupole magnets. Good agreement with simulations is demonstrated on key parameters of achievable tune spread, dynamic aperture, and invariant conservation. We also outline current simulation and hardware improvement efforts for run 2, planned for fall of 2019.
DOE SBIR 2014 Topic 2.C – Phase I Final Report
Freshwater is a vital resource for human survival as well as a key component of a wide range of industrial and agricultural needs. However, only 0.65% of the world’s water resources are available as freshwater, and the demand on the world’s water reserves continues to increase, with the demand beginning to outpace the supply in many areas. A water-energy nexus is being reached that requires low –cost and –energy solutions for various degrees of treated water. In a 2012 survey, 88% of Americans were concerned about potential water shortages and approximately two-thirds of the world’s population will be suffering a water shortage over the next few years. Seawater and other saline water materials make up around 98% of the available water, representing an almost unlimited supply of water. The energy, cost and maintenance to remove salts and other unwanted compounds is a barrier to widespread implementation of salt-to-freshwater facilities. These facilities most commonly use reverse osmosis (RO) systems. Due to the high required pressures and moving parts these facilities consume much grid energy and require constant maintenance leading to high capital and operational costs. RO also generates highly concentrated brine that is costly to safely return to the ocean. Capacitive desalination (or capacitive deionization [CDI]) has no moving parts (aside from a low pressure pump and valves), operates at low pressure and does not generate brine that is hazardous to marine life. Not only can the capacitive charge/discharge be cycled almost indefinitely but the system uses low energy and capacitive discharge electrical current can be co-generated back to the system. However, CDI has not seen widespread use for large- or small- scale desalination because electrode efficiency limits the extraction rate below what is useful for most applications. Mainstream Engineering Corporation (MEC) has demonstrated an innovative new electrode structure for the high efficiency desalination of brackish water by capacitive deionization. Electrode manufacturing (nanomanufacturing) is a highly scalable and low-cost electrochemical self-assembly method using a templated process that Mainstream has pioneered and leveraged for several energy technologies over the last decade. The primary accomplishment for Phase I is the fabrication and demonstration of CDI electrode structures are: • Demonstrating the linear scalability of templated approach to the fabrication scaling the electrode structure. • Demonstrated the ability to tune the fabrication of the electrode structures to produce electrodes with a highly controllable aligned nanopore diameter and nanopore depth. • Demonstrated the efficient removal of a sodium chloride salt from brackish water with a 60 times improvement in mg-salt removed/g-carbon compared to a commercial system under the same conditions. • Demonstrated good reproducibility and stability of the electrode structure under realistic CDI operating conditions. • Demonstrated charge efficiency as high as 93% with an expected system level energy requirement of 0.7 to 1.5 kWh/m3 of water; significantly lower than the 2.9 to 3.7 kWh/m3 observed for RO systems Based on the performance characteristics of the electrodes, Mainstream was able to propose a modular and scalable capacitive deionization design that can be adapted to a wide range of conditions providing energy efficient desalination of brackish water.
Development and Optimization of a Purification Process to Recover 99 Mo from Low-enriched Uranium
Supported by the DOE-NNSA Office of Material Management & Minimization (M3), a number of domestic entities are pursuing non-highly enriched uranium (non-HEU) production of 99 Mo. As the production technologies of 99Mo pivot toward low-enriched uranium (LEU) or molybdenum targets, new reaction channels and accelerators are being evaluated. Superconducting electron linear accelerators (LINACs) with high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that are capable of inducing photonuclear reactions and LEU fission. A particular advantage of a LINAC is that it does not rely on HEU-fueled reactor cores (which are currently slated for LEU conversion) and can operate on an almost continuous basis. Regarding the chemical purification of 99 Mo from irradiated uranium targets under acidic digestion, there exists a procedure known as Cintichem or modifications thereof with respect to LEU (LEU Modified Cintichem process, LMC). The process relies on a number of selective precipitation steps and column chromatography to purify Mo. It is important to note that LMC prescribes the addition of stable Mo to carry 99 Mo on alpha benzoin oxime, which reduces the specific activity of 99 Mo. This is especially important for processing 99 Mo batches with lower activities (~33 Ci of 99 Mo per batch).
A Mechanically Tuned Superconducting Main Injector Cavity
Radio Frequency (RF) superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab Accelerator Complex Evolution (ACE) initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.
Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft
A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.
Plasma-Material-Interaction Research Using PISCES Linear Plasma Devices
In this paper, recent plasma-material-interaction (PMI) studies of relevance to fusion PMI science are discussed. The results are a mix of science experiments and in situ diagnostic technology development. Scientific issues addressed include the nature of He and W atom migration in the evolution of W fuzz surfaces, understanding the nature of D retention in damaged W surfaces via modeling with the tritium migration and analysis program, and an examination of synergistic effects associated with D trapping on composite Be codeposit and W substrate surfaces. In situ diagnostic developments discussed include laser-induced desorption spectroscopy for the measurement of bulk hydrogen retention and laser-induced breakdown spectroscopy for the measurement of near-surface composition.
The Use of NASA Light-Emitting Diode Near-Infrared Technology for Biostimulation
Studies on cells exposed to microgravity and hypergravity indicate that human cells need gravity to stimulate growth. As the gravitational force increases or decreases, the cell function responds in a linear fashion. This poses significant health risks for astronauts in long-term spaceflight. The application of light therapy with the use of NASA LEDs will significantly improve the medical care that is available to astronauts on long-term space missions. NASA LEDs stimulate the basic energy processes in the mitochondria (energy compartments) of each cell, particularly when near-infrared light is used to activate the color sensitive chemicals (chromophores, cytochrome systems) inside. Optimal LED wavelengths include 680, 730 and 880 nm and our laboratory has improved the healing of wounds in laboratory animals by using both NASA LED light and hyperbaric oxygen. Furthermore, DNA synthesis in fibroblasts and muscle cells has been quintupled using NASA LED light alone, in a single application combining 680, 730 and 880 nm each at 4 Joules per centimeter squared. Muscle and bone atrophy are well documented in astronauts, and various minor injuries occurring in space have been reported not to heal until landing on Earth. An LED blanket device may be used for the prevention of bone and muscle atrophy in astronauts. The depth of near-infrared light penetration into human tissue has been measured spectroscopically.
Development of Advanced Instrumentation for Transient Testing
A fuel safety research program centered on in-pile transient testing experiments is being developed to support assessment and qualification of advanced nuclear fuel systems using the recently restarted Transient Reactor Test (TREAT) facility at the Idaho National Laboratory (INL). While resumption of transient testing at TREAT is crucial to enable these programs, full recovery and cutting-edge transient testing capability also requires a well-coordinated and innovative instrumentation development and qualification program to support near-term and future objectives. This paper summarizes the experimental approach of transient testing to focus on measuring the response of nuclear fuel to off-normal (or power-cooling mismatch) conditions for modern and advanced reactor environments requiring capabilities extending over wide measurement and environment conditions. It also highlights unique attributes of transient testing of importance to in-pile instruments including relatively low total neutron fluence, high gamma heating, and the need for well-defined and possibly short time response. Historical approaches to instrumentation for transient testing are also reviewed to provide context to the modern instrument strategy. The instrumentation needs of a modern transient testing are detailed while summarizing several ongoing R&D activities are supporting the development of state-of-the-art and ‘advanced’ measurement technologies that will provide baseline capability for Light Water Reactor (LWR) and Sodium-Cooled Fast Reactor (SFR) experiment objectives, while extending to other advanced reactor needs and advanced sensing technology opportunities. Examples of specific sensors planned for near-term deployment with ongoing development includes prompt-response self-powered neutron detectors (SPND), miniature fission chambers, optical-fiber-coupled infrared pyrometer, cladding surface thermocouples, electrical-impedance based boiling detector, and Linear Variable Differential Transformer (LVDT) based sensors for fuel elongation and pressure measurement.
Co-axial Joint Technology Applied to Antenna Backup Structures
The increasing demand to improve focusing accuracy and to accommodate higher frequencies in space communications and radio astronomy has created significant challenges for improving the capability of the constituent systems in radio antennas and telescopes. One important system is the radio antenna/telescope backup structure connections. The backup structure is a key element in providing a stable, precise and rigid support for the reflective surface. The ideal connection for these types of structures is rigid and concentric resulting in minimal deformation with stress/strain curves that are linear, repeatable and exhibiting no hysteresis over the entire service load range. Conceivably such a connection could be designed so that the stress/strain curve mimics the stress/strain characteristics of the connecting member in both tension and compression. When this is achieved then such joints can be said to be 'invisible' in the global behavior of the backup structure. At that point, overall reflector deflection becomes more linear and highly predictable. In conjunction with this advantage, optimized backup structure geometries, adaptive reflectors and compensating algorithms can best be applied in producing an instrument of unparalleled performance. This paper introduces Co-Axial Joint (CAJ) technology as the practical and economical means to produce an invisible connection.
Mechanisms of interfacial reactivity in near surface and extreme environments
The local water structure surrounding ions in aqueous solutions greatly affects their chemical properties such as reaction rates, ion association, and proton and electron transport. These properties result in the behavior of ions in natural aqueous environments. For example ore transport is facilitated by chloride ion pair formation and the reaction of ions in an interface is strongly dependent on the dehydration of the ion hydration shell. We are developing the use of high-resolution XAFS observations and 1st principles based MD-XAFS analysis (spectra simulated using 1st principle methods with no adjustable parameters, AIMD) to interpret the solution properties of strongly interacting aqueous solutes under arbitrary pressure and temperature conditions. In the 1st principle MD-XAFS method density functional theory (DFT) based MD simulations(Car and Parrinello, 1985) are used to generate a large ensemble of structural snap shots of the hydration region. These are then used to generate scattering intensities. I emphasize three points about this novel approach to analyzing XAFS data. 1st: As illustrated in Figure 1, the level of agreement between the calculated and observed intensities is considerably higher than has been obtained by any XAFS analysis to date (note 2nd shell region, R> 2 Å). 2nd: This result was obtained from a parameter free simulation with no fitting of the interaction potentials to any data. This supports the use of these methods for more difficult environments and more complex solutes (polyions). 3rd: New information about the shell structure (Figure 1) is now available because of this more detailed agreement. We note also that both multiple scattering and second shell features are well represented in the analysis. As far as we know this is the 1st analysis of second shell structure and multiple scattering. Excellent agreement has been obtained for most of the third row metal ions: Ca 2+ , Zn 2+ , Cu 2+ , Ni 2+ , Co 2+ , Mn 2+ , Fe 3+ , Cr 3+ . Calculations on these systems are demanding because of their open electronic shells, and high ionic charge. Principal Investigator: Professor John Weare (University of California, San Diego) The prediction of the interactions of geochemical fluids with minerals, nanoparticles, and colloids under extreme near surface conditions of temperature (T) and pressure (P) is a grand challenge research need in geosciences (U.S. DOE 2007, Basic Research Needs for Geosciences: Facilitating the 21st Energy Systems.). To evaluate the impact of these processes on energy production and management strategies it is necessary to have a high level of understanding of the interaction between complex natural fluids and mineral formations. This program emphasizes 1st principle parameter free simulations of complex chemical processes in solutions, in the mineral phase, and in the interfaces between these phases The development of new computational tools (with emphasis on oxide materials and reaction dynamics) tailored to treat wide range of conditions and time scales experienced in such geochemical applications is has been developed. Because of the sensitivity of the interaction in these systems to electronic structure and local bonding environments, and of the need to describe bond breaking/formation, our simulations are based on interactions calculated at the electronic structure level (ab-initio molecular dynamics, AIMD). The progress in the computational aspects of program may be summarized in terms of the following themes (objectives); Development of efficient parameter free dynamical simulation technology based on 1st principles force and energy calculations especially adapted for geochemical applications (e.g., mineral, interfaces and aqueous solutions) (continuing program); Calculation of the dynamics of water structure of in the surface-water interface of transition metal oxides and oxihydroxides; and Development of improved (beyond DFT+GGA) electronic structure calculations for minerals and the interface region that more accurately calculate electron correlation, spin density, and localization. The focus of the program is also on the iron oxide and oxihydroxide minerals and Fe 2+ (aq)/Fe 3+ (cr) oxidation in the mineral solution interface region. These methods included the development of model Hamilitonian methods that can be solved to near convergence for single site models (DMFT) and many-body perturbation methods (MP2, GW); Development of time decomposition methods to extend time scales of molecular dynamics (MD) simulations and support the use of high complexity electronic structure calculations (MP2, CCSD(T)) of forces for use in dynamical simulations where very high chemical accuracy is required (microsolvated reactions in absorbed surface layers); and The development of a new linear scaling finite element solver for eigenvalue problem that supports solution of quantum problems with unusual potential and boundary values. Application progress of the above new simulation technology to problems of geochemical interests includes; The prediction of metal oxide surface structure and the reduction/oxidation of Fe 3+ (cr)/Fe 2+ (aq) in metal oxide (hematite, goethite)/solution interfaces. Result: water interacts strongly with the 001 Hematite surface; interaction of water with the 100 goethite is weak; The study of ion solvation and the composition of ion hydration shells under extreme conditions (focus on Fe 3+/2+ , Al 3+ and Mg 2+ and their hydroxide speciation). Result: Ion association in water solutions can be calculated from 1st principle methods. Efficient sampling of the free energy requires more development; The continued development of new high resolution analysis of XAFS scattering of disordered systems (particularly Al, Mg) and of XANES calculations for aqueous ions. Result: EXAFS spectra can be calculated to high accuracy with DFT level dynamic simulations; The exploration of electron localization and electron transport in metal oxides (highly correlated materials). Result: Proper description of electron localization requires levels of calculation beyond DFT; and Localization of electrons in DFT type Hamiltonians was studied. Result: For very Dirac high exchange new solutions (New unphysical bifrucations) to the eigenvalue problem are found. The program was highly collaborative involving faculty and students in mathematics, physics and computer science departments as well as coworkers at the Pacific Northwest National Laboratories (PNNL). The students in this program had the opportunity to develop skills in the development of methods, the implementation of method on high performance parallel computers and the application of these methods to problem in geochemical science. Much of the software that was developed was incorporated in the NWchem software package maintained by PNNL.
Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays
The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.
BioSentinel: Mission Summary and Lessons Learned From the First Deep Space Biology CubeSat Mission
Launched on Artemis-1, BioSentinel carries a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft which included technologies newly developed or adapted for operations beyond Earth orbit. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation. This was the maiden deep-space voyage for many of the subsystems, and the first time to evaluate their performance in flight operation. Flying a CubeSat beyond LEO comes with unique challenges with respect to trajectory uncertainty and mission operations planning. The nominal plan was a lunar fly-by, followed by an insertion into Heliocentric orbit. However, some possible scenarios included lunar eclipses that could have severely impacted the power budget during that phase of the mission, while others could have resulted in a “Retrograde” hyperbola at swing-by resulting in the spacecraft traveling inward toward Earth or even towards a collision with the lunar surface. The commissioning phase of the mission was successful and completed a week ahead of schedule. It did not come without its exciting moments and challenges. First contact with the spacecraft uncovered that the vehicle was unexpectedly tumbling after deployment, a situation that needed to be corrected urgently. The mission operations team executed a contingency plan to stabilize the spacecraft, with just moments to spare before the battery ran out of power. The BioSensor payload onboard the spacecraft is a complex instrument that includes microfluidics, fluid systems, sensor control electronics, as well at the living yeast cells. BioSentinel also included a TimePix radiation sensor implemented by JSC’s RadWorks group. Dose and Linear Energy Transfer (LET) data is compared directly to the rate of DSB-and repair events measured by the S. cerevisiae cells. BioSentinel mature nanosatellite technologies included: deep space communications and navigation, autonomous attitude control and momentum management, and micro-propulsion systems, to provide an adaptable nanosatellite platform for deep space uses. This paper discusses the performance of the BioSentinel spacecraft through the mission phase, and includes lessons learned from challenges and anomalies. BioSentinel had many successes and will be a pathfinder for future deep space CubeSats and biology missions.
Biosentinel: Mission Summary and Lessons Learned From the First Deep Space Biology CubeSat Mission
Launched on Artemis-1, BioSentinel carries a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft which included technologies newly developed or adapted for operations beyond Earth orbit. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation. This was the maiden deep-space voyage for many of the subsystems, and the first time to evaluate their performance in flight operation. Flying a CubeSat beyond LEO comes with unique challenges with respect to trajectory uncertainty and mission operations planning. The nominal plan was a lunar fly-by, followed by an insertion into Heliocentric orbit. However, some possible scenarios included lunar eclipses that could have severely impacted the power budget during that phase of the mission, while others could have resulted in a “Retrograde” hyperbola at swing-by resulting in the spacecraft traveling inward toward Earth or even towards a collision with the lunar surface. The commissioning phase of the mission was successful and completed a week ahead of schedule. It did not come without its exciting moments and challenges. First contact with the spacecraft uncovered that the vehicle was unexpectedly tumbling after deployment, a situation that needed to be corrected urgently. The mission operations team executed a contingency plan to stabilize the spacecraft, with just moments to spare before the battery ran out of power. The BioSensor payload onboard the spacecraft is a complex instrument that includes microfluidics, fluid systems, sensor control electronics, as well at the living yeast cells. BioSentinel also included a TimePix radiation sensor implemented by JSC’s RadWorks group. Dose and Linear Energy Transfer (LET) data is compared directly to the rate of DSB-and repair events measured by the S. cerevisiae cells. BioSentinel mature nanosatellite technologies included: deep space communications and navigation, autonomous attitude control and momentum management, and micro-propulsion systems, to provide an adaptable nanosatellite platform for deep space uses. This paper discusses the performance of the BioSentinel spacecraft through the mission phase, and includes lessons learned from challenges and anomalies. BioSentinel had many successes and will be a pathfinder for future deep space CubeSats and biology missions.