WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matter in Extreme Conditions Instrument - Conceptual Design Report

The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by means of diffraction measurements, measurements of the pressure wave characteristics, in situ probing by x-ray scattering of various types all time resolved. The necessary diagnostics are discussed.

43 PARTICLE ACCELERATORS↗

Studies of Multipactor in Dielectric-Loaded Accelerator Structures: Comparison of Simulation Results with Experimental Data

In this paper new results of numerical studies of multipactor in dielectric-loaded accelerator structures are presented. The results are compared with experimental data obtained during recent studies of such structures performed by Argonne National Laboratory, the Naval Research Laboratory, SLAC National Accelerator Laboratory and Euclid TechLabs, LLC. Good agreement between the theory and experiment was observed for the structures with larger inner diameter, however the structures with smaller inner diameter demonstrated a discrepancy between the two. Possible reasons for such discrepancy are discussed.

43 PARTICLE ACCELERATORS↗

JRC-IRMM/ORNL Collaboration on Nuclear Data for Nuclear Criticality Safety - 14486

Concerns about using cross sections recommended in the main evaluated data libraries (i.e. ENDF/B, JEFF and JENDL) for nuclear criticality calculations have been a prime motivator for new cross section measurements. The measurements and evaluations discussed in this work are part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Institute for Reference Material and Measurements of the Joint Research Center (JRC-IRMM) of the European Commission (EC). They are performed in response to the US Nuclear Criticality Safety Program (NCSP) data needs. In particular, the NCSP five-year plan encompasses a listing of elements that have been identified for measurements and evaluations to address issues on criticality safety applications. This listing is based on data deficiency concerns in practical applications that are conveyed by criticality safety practitioners. In general these deficiencies are obtained through the analysis of benchmark calculations. A wealth of evaluations in the main libraries were derived from results of measurements made with poor time-of-flight resolution, and also the description of some data in the neutron energy range above several tens of keV is crude. This impacts both the resolved and unresolved resonance region, and leads to bias effects when resonance structures play an important role. As a consequence only average corrections can be applied in calculations for nuclear criticality calculations where self-shielding, multiple scattering, or Doppler broadening are important. This can lead to erroneous results. Furthermore, many evaluations for nuclides having small neutron-capture cross sections show erroneously high cross sections because the influence of the neutron sensitivity of the old measurement systems was underestimated. Although their neutron capture cross sections are small, these nuclides, if occurring in large amounts, can be important absorbers in criticality calculations, so an accurate determination of these cross sections is required. Over the last seven years the JRC-IRMM/ORNL collaboration has produced many neutron induced cross section data using the Geel Electron Linear Accelerator (GELINA) neutron time-of-flight facility. This facility is ideally suited to measure total, fission and capture cross sections in the energy range from 1 eV to ∼600 keV, which is important for nuclear criticality calculations. In this paper the facility and experimental set-ups at GELINA will be described together with the data reduction and analysis procedures which result in experimental observables including their full covariance information. The importance of combining transmission and partial cross section data will be emphasized. We will give a list of the measured nuclides and discuss the impact of the resulting data and evaluations. (authors)

42 ENGINEERING↗

MULTI-LEADER: MULTI-source LEarning-Accelerated Design of high-Efficiency multi-stage compRessor (Final Technical Report)

The objective of MULTI-LEADER is to cut design costs by 80% while generating more energy-efficient designs of multi-stage compressors by developing and implementing novel machine learning (ML) techniques, which enable faster and fewer design iterations, improved solver performance, and concurrent multi-disciplinary design. Current industrial practices for the design of multi-stage compressors involve simulation-based design optimization with successive levels of model fidelity, iteratively evaluated between distinct disciplines, one stage at a time to tackle the high dimensional design variations. This project addresses these key design challenges: (1) concurrent optimization of multiple stages under many non-linear constraints; (2) multitude of evaluation of high-fidelity and expensive solvers and their gradients during optimization convergence in high-dimensional design; (3) multi-disciplinary design to maximize aerodynamic performance while guaranteeing structural integrity and additive manufacturability; (4) utilization of multiple fidelity of solvers with disparate parameterization and modeling assumptions. MULTI-LEADER achieved more than 5x speed up in detailed design of more energy-efficient compressors via these machine learning (ML) innovations: (i) rapid design surrogates by multi-source learning from diverse fidelities across multiple disciplines, (ii) physics-constrained data-augmented modeling for improved empiricism, (iii) generative manifold embedding for high dimensional concurrent design without gradient information; (iv) budget-constrained fidelity-adaptive sampling towards fewer design iterations.

33 ADVANCED PROPULSION SYSTEMS↗

A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources

We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-344: Commissioning Constant Dose Rate VMAT in the Raystation Treatment Planning System for a Varian Clinac IX

Purpose: To demonstrate the commissioning of constant dose rate volumetric modulated arc therapy (VMAT) in the Raystation treatment planning system for a Varian Clinac iX with Exact couch. Methods: Constant dose rate (CDR) VMAT is an option in the Raystation treatment planning system, enabling VMAT delivery on Varian linacs without a RapidArc upgrade. Raystation 4.7 was used to commission CDR-VMAT for a Varian Clinac iX. Raystation arc model parameters were selected to match machine deliverability characteristics. A Varian Exact couch model was added to Raystation 4.7 and commissioned for use in VMAT optimization. CDR-VMAT commissioning checks were performed on the linac, including patient-specific QA measurements for 10 test patients using both the ArcCHECK from Sun Nuclear Corporation and COMPASS from IBA Dosimetry. Multi-criteria optimization (MCO) in Raystation was used for CDR-VMAT planning. Results: Raystation 4.7 generated clinically acceptable and deliverable CDR-VMAT plans for the Varian Clinac. VMAT plans were optimized including a model of the Exact couch with both rails in the out positions. CDR-VMAT plans generated with MCO in Raystation were dosimetrically comparable to Raystation MCO-generated IMRT plans. Patient-specific QA measurements with the ArcCHECK on the couch showed good agreement with the treatment planning system prediction. Patient-specific, structure-specific, multi-statistical parameter 3D QA measurements with gantry-mounted COMPASS also showed good agreement. Conclusion: Constant dose rate VMAT was successfully modeled in Raystation 4.7 for a Varian Clinac iX, and Raystation’s multicriteria optimization generated constant dose rate VMAT plans which were deliverable and dosimetrically comparable to IMRT plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-437: 3 Field VMAT Technique for Irradiation of Large Pelvic Tumors

Purpose: VMAT treatment planning for large pelvic volume irradiation could be suboptimal due to inability of Varian linac to split MLC carriage during VMAT delivery for fields larger than 14.5cm in X direction (direction of leaf motion). We compare the dosimetry between 3 VMAT planning techniques, two 2-arc field techniques and a 3-arc field technique: a) two small in X direction (less than 14.5cm) arc fields, complementing each other to cover the whole lateral extent of target during gantry rotation, b) two large arc fields, each covering the targets completely during the rotation, c) a 3 field technique with 2 small in X direction arcs and 1 large field covering whole target. Methods: 5 GYN cancer patients were selected to evaluate the 3 VMAT planning techniques. Treatment plans were generated using Varian Eclipse (ver. 11) TPS. Dose painting technique was used to deliver 5300 cGy to primary target and 4500 cGy to pelvic/abdominal node target. All the plans were normalized so that the prescription dose of 5300 cGy covered 95% of primary target volume. PTV and critical structures DVH curves were compared to evaluate all 3 planning techniques. Results: The dosimetric differences between the two 2-arc techniques were minor. The small field 2-arc technique showed a colder hot spot (0.4% averaged), while variations in maximum doses to critical structures were statistically nonsignificant (under 1.3%). In comparison, the 3-field technique demonstrated a colder hot spot (1.1% less, 105.8% averaged), and better sparing of critical structures. The maximum doses to larger bowel, small bowel and gluteal fold were 3% less, cord/cauda sparing was 4.2% better, and bladder maximum dose was 4.6% less. The differences in maximum doses to stomach and rectum were statistically nonsignificant. Conclusion: 3-arc VMAT technique for large field irradiation of pelvis demonstrates dosimetric advantages compared to 2-arc VMAT techniques.

60 APPLIED LIFE SCIENCES↗

Generalized parametrization methods for centroid and envelope dynamics of charged particle beams in coupled lattices

For almost 60 years, the well-known Courant-Snyder (CS) theory has been employed as the standard method to describe the uncoupled dynamics of charged particle beams in electromagnetic focusing lattices. Meanwhile, the generalization of the CS theory to coupled dynamics with two or more degrees of freedom has been attempted in numerous directions. The parametrization method developed by Qin and Davidson is particularly noteworthy, because their method enables the treatment of complicated coupled beam dynamics using a remarkably similar mathematical structure to that of the original CS theory. Here in this paper, we revisit the Qin-Davidson parametrization method and extend it to include beam centroid motions. The linear terms in the quadratic Hamiltonian for the coupled dynamics are handled by introducing a special time-dependent canonical transformation. In this manner, we show that the centroid dynamics is decoupled from the envelope dynamics, even for the cases of coupled lattice, and all formulations of the Qin-Davidson method can be applied in a straightforward manner.

43 PARTICLE ACCELERATORS↗

SU-G-201-14: Is Maximum Skin Dose a Reliable Metric for Accelerated Partial Breast Irradiation with Brachytherapy?

Purpose: To evaluate the reliability of the maximum point dose (Dmax) to the skin surface as a dosimetric constraint, we investigated the correlation between Dmax at the skin surface and dose metrics at various definitions of skin thickness. Methods: 42 patients treated with APBI using a Strut Adjusted Volume Implant (SAVI) applicator between 2010 and 2014 were retrospectively reviewed. Target (PTV-EVAL) and organs at risk (OARs: skin, lung, and ribs) were delineated on a CT following NSABP B-39 guidelines. Six skin structures were contoured: a rind 3cm external to the body surface and 1, 2, 3, 4, and 5mm thick rinds deep to the body surface. Inverse planning simulated annealing optimization was used to deliver 32–34Gy in 8-10 fractions to the target while minimizing OAR doses. Dmax, D0.1cc, D1.0cc, and D2.0cc to the various skin structures were calculated. Linear regressions between the metrics were evaluated using the coefficient of determination (R{sup 2}). Results: The average±SD PTV-EVAL volume and cavity-to-skin distances were 71.1±28.5cc and 6.9±5.0mm. The target V90 and V95 were 97.3±2.3% and 95.1±3.2%. The Dmax to the skin structures were 78.7±10.2% (skin surface), 82.2±10.7% (skin-1mm), 89.4±12.6% (skin-2mm), 97.9±15.4% (skin-3mm), 114.1±32.5% (skin-4mm), and 157.0±85.3% (skin-5mm). Linear regression analysis showed D1.0cc and D2.0cc to the skin 1mm and Dmax to the skin-4mm and 5mm were poorly correlated with other metrics (R{sup 2}=0.413±0.204). Dmax to the skin surface was well correlated (R{sup 2}=0.910±0.047) and D1.0cc to the skin-3mm was strongly correlated with all subsurface skin layers (R{sup 2}=0.935±0.050). Conclusion: Dmax to the skin surface is a relevant metric for breast skin dose. Contouring discontinuities in the skin with a 1mm subsurface rind and the active dwells in the skin 4 and 5mm introduced significant variations in skin DVH. D0.1cc, D1.0cc, and D2.0cc to a 3mm skin rind are more robust metrics in breast brachytherapy.

60 APPLIED LIFE SCIENCES↗

Testing the Delayed Gamma Capability in MCNP6

The mission of the Domestic Nuclear Detection Office is to quickly and reliably detect unauthorized attempts to import or transport special nuclear material for use against the United States. Developing detection equipment to meet this objective requires accurate simulation of both the detectable signature and detection mechanism. A delayed particle capability was initially added to MCNPX 2.6.A in 2005 to sample the radioactive fission product parents and emit decay particles resulting from the decay chain. To meet the objectives of detection scenario modeling, the capability was designed to sample a particular time for emitting particular multiplicity of a particular energy. Because the sampling process of selecting both time and energy is interdependent, to linearize the time and emission sampling, atom densities are computed at several discrete time steps, and the time-integrated production is computed by multiplying the atom density by the decay constant and time step size to produce a cumulative distribution function for sampling the emission time, energy, and multiplicity. The delayed particle capability was initially given a time-bin structure to help reasonably reproduce, from a qualitative sense, a fission benchmark by Beddingfield, which examined the delayed gamma emission. This original benchmark was only qualitative and did not contain the magnitudes of the actual measured data but did contain relative graphical representation of the spectra. A better benchmark with measured data was later provided by Hunt, Mozin, Reedy, Selpel, and Tobin at the Idaho Accelerator Center; however, because of the complexity of the benchmark setup, sizable systematic errors were expected in the modeling, and initial results compared to MCNPX 2.7.0 showed errors outside of statistical fluctuation. Presented in this paper is a more simplified approach to benchmarking, utilizing closed form analytic solutions to the granddaughter equations for particular sets of decay systems. We examine five different decay chains (two-stage decay to stable) and show the predictability of the MCNP6 delayed gamma feature. Results do show that while the default delayed gamma calculations available in the MCNP6 1.0 release can give accurate results for some isotopes (e.g., 137 Ba), the percent differences between the closed form analytic solutions and the MCNP6 calculations were often >40% ( 28 Mg, 28 Al, 42 K, 47 Ca, 47 Sc, 60 Co). With the MCNP6 1.1 Beta release, the tenth entry on the DBCN card allows improved calculation within <5% as compared to the closed form analytic solutions for immediate parent emissions and transient equilibrium systems. While the tenth entry on the DBCN card for MCNP6 1.1 gives much better results for transient equilibrium systems and parent emissions in general, it does little to improve daughter emissions of secular equilibrium systems. Finally, hypotheses were presented as to why daughter emissions of secular equilibrium systems might be mispredicted in some cases and not in others.

42 ENGINEERING↗

ANALYZING SURFACE ROUGHNESS DEPENDENCE OF LINEAR RF LOSSES

Topographic structure on Superconductivity Radio Frequency (SRF) surfaces can contribute additional cavity RF losses describable in terms of surface RF reflectivity and absorption indices of wave scattering theory. At isotropic homogeneous extent, Power Spectrum Density (PSD) of roughness is introduced and quantifies the random surface topographic structure. PSD obtained from different surface treatments of niobium, such Buffered Chemical Polishing (BCP), Electropolishing (EP), Nano-Mechanical Polishing (NMP) and Barrel Centrifugal Polishing (CBP) are compared. A perturbation model is utilized to calculate the additional rough surface RF losses based on PSD statistical analysis. This model will not consider that superconductor becomes normal conducting at fields higher than transition field. One can calculate the RF power dissipation ratio between rough surface and ideal smooth surface within this field range from linear loss mechanisms.

43 PARTICLE ACCELERATORS↗

Triangular flow in hydrodynamics and transport theory

In ultrarelativistic heavy-ion collisions, the Fourier decomposition of the relative azimuthal angle, {Delta}{phi}, distribution of particle pairs yields a large cos(3{Delta}{phi}) component, extending to large rapidity separations {Delta}{eta}>1. This component captures a significant portion of the ridge and shoulder structures in the {Delta}{phi} distribution, which have been observed after contributions from elliptic flow are subtracted. An average finite triangularity owing to event-by-event fluctuations in the initial matter distribution, followed by collective flow, naturally produces a cos(3{Delta}{phi}) correlation. Using ideal and viscous hydrodynamics and transport theory, we study the physics of triangular (v{sub 3}) flow in comparison to elliptic (v{sub 2}), quadrangular (v{sub 4}), and pentagonal (v{sub 5}) flow. We make quantitative predictions for v{sub 3} at RHIC and LHC as a function of centrality and transverse momentum. Our results for the centrality dependence of v{sub 3} show a quantitative agreement with data extracted from previous correlation measurements by the STAR collaboration. This study supports previous results on the importance of triangular flow in the understanding of ridge and shoulder structures. Triangular flow is found to be a sensitive probe of initial geometry fluctuations and viscosity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppressing Transverse Beam Halo with Nonlinear Magnetic Fields

High intensity proton storage rings are central for the development of advanced neutron sources, drivers for the production of pions in neutrino factories or muon colliders, and transmutation of radioactive waste. Fractional proton loss from the beam must be very small to prevent radioac- tivation of nearby structures, but many sources of beam loss are driven by collective effects that increase with intensity. Recent theoretical work on the use of nonlinear magnetic fields to design storage rings with integrable transverse dynamics is extended here to include collective effects, with numerical results showing validity in the presence of very high beam current. Among these effects is the formation of beam halo, where particles are driven to large amplitude oscillations by coherent space charge forces. The strong variation of particle oscillation frequency with amplitude results in nonlinear decoherence that is observed to suppress transverse halo development in the case studied. We also present a necessary generalization of the Kapchinskij-Vladimirskij equilibrium distribution, which was introduced over 50 years ago for modeling linear dynamics in particle accelerators.

43 PARTICLE ACCELERATORS↗

Monoenergetic Energy Doubling in a Hybrid Laser-Plasma Wakefield Accelerator

An ultracompact laser-plasma-generated, fs-scale electron double bunch system can be injected into a high-density driver/witness-type plasma wakefield accelerator afterburner stage to boost the witness electrons monoenergetically to energies far beyond twice their initial energy on the GeV scale. The combination of conservation of monoenergetic phase-space structure and fs duration with radial electric plasma fields E{sub r{approx}}100 GV/m leads to dramatic transversal witness compression and unprecedented charge densities. It seems feasible to upscale and implement the scheme to future accelerator systems.

43 PARTICLE ACCELERATORS↗

Magnetized Plasma-filled Waveguide: A New High-Gradient Accelerating Structure

Electromagnetic waves confined between the metal plates of a plasma-filled waveguide are investigated. It is demonstrated that when the plasma is magnetized along the metallic plates, there exists a luminous accelerating wave propagating with a very slow group velocity. It is shown that the magnetized plasma 'isolates' the metal wall from the transverse electric field, thereby reducing potential breakdown problems. Applications of the metallic plasma-filled waveguide to particle accelerations and microwave pulse manipulation are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating molecular property calculations with nonorthonormal Krylov space methods

Here, we formulate Krylov space methods for large eigenvalue problems and linear equation systems that take advantage of decreasing residual norms to reduce the cost of matrix-vector multiplication. The residuals are used as subspace basis without prior orthonormalization, which leads to generalized eigenvalue problems or linear equation systems on the Krylov space. These nonorthonormal Krylov space (nKs) algorithms are favorable for large matrices with irregular sparsity patterns whose elements are computed on the fly, because fewer operations are necessary as the residual norm decreases as compared to the conventional method, while errors in the desired eigenpairs and solution vectors remain small. We consider real symmetric and symplectic eigenvalue problems as well as linear equation systems and Sylvester equations as they appear in configuration interaction and response theory. The nKs method can be implemented in existing electronic structure codes with minor modifications and yields speed-ups of 1.2-1.8 in typical time-dependent Hartree-Fock and density functional applications without accuracy loss. The algorithm can compute entire linear subspaces simultaneously which benefits electronic spectra and force constant calculations requiring many eigenpairs or solution vectors. The nKs approach is related to difference density methods in electronic ground state calculations, and particularly efficient for integral direct computations of exchange-type contractions. By combination with resolution-of-the-identity methods for Coulomb contractions, three- to fivefold speed-ups of hybrid time-dependent density functional excited state and response calculations are achieved.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development and Comparison of an Artificial Gravity Concept for Human Spaceflight

Artificial Gravity (AG) for a long-duration space journey has been theorized since the dawn of human spaceflight. The purpose of this project is to begin bringing those concepts into real-life. The goal and primary study for this project is to research and understand the physics behind making a rotating centrifuge and the human limitations that may contribute to the design. The research first started with finding the physics equations we can use to calculate the rotational speed required for a certain gravity or the required radius for the centrifuge structure, this equation is a(sub c) = v2/r = w(sub c)2 r, where v is linear velocity, r is the radius of the structure, and is the rotational speed. Next, it is important to understand AG may be worthwhile because of the negative health effects of microgravity. The research then leads to finding human limitations in a rotating structure. The main limitation of a human living in this habitat is the Coriolis effect, which causes discomfort and motion sickness in the subject inside the structure, this causes the three semicircular fluid canals in your head that sense balance and motion. Finally, we use that knowledge to best hypothesize and propose the radius size for the structure that would negate the Coriolis effect, and using that we can calculate the appropriate rotational speed to get the desired gravity level, for example: 1 g or 9.81 m/s2 of acceleration. Overall this research can encourage increase knowledge in understanding AG, the physics and human limitation in a rotating centrifuge on future NASA long-duration Missions and Goals. This research can be a reference to future design proposals for long-duration exploration missions and colonization of planets or moons.

Cody L Beard↗