Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

High-resolution CH stretch spectroscopy of jet-cooled cyclopentyl radical: First insights into equilibrium structure, out-of-plane puckering, and IVR dynamics

First, high-resolution sub-Doppler infrared spectroscopic results for cyclopentyl radical (C 5 H 9 ) are reported on the α-CH stretch fundamental with suppression of spectral congestion achieved by adiabatic cooling to T rot ≈ 19(4) K in a slit jet expansion. Surprisingly, cyclopentyl radical exhibits a rotationally assignable infrared spectrum, despite 3N – 6 = 36 vibrational modes and an upper vibrational state density (ρ ≈ 40–90 #/cm –1 ) in the critical regime (ρ ≈ 100 #/cm –1 ) necessary for onset of intramolecular vibrational relaxation (IVR) dynamics. Such high-resolution data for cyclopentyl radical permit detailed fits to a rigid-rotor asymmetric top Hamiltonian, initial structural information for ground and vibrationally excited states, and opportunities for detailed comparison with theoretical predictions. Specifically, high level ab initio calculations at the coupled-cluster singles, doubles, and perturbative triples (CCSD(T))/ANO0, 1 level are used to calculate an out-of-plane bending potential, which reveals a C 2 symmetry double minimum 1D energy surface over a C 2v transition state. Here, the inversion barrier [V barrier ≈ 3.7(1) kcal/mol] is much larger than the effective moment of inertia for out-of-plane bending, resulting in localization of the cyclopentyl wavefunction near its C 2 symmetry equilibrium geometry and tunneling splittings for the ground state too small (<1 MHz) to be resolved under sub-Doppler slit jet conditions. The persistence of fully resolved high-resolution infrared spectroscopy for such large cyclic polyatomic radicals at high vibrational state densities suggests a “deceleration” of IVR for a cycloalkane ring topology, much as low frequency torsion/methyl rotation degrees of freedom have demonstrated a corresponding “acceleration” of IVR processes in linear hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing Cladded Components for High Temperature Nuclear Service: Part II—Design Rules

The challenge of using existing ASME Section III, Division 5, class A metallic materials for the construction of structural components of advanced reactors with corrosive coolants could be mitigated by allowing designers to use cladding to protect the base material from corrosion. However, the existing Section III, Division 5 rules provide no guidance on the evaluation of strain accumulation and creep-fatigue damage in cladded components. The availability of design rules for cladded components that do not require long-term clad material testing could promote the application of the cladding approach to accelerate the deployment schedule of these advanced reactor systems. To avoid long-term properties for the clad materials Part I of this work proposes two approximate design analysis methods for two types of clad materials—soft clads that creep much faster and have lower yield stress than the class A base material, and hard clads that creep much slower and have higher yield stress than the class A base material. The proposed analysis methods approximate the response of a soft clad by treating it as perfectly compliant and of a hard clad by treating it as linear elastic. Based on these approximate design analysis strategies this Part II develops a complete set of design rules for class A components cladded with either soft or hard clad materials. In conclusion, Part II discusses the reasoning behind the proposed design rules and uses example finite element analyses of representative reactor components to illustrate the use of these design methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transverse Beam Emittance Measurements of a 16 MeV Linac at the Idaho Accelerator Center

A beam emittance measurement of the 16 MeV S-band High Repetition Rate Linac (HRRL) was performed at Idaho State University's Idaho Accelerator Center (IAC). The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1 kHz. Measurements of the HRRL transverse beam emittance are underway that will be used to optimize the production of positrons using HRRL's intense electron beam on a tungsten converter. In this paper, we describe a beam imaging system using on an OTR screen and a digital CCD camera, a MATLAB tool to extract beamsize and emittance, detailed measurement procedures, and the measured transverse emittances for an arbitrary beam energy of 15 MeV.

43 PARTICLE ACCELERATORS↗

Thermal Analysis of SRF Cavity Couplers Using Parallel Multiphysics Tool TEM3P

SLAC has developed a multi-physics simulation code TEM3P for simulating integrated effects of electromagnetic, thermal and structural loads. TEM3P shares the same software infrastructure with SLAC's parallel finite element electromagnetic codes, thus enabling all physics simulations within a single framework. The finite-element approach allows high-fidelity, high-accuracy simulations and the parallel implementation facilitates large-scale computation with fast turnaround times. In this paper, TEM3P is used to analyze thermal loading at coupler end of the JLAB SRF cavity.

43 PARTICLE ACCELERATORS↗

Treatment planning for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Proposal for Study of Structure and Dynamics of Energy/Matter Based on Production of Gamma-Ray at SLAC Facility

The success of this proposal will open new areas of Chemistry with antimatter: (1) new chemical dynamics; (2) exclusive production of parent ions by energy-tuning the positrons; (3) formation of antimatter compounds; (4) nano- and microscopic imaging of molecules, cells, and tumors (5) multi-positron systems and their thermodynamics and chemical kinetics. Also with o-Ps and p-Ps physics including speculations of dark mater (PAMELA & ATIC reported excesses in the e{sup +}e{sup -} cosmic rays).

43 PARTICLE ACCELERATORS↗

Laser-IORT: a laser-driven source of relativistic electrons suitable for Intra-Operative Radiation Therapy of tumors

In a recent experiment [1] a high efficiency regime of stable electron acceleration to kinetic energies ranging from 10 to 40 MeV has been achieved. The main parameters of the electron bunches are comparable with those of bunches provided by commercial Radio-Frequency based Linacs currently used in Hospitals for Intra-Operative Radiation Therapy (IORT). IORT is an emerging technique applied in operating theaters during the surgical treatment of tumors. Performances and structure of a potential laser-driven Hospital accelerator are compared in detail with the ones of several commercial devices. A number of possible advantages of the laser based technique are also discussed.

43 PARTICLE ACCELERATORS↗

SU-F-T-81: Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculation

Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.

60 APPLIED LIFE SCIENCES↗

Analysis and Design of MEBT Beam Absorber for Project-X

A beam absorber is needed for a new high power accelerator to be built in Fermilab. It is called Project-X and should replace the existing linac and the 8 GeV Booster synchrotron. The beam absorber is part of the bunch-by-bunch chopper assigned to create an arbitrary bunch sequence required by experimental program. It will be located in the middle of the medium energy beam transport (MEBT) and has to remove the unnecessary bunches from the initially uniform bunch structure supplied by 2.1 MeV CW RFQ. At nominal RFQ beam current of 5 mA, the maximum power delivered to the beam absorber is about 10 kW. Beam optics requirements result in that the length allocated to the beam absorber is short ({approx}400 mm) and the beam size is small ({sigma}{approx}2mm). That yields high power density of the beam arriving to the absorber. The paper presents the thermal and mechanical analysis of one of proposed designs.

43 PARTICLE ACCELERATORS↗

High Pressure X-ray Diffraction Study of Titanium Disulfide

A high pressure angle dispersive synchrotron x-ray diffraction study of titanium disulfide (TiS2) was carried out to pressures of 45.5 GPa in a diamond-anvil cell. We observed a phase transformation of TiS2 beginning at about 20.7 GPa. The structure of the high pressure phase needs further identification. By fitting the pressure-volume data to the third-order Birch-Murnaghan equation of state, the bulk modulus, K0T, was determined to be 45.9 {+-} 0.7 GPa with its pressure derivative, K'0T, being 9.5 {+-} 0.3 at pressures lower than 17.8 GPa. It was found that the compression behavior of TiS2 is anisotropic along the different axes. The compression ratio of the c-axis is about nine times larger than the a-axis when pressures are lower than 1 GPa. It suddenly decreases to three times larger at pressures of about 3 GPa. This ratio shows a linear decrease with a slope of negative 0.048 at pressures below phase transformation.

43 PARTICLE ACCELERATORS↗

Nonlinear matter spectra in growing neutrino quintessence

We investigate the nonlinear power spectra of density perturbations and acoustic oscillations in growing neutrino quintessence. In this scenario, the neutrino mass has a strong dependence on the quintessence field. The induced coupling stops the evolution of the field when the neutrinos become nonrelativistic, and triggers the transition to the accelerating phase of the cosmological expansion. For the calculation of the nonlinear spectra we employ the time renormalization group, which resums subsets of diagrams of arbitrarily high order in cosmological perturbation theory. At redshifts around five, the neutrino fluctuations are still linear and acoustic oscillations are present in the neutrino power spectrum, induced by the acoustic oscillations in the baryonic and dark-matter sectors. The neutrino perturbations become nonlinear at redshifts around three. The mode coupling generated by the nonlinearities erases the oscillations in the neutrino spectrum at some redshift above two. There is a potential danger that at later times the influence of the gravitational potentials induced by the neutrino inhomogeneities could erase the oscillations from the baryonic and dark-matter spectra, making the scenario incompatible with observations. For the scenario to be viable, the neutrino-induced gravitational potentials in the range of baryon acoustic oscillations should not grow to average values much larger than 10{sup −4}. The magnitude of the expected potentials is still not known reliably, as the process of structure formation is poorly understood in growing neutrino quintessence. The time renormalization group cannot describe the effects of nonlinear clustering. Alternative methods, such as hydrodynamic simulations, must be empoloyed for the calculation of the spectra at low redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Recent Experiment on Wakefield Transformer Ratio Enhancement at AWA

One technique to enhance the transformer ratio beyond the ordinary limit of 2 in a collinear wakefield acceleration scheme is to use a ramped bunched train (RBT). The first experimental demonstration has been reported in [1]. However, due to the mismatch between the beam bunch length and frequency of the accelerating structure, the observed transformer ratio was only marginally above 2 in the earlier experiment. We recently revisited this experiment with an optimized bunch length using the laser stacking technique at Argonne Wakefield Accelerator (AWA) facility. A transformer ratio of 3.4 has been measured using two drive bunches. Attempting to use four drive bunches met with major challenges. In this article, measurement results and data analysis from these experiments are presented in detail.

43 PARTICLE ACCELERATORS↗

R&D ERL: HTS Solenoid

An innovative feature of the ERL project is the use of a solenoid made with High Temperature Superconductor (HTS) with the Superconducting RF cavity. The HTS solenoid design offers many advantages because of several unique design features. Typically the solenoid is placed outside the cryostat which means that the beam gets significantly defused before a focusing element starts. In the current design, the solenoid is placed inside the cryostat which provides an early focusing structure and thus a significant reduction in the emittance of the electron beam. In addition, taking full advantage of the high critical temperature of HTS, the solenoid has been designed to reach the required field at {approx}77 K, which can be obtained with liquid nitrogen. This significantly reduces the cost of testing and allows a variety of critical pre-tests which would have been prohibitively expensive at 4 K in liquid helium because of the additional requirements of cryostat and associated facilities.

43 PARTICLE ACCELERATORS↗

Accelerated Sequence Design of Star Block Copolymers: An Unbiased Exploration Strategy via Fusion of Molecular Dynamics Simulations and Machine Learning

Star block copolymers (s-BCPs) have potential applications as novel surfactants or amphiphiles for emulsification, compatibilization, chemical transformations, and separations. s-BCPs have chain architectures where three or more linear diblock copolymer arms comprised of two chemically distinct linear polymers, e.g., solvophobic and solvophilic chains, are covalently joined at one point. The chemical composition of each of the subunit polymer chains comprising the arms, their molecular weights, and the number of arms can be varied to tailor the surface and interfacial activity of these architecturally unique molecules. Further, this makes identification of the optimal s-BCP design nontrivial as the total number of plausible s-BCP architectures is experimentally or computationally intractable. In this work, we use molecular dynamics (MD) simulations coupled with a reinforcement learning-based Monte Carlo tree search (MCTS) to identify s-BCP designs that minimize the interfacial tension between polar and nonpolar solvents. We first validate the MCTS approach for the design of small- and medium-sized s-BCPs and then use it to efficiently identify sequences of copolymer blocks for large-sized s-BCPs. The structural origins of interfacial tension in these systems are also identified by using the configurations obtained from MD simulations. Chemical insights into the arrangement of copolymer blocks that promote lower interfacial tension were mined using machine learning (ML) techniques. Overall, this work provides an efficient approach to solve design problems via fusion of simulations and ML and provides important groundwork for future experimental investigation of s-BCPs for various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inclusive constraints on unified dark matter models from future large-scale surveys

In the very last years, cosmological models where the properties of the dark components of the Universe — dark matter and dark energy — are accounted for by a single ''dark fluid'' have drawn increasing attention and interest. Amongst many proposals, Unified Dark Matter (UDM) cosmologies are promising candidates as effective theories. In these models, a scalar field with a non-canonical kinetic term in its Lagrangian mimics both the accelerated expansion of the Universe at late times and the clustering properties of the large-scale structure of the cosmos. However, UDM models also present peculiar behaviours, the most interesting one being the fact that the perturbations in the dark-matter component of the scalar field do have a non-negligible speed of sound. This gives rise to an effective Jeans scale for the Newtonian potential, below which the dark fluid does not cluster any more. This implies a growth of structures fairly different from that of the concordance ΛCDM model. In this paper, we demonstrate that forthcoming large-scale surveys will be able to discriminate between viable UDM models and ΛCDM to a good degree of accuracy. To this purpose, the planned Euclid satellite will be a powerful tool, since it will provide very accurate data on galaxy clustering and the weak lensing effect of cosmic shear. Finally, we also exploit the constraining power of the ongoing CMB Planck experiment. Although our approach is the most conservative, with the inclusion of only well-understood, linear dynamics, in the end we also show what could be done if some amount of non-linear information were included.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor Fish: an autonomous sensor package for characterizing complex flow fields and fish passage

Fish passing through dams or other hydraulic structures may be injured or killed despite advances in turbine design, project operations, and other fish bypass systems. The Sensor Fish (SF) device is an autonomous sensor package that characterizes the physical conditions and stressors to which fish are exposed during passage through hydro facilities. It was designed to move passively as a neutrally buoyant object through severe hydraulic environments, while collecting high-resolution sensor data. Since its first generation1, the SF device has been successfully deployed in many fish passage studies and has evolved to be a major tool for characterizing fish passage conditions during fish passage in the Columbia River Basin. To better accelerate hydropower development, the U.S. Department of Energy Water Power Program provided funding to develop a new generation (Gen 2 SF) to incorporate more capabilities and accommodate a wider range of users over a broader range of turbine designs and operating environments. The Gen 2 SF (Figure 1) is approximately the size and density of a yearling salmon smolt and is nearly neutrally buoyant. It contains three-dimensional (3D) rotation sensors, 3D linear acceleration sensors, a pressure sensor, a temperature sensor, a 3D orientation sensor, a radiofrequency (RF) transmitter, and a recovery module2. A low-power microcontroller collects data from the sensors and stores up to 5 min of data on internal flash memory at a sampling frequency of 2048 Hz. The recovery module makes the SF positively buoyant after a pre-programmed period of time, causing it to float to the surface for recovery.

Sensor Fish↗

Observation of the {phi}(1680) and the Y(2175) in e{sup +}e{sup -}{yields}{phi}{pi}{sup +}{pi}{sup -}

The cross sections for e{sup +}e{sup -}{yields}{phi}{pi}{sup +}{pi}{sup -} and e{sup +}e{sup -}{yields}{phi}f{sub 0}(980) are measured from threshold to {radical}(s)=3.0 GeV using initial-state radiation. The analysis is based on a data sample of 673 fb{sup -1} collected on and below the {upsilon}(4S) resonance with the Belle detector at the KEKB asymmetric-energy e{sup +}e{sup -} collider. First measurements are reported for the resonance parameters of the {phi}(1680) in the {phi}{pi}{sup +}{pi}{sup -} mode: m=(1689{+-}7{+-}10) MeV/c{sup 2} and {gamma}=(211{+-}14{+-}19) MeV/c{sup 2}. A structure at {radical}(s)=2.1 GeV/c{sup 2}, corresponding to the so called Y(2175), is observed; its mass and width are determined to be (2079{+-}13{sub -28}{sup +79}) MeV/c{sup 2} and (192{+-}23{sub -61}{sup +25}) MeV/c{sup 2}, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗