Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Polar Lunar Regions: Exploiting Natural and Augmented Thermal Environments

In polar regions of the Moon, some areas within craters are permanently shadowed from solar illumination and can reach temperatures of 100 K or less. These regions could serve as cold traps, capturing ice and other volatile compounds. These potential ice stores have many applications for lunar exploration. Within double-shaded craters, even colder regions exist, with temperatures never exceeding 50 K in many cases. Observed temperatures suggest that these regions could enable equivalent liquid nitrogen cryogenic functions. These permanently shaded polar craters also offer unprecedented high-vacuum cryogenic environments, which in their current state could support cryogenic applications. Besides ice stores, the unique conditions at the lunar poles harbor an environment that provides an opportunity to reduce the power, weight, and total mass that needs to be carried from the Earth to the Moon for lunar exploration and research. Reducing the heat flux of geothermal, black body radiation can have significant impacts on the achievable temperature. With a few manmade augmentations, permanently shaded craters located near the lunar poles achieve temperatures even lower than those that naturally exist. Our analysis reveals that lightweight thermal shielding within shaded craters could create an environment several Kelvin above absolute zero. The temperature ranges of both naturally shaded and thermally augmented craters could enable the long-term storage of most gases, low-temperature superconductors for large magnetic fields, devices and advanced high-speed computing instruments. Augmenting thermal conditions in these craters could then be used as a basis for the development of an advanced thermal management architecture that would support a wide variety of cryogenically based applications. Lunar exploration and habitation capabilities would significantly benefit if permanently shaded craters, augmented with thermal shielding, were used to facilitate the operation of near absolute zero instruments, including a wide variety of cryogenically based propulsion, energy, communication, sensing, and computing devices. The required burden of carrying massive life-supporting components from the Earth to the Moon for lunar exploration and research potentially could be reduced.

Ryan, Robert E.↗

NASA's STEREO Mission

NASA's Solar-TErrestrial Relations Observatory mission, launched in 2006 October, consists of two nearly identical spacecraft in heliocentric orbits and currently 1380 of heliolongitude apart. Instrumentation on both spacecraft monitor solar wind plasma and magnetic field parameters, energetic particles, radio flux, and provide EUV and visible-light imaging of the corona, as well as novel, visible-light images of the ecliptic heliosphere. In addition to higher-resolution telemetry that enables a broad range of research into the propagation of disturbances in the inner heliosphere, a low-bandwidth, space weather beacon telemetry stream provides near-realtime information on each of these measurement types.

Gurman, Joseph B.↗

Europa Planetary Protection for Juno Jupiter Orbiter

NASA's Juno mission launched in 2011 and will explore the Jupiter system starting in 2016. Juno's suite of instruments is designed to investigate the atmosphere, gravitational fields, magnetic fields, and auroral regions. Its low perijove polar orbit will allow it to explore portions of the Jovian environment never before visited. While the Juno mission is not orbiting or flying close to Europa or the other Galilean satellites, planetary protection requirements for avoiding the contamination of Europa have been taken into account in the Juno mission design.The science mission is designed to conclude with a deorbit burn that disposes of the spacecraft in Jupiter's atmosphere. Compliance with planetary protection requirements is verified through a set of analyses including analysis of initial bioburden, analysis of the effect of bioburden reduction due to the space and Jovian radiation environments, probabilistic risk assessment of successful deorbit, Monte-Carlo orbit propagation, and bioburden reduction in the event of impact with an icy body.

Juno↗

Bar Code Events in the Juno-UVS Data: Signature ~10 MeV Electron Microbursts at Jupiter

One of the most intriguing discoveries of Juno is the quasi-systematic detection of upgoing electrons above the auroral regions. Here we discuss a by-product of the most energetic component of this population: a contamination resembling bar codes in the Juno-UVS images. This pattern is likely caused by bursts of ∼10 MeV electrons penetrating the instrument. These events are mostly detected when Juno’s magnetic footprint is located poleward of the main emission relative to the magnetic pole. The signal is not periodic, but the bursts are typically 0.1–1 s apart. They are essentially detected when Juno-UVS is oriented toward Jupiter, indicating that the signal is due to upgoing electrons. The event detections occur between 1 and 7 Jovian radii above the 1-bar level, suggesting that the electron acceleration takes place close to Jupiter and is thus both strong and brief.

Microbursts↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The plasma instrumentation for the Galileo Mission

The Galileo Mission's plasma instrumentation package encompasses a nested set of four spherical-plate electrostatic analyzers and three miniature magnetic mass spectrometers which identify the composition of the positive ion plasmas; the spectrometers' energy range is species-dependent. Two instrument microprocessors allow in-flight implementation of operational modes by ground command that are tailored for such specific regimes as the magnetosheath and the plasma sheet of the environs of Jupiter. Observational objectives include field-aligned currents, 3D ion bulk flows, Galilean satellite pickup ions, and the spatial distributions of plasmas.

Frank, L. A.↗

Instrument interface description for NOAA 2000 instruments with European morning spacecraft and/or NOAA-OPQ spacecraft

The purpose is to describe at a high level the common interface provisions and constraints placed on the NOAA-2000 instruments and the interfacing spacecraft elements in the following areas: electrical interface, mechanical interface, thermal interface, magnetic interface, electromagnetic compatibility, structural/mechanical environmental interface, contamination control, and the ionizing radiation environment. The requirements reflect the fact that these instruments must be compatible with a number of different polar orbiting satellite vehicles including the NOAA-OPQ satellites and the EUMETSAT METOP satellites.

Source record↗

A Novel In-situ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiation and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. Here, we aimed to develop an in-situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller.

47 OTHER INSTRUMENTATION↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

Radio Frequency Surface Impedance Characterization System for Superconducting Samples at 7.5 GHz

A radio frequency (RF) surface impedance characterization (SIC) system that uses a sapphire-loaded Nb cavity operating at 7.5 GHz has been fabricated to measure the RF surface impedance of flat superconducting samples. Currently, the SIC system can make direct calorimetric surface impedance measurements in the central 0.8 cm2 area of 5 cm diameter disk samples in a temperature range from 2 to 20 K, exposed to a magnetic flux density of up to 14 mT. As an application, we present the measurement results for a bulk Nb sample.

36 MATERIALS SCIENCE↗

A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVIDENCE OF THE SOLAR EUV HOT CHANNEL AS A MAGNETIC FLUX ROPE FROM REMOTE-SENSING AND IN SITU OBSERVATIONS

Hot channels (HCs), high-temperature erupting structures in the lower corona of the Sun, have been proposed as a proxy of magnetic flux ropes (MFRs) since their initial discovery. However, it is difficult to provide definitive proof given the fact that there is no direct measurement of the magnetic field in the corona. An alternative method is to use the magnetic field measurement in the solar wind from in situ instruments. On 2012 July 12, an HC was observed prior to and during a coronal mass ejection (CME) by the Atmospheric Imaging Assembly high-temperature images. The HC is invisible in the EUVI low-temperature images, which only show the cooler leading front (LF). However, both the LF and an ejecta can be observed in the coronagraphic images. These are consistent with the high temperature and high density of the HC and support that the ejecta is the erupted HC. Meanwhile, the associated CME shock was identified ahead of the ejecta and the sheath through the COR2 images, and the corresponding ICME was detected by the Advanced Composition Explorer, showing the shock, sheath, and magnetic cloud (MC) sequentially, which agrees with the coronagraphic observations. Further, the MC average Fe charge state is elevated, containing a relatively low-ionization-state center and a high-ionization-state shell, consistent with the preexisting HC observation and its growth through magnetic reconnection. All of these observations support that the MC detected near the Earth is the counterpart of the erupted HC in the corona for this event. The study provides strong observational evidence of the HC as an MFR.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

“Mirror” magnet experiment for quench studies, quench analysis techniques development and in support of superconducting magnet modeling

In order to progress on various research points related to superconducting magnets, we suggest performing series of tests with induced and natural quenches on a mirror magnet, probably using a “11 T” coil. The “mirror” is to have voltage taps instrumented on half the strands, on both coil ends. It is to be instrumented with multiple spot-heaters, of the order of ten, in designated pole-turn areas. Instrumentation is to include quench antenna array facing the inner coil surface, as well as acoustic sensors on the inner layer pole. Further, acoustic sensors at the magnet ends and an acoustic calibration transducer are to be installed. Thus, we are to test sensitivity and precision of acoustic and quench antenna (QA) array sensors, both at close proximity to the coil, and we are to test and commission acoustic on-magnet real-time “calibration”. New or extended DAQ will be tested as well. In addition to diagnostic development, the purpose of the magnet experiment is to investigate current redistribution in the coil, both during quenching and in operating conditions; to assess voltage build up across strands and in the coil segments during quenching, to explore voltage signature differentiation between different type of quenches; to improve modeling of processes during quenching and for magnet design purposes. In this experiment, we expect to be able to characterize the processes during a quench in unprecedented details.

43 PARTICLE ACCELERATORS↗