Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Molecular Level Structure and Dynamics of Electrolytes Using 17O Nuclear Magnetic Resonance Spectroscopy

Electrolytes help harness the energy from electrochemical processes by serving as solvents and transport media for redox-active ions. Molecular-level interactions between ionic solutes and solvent molecules – commonly referred to as solvation phenomena – give rise to many functional properties of electrolytes such as ionic conductivity, viscosity, and stability. It is critical to understand the evolution of solvation phenomena as a function of competing counterions and solvent mixtures to predict and design the optimal electrolyte for a target application. Probing oxygen environments is of great interest as oxygens are located at strategic molecular sites in battery solvents and are directly involved in inter- and intramolecular solvation interactions. NMR signals from 17O nuclei in battery electrolytes offer nondestructive bulk measurements of isotropic shielding, electric field gradient tensors, and transverse and longitudinal relaxation rates, which are excellent means for probing structure, bonding, and dynamics of both solute and solvent molecules. This article describes the use of 17O NMR spectroscopy in probing the solvation structures of various electrolyte systems ranging from transition metal ions in aqueous solution to lithium cations in organic solvent mixtures.

Environmental Molecular Sciences Laboratory↗

Nuclear Magnetic Resonance ‐based fragment screen of the E3 ligase Fem‐1 homolog B

Abstract Targeted protein degradation using PROTACs (PROteolysis TArgeting Chimeras) has emerged as a transformative therapeutic strategy, largely relying on a small number of E3 ubiquitin ligases such as CRBN and VHL. However, resistance, toxicity, and poor oral bioavailability limit the utility of PROTACs and highlight the need to expand the E3 ligase toolbox. Fem‐1 homolog B (FEM1B) is a lesser‐known E3 ligase that offers a promising alternative due to its broad expression and ability to recognize diverse degron motifs. Here, we describe the development of a stable construct of FEM1B, the results of a protein‐observed NMR‐based fragment screen using this construct, and the X‐ray structures of some of the fragment hits when bound to the protein. From these results, new PROTACs utilizing FEM1B as the E3 ligase may be discovered, providing an alternative E3 ligase for targeted protein degradation.

Katinas, Jade M. [Department of Biochemistry Vande↗

Optimal lexicon of gadoxetic acid-enhanced magnetic resonance imaging for the diagnosis of hepatocellular carcinoma modified from LI-RADS

Purpose: To define the optimal lexicon of major imaging findings on gadoxetic acid-enhanced MRIs to diagnose HCC to improve diagnostic performance of the LI-RADS. Methods: Two hundred forty-one hepatic lesions (149 HCC, six other malignancies, 86 benign lesions) in 177 treatment-naïve patients at risk of HCC who underwent gadoxetic acid-MRIs from January 2013 to December 2015 were retrospectively reviewed using either histopathological or follow-up imaging findings as a standard reference. Two board-certified radiologists independently evaluated the imaging features and categorized the nodules based on the original and the following modified definitions in LI-RADS: (1) washout appearance in the portal venous phase (PVP) only versus that in the PVP or transitional phase, and (2) enhancing capsule only versus enhancing or non-enhancing capsule. Diagnostic performance and inter-observer agreement of LR-5 were assessed and compared between the algorithms using generalized estimation equation. Results: The sensitivity [79.2% (95% confidence interval 71.9, 85.0)] and accuracy [84.6% (79.5, 88.7)] of LR-5 were significantly higher for modified lexicon compared with original LI-RADS [60.4% (52.3, 67.9) and 73.9% (67.9, 79.0); P < 0.001 in all cases]. There was no significant difference in specificity [93.5% (86.2, 97.0) and 95.7% (89.0, 98.4); P = 0.153]. Subgroups of lesions < or ≥ 2 cm showed similar tendencies. Inter-observer agreement for capsule appearance was fair to moderate, whereas that for other imaging findings was good to excellent. Conclusions: Compared to original LI-RADS, LI-RADS with modified lexicon showed higher sensitivity for the diagnosis of HCC using gadoxetic acid-MRI, with similar specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracranial Aneurysms Treated by Flow-Diverting Stents: Long-Term Follow-Up with Contrast-Enhanced Magnetic Resonance Angiography

PurposeLong-term data on aneurysm treatment with flow-diverting stents are still sparse, and follow-up protocols differ widely between institutions. We present long-term results, with a focus on the usefulness of contrast-enhanced MR angiography (ceMRA).Materials and MethodsInterventions and follow-up imaging of patients with aneurysms treated by flow-diverting stents (“Pipeline,” “Silk” and “FRED” models) without additional coiling were analyzed. All MRI scans included dedicated two-phase ceMRA. Aneurysm occlusion rates, size of the aneurysmal sac and complications were evaluated on MRI and digital subtraction angiography (DSA), where available. The ability of ceMRA to depict aneurysm occlusion and stent patency was graded on a three-point scale.ResultsTwenty-five patients with 102 MRI scans were included. The median duration of follow-up was 830 days. Aneurysm occlusion rates were 52% at 3 months (10 of 19 patients), 72% at 6 months (18/25) and 84% overall (21/25). Shrinkage of the aneurysmal sac was found in 19 patients (76%) and in 12 cases to <50% of the original size (48%). CeMRA assessability of aneurysmal occlusion was graded as good in all cases. When compared to DSA (18 cases), ceMRA had a sensitivity of 100% and specificity of 91% regarding aneurysm remnant detection. Assessability of the stent lumen varied and was limited in most cases.ConclusionsFlow-diverter treatment achieves high occlusion rates and can cause major aneurysm shrinkage. CeMRA is highly valuable regarding imaging of the aneurysmal sac. There are limitations regarding the assessability of the stent lumen on ceMRA. Level of Evidence: Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Gland Prostate Cancer Cryoablation with Magnetic Resonance Imaging Guidance: One-Year Follow-Up

PurposePatients who develop prostate cancer after prior abdominal perineal resection are poor surgical candidates, and have limited treatment options. Therefore, our goal is to present results from a single institutional experience of four patients who underwent whole gland MRI-guided cryoablation with a history complicated by prior abdominoperineal resection.Materials and MethodsFour MRI-guided cryoablative treatments (mean age 64, range 59-69 years) for primary and locally recurrent prostate adenocarcinoma were retrospectively reviewed in patients with prior abdominal perineal resection for colorectal cancer (3) and juvenile polyposis (1). Average prostate volume prior to ablation was 23 cc, with an average PSA of 5.6 ng/mL. For each gland, 7-10 cryoprobes were placed approximately 0.5 cm apart in the prostate gland under MRI guidance by a transperineal approach with 3-4 freeze-thaw cycles performed. Each patient had follow up imaging and PSA measurements out to 12 months post ablation.ResultsAll four patient’s PSA dropped below 0.1 ng/mL at 3-6 month post-ablation and remained at these levels at 12 months. Three of the 4 patients had PSA measurements to 33 months post-ablation, with no evidence of recurrence. No patient developed urinary incontinence due to the whole gland cryoablation.ConclusionWith all four patients in our study having undetectable PSAs 12 months post ablation, and with no patient developing urinary incontinence due to the cryoablation, MRI-guided cryoablation appears to be a promising treatment option in patients who are poor surgical candidates due to prior pelvic surgery and/or radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GPU-accelerated denoising of 3D magnetic resonance images

The raw computational power of GPU accelerators enables fast denoising of 3D MR images using bilateral filtering, anisotropic diffusion, and non-local means. In practice, applying these filtering operations requires setting multiple parameters. This study was designed to provide better guidance to practitioners for choosing the most appropriate parameters by answering two questions: what parameters yield the best denoising results in practice? And what tuning is necessary to achieve optimal performance on a modern GPU? To answer the first question, we use two different metrics, mean squared error (MSE) and mean structural similarity (MSSIM), to compare denoising quality against a reference image. Surprisingly, the best improvement in structural similarity with the bilateral filter is achieved with a small stencil size that lies within the range of real-time execution on an NVIDIA Tesla M2050 GPU. Moreover, inappropriate choices for parameters, especially scaling parameters, can yield very poor denoising performance. To answer the second question, we perform an autotuning study to empirically determine optimal memory tiling on the GPU. The variation in these results suggests that such tuning is an essential step in achieving real-time performance. These results have important implications for the real-time application of denoising to MR images in clinical settings that require fast turn-around times.

97 MATHEMATICS AND COMPUTING↗

Na and Li ion diffusion in modified ASTM C 1260 test by Magnetic Resonance Imaging (MRI)

In the current study, MRI was applied to investigate lithium and sodium ion diffusion in cement paste and mortars containing inert sand and borosilicate glass. Paste and mortars were treated by complying with ASTM C 1260. Lithium and sodium distribution profiles were collected at different ages after different treatments. Results revealed that sodium ions had a greater diffusion rate than lithium ions, suggesting that Na reaches the aggregate particle surface before Li. Results also showed that Na and Li ions had a competitive diffusion process in mortars; soaking in a solution with higher [Li] favored Li diffusion but hindered Na diffusion. In mortars containing glass, a substantial amount of Li was consumed by the formation of ASR products. When [Li] in soaking solution was reduced to 0.37 N, a distinctive Na distribution profile was observed, indicating the free-state Na ions were continuously transformed to solid reaction products by ASR. Hence, in the modified ASTM C 1260 test, [Li] in the storage solution should be controlled at 0.74 N, in order to completely prevent the consumption of Na ions and thus stop ASR.

36 MATERIALS SCIENCE↗

Diffusion-Weighted Magnetic Resonance Imaging to Evaluate Major Salivary Gland Function Before and After Radiotherapy

Purpose: To evaluate diffusion-weighted (DW)-MRI as a noninvasive tool to investigate major salivary gland function before and after radiotherapy (RT) for head and neck cancer (HNC). Methods and Materials: DW-MRI was performed in 8 HNC patients before and after parotid-sparing RT (mean dose to the contralateral parotid gland <26 Gy). A DW sequence was performed once at rest and then repeated continuously during salivary stimulation. Apparent diffusion coefficient (ADC) maps for both parotid and submandibular glands were calculated. Findings were compared with salivary gland scintigraphy. Results: Before RT, the mean ADC value at rest was significantly lower in the parotid than in the submandibular glands. During the first 5 min of stimulation, the ADC value of the salivary glands showed a decrease, followed by a steady increase until a peak ADC, significantly higher than the baseline value, was reached after a median of 17 min. The baseline ADC value at rest was significantly higher after RT than before RT in the nonspared salivary glands but not in the spared parotid glands. In the contralateral parotid glands, the same response was seen as before RT. This pattern was completely lost in the nonspared glands. These results corresponded with remaining or loss of salivary function, respectively, as confirmed by salivary gland scintigraphy. Conclusions: Diffusion-weighted-MRI allows noninvasive evaluation of functional changes in the major salivary glands after RT and is a promising tool for investigating radiation-induced xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗