Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

NanoSIMS STUDIES OF SMALL PRESOLAR SiC GRAINS: NEW INSIGHTS INTO SUPERNOVA NUCLEOSYNTHESIS, CHEMISTRY, AND DUST FORMATION

We have studied more than 2000 presolar silicon carbide (SiC) grains from the Murchison CM2 chondrite in the size range 0.2-0.5 {mu}m for C- and Si-isotopic compositions. In a subset of these grains, we also measured N-, Mg-Al-, S-, and Ca-Ti-isotopic compositions as well as trace element concentrations. The overall picture emerging from the isotope data is quite comparable with that of larger grains, except for the abundances of grains from Type II supernovae (SNeII) and low-metallicity asymptotic giant branch (AGB) stars. Especially, the latter are much more abundant among submicrometer-sized grains than among micrometer-sized grains. This implies that SiC grains from lower-than-solar-metallicity AGB stars are on average smaller than those from solar metallicity AGB stars which provided the majority of presolar SiC grains. We identified five grains with large enrichments in {sup 29}Si (up to 3.5x solar) and {sup 30}Si (up to 3.9x solar in three of these grains). These grains are most likely from SNeII. The isotopically light S ({sup 32}S/{sup 34}S of 2x solar) together with the heavy Si in one of these grains suggests that molecule formation precedes macroscopic mixing and dust formation in SNII ejecta. This adds to the complexity of SN mixing calculations and should be considered in future studies. In total, about 2% of the presolar SiC grains in the size range 0.2-0.5 {mu}m appear to come from SNeII. This is about a factor of 2 higher than for micrometer-sized grains and suggests that SNeII, on average, produce smaller SiC grains than solar metallicity AGB stars. The high {sup 29}Si/{sup 30}Si ratio in one of the SN grains suggests that current SN models underestimate the {sup 29}Si production in the C- and Ne-burning regions by about a factor of 2. It is shown that with this adjustment the solar {sup 29}Si/{sup 28}Si ratio can be well reproduced in Galactic chemical evolution models and that a merger of our Galaxy with a low-metallicity satellite some 1.5 Gyr before solar system formation could account for the slope 1.3 of the Si mainstream line.

79 ASTRONOMY AND ASTROPHYSICS↗

The nontrivial effects of annealing on superconducting properties of Nb single crystals

The effect of annealing on the superconducting properties of niobium single crystals was studied using optical, magnetic, and scanning tunneling microscopy (STM) methods. Pieces of the same crystal boule were studied before and after the annealing at 800 ${^\circ}\textrm{C}$, 1400 ${^\circ}\textrm{C}$, and near the melting point of niobium (2477 ${^\circ}\textrm{C}$). The initial samples had a high hydrogen content and low-temperature imaging revealed large hydrides (hundreds of micrometers) appearing below 190 K. The formation of these large precipitates is already completely suppressed by annealing at 800 ${^\circ}\textrm{C}$. However, the overall superconducting properties of the annealed samples did not improve and, in fact, worsened. In particular, the superconducting transition temperature decreased, the upper critical field increased, and the pinning strength increased. In the STM study, the sample was annealed initially at 400 ${^\circ}\textrm{C}$, measured, annealed at 1700 ${^\circ}\textrm{C}$, and measured again. The STM revealed a ‘dirty’ superconducting gap with a significant spatial variation in tunneling conductance after annealing at 400 ${^\circ}\textrm{C}$. The clean gap was recovered after annealing at 1700 ${^\circ}\textrm{C}$. This is likely due to oxygen redistribution near the surface, which is always covered by oxide layers in as-grown crystals. Our results indicate that vacuum annealing at least up to 1400 ${^\circ}\textrm{C}$, while removing a large percentage of hydrogen, introduces additional nanosized defects, likely hydride precipitates, that act as efficient pair-breaking and pinning centers. The dimensionless scattering rate is estimated to have increased from $\Gamma = 0.2$ to about $\Gamma = 0.4$ after annealing at 1400 ${^\circ}\textrm{C}$. These results on single crystals differ drastically from those obtained in polycrystalline bulk niobium (i.e. cut from superconducting radio-frequency cavities), where annealing is known to have a significant positive effect that is attributed to the improvement of the crystalline structure masking the more subtle influence of the hydrides.

43 PARTICLE ACCELERATORS↗

Coherent hard x-ray diffractive imaging of nonisolated objects confined by an aperture

Coherent hard x-ray imaging of nonisolated weak phase objects is demonstrated by confining x-ray beam in a region of a few micrometers in cross section using a micrometer-sized aperture. Two major obstacles in the hard x-ray coherent diffraction imaging, isolating samples and obtaining central speckles, are addressed by using the aperture. The usefulness of the proposed method is illustrated by reconstructing the exit wave field of a nanoscale trench structure fabricated on silicon which serves as a weak phase object. The quantitative phase information of the exit wave field was used to reconstruct the depth profile of the trench structure. The scanning capability of this method was also briefly discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlated polarization switching in the proximity of a 180° domain wall

Domain-wall dynamics in ferroic materials underpins functionality of data storage and information technology devices. Using localized electric field of a scanning probe microscopy tip, we experimentally demonstrate a surprisingly rich range of polarization reversal behaviors in the vicinity of the initially flat 180{sup o} ferroelectric domain wall. The nucleation bias is found to increase by an order of magnitude from a two-dimensional (2D) nucleus at the wall to three-dimensional nucleus in the bulk. The wall is thus significantly ferroelectrically softer than the bulk. The wall profoundly affects switching on length scales on the order of micrometers. The mechanism of correlated switching is analyzed using analytical theory and phase-field modeling. The longrange effect is ascribed to wall bending under the influence of a tip with bias that is well below the bulk nucleation level at large distances from the wall. These studies provide an experimental link between the macroscopic and mesoscopic physics of domain walls in ferroelectrics and atomistic models of 2D nucleation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging the magnetic nanodomains in Nd 2 Fe 14 B

Here, we study magnetic domains in Nd 2 Fe 14 B single crystals using high resolution magnetic force microscopy (MFM). Previous MFM studies and small angle neutron scattering experiments suggested the presence of nanoscale domains in addition to optically detected micrometer-scale ones. We find, in addition to the elongated, wavy nanodomains reported by a previous MFM study, that the micrometer-sized, star-shaped fractal pattern is constructed of an elongated network of nanodomains ~20 nm in width, with resolution-limited domain walls thinner than 2 nm. While the microscopic domains exhibit significant resilience to an external magnetic field, some of the nanodomains are sensitive to the magnetic field of the MFM tip.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray microdiffraction analysis of radiation-induced defects in single grains of polycrystalline Fe.

Single-crystal diffuse X-ray scattering was used to characterize radiation-induced defects in individual grains of a polycrystalline proton-irradiated Fe foil. The grains were probed with an intense 1 {micro}m X-ray beam to demonstrate that both polycrystalline and micrometer-scale samples can be studied with single-crystal-like signal-to-noise. Scattering was measured with an X-ray-sensitive area detector, which measures intensity over a surface in reciprocal space. By scanning the X-ray energy, the intensity was measured over reciprocal-space volumes. Since the sample is not rotated, the real-space scattering volume does not change. Methods to minimize experimental artifacts arising from the use of an area detector are described.

36 MATERIALS SCIENCE↗

ACOUSTIC PRESSURE FIELDS GENERATED WITH A HIGH FREQUENCY ACOUSTIC LEVITATOR

Acoustic levitation is an advantageous particle positioning mechanism currently employed for applications of x-ray spectroscopy and micro-material manufacturing[1], [2]. By levitating a particle using only acoustic pressure waves, one eliminates the need for a container or other physical structure which may contaminate the specimen. Unfortunately, the pressure field generated by a standing acoustic wave is susceptible to periodic instabilities, and a particle that is levitated in this field tends to vibrate. The amplitude of the vibration is largest in the directions that are orthogonal to the axis in which the acoustic wave is generated. Therefore, by generating additional acoustic waves in each orthogonal axis, the vibration amplitude of the levitated particle is significantly reduced. The authors have shown this phenomenon to be true in a previous study[3]. In this paper, the authors explore the details of the pressure field that is generated with the device. A single degree-of freedom relationship is developed between the acoustic field pressure, the location of the levitated particle, and the mechanical vibration needed to produce levitation. In order to levitate a 100 micrometer diameter water droplet at 55 kilohertz, the calculations suggest that the transducer must achieve an average surface vibration amplitude of at least 6.43 micrometers. This mechanical vibration must produce a root means-squared pressure amplitude of 933 Pascal. Under these conditions, the particle will levitate approximately 0.4 millimeters below a zero pressure node. To validate the use of the single degree of freedom relationships and to explore the acoustic field for one, two, and three-axis levitation, the authors designed and prototyped an acoustic levitator capable of generating standing waves in three orthogonal directions. Using a simple electrical control circuit, the acoustic wave transducers of each axis can be turned on individually or simultaneously. An experiment was developed to measure the pressure of the acoustic field using a microphone. Preliminary pressure magnitude results were measured for one axis levitation along the center of the vertical axis of the levitator. The measurements suggest that the theoretical development provides a valid first approximation for the pressure magnitude and required mechanical vibration amplitude.

acoustic levitator↗

SURFACE FINISHING AND ELECTROLESS NICKEL PLATING OF ADDITIVELY MANUFACTURED (AM) METAL COMPONENTS

This study investigates the application of electroless nickel deposition on additively manufactured stainless steel samples. Current additive manufacturing (AM) technologies produce metal components with a rough surface. Rough surfaces generally exhibit fatigue characteristics, increasing the probability of initiating a crack or fracture to the printed part. For this reason, the direct use of as-produced parts in a finished product cannot be actualized, which presents a challenge. Post-processing of the AM parts is therefore required to smoothen the surface. This study analyzes chempolish (CP) and electropolish (EP) surface finishing techniques for post-processing AM stainless steel components CP has a great advantage in creating uniform, smooth surfaces regardless of size or part geometry EP creates an extremely smooth surface, which reduces the surface roughness to the sub-micrometer level. In this study, we also investigate nickel deposition on EP, CP, and as-built AM components using electroless nickel solutions. Electroless nickel plating is a method of alloy treatment designed to increase manufactured component's hardness and surface resistance to the unrelenting environment. The electroless nickel plating process is more straightforward than its counterpart electroplating.. We use low-phosphorus (2-5% P), medium-phosphorus (6-9% P), and high-phosphorus (10-13% P). These Ni deposition experiments were optimized using the L9 Taguchi design of experiments (TDOE), which compromises the prosperous content in the solution, surface finish, plane of the geometry, and bath temperature. The pre-and post-processed surface of the AM parts was characterized by KEYENCE Digital MicroscopeVHX-7000 and Phenom XL Desktop SEM. The experimental results show that electroless nickel deposition produces uniform Ni coating on the additively manufactured components up to 20 μm per hour. Mechanical properties of as-built and Ni coated AM samples were analyzed by applying a standard 10 N scratch test. Nickel coated AM samples were up to two times scratch resistant compared to the as-built samples. This study suggests electroless nickel plating is a robust viable option for surface hardening and finishing AM components for various applications and operating conditions.

Keywords: additive manufacturing, fatigue, chempol↗

Atomic layer deposition of 2D and 3D standards for synchrotron-based quantitative composition and structure analysis methods

Atomic layer deposition (ALD) is a scalable deposition technique known for producing uniform, conformal films of a wide range of compounds on nearly any substrate material. These traits make it an ideal deposition method for producing films to replace the National Institute of Standards and Technology (NIST) standards and create Standard Reference Materials (SRMs) on a wide range of relevant two-dimensional and three-dimensional substrates. The use of SRM from NIST for quantitative analysis of chemical composition using synchrotron based x-ray fluorescence (SR-XRF) and scanning transmission x-ray microscopy (STXM) is common. Such standards, however, can suffer from inhomogeneity in chemical composition and thickness and often require further calculations, based on sample mounting and detector geometry, to obtain quantitative results. These inhomogeneities negatively impact the reproducibility of the measurements and the quantitative measure itself. Utilizing Rutherford backscattering, x-ray reflectivity, quartz crystal microbalance, STXM, and SR-XRF, the authors show that ALD is capable of producing high quality standards that are homogenous over scales ranging from nanometers to 100s of micrometers.

Becker, Nicholas G.↗

Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a synchrotron radiotherapy technique that explores the limits of the dose-volume effect. Preclinical studies have shown that MRT irradiations (arrays of 25-75-{mu}m-wide microbeams spaced by 200-400 {mu}m) are able to eradicate highly aggressive animal tumor models while healthy tissue is preserved. These promising results have provided the basis for the forthcoming clinical trials at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). The first step includes irradiation of pets (cats and dogs) as a milestone before treatment of human patients. Within this context, accurate dose calculations are required. The distinct features of both beam generation and irradiation geometry in MRT with respect to conventional techniques require the development of a specific MRT treatment planning system (TPS). In particular, a Monte Carlo (MC)-based calculation engine for the MRT TPS has been developed in this work. Experimental verification in heterogeneous phantoms and optimization of the computation time have also been performed. Methods: The penelope/penEasy MC code was used to compute dose distributions from a realistic beam source model. Experimental verification was carried out by means of radiochromic films placed within heterogeneous slab-phantoms. Once validation was completed, dose computations in a virtual model of a patient, reconstructed from computed tomography (CT) images, were performed. To this end, decoupling of the CT image voxel grid (a few cubic millimeter volume) to the dose bin grid, which has micrometer dimensions in the transversal direction of the microbeams, was performed. Optimization of the simulation parameters, the use of variance-reduction (VR) techniques, and other methods, such as the parallelization of the simulations, were applied in order to speed up the dose computation. Results: Good agreement between MC simulations and experimental results was achieved, even at the interfaces between two different media. Optimization of the simulation parameters and the use of VR techniques saved a significant amount of computation time. Finally, parallelization of the simulations improved even further the calculation time, which reached 1 day for a typical irradiation case envisaged in the forthcoming clinical trials in MRT. An example of MRT treatment in a dog's head is presented, showing the performance of the calculation engine. Conclusions: The development of the first MC-based calculation engine for the future TPS devoted to MRT has been accomplished. This will constitute an essential tool for the future clinical trials on pets at the ESRF. The MC engine is able to calculate dose distributions in micrometer-sized bins in complex voxelized CT structures in a reasonable amount of time. Minimization of the computation time by using several approaches has led to timings that are adequate for pet radiotherapy at synchrotron facilities. The next step will consist in its integration into a user-friendly graphical front-end.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution x-ray imaging using a structured scintillator

Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leakless end-to-end transport of small molecules through micron-length DNA nanochannels

Designed and engineered protein and DNA nanopores can be used to sense and characterize single molecules and control transmembrane transport of molecular species. However, designed biomolecular pores are less than 100 nm in length and are used primarily for transport across lipid membranes. Nanochannels that span longer distances could be used as conduits for molecules between nonadjacent compartments or cells. We design micrometer-long, 7-nm-diameter DNA nanochannels that small molecules can traverse according to the laws of continuum diffusion. Binding DNA origami caps to channel ends eliminates transport and demonstrates that molecules diffuse from one channel end to the other rather than permeating through channel walls. These micrometer-length nanochannels can also grow, form interconnects, and interface with living cells. This work thus shows how to construct multifunctional, dynamic agents that control molecular transport, opening ways of studying intercellular signaling and modulating molecular transport between synthetic and living cells.

59 BASIC BIOLOGICAL SCIENCES↗

Control and synchronization of rapid nanoscale DNA heat engine by local heating

To further activate devices based on DNA nanotechnology, we introduce an approach that notably enhances both the speed and force of DNA powered machines and artificial hinge machine. A microheater, with millisecond response, heats or recools DNA origami constructs, hybridizing or dehybridizing sticky ends. Because anything within 20 micrometers of the heater equilibrates to a programmed temperature change in milliseconds, sticky ends of a compound DNA origami machine can open and close synchronously and operate cooperatively, in phase, additively increasing the drive force compared to single pair of sticky ends DNA machine (the six-helix bundle DNA origami hinge machine). In our demonstrations, we fold and unfold two square origami with 10 pairs of complementary sticky ends to drive a bead on the end of a rod like origami to speeds exceeding 30 micrometers per second. Our device envisions the creation of complex, synchronized DNA machines.

Science & Technology - Other Topics↗

Spatial control of heavy-fermion superconductivity in CeIrIn 5

While crystals of strongly correlated metals exhibit a diverse set of electronic ground states, few approaches exist for spatially modulating their properties. In this study, we demonstrate disorder-free control, on the micrometer scale, over the superconducting state in samples of the heavy-fermion superconductor CeIrIn 5 . We pattern crystals by focused ion beam milling to tailor the boundary conditions for the elastic deformation upon thermal contraction during cooling. The resulting nonuniform strain fields induce complex patterns of superconductivity, owing to the strong dependence of the transition temperature on the strength and direction of strain. These findings showcase a generic approach to manipulating electronic order on micrometer length scales in strongly correlated matter without compromising the cleanliness, stoichiometry, or mean free path.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

De Novo Design of Self-Assembling Helical Protein Filaments

We describe a general computational approach to designing self-assembling helical filaments from monomeric proteins and use this approach to design proteins that assemble into micrometer-scale filaments with a wide range of geometries in vivo and in vitro. Cryo–electron microscopy structures of six designs are close to the computational design models. The filament building blocks are idealized repeat proteins, and thus the diameter of the filaments can be systematically tuned by varying the number of repeat units. The assembly and disassembly of the filaments can be controlled by engineered anchor and capping units built from monomers lacking one of the interaction surfaces. The ability to generate dynamic, highly ordered structures that span micrometers from protein monomers opens up possibilities for the fabrication of new multiscale metamaterials.

Shen, Hao↗

Observation of second sound in graphite at temperatures above 100 K

Wavelike thermal transport in solids, referred to as second sound, is an exotic phenomenon previously limited to a handful of materials at low temperatures. The rare occurrence of this effect restricted its scientific and practical importance. We directly observed second sound in graphite at temperatures above 100 kelvins by using time-resolved optical measurements of thermal transport on the micrometer-length scale. Our experimental results are in qualitative agreement with ab initio calculations that predict wavelike phonon hydrodynamics. We believe that these results potentially indicate an important role of second sound in microscale transient heat transport in two-dimensional and layered materials in a wide temperature range.

Science & Technology - Other Topics↗

Efficient tandem solar cells with solution-processed perovskite on textured crystalline silicon

Stacking solar cells with decreasing band gaps to form tandems presents the possibility of overcoming the single-junction Shockley-Queisser limit in photovoltaics. The rapid development of solution-processed perovskites has brought perovskite single-junction efficiencies >20%. However, this process has yet to enable monolithic integration with industry-relevant textured crystalline silicon solar cells. We report tandems that combine solution-processed micrometer-thick perovskite top cells with fully textured silicon heterojunction bottom cells. To overcome the charge-collection challenges in micrometer-thick perovskites, we enhanced threefold the depletion width at the bases of silicon pyramids. Moreover, by anchoring a self-limiting passivant (1-butanethiol) on the perovskite surfaces, we enhanced the diffusion length and further suppressed phase segregation. These combined enhancements enabled an independently certified power conversion efficiency of 25.7% for perovskite-silicon tandem solar cells. These devices exhibited negligible performance loss after a 400-hour thermal stability test at 85°C and also after 400 hours under maximum power point tracking at 40°C.

14 SOLAR ENERGY↗

Volumetric additive manufacturing of silica glass with microscale computed axial lithography

Glass is increasingly desired as a material for manufacturing complex microscopic geometries, from the micro-optics in compact consumer products to microfluidic systems for chemical synthesis and biological analyses. As the size, geometric, surface roughness, and mechanical strength requirements of glass evolve, conventional processing methods are challenged. We introduce microscale computed axial lithography (micro-CAL) of fused silica components, by tomographically illuminating a photopolymer-silica nanocomposite that is then sintered. We fabricated three-dimensional microfluidics with internal diameters of 150 micrometers, free-form micro-optical elements with a surface roughness of 6 nanometers, and complex high-strength trusses and lattice structures with minimum feature sizes of 50 micrometers. As a high-speed, layer-free digital light manufacturing process, micro-CAL can process nanocomposites with high solids content and high geometric freedom, enabling new device structures and applications.

36 MATERIALS SCIENCE↗