Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Reduction of Respiratory Liver Tumor Motion by Abdominal Compression in Stereotactic Body Frame, Analyzed by Tracking Fiducial Markers Implanted in Liver

Purpose: To investigate in a three-dimensional framework the effectiveness and reproducibility of reducing the respiratory motion of liver tumors using abdominal compression in a stereotactic body frame. Methods and Materials: A total of 12 patients with liver tumors, who were treated with stereotactic body radiotherapy, were included in this study. These patients had three gold fiducial markers implanted in the healthy liver tissue surrounding the tumor. Fluoroscopic videos were acquired on the planning day and before each treatment fraction to visualize the motion of the fiducial markers during free breathing and varying levels of abdominal compression. Software was developed to track the fiducial markers and measure their excursions. Results: Abdominal compression reduced the patient group median excursion by 62% in the craniocaudal and 38% in the anteroposterior direction with respect to the median free-breathing excursions. In the left-right direction, the median excursion increased 15% (maximal increase 1.6 mm). The median residual excursion was 4.1 mm in the craniocaudal, 2.4 mm in the anteroposterior, and 1.8 mm in the left-right direction. The mean excursions were reduced by compression to <5 mm in all patients and all directions, with two exceptions (craniocaudal excursion reduction of 20.5 mm to 7.4 mm and of 21.1 mm to 5.9 mm). The residual excursions reproduced well during the treatment course, and the craniocaudal excursions measured on the treatment days were never significantly ({alpha} = 0.05) greater than on the planning days. Fine tuning the compression did not considerably change the excursion on the treatment days. Conclusions: Abdominal compression effectively reduced liver tumor motion, yielding small and reproducible excursions in three dimensions. The compression level established at planning could have been safely used on the treatment days.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast-Conserving Therapy: Radiotherapy Margins for Breast Tumor Bed Boost

Purpose: To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. Methods and Materials: A total of 20 patients were studied who had been treated in the supine position for 28 daily fractions. Cone-beam computed tomography scans were regularly acquired according to a shrinking action level setup correction protocol based on bony anatomy registration of the ribs and sternum. The position of the excision area was retrospectively analyzed by gray value cone-beam computed tomography-to-computed tomography registration. Subsequently, three setup correction strategies (on-line, off-line, and no corrections) were applied, according to the rib and breast surface registrations, to estimate the residual setup errors (systematic [{sigma}] and random [{sigma}]) of the excision area. The required margins were calculated using a margin recipe. Results: The image quality of the cone-beam computed tomography scans was sufficient for localization of the EC. The margins required for the investigated setup correction protocols and the setup errors for the left-right, craniocaudal and anteroposterior directions were 8.3 mm ({sigma} = 3.0, {sigma} = 2.6), 10.6 mm ({sigma} = 3.8, {sigma} = 3.2), and 7.7 mm ({sigma} = 2.7, {sigma} = 2.9) for the no correction strategy; 5.6 mm ({sigma} = 2.0, {sigma} = 1.8), 6.5 mm ({sigma} = 2.3, {sigma} = 2.3), and 4.5 mm ({sigma} = 1.5, {sigma} = 1.9) for the on-line rib strategy; and 5.1 mm ({sigma} = 1.8, {sigma} = 1.7), 4.8 mm ({sigma} = 1.7, {sigma} = 1.6), and 3.3 mm ({sigma} = 1.1, {sigma} = 1.6) for the on-line surface strategy, respectively. Conclusion: Considerable geometric uncertainties in the position of the EC relative to the bony anatomy and breast surface have been observed. By using registration of the breast surface, instead of the rib, the uncertainties in the position of the EC area were reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes of Stereotactic Body Radiotherapy for Small Lung Lesions Clinically Diagnosed as Primary Lung Cancer on Radiologic Examination

Purpose: Image-guided biopsy occasionally fails to diagnose small lung lesions, which are highly suggestive of primary lung cancer. The aim of the present study was to evaluate the outcome of stereotactic body radiotherapy (SBRT) for small lung lesions that were clinically diagnosed as primary lung cancer without pathologic confirmation. Methods and Materials: A total of 115 patients were treated with SBRT in 12 institutions. Tumor size ranged from 5 to 45 mm in diameter, with a median of 20 mm. Results: The 3-year and 5-year overall survival rates for patients with a tumor size <=20 mm in diameter (n = 58) were both 89.8%, compared with 60.7% and 53.1% for patients with tumors >20 mm (n = 57) (p <0.0005), respectively. Local progression occurred in 2 patients (3.4%) with a tumor size <=20 mm and in 3 patients (5.3%) with tumors >20 mm. Among the patients with a tumor size <=20 mm, Grade 2 pulmonary complications were observed in 2 (3.4%), but no Grade 3 to 5 toxicity was observed. In patients with a tumor size >20 mm, Grades 2, 3, and 5 toxicity were observed in 5 patients (8.8%), 3 patients (5.3%), and 1 patient (1.8%), respectively. Conclusion: In patients with a tumor <=20 mm in diameter, SBRT was reasonably safe in this retrospective study. The clinical implications of the high local control rate depend on the accuracy of clinical/radiologic diagnosis for small lung lesions and are to be carefully evaluated in a prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

Purpose: To quantify the clinical accuracy of the respiratory motion tracking system of the CyberKnife treatment device. Methods and Materials: Data in log files of 44 lung cancer patients treated with tumor tracking were analyzed. Errors in the correlation model, which relates the internal target motion with the external breathing motion, were quantified. The correlation model error was compared with the geometric error obtained when no respiratory tracking was used. Errors in the prediction method were calculated by subtracting the predicted position from the actual measured position after 192.5 ms (the time lag to prediction in our current system). The prediction error was also measured for a time lag of 115 ms and a new prediction method. Results: The mean correlation model errors were less than 0.3 mm. Standard deviations describing intrafraction variations around the whole-fraction mean error were 0.2 to 1.9 mm for cranio-caudal, 0.1 to 1.9 mm for left-right, and 0.2 to 2.5 mm for anterior-posterior directions. Without the use of respiratory tracking, these variations would have been 0.2 to 8.1 mm, 0.2 to 5.5 mm, and 0.2 to 4.4 mm. The overall mean prediction error was small (0.0 {+-} 0.0 mm) for all directions. The intrafraction standard deviation ranged from 0.0 to 2.9 mm for a time delay of 192.5 ms but was halved by using the new prediction method. Conclusions: Analyses of the log files of real clinical cases have shown that the geometric error caused by respiratory motion is substantially reduced by the application of respiratory motion tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Defined Treatment Margins in Iodine-125 Prostate Brachytherapy

Purpose: Low-dose-rate prostate brachytherapy achieves a very high and effective intraprostatic dose. Implant quality parameters concentrate on the dose received by the prostate (D90, V100) but not that received by the periprostatic tissue. We calculated implant quality parameters, D90 and V100, for the magnetic resonance imaging (MRI)-defined prostate plus 2, 3, and 5 mm. Methods and Materials: A total of 131 men with early-stage prostate cancer treated with iodine-125 brachytherapy represent all those treated with brachytherapy monotherapy in our institution in 2005. Postplan assessment was performed at 1 month using magnetic resonance (MR)-computed tomography (CT) fusion. The prostate V100 and D90 were calculated with 2-, 3-, and 5-mm margins. Results were compared with those in 8 patients with biopsy-proven local failure occurring in an experience of more than 1,100 implants. Results: Mean prostate V100 (SD) and D90 (SD) were 95.6% (4.1) and 117.2% (12.7). For prostate plus a 2-mm margin the D90 was 107.9% (14.3) and for a 3-mm margin 96.0 % (14.0). For prostate plus a 5-mm margin, the D90 was only 78.4% (11.0). The 8 patients experiencing local failure, despite adequate implants, had a lower mean V100 of 91.2% (SD, 2.8; p = 0.0008) and D90 of 103.7% (SD, 8.3; p = 0.002) and significantly inferior margin coverage. Conclusions: Satisfactory coverage of a 2-mm and 3-mm periprostatic margin is obtained with the described planning approach. Coverage falls off significantly by 5 mm. The 8 patients who experienced local failure had significantly lower doses than the margin cohort. Although the V100 and D90 would be considered acceptable, the fall-off in margin coverage was observed by 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Imaging by Megavoltage Computed Tomography for Assessment of Internal Organ Motion During Radiotherapy for Cervical Cancer

Purpose: To assess the internal organ motion of the cervix and uterus by megavoltage computed tomography (MVCT) during intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with Stage IIB-IVA cervical cancer underwent daily MVCT imaging. Internal organ motion was evaluated on 150 pretreatment MVCT images by measuring shifts in their boundaries between the MVCT and kilovoltage (kV) planning CT scan in the anterior, posterior, left and right lateral, and superior and inferior direction. Additional intrafractional patient movement was evaluated on 50 posttreatment MVCT images. Results: Measured cervical motion (mean {+-} SD) was 0.4 {+-} 10.1 mm in the anterior, -3.0 {+-} 6.9 mm in the posterior direction, -3.5 {+-} 4.9 mm in the left and 0.2 {+-} 4.5 mm in the right lateral direction, 2.2 {+-} 8.0 mm in the superior and 0.5 {+-} 5.0 mm in the inferior direction. Compared to the cervix, larger uterine motion was observed. Patient movement during treatment was limited to 1.1 {+-} 1.3 mm, -0.3 {+-} 1.6 mm, and 0.2 {+-} 2.3 mm in anteroposterior, laterolateral and superoinferior direction respectively. Conclusions: MVCT imaging can be used to study patient setup accuracy and cervical and uterine motion during IMRT. This data may be used to refine treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Image-Guidance Frequency on Geometric Accuracy and Setup Margins in Radiotherapy for Locally Advanced Lung Cancer

Purpose: To assess the relative effectiveness of five image-guidance (IG) frequencies on reducing patient positioning inaccuracies and setup margins for locally advanced lung cancer patients. Methods and Materials: Daily cone-beam computed tomography data for 100 patients (4,237 scans) were analyzed. Subsequently, four less-than-daily IG protocols were simulated using these data (no IG, first 5-day IG, weekly IG, and alternate-day IG). The frequency and magnitude of residual setup error were determined. The less-than-daily IG protocols were compared against the daily IG, the assumed reference standard. Finally, the population-based setup margins were calculated. Results: With the less-than-daily IG protocols, 20-43% of fractions incurred residual setup errors {>=}5 mm; daily IG reduced this to 6%. With the exception of the first 5-day IG, reductions in systematic error ({Sigma}) occurred as the imaging frequency increased and only daily IG provided notable random error ({sigma}) reductions ({Sigma} = 1.5-2.2 mm, {sigma} = 2.5-3.7 mm; {Sigma} = 1.8-2.6 mm, {sigma} = 2.5-3.7 mm; and {Sigma} = 0.7-1.0 mm, {sigma} = 1.7-2.0 mm for no IG, first 5-day IG, and daily IG, respectively. An overall significant difference in the mean setup error was present between the first 5-day IG and daily IG (p < .0001). The derived setup margins were 5-9 mm for less-than-daily IG and were 3-4 mm with daily IG. Conclusion: Daily cone-beam computed tomography substantially reduced the setup error and could permit setup margin reduction and lead to a reduction in normal tissue toxicity for patients undergoing conventionally fractionated lung radiotherapy. Using first 5-day cone-beam computed tomography was suboptimal for lung patients, given the inability to reduce the random error and the potential for the systematic error to increase throughout the treatment course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction Liver Shape Variability and Impact on GTV Position During Liver Stereotactic Radiotherapy Using Abdominal Compression

Purpose: For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. Methods and Materials: Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCT scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). Results: We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Conclusions: Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid liver-to-liver registrations on respiratory sorted CBCT scans were small in most patients (<5 mm).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Endorectal Balloon Reduces Intrafraction Prostate Motion During Radiotherapy

Purpose: To investigate the effect of endorectal balloons (ERBs) on intrafraction and interfraction prostate motion during radiotherapy. Methods and Materials: Thirty patients were treated with intensity-modulated radiotherapy, to a total dose of 80 Gy in 40 fractions. In 15 patients, a daily-inserted air-filled ERB was applied. Prostate motion was tracked, in real-time, using an electromagnetic tracking system. Interfraction displacements, measured before each treatment, were quantified by calculating the systematic and random deviations of the center of mass of the implanted transponders. Intrafraction motion was analyzed in timeframes of 150 s, and displacements >1 mm, >3 mm, >5 mm, and >7 mm were determined in the anteroposterior, left-right, and superoinferior direction, and for the three-dimensional (3D) vector. Manual table corrections, made during treatment sessions, were retrospectively undone. Results: A total of 576 and 567 tracks have been analyzed in the no-ERB group and ERB group, respectively. Interfraction variation was not significantly different between both groups. After 600 s, 95% and 98% of the treatments were completed in the respective groups. Significantly fewer table corrections were performed during treatment fractions with ERB: 88 vs. 207 (p = 0.02). Intrafraction motion was significantly reduced with ERB. During the first 150 s, only negligible deviations were observed, but after 150 s, intrafraction deviations increased with time. This resulted in cumulative percentages of 3D-vector deviations >1 mm, >3 mm, >5 mm, and >7 mm that were 57.7%, 7.0%, 0.7%, and 0.3% in the ERB-group vs. 70.2%, 18.1%, 4.6%, and 1.4% in the no-ERB group after 600 s. The largest reductions in the ERB group were observed in the AP direction. These data suggest that a 5 mm CTV-to-PTV margin is sufficient to correct for intrafraction prostate movements when using an ERB. Conclusions: ERB significantly reduces intrafraction prostate motion, but not interfraction variation, and may in particular be beneficial for treatment sessions longer than 150 s.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized Planning Target Volume for Intact Cervical Cancer

Purpose: To model interfraction clinical target volume (CTV) variation in patients with intact cervical cancer and design a planning target volume (PTV) that minimizes normal tissue dose while maximizing CTV coverage. Methods and Materials: We analyzed 50 patients undergoing external-beam radiotherapy for intact cervical cancer using daily online cone-beam computed tomography (CBCT). The CBCTs (n = 972) for each patient were rigidly registered to the planning CT. The CTV was delineated on the planning CT (CTV{sub 0}) and the set of CBCTs ({l_brace}CTV{sub 1}-CTV{sub 25}{r_brace}). Manual (n = 98) and automated (n = 668) landmarks were placed over the surface of CTV{sub 0} with reference to defined anatomic structures. Normal vectors were extended from each landmark, and the minimum length required for a given probability of encompassing CTV{sub 1}-CTV{sub 25} was computed. The resulting expansions were used to generate an optimized PTV. Results: The mean (SD; range) normal vector length to ensure 95% coverage was 4.3 mm (2.7 mm; 1-16 mm). The uniform expansion required to ensure 95% probability of CTV coverage was 13 mm. An anisotropic margin of 20 mm anteriorly and posteriorly and 10 mm superiorly, inferiorly, and laterally also would have ensured a 95% probability of CTV coverage. The volume of the 95% optimized PTV (1470 cm{sup 3}) was significantly lower than both the anisotropic PTV (2220 cm{sup 3}) and the uniformly expanded PTV (2110 cm{sup 3}) (p < 0.001). For a 95% probability of CTV coverage, normal lengths of 1-3 mm were found along the superior and lateral regions of CTV{sub 0}, 5-10 mm along the interfaces of CTV{sub 0} with the bladder and rectum, and 10-14 mm along the anterior surface of CTV{sub 0} at the level of the uterus. Conclusion: Optimizing PTV definition according to surface landmarking resulted in a high probability of CTV coverage with reduced PTV volumes. Our results provide data justifying planning margins to use in practice and clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of the Size of Nodal Metastases on Recurrence Risk in Breast Cancer Patients With 1-3 Positive Axillary Nodes After Mastectomy

Purpose: Use of postmastectomy radiation therapy (PMRT) in breast cancer patients with 1-3 positive nodes is controversial. The objective of this study was to determine whether the size of nodal metastases in this subset could predict who would benefit from PMRT. Methods and Materials: We analyzed 250 breast cancer patients with 1-3 positive nodes after mastectomy treated with contemporary surgery and systemic therapy at our institution. Of these patients, 204 did not receive PMRT and 46 did receive PMRT. Local and regional recurrence risks were stratified by the size of the largest nodal metastasis measured as less than or equal to 5 mm or greater than 5 mm. Results: The median follow-up was 65.6 months. In the whole group, regional recurrences occurred in 2% of patients in whom the largest nodal metastasis measured 5 mm or less vs 6% for those with metastases measuring greater than 5 mm. For non-irradiated patients only, regional recurrence rates were 2% and 9%, respectively. Those with a maximal nodal size greater than 5 mm had a significantly higher cumulative incidence of regional recurrence (P=.013). The 5-year cumulative incidence of a regional recurrence in the non-irradiated group was 2.7% (95% confidence interval [CI], 0.7%-7.2%) for maximal metastasis size of 5 mm or less, 6.9% (95% CI, 1.7%-17.3%) for metastasis size greater than 5 mm, and 16% (95% CI, 3.4%-36.8%) for metastasis size greater than 10 mm. The impact of the maximal nodal size on regional recurrences became insignificant in the multivariable model. Conclusions: In patients with 1-3 positive lymph nodes undergoing mastectomy without radiation, nodal metastasis greater than 5 mm was associated with regional recurrence after mastectomy, but its effect was modified by other factors (such as tumor stage). The size of the largest nodal metastasis may be useful to identify high-risk patients who may benefit from radiation therapy after mastectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗