At least 829 records · Page 46

Time-Dependent Reliability Analysis of Nuclear Hybrid Energy Systems

This paper focuses on developing a framework for comprehensive time-dependent reliability analysis of a nuclear hybrid energy system (NHES) design. Subsystem interactions of this complex integrated system under stochastic electricity demand and load-following operation capabilities requires dynamic reliability assessment of the NHES in component, subsystem and system level. In order to capture the dynamic operational behavior of critical systems and components, a detailed thermal hydraulic model of the NHES is generated using Modelica and tested under different electricity demand histories generated using RAVEN. The physical data (e.g., valve position, flow rates, inlet outlet water temperatures) gathered from Modelica used to calculate time-dependent failure rates through fitting data into the piecewise Weibull distribution. Optimum maintenance interval is calculated, and maintenance cost estimates based on the calculated reliability metric is presented for the selected component. Component time-dependent failure rates fed into the subsystem reliability model built with non-Markovian Stochastic Petri Nets. The component and subsystem failure rates are calculated and updated in every hour to characterize the system behavior appropriately and to understand operational reliability of the NHES design in a given time.

Guler Yigitoglu, Askin↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Advanced Catalytic Solvent for Lower Cost Post-Combustion CO 2 Capture in a Coal-Fired Power Plant

In this report, CAER addresses DOE’s objectives for improvements on post-combustion CO 2 capture through a three-fold approach including 1) advanced solvent, 2) homogeneous catalyst and 3) membrane carbon enrichment system. CAER-B3 solvent was formulated to improve the overall thermodynamics with the addition of a proton receiver while maintaining faster kinetics with the addition of thermally robust primary amine. The EH&S study indicates that CAER-B3 solvent poses little human toxicological or ecological risk in its raw material form. Generation of significant quantities of nitrosamines was deemed unlikely when using B3 solvent for CO 2 capture from coal-derived flue gas. The catalytic solvent caused a 21% reduction in energy demand, achievable via decreasing the liquid flowrate. Cyclic capacity nearly doubled due to the slower flowrate, and therefore, reduced the sensible heat required to remove CO 2 in the stripper. The increased rich loadings achieved by either pre-concentrating membrane or dewatering membrane prior to stripper, in addition to improved cyclic capacity, will lower downstream compression costs, while reducing the energy consumption per unit of CO 2 produced. Moreover, the CAER-B3 solvent demonstrated a greater thermal stability, lessening the rate of amine loss, caused by solvent degradation and emissions, by 50-70%. The CAER developed catalysts with a second order rate constant of 7.5 x 10 4 – 10 5 M -1 s -1 , far beyond those reported to date. The catalyst was designed to be a mimic of the enzyme carbonic anhydrase and increase the rate of CO 2 hydration to produce bicarbonate. As such, a 10-25% improvement in absorption rate was observed over the MEA base case. Enhancements can be imparted to the full scale system to reduce packing height of the absorber column, resulting in significant capital cost savings. Furthermore, the family of CAER catalysts showed less than 10% decomposition over 100 hours at 100 °C, suggesting that these catalysts will be stable in the harsh oxidative and thermal process conditions of an industrial carbon capture unit. Flue gas contaminants, such as NO x and SO x , also did not impact catalytic activity. A method for synthetic production of 500 g/batch was designed, verified, and well-documented, with scaling capabilities up to 500 kg. Two types of membranes were designed and tested for the purpose of increasing the solvent carbon loading prior to entering the stripper column. 500 hour and 100 hour verification studies were completed for the pre-concentrating membrane and zeolite dewatering membrane, respectively. Results demonstrated that a membrane-based CO 2 enrichment step using a commercial CO 2 membrane, or a zeolite dewatering membrane, or both, should be implemented in the carbon capture process to increase the CO 2 partial pressure by 16%, resulting in a stripping energy reduction of 35% relative to DOE Case 12 MEA solvent. Experimental data showed a carbon loading enrichment of 18-40% in comparison to the configuration without the pre-concentrating gas membrane. During the timespan of this project, challenges were identified and addressed so that enhanced performance may be realized long-term. Mitigation implementations included re-configuration of the bench unit with a solvent recovery column and a knock-out drum, as well as an increase in stripper pressure set point. Both changes resulted in a considerable reduction in the rate of solvent loss. Additionally, the membrane synthesis procedure was modified and validated to address zeolite dissolution concerns along with a new separation module. The techno-economic analysis conducted by WorleyParsons indicated the CAER-adCCS hybrid approach may outperform NETL Case 12 with regards to net plant HHV efficiency and cost of electricity.

01 COAL, LIGNITE, AND PEAT↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗

Marin County Wildland Fires: Examining Fuel Load and Land Cover Change to Inform Fire Prevention and Suppression Decisions in Marin County, CA

Heightened occurrence of severe wildfires in the Western United States is increasing the need to better understand regions of high potential wildfire severity and develop methodologies for identifying the best locations for fuels reduction and active wildfire suppression, especially in populated regions such as Marin County, California. Marin County, located in the San Francisco Bay Area, has had significant development in the wildland-urban interface and periods of highly wildfire-prone conditions. The NASA DEVELOP team collaborated with Fire Foundry (a Marin-based fire service workforce development program) and the Marin County Fire Department to develop models to assist with fire management. Using data from Sentinel-2A, PlanetScope, ECOSTRESS, a county-wide LiDAR mapping effort, Landsat 7 Enhanced Thematic Mapper (ETM+), and Landsat 8 Operational Land Imager (OLI), our team developed a number of input data layers for three different models to evaluate wildfire severity. One model performed a suitability analysis with weights based on scientific literature; another model utilized a U-Net Convolutional Neural Network trained on previous fires in Marin and neighboring Sonoma County to predict the difference normalized burn severity; and the third inputted data layers into the FlamMap tool that outputs risk categories. We compared model outputs and performed a weighted overlay analysis to identify specific locations where a fireline could be constructed to interrupt the progress of an active fire. These tools will assist partners in preparing for and managing active wildfire situations.

Remote sensing↗

Generation of EM radiations using intense electron beam produced in vacuum

The results of a pulse power generator driving an axial virtual cathode oscillator are being presented in this paper as a source of high power microwave (HPM) radiations. The electron beam generator is also modified to attain the intense X-ray burst. The pulse power generator used for these applications is common and is having 10 ohms as its characteristic impedance with 50nS of pulse width. The peak charging voltage of the pulse forming line is 450 kV and hence 225 kV and 22.5 kA is peak voltage and peak current delivery capabilities respectively for the pulse power generator. The peak electrical power of the generator is 5GW for a matched load. The charging power supply for the pulse forming line consists of a high voltage generator made by pulse transformer and charging the pulse forming line in the first cycle of the charging pulse. To utilize the energy of the primary capacitive storage efficiently the pulse transformer is having 0.8 coupling coefficient between its primary and the secondary. The axial vircator chamber is evacuated to attain the vacuum of 2 x 10{sup -4} torr for the HPM application. In the case of modified electron beam chamber for the generation of X-rays the vacuum of same order is used. The pulse forming line is made using equal lengths of high voltage transmission lines, each having a length of 10 meters, connected in the parallel to give a net source impedance of 10 ohm. The pulse power generator can operate in repetitive mode and hence the HPM as well as X-rays may be generated in the repetitive burst. (author)

43 PARTICLE ACCELERATORS↗

Algae Asphalt to Enhance Pavement Sustainability and Performance at Subzero Temperatures

This paper evaluates the potential of algae-derived biobinders as sustainable alternatives for pavement construction. It specifically examines the physicochemical and rheological properties of biomodified binders and their potential to offset carbon emissions when used as partial replacements for conventional petroleum-based asphalt binders. Biosequestration of CO 2 using microalgal cell factories is a promising way of recycling CO 2 into biomass via photosynthesis. Our study demonstrates that incorporating algae-derived binders into asphalt can significantly reduce carbon emissions. Each 1% increase in algae-based biobinder leads to an approximate 4.5% decrease in net carbon emissions. This indicates that a blend containing about 22% biobinder has the potential to achieve carbon neutrality. Blends with higher proportions may even result in net-negative emissions, highlighting a promising strategy for environmentally responsible road construction. In terms of performance, the study shows that certain algae-derived biobinders significantly enhance the cracking resistance of asphalt, particularly under subzero temperatures, by improving its stress-relief capacity. A key contribution of this work is the introduction of polarizability as a novel molecular-level parameter for assessing the compatibility of algae-derived bio-oils with asphalt. By capturing the electronic responsiveness of bio-oil molecules, polarizability serves as a predictive indicator of their interaction potential with asphalt components, providing a new dimension for evaluating the binder performance at the molecular scale. Among the tested materials, the biobinder derived from Haematococcus pluvialis demonstrated particularly strong improvements in resistance to permanent deformation under repeated loading conditions analogous to traffic-induced stress, as well as enhanced resistance to moisture-induced damage. In conclusion, these findings advance the chemistry-driven design of biomass-based binders and highlight a promising pathway toward the development of low-carbon, high-performance, and sustainable infrastructure materials.

Algae↗

Spatially resolved land and grid model of carbon neutrality in China

China has committed to achieve net carbon neutrality by 2060 to combat global climate change, which will require unprecedented deployment of negative emissions technologies, renewable energies (RE), and complementary infrastructure. At terawatt-scale deployment, land use limitations interact with operational and economic features of power systems. To address this, we developed a spatially resolved resource assessment and power systems planning optimization that models a full year of power system operations, sub-provincial RE siting criteria, and transmission connections. Our modeling results show that wind and solar must be expanded to 2,000 to 3,900 GW each, with one plausible pathway leading to 300 GW/yr combined annual additions in 2046 to 2060, a three-fold increase from today. Over 80% of solar and 55% of wind is constructed within 100 km of major load centers when accounting for current policies regarding land use. Large-scale low-carbon systems must balance key trade-offs in land use, RE resource quality, grid integration, and costs. Under more restrictive RE siting policies, at least 740 GW of distributed solar would become economically feasible in regions with high demand, where utility-scale deployment is limited by competition with agricultural land. Effective planning and policy formulation are necessary to achieve China’s climate goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Application of Flexible Multibody Simulations to Space Launch Systems Liftoff Pad Separation and Umbilical Disconnect

A flexible multibody dynamics approach is applied to the Space Launch System (SLS) liftoff Coupled Loads Analysis (CLA), enabling the inclusion of a large array of component nonlinearities with extreme computational efficiency. The nonlinearities include the cryogenic induced preloads due to the large rotations of the aft struts connecting the Core Stage (CS) to the boosters, the contact/separation and potential re-contact at the booster aft skirt to Mobile Launcher(ML) interface, contact/separation and potential re-contact at the ML/extensible columns interfaces, secondary disconnect of the CS umbilicals including the LOX and LH2 Tail Service Mast Umbilicals (TSMUs), and the disconnect of the upper stage umbilical, the Interim Cryogenic Propulsion Stage Umbilical (ICPSU). The ICPSU disconnect involves algorithms simulating the winch motors reeling lanyard ropes, the nonlinear modeling of ropes and hoses, the disconnect and capture of multiple umbilical ground plates by catch-nets (geometrically nonlinear models), and the large rotations of the ML gantry in order to track clearances between the lifting SLS vehicle and umbilicals rotating out of the way. The flexible multibody dynamics framework utilized for these simulations provided a systematic and efficient framework for adding complex nonlinearities at the system level which would have otherwise not been possible in standard CLAs or would have to be treated by separate local analyses thereby not accounting for the coupled system behavior.

Application↗

Evaluation of Carbon Dioxide Capture From Existing Coal Fired Plants by Hybrid Sorption Using Solid Sorbents

A novel hybrid solid sorbent technology for CO₂ capture and separation from coal combustion-derived flue gas was evaluated. The technology – Capture of CO₂ by Hybrid Sorption (CACHYS™) – is a solid sorbent technology based on the following ideas: 1) reduction of energy for sorbent regeneration, 2) utilization of novel process chemistry, 3) contactor conditions that minimize sorbent-CO₂ heat of reaction and promote fast CO₂ capture, and 4) low-cost method of heat management. This report provides key information developed during the course of the project that includes sorbent performance, energy for sorbent regeneration, physical properties of the sorbent, the integration of process components, sizing of equipment, and overall capital and operational cost of the integrated CACHYS™ system. Seven sorbent formulations were prepared and evaluated at the lab-scale for energy requirements and CO₂ capture performance. Sorbent heat of regeneration ranged from 30-80 kJ/mol CO₂ and was found to be dependent on process conditions. Two sorbent formulations (designated HCK-4 & HCK-7) were down-selected for additional fixed-bed testing. Additional testing involved subjecting the sorbents to 100 continuous cycles in the fixed-bed reactor to determine performance as a function of time. The working capacity achieved for HCK-4 sorbent ranged from 5.5-8.0 g CO₂/100 g sorbent, while the HCK-7 typically ranged from 8.0-10.0 g CO₂/100 g sorbent. Overall, there was no deterioration in capacity with continuous cycling for either sorbent. The CACHYS™ bench-scale testing system designed and fabricated under this award consists of a dual circulating fluidized-bed adsorber and a moving-bed regenerator. The system takes a flue gas slipstream from the University of North Dakota’s coal-fired steam plant. Prior to being sent to the adsorber, the flue gas is scrubbed to remove SO₂ and particulate. During parametric testing of the adsorber, CO₂ capture achieved using the 2-bed configuration with recirculation in both beds was 65-70% with a high flue gas CO₂ loading (~7%) and up to 85% with a low flue gas CO₂ loading (~4%). A sorbent regenerator system consisting of a pre-heater, desorber, and cooler is used to heat the CO₂-rich sorbent with direct and indirect steam producing a nearly 100% pure stream of CO₂. Parametric testing of the regenerator system demonstrated the impact of process conditions on both desorption rate and the heat of regeneration. Clear evidence of the use of specific process conditions that lower the overall energy of desorption was identified. This observation validates measurements made at the laboratory-scale. Several longer-term continuous tests were conducted to evaluate the performance of the sorbent/process as a function of time. Using a 2-bed configuration, sustained capture efficiency of 40-60% with a high flue gas CO₂ loading (~8%) and 70-80% with a low flue gas CO₂ loading (~4%) were achieved. However, sorbent working capacity was found to be considerably lower than laboratory-scale measurements. The low working capacity is attributed to insufficient sorbent/gas contact time in the adsorber. Sorbent properties that had a significant impact on CO₂ capture performance were identified. The results show that controlling these sorbent properties substantially improves CO₂ capture performance, with preliminary estimates indicating that relative improvement of ~30% is possible. Testing culminated with an operationally trouble-free test of 15 hours with sustainable performance. Overall, several practical strategies to increase performance of the sorbent and process were identified. The initial technical and economic assessment of the CACHYS™ process estimated the cost of CO2 capture was $36.19/ton with a 48.6% increase in levelized cost of electricity (LCOE) for the 550 MWe net plant. Using additional data gathered over the course of the project, and with revised technical and economic assumptions, the estimated cost of CO₂ capture with the CACHYS™ process is $39/ton (only includes the cost of the CO2 capture system) with an increase in LCOE of 55.9%. Overall, CACHYS™ represents a significant improvement over the benchmark MEA system, and has demonstrated progress towards achieving DOE’s goals for CO₂ capture technologies.

01 COAL, LIGNITE, AND PEAT↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuel Property Effects of a Broad Range of Potential Biofuels on Mixing Control Compression Ignition Engine Performance and Emissions

Conventional diesel engines will continue to hold a vital role in the heavy- and medium-duty markets for the transportation of goods along with many other uses. The ability to offset traditional diesel fuels with low-net-carbon biofuels could have a significant impact on reducing the carbon footprint of these vehicles. A prior study screened several hundred candidate biofuel blendstocks based on required diesel blendstock properties and identified 12 as the most promising. Eight representative biofuel blendstocks were blended at a 30% volumetric concentration with EPA certification ultra-low-sulfur diesel (ULSD) and were investigated for emissions and fuel efficiency performance. This study used a single cylinder engine (based on the Ford 6.7L engine) using Conventional Diesel Combustion (CDC), also known as Mixing Control Compression Ignition (MCCI). The density, cetane number, distillation curve and sooting tendency (using the yield sooting index method) of the fuels were measured. Start of injection (SOI) timing and exhaust gas recirculation (EGR) sweeps were conducted at three separate speed-load operating points to examine fuel effects on the NOX/soot and NOX/efficiency trade-offs as well as to evaluate EGR tolerance. The results show that the biofuel blends all reduced NOX and soot emissions without penalty to engine efficiency, even improving efficiency for some of the blends at certain points, with one particular blend of polyoxymethylene ethers (POMEs) improving efficiency at all points while drastically reducing soot by 79%.

47 OTHER INSTRUMENTATION↗

Challenges and Lessons Learned from an Analysis of Three Zero Energy Buildings

Zero energy buildings, or zero energy ready buildings, which are designed and operated by public or private commercial property owners can play an important role in reducing carbon emissions. This paper discusses lessons learned and key takeaways from an in-depth analysis of three zero energy buildings that took an integrated design and construction approach to significantly reduce energy use. Two of these projects are new construction and one is a retrofit to zero energy. Findings are based on project literature review, data analysis, and in-depth interviews with the building design teams and staff who were involved during the design, construction, and operation of the buildings. The paper addresses value proposition and cost data in such a way that other building owners can replicate the strategies and technology solutions in response to regulatory mandates or organizational goals. It also provides details on operational improvements taken at each zero energy building to enhance energy performance and increase the potential for load flexibility, and discusses challenges and lessons gleaned from design teams and building staff. The findings serve as a reference for building owners, designers, engineers, contractors, or others interested in, or involved with, the design, construction, or use of new or existing buildings. The paper also includes recommended pathways for widespread adoption of zero energy strategies that can be applied in various locations.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Exit blade geometry and part-load performance of small axial flow propeller turbines: An experimental investigation

A detailed experimental investigation of the effects of exit blade geometry on the part-load performance of low-head, axial flow propeller turbines is presented. Even as these turbines find important applications in small-scale energy generation using micro-hydro, the relationship between the layout of blade profile, geometry and turbine performance continues to be poorly characterized. The experimental results presented here help understand the relationship between exit tip angle, discharge through the turbine, shaft power, and efficiency. The modification was implemented on two different propeller runners and it was found that the power and efficiency gains from decreasing the exit tip angle could be explained by a theoretical model presented here based on classical theory of turbomachines. In particular, the focus is on the behaviour of internal parameters like the runner loss coefficient, relative flow angle at exit, mean axial flow velocity and net tangential flow velocity. The study concluded that the effects of exit tip modification were significant. The introspective discussion on the theoretical model's limitation and test facility suggests wider and continued experimentation pertaining to the internal parameters like inlet vortex profile and exit swirl profile. It also recommends thorough validation of the model and its improvement so that it can be made capable for accurate characterization of blade geometric effects. (author)

13 HYDRO ENERGY↗

Rubisco activity and activation state dictate photorespiratory plasticity in Betula papyrifera acclimated to future climate conditions

Plant metabolism faces a challenge of investing enough enzymatic capacity to a pathway without overinvestment. As it takes energy and resources to build, operate, and maintain enzymes, there are benefits and drawbacks to accurately matching capacity to the pathway influx. The relationship between functional capacity and physiological load could be explained through symmorphosis, which would quantitatively match enzymatic capacity to pathway influx. Alternatively, plants could maintain excess enzymatic capacity to manage unpredictable pathway influx. In this study, we use photorespiration as a case study to investigate these two hypotheses in Betula papyrifera. This involves altering photorespiratory influx by manipulating the growth environment, via changes in CO 2 concentration and temperature, to determine how photorespiratory capacity acclimates to environmental treatments. Surprisingly, the results from these measurements indicate that there is no plasticity in photorespiratory capacity in B. papyrifera, and that a fixed capacity is maintained under each growth condition. The fixed capacity is likely due to the existence of reserve capacity in the pathway that manages unpredictable photorespiratory influx in dynamic environments. Additionally, we found that B. papyrifera had a constant net carbon assimilation under each growth condition due to an adjustment of functional rubisco activity driven by changes in activation state. These results provide insight into the acclimation ability and limitations of B. papyrifera to future climate scenarios currently predicted in the next century.

59 BASIC BIOLOGICAL SCIENCES↗

Energy Saving Melting and Revert Reduction Technology (E-SMARRT): Mechanical Performance of Dies

As a net shape process, die casting is intrinsically efficient and improvements in energy efficiency are strongly dependent on design and process improvements that reduce scrap rates so that more of the total consumed energy goes into acceptable, usable castings. A casting that is distorted and fails to meet specified dimensional requirements is typically remelted but this still results in a decrease in process yield, lost productivity, and increased energy consumption. This work focuses on developing, and expanding the use of, computer modeling methods that can be used to improve the dimensional accuracy of die castings and produce die designs and machine/die setups that reduce rejection rates due to dimensional issues. A major factor contributing to the dimensional inaccuracy of the casting is the elastic deformations of the die cavity caused by the thermo mechanical loads the dies are subjected to during normal operation. Although thermal and die cavity filling simulation are widely used in the industry, structural modeling of the die, particularly for managing part distortion, is not yet widely practiced. This may be due in part to the need to have a thorough understanding of the physical phenomenon involved in die distortion and the mathematical theory employed in the numerical models to efficiently model the die distortion phenomenon. Therefore, two of the goals of this work are to assist in efforts to expand the use of structural modeling and related technologies in the die casting industry by 1) providing a detailed modeling guideline and tutorial for those interested in developing the necessary skills and capability and 2) by developing simple meta-models that capture the results and experience gained from several years of die distortion research and can be used to predict key distortion phenomena of relevance to a die caster with a minimum of background and without the need for simulations. These objectives were met. A detailed modeling tutorial was provided to NADCA for distribution to the industry. Power law based meta-models for predicting machine tie bar loading and for predicting maximum parting surface separation were successfully developed and tested against simulation results for a wide range of machines and experimental data. The models proved to be remarkably accurate, certainly well within the requirements for practical application. In addition to making die structural modeling more accessible, the work advanced the state-of-the-art by developing improved modeling of cavity pressure effects, which is typically modeled as a hydrostatic boundary condition, and performing a systematic analysis of the influence of ejector die design variables on die deflection and parting plane separation. This cavity pressure modeling objective met with less than complete success due to the limits of current finite element based fluid structure interaction analysis methods, but an improved representation of the casting/die interface was accomplished using a combination of solid and shell elements in the finite element model. This approximation enabled good prediction of final part distortion verified with a comprehensive evaluation of the dimensions of test castings produced with a design experiment. An extra deliverable of the experimental work was development of high temperature mechanical properties for the A380 die casting alloy. The ejector side design objective was met and the results were incorporated into the metamodels described above. This new technology was predicted to result in an average energy savings of 2.03 trillion BTU's/year over a 10 year period. Current (2011) annual energy saving estimates over a ten year period, based on commercial introduction in 2009, a market penetration of 70% by 2014 is 4.26 trillion BTU's/year by 2019. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.085 Million Metric Tons of Carbon Equivalent (MM TCE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗