Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose Measurements in a 20-J Repetitive Plasma Focus

In this article, the results of X-ray dose measurements executed using thermoluminescent dosimeters in experiments with a very small (20 J) repetitive plasma focus device named SORENA-1 are presented and analyzed. The working gas in these experiments was Argon. Also, pinch formation in experiments with this device has been observed. This device has been designed and constructed in Plasma and Nuclear Fusion Research School of Nuclear Science and Technology Research Institute of Iran. From these results, it is concluded that we can do experiments with this device using Ar as working gas all over the working days of year, and a good symmetry for measured dose around the device has been seen.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of the Charge State of Xenon Ions on the Depth Distribution Profile Upon Implantation into Silicon

Experimental depth distributions of the concentration of implanted xenon ions depending on their charge state and irradiation energy are presented. Xenon ions in charge states q = 1–20 and energies in the range from 50 to 400 keV are incorporated into single-crystal silicon. Irradiation is performed in the direction not coinciding with the crystallographic axes of the crystal to avoid the channeling effect. The ion fluence varies in the range of 5 × (10{sup 14}–10{sup 15}) ion/cm{sup 2}. The irradiation by singly charged ions and investigation of the samples by Rutherford backscattering spectroscopy is performed using an HVEE acceleration complex at Moscow State University. Multiply charged ions are implanted using a FAMA acceleration complex at the Vinća Institute of Nuclear Sciences. The depth distribution profiles of the incorporated ions are found using Rutherford backscattering spectroscopy. Experimental results are correlated with computer calculations. It is shown that the average projective path of multiply charged ions in most cases is shorter when compared with the average projected path of singly charged ions and the results of computer modeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TMDs and GPDs at a future Electron-Ion Collider

With two options studied at Brookhaven National Lab and Jefferson Laboratory the U.S., an Electron-Ion Collider (EIC) of energy √s=20-100 GeV was under design. Furthermore, the recent 2015 US Nuclear Science Long-Range Planning effort included a future EIC as a recommendation for future construction. The EIC will be unique in colliding polarised electrons off polarised protons and light nuclei, providing the spin degrees of freedom essential to pursue its physics program driven by spin structure, multi-dimensional tomographic images of protons and nuclei, and discovery of the role of collective effects of gluons in nuclei. The foreseen luminosity of the EIC, coupled with its energy variability and reach, will allow unprecedented three-dimensional imaging of the gluon and sea quark distributions, via both TMDs and GPDs, and to explore correlations amongst them. Its hermetic detection capability of correlated fragments promises to similar allow for precise tomographic images of the quark-gluon landscape in nuclei, transcending from light few-body nuclei to the heaviest nuclei, and could uncover how the TMD and GPD landscape changes when gluons display an anticipated collective behavior at the higher energies.

43 PARTICLE ACCELERATORS↗

Advances in boronization on NSTX-Upgrade

Boronization has been effective in reducing plasma impurities and enabling access to higher density, higher confinement plasmas in many magnetic fusion devices. The National Spherical Torus eXperiment, NSTX, has recently undergone a major upgrade to NSTX-U in order to develop the physics basis for a ST-based Fusion Nuclear Science Facility (FNSF) with capability for double the toroidal field, plasma current, and NBI heating power and increased pulse duration from 1–1.5 s to 5–8 s. A new deuterated tri-methyl boron conditioning system was implemented together with a novel surface analysis diagnostic. We report on the spatial distribution of the boron deposition versus discharge pressure, gas injection and electrode location. The oxygen concentration of the plasma facing surface was measured by in-vacuo XPS and increased both with plasma exposure and with exposure to trace residual gases. This increase correlated with the rise of oxygen emission from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

PPPL ST-FNSF Engineering Design Details

One of the goals of the PPPL Spherical Tokamak (ST) Fusion Nuclear Science Facility (FNSF) study was to generate a self-consistent conceptual design of an STFNSF device with sufficient physics and engineering details to evaluate the advantages and disadvantages of different designs and to assess various ST-FNSF missions. This included striving to achieve tritium self-sufficiency; the ability to provide shielding protection of vital components and to develop maintenance strategies that could be used to maintain the in-vessel components (divertors, breeding blankets, shield modules and services) and characterize design upgrade potentials to expanded mission evolutions. With the conceptual design of a 2.2 m ST pilot plant design already completed emphasis was placed on evaluating a range of ST machine sizes looking at a major radius of 1m and a mid-range device size between 1 m and 2.2 m. This paper will present an engineering summary of the design details developed from this study, expanding on earlier progress reports presented at earlier conferences that focused on a mid-size 1.7 m device. Further development has been made by physics in defining a Super-X divertor arrangement that provides an expanded divertor surface area and places all PF coils outside the TF coil inner bore, in regions that improve the device maintenance characteristics. Physics, engineering design and neutronics analysis for both the 1.7 m and 1 m device have been enhanced. In conclusion, the engineering results of the PPPL ST-FNSF study will be presented along with comments on possible future directions.

42 ENGINEERING↗

Nuclear Wallet Cards

The Nuclear Wallet Cards present properties for ground and isomeric states of all known nuclides. It provides the following: Spin and parity assignments, Nuclear mass excesses, Half-lives, isotopic abundances, Decay modes. Appendices contain properties of elements, fundamental constants and other useful information.

Decay modes↗

DESIGN UPDATE ON THE HSR INJECTION KICKER FOR THE EIC

The Electron-Ion Collider (EIC), the next-generation nuclear science facility, is under the design at the Brookhaven National Laboratory. The present RHIC rings will be reconfigured as the Hadron Storage Ring (HSR) for the EIC. Design of a stripline injection kicker for the HSR for beams with the rigidity of ~ 81 T-m poses some technical challenges due to the expected shorter bunch spacing, heating due to higher peak current and the larger number of bunches, and the required higher pulsed voltage. Recently, we updated its mechanical design to optimize the characteristic and beam coupling impedances. In addition, we incorporated the impedance tuning capability by introducing the kicker aperture adjustment mechanism. Finally, we incorporated high voltage FID feedthroughs (FC26) to this kicker. This paper reports the design and optimization updates of the HSR injection kicker including the impedance tuning capability, optimization of both the characteristic and the beam coupling impedances, and finally the incorporation of a high voltage feedthrough design.

HSR INJECTION KICKER FOR THE EIC∗↗

Production of Medical Isotopes with Electron Linacs

Radioisotopes play important roles in numerous areas ranging from medical treatments to national security and basic research. Radionuclide production technology for medical applications has been pursued since the early 1900s both commercially and in nuclear science centers. Many medical isotopes are now in routine production and are used in day-to-day medical procedures. Despite these advancements, research is accelerating around the world to improve the existing production methodologies as well as to develop novel radionuclides for new medical appli-cations. Electron linear accelerators (linacs) represent a unique method for the production of radioisotopes. Even though the basic technology has been around for decades, only recently have electron linacs capable of producing photons with sufficient energy and flux for radioisotope production become available. Housed in Argonne Nation-al Laboratory’s Low Energy Accelerator Facility (LEAF) is a newly upgraded 55 MeV/25-kW electron linear ac-celerator, capable of producing a wide range of radioiso-topes. This talk will focus on the work being performed for the production of the medical isotopes 99Mo (99Mo/99mTc generator), 67Cu, and 47Sc.

Cu-67↗

Vibrational Spectroscopy of Chromatographic Interfaces

Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Very High-Temperature Reactor (VHTR) Proliferation Resistance and Physical Protection (PR&PP)

This report documents the detailed background information that has been compiled to support the preparation of a much shorter white paper on the design features and fuel cycles of Very High-Temperature Reactors (VHTRs), including the proposed Next-Generation Nuclear Plant (NGNP), to identify the important proliferation resistance and physical protection (PR&PP) aspects of the proposed concepts. The shorter white paper derived from the information in this report was prepared for the Department of Energy Office of Nuclear Science and Technology for the Generation IV International Forum (GIF) VHTR Systems Steering Committee (SSC) as input to the GIF Proliferation Resistance and Physical Protection Working Group (PR&PPWG) (http://www.gen-4.org/Technology/horizontal/proliferation.htm). The short white paper was edited by the GIF VHTR SCC to address their concerns and thus may differ from the information presented in this supporting report. The GIF PR&PPWG will use the derived white paper based on this report along with other white papers on the six alternative Generation IV design concepts (http://www.gen-4.org/Technology/systems/index.htm) to employ an evaluation methodology that can be applied and will evolve from the earliest stages of design. This methodology will guide system designers, program policy makers, and external stakeholders in evaluating the response of each system, to determine each system's resistance to proliferation threats and robustness against sabotage and terrorism threats, and thereby guide future international cooperation on ensuring safeguards in the deployment of the Generation IV systems. The format and content of this report is that specified in a template prepared by the GIF PR&PPWG. Other than the level of detail, the key exception to the specified template format is the addition of Appendix C to document the history and status of coated-particle fuel reprocessing technologies, which fuel reprocessing technologies have yet to be deployed commercially and have only been demonstrated in testing at a laboratory scale.

Moses, David Lewis↗

A new class of accelerated kinetic Monte Carlo algorithms

Kinetic ( aka dynamic) Monte Carlo (KMC) is a powerful method for numerical simulations of time dependent evolution applied in a wide range of contexts including biology, chemistry, physics, nuclear sciences, financial engineering, etc. Generally, in a KMC the time evolution takes place one event at a time, where the sequence of events and the time intervals between them are selected (or sampled) using random numbers. While details of the method implementation vary depending on the model and context, there exist certain common issues that limit KMC applicability in almost all applications. Among such is the notorious 'flicker problem' where the same states of the systems are repeatedly visited but otherwise no essential evolution is observed. In its simplest form the flicker problem arises when two states are connected to each other by transitions whose rates far exceed the rates of all other transitions out of the same two states. In such cases, the model will endlessly hop between the two states otherwise producing no meaningful evolution. In most situation of practical interest, the trapping cluster includes more than two states making the flicker somewhat more difficult to detect and to deal with. Several methods have been proposed to overcome or mitigate the flicker problem, exactly or approximately. Of the exact methods, the one proposed by Novotny is perhaps most relevant to our research. Novotny formulates the problem of escaping from a trapping cluster as a Markov system with absorbing states. Given an initial state inside the cluster, it is in principle possible to solve the Master Equation for the time dependent probabilities to find the walker in a given state (transient or absorbing) of the cluster at any time in the future. Novotny then proceeds to demonstrate implementation of his general method to trapping clusters containing the initial state plus one or two transient states and all of their absorbing states. Similar methods have been subsequently proposed in [refs] but applied in a different context. The most serious deficiency of the earlier methods is that size of the trapping cluster size is fixed and often too small to bring substantial simulation speedup. Furthermore, the overhead associated with solving for the probability distribution on the trapping cluster sometimes makes such simulations less efficient than the standard KMC. Here we report on a general and exact accelerated kinetic Monte Carlo algorithm generally applicable to arbitrary Markov models1. Two different implementations are attempted both based on incremental expansion of trapping sub-set of Markov states: (1) numerical solution of the Master Equation with absorbing states and (2) incremental graph reduction followed by randomization. Of the two implementations, the 2nd one performs better allowing, for the first time, to overcome trapping basins spanning several million Markov states. The new method is used for simulations of anomalous diffusion on a 2D substrate and of the kinetics of diffusive 1st order phase transformations in binary alloys. Depending on temperature and (alloy) super-saturation conditions, speedups of 3 to 7 orders of magnitude are demonstrated, with no compromise of simulation accuracy.

97 MATHEMATICS AND COMPUTING↗

Short-Bunch Stacking Mode for The PSR: An Overview

The overall upgrade involving a short-bunch PSR mode proceeds from the WNRproposed-project main goals, namely greatly enhancing the ability of WNR to measure neutron cross-sections and reaction dynamics, in a wide neutron-energy range (from thermal to ~100 MeV.) Such measurements, with currently (and surprisingly) sparse data, are of strong interest to several areas of application including weapons physics, nuclear science and engineering, astrophysics, homeland defense, and isotope production. As well as accelerator enhancement, the project plans to enhance radiochemistry facilities, revive the shelved radioactive-species-isotope separator, create a new faster version (TANGO) of the DANCE detector used at LANSCE, and enhance the WNR target and data-taking infrastructure. The cost of all this has not been well established and funding (so far negligible) is needed to achieve a credible figure. A proposal has been sent to NNSA and is currently under review.

Accelerator Design, Technology, and Operations↗

Laboratory Directed Research and Development Annual Report (FY 2013)

The mission of Pacific Northwest National Laboratory is to transform the world through courageous discovery and innovation. Every day, scientists and engineers at PNNL set out to fulfill the promise of that mission by advancing scientific discovery and delivering critical solutions to the challenges that face our nation and the world. The science and technology we work with, create, and improve upon inspires and enables the world to live prosperously, safely, and securely. Our investments in Laboratory Directed Research and Development are essential to our ability to advance our strategy and realize this mission. LDRD investments help us nurture science and technology capabilities while capitalizing on the breadth and depth of talent that our staff possess. This report describes how we conduct our LDRD program in compliance with DOE objectives and guidelines. We use rigorous internal and external peer review to maintain the scientific value and soundness of the research enabled by our LDRD program.

advanced sensors and instrumentation↗

High Sensitivity SPECT for Small Animals and Plants

Imaging systems using single gamma-ray emitting radioisotopes typically implement collimators in order to form the images. However, a tradeoff in sensitivity is inherent in the use of collimators, and modern preclinical single-photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma-rays (<0.3%). We have built a collimator-less system, which can reach sensitivity of 40% for 99 mTc imaging, while still producing images of sufficient spatial resolution for certain applications in thin objects such as mice, small plants, and well plates used for in vitro experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗