Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Progress on a Multichannel, Dual-Mixer Stability Analyzer

Several documents describe aspects of the continuing development of a multichannel, dual-mixer system for simultaneous characterization of the instabilities of multiple precise, low-noise oscillators. One of the oscillators would be deemed to be a reference oscillator, its frequency would be offset by an amount (100 Hz) much greater than the desired data rate, and each of the other oscillators would be compared with the frequency-offset signal by operation of a combination of hardware and software. A high-rate time-tag counter would collect zero-crossing times of the approximately equal 100-Hz beat notes. The system would effect a combination of interpolation and averaging to process the time tags into low-rate phase residuals at the desired grid times. Circuitry that has been developed since the cited prior article includes an eight-channel timer board to replace an obsolete commercial time-tag counter, plus a custom offset generator, cleanup loop, distribution amplifier, zero-crossing detector, and frequency divider.

Kirk, Albert↗

Experiments with phase transitions at very high pressure

A diamond anvil cell is described which was developed for studying hydrogen and other materials to pressure above 100 PGa, including measurements at low temperature. The benefits of X-ray diffraction using synchrotron radiation and using a fixed anode source are examined as well as the optimization of X-ray diffraction at low temperature. A Ge diode detector was incorporated into apparatus for measuring optical absorption, reflectance, and fluorescence in order to enable luminescence studies and Raman spectra were obtained. Results of experiments on Si, Ge, GaP, InAs, hydrogen, benzene, nitrogen, graphite, and the superconductor CeCu2Si2 are given.

Spain, I. L.↗

Atomic Force Microscope Mediated Chromatography

The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

Anderson, Mark S.↗

Commutated automatic gain control system

The commutated automatic gain control (AGC) system was designed and built for the prototype Loran-C receiver is discussed. The current version of the prototype receiver, the Mini L-80, was tested initially in 1980. The receiver uses a super jolt microcomputer to control a memory aided phase loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The AGC control adjusts the level of each station signal, such that the early portion of each envelope rise is about at the same amplitude in the receiver envelope detector.

Yost, S. R.↗

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

Test of the Equivalence Principle in an Einstein Elevator

The scientific goal of the experiment is to test the equality of gravitational and inertial mass (i.e., to test the Principle of Equivalence) by measuring the independence of the rate of fall of bodies from the composition of the falling body. The measurement is accomplished by measuring the relative displacement (or equivalently acceleration) of two falling bodies of different materials which are the proof masses of a differential accelerometer. The goal of the experiment is to measure the Eotvos ratio delta-g/g (differential acceleration/common acceleration) with an accuracy goal of a few parts in 10(exp 15). The estimated accuracy is about two orders of magnitude better than the present state of the art. The experiment is a null experiment in which a result different from zero will indicate a violation of the Equivalence Principle. The main goal of the study to be carried out under this grant is the flight definition of the experiment and bread boarding of critical components of the experiment that will enable us to be ready for the following phases of the project. The project involves an international cooperation in which the responsibility of the US side is the flight definition of the experimental facility while the responsibility of the non-US partners is the flight definition and laboratory prototyping of the differential acceleration detector. In summary, the experiment to be designed is for taking differential acceleration measurements with a high-sensitivity detector (the sensor) during free fall conditions lasting up to 30 s in a disturbance-free acceleration environment. The experiment strategy consists in letting the sensor free fall inside a few meters long (in the vertical direction) evacuated capsule that is falling simultaneously in the rarefied atmosphere after release from a helium balloon flying at a stratospheric altitude.

Shapiro, Irwin I.↗

Neutron fluences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (En < or = 0.2 eV), resonance (0.2 eV < En < 1.0 MeV) and fast (En > or = 1.0 MeV) neutrons. The first two groups were measured with U.S. 6LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d-1 were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d-1. Inside the spacecraft, a value of 3.5 mrem d-1 was found.

NASA Discipline Number 00-00↗

SEXTANT X-Ray Pulsar Navigation Demonstration: Initial On-Orbit Results

Millisecond pulsars (MSPs) are rapidly rotating neutron stars that appear to pulsate across the electromagnetic spectrum. Some MSPs have long-term timing stability that rivals that of atomic clocks. Pulse arrival phase can be predicted with great accuracy at any reference point in the Solar System through use of a pulsar timing model on a spacecraft. Comparing observed phase to predictions gives information that may be used in a navigation process. Why X-rays? Some stable MSPs have conveniently detectable X-ray emissions. X-rays are immune to interstellar dispersion effects thought to limit radio pulsar timing models. Highly directional compact detectors possible.

Navigatio↗

Signatures of linearized gravity in atom interferometers: A simplified computational framework

We develop a general framework for calculating the leading-order, general relativistic contributions to the gravitational phase shift in single-photon atom interferometers within the context of linearized gravity. We show that the atom gradiometer observable, which only depends on the atom interferometer propagation phase, can be written in terms of three distinct contributions: the Doppler phase shift, which accounts for the tidal displacement of atoms along the baseline, the Shapiro phase shift, which accounts for the delay in the arrival time of photons at atom-light interaction points, and the Einstein phase shift, which accounts for the gravitational redshift measured by the atoms. For specific atom gradiometer configurations, we derive the signal and response functions for two physically motivated scenarios: (i) transient gravitational waves in the transverse-traceless gauge and, for the first time, in the proper detector frame, and (ii) transient massive objects sourcing weak and slow-varying Newtonian potentials. Here, we find that the Doppler contribution of realistic Newtonian noise sources (e.g., a freight truck or a piece of space debris) at proposed atom gradiometer experiments, such as AION, MAGIS, and AEDGE, can exceed the shot noise level and thus affect physics searches if not properly subtracted. Note: 44 pages including appendices, 4 figures; v2: different formatting, fixed typos, 28 pages including appendices, 5 figures, agrees with published version

Atom interferometry↗

Bayesian Fit to NOvA Data Subsamples for Three Flavor Oscillation Analysis

NOvA (NuMI Off-Axis $\nu_e$ Appearance) is a long baseline neutrino experiment designed to measure the oscillation of muon neutrinos to electron neutrinos over a distance of 810 km. NOvA uses a near and far detector to observe $\nu_\mu$ disappearance and $\nu_e$ appearance of neutrinos produced by the NuMI beam at Fermilab. NOvA uses a Bayesian analysis framework in addition to its Frequentist method to measure neutrino oscillation parameters such as the mixing angles, mass ordering, and CP-violating phase. We report preliminary results of Bayesian fits to representative NOvA datasets. Comparison of fits to $\nu_\mu$ disappearance and $\nu_e$ appearance enables a cross-check of NOvA results with reactor $\bar{\nu_e}$ disappearance measurements. NOvA also searches for violation of Lorentz invariance by analyzing fits of forward horn current (FHC) versus reverse horn current (RHC) samples. The results validate and advance NOvA's contributions to precision measurements of neutrino properties.

Zhao, Larry [Fermilab]↗

Solar cosmic ray bursts and solar neutrino fluxes

The neutrino flux detected in the C1-Ar experiment seems to respond to the powerful solar cosmic ray bursts. The ground-based detectors, the balloons and the satellites detect about 50% of the bursts of soalr cosmic ray generated on the Sun's visible side. As a rule, such bursts originate from the Western side of the visible solar disk. Since the solar cosmic ray bursts are in opposite phase withthe 11-year galactic cosmic ray cycle which also seems to be reflected by neutrino experiment. The neutrino generation in the bursts will flatten the possible 11-year behavior of the AR-37 production rate, Q, in the Cl-Ar experiment. The detection of solar-flare-generated gamma-quanta with energies above tens of Mev is indicative of the generation of high-energy particles which in turn may produce neutrinos. Thus, the increased Q during the runs, when the flare-generated high energy gamma-quanta have been registered, may be regarded as additional evidence for neutrino geneation in the solar flare processes.

Basilevakaya, G. A.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Neutrino oscillation prospects with a dual-baseline beam from BNL to SNOLAB and SURF

The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW fraction of the EIC proton beam to generate a high-intensity GeV-scale neutrino beam for long-baseline oscillation studies. We have simulated proton-target interactions and optimize the resulting neutrino fluxes for water-based liquid scintillator (WbLS) detectors located at distinct baselines of 900 km and at 2900 km. Oscillation analyses performed with GLoBES show that extended baselines allow access to multiple oscillation maxima, significantly enhancing sensitivity to leptonic CP violation. The study also examines the interplay between matter effects and the intrinsic CP violating phase in shaping observable asymmetries. We note that simplified systematics and no backgrounds are used in this analysis to establish the baseline physics potential. These results suggest that the EIC proton beam could provide a novel and complementary source for precision neutrino physics, extending the scientific reach of the EIC program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

Precise Phase Comparator for Nearly Equal Frequencies

New circuit precisely compares phases of two RF signals nearly equal in frequency, such as two hydrogen-maser frequency standards. Measuring circuit minimizes interactions between two sources. Also stabilized against thermal effects and against noise that could produce erroneous readings. Heat sinking, buffer amplifiers, and low-noise zero-crossing detector make picosecond precision possible.

Reinhardt, V. S.↗

Space processing of electronic materials

The bulk growth of solid solution alloys of mercury telluride and cadmium telluride is discussed. These alloys are usually described by the formula Hg1-xCdxTe, and are useful for the construction of infrared detectors. The electronic energy band gap can be controlled between zero and 1.6 electron volts by adjusting the composition x. The most useful materials are at x approximately 20%, suitable for detection wavelengths of about 10 micrometers. The problems of growing large crystals are rooted in the wide phase diagram of the HgTe-CdTe pseudobinary system which leads to exaggerate segregation in freezing, constitutional supercooling, and other difficulties, and in the high vapor pressure of mercury at the growth temperatures, which leads to loss of stoichiometry and to the necessity of working in strong, pressure resistant sealed containers.

Holland, L. R.↗

On purported observations of partially ionized galactic cosmic rays

Galactic cosmic rays are generally believed to be bare nuclei, fully stripped of all orbital electrons during passage through several g/sq cm of interstellar matter. Over the years there have been numerous reports of so-called 'below-cutoff' Fe-group cosmic rays, with momentum below the minimum required for a fully ionized particle to reach Earth's inner magnetosphere. These reports comprised just a few tens of ions, but stimulated much speculation about partially ionized Galactic cosmic rays, suggesting a nearby source of Galactic cosmic rays. In this Letter we compare these previous reports to new observations of below-cutoff Fe-group ions from passive track detectors exposed for nearly 6 years in low-Earth orbit aboard NASA's Long Duration Exposure Facility (LDEF) satellite. The LDEF fluxes are only a few percent of the previously reported fluxes. This comparison suggests that the flux of below-cutoff ions must be out of phase with the observed solar-cycle variation of other (nonsolar) cosmic-ray sources and/or must strongly increase with decreasing altitude in low-Earth orbit. Both of these features are inconsistent with the notion of partially ionized Galactic cosmic rays as the source of the observed below-cutoff ions.

Tylka, A. J.↗

Comparison of Image Restoration Methods for Lunar Epithermal Neutron Emission Mapping

Orbital measurements of neutrons by the Lunar Exploring Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter are being used to quantify the spatial distribution of near surface hydrogen (H). Inferred H concentration maps have low signal-to-noise (SN) and image restoration (IR) techniques are being studied to enhance results. A single-blind. two-phase study is described in which four teams of researchers independently developed image restoration techniques optimized for LEND data. Synthetic lunar epithermal neutron emission maps were derived from LEND simulations. These data were used as ground truth to determine the relative quantitative performance of the IR methods vs. a default denoising (smoothing) technique. We review and used factors influencing orbital remote sensing of neutrons emitted from the lunar surface to develop a database of synthetic "true" maps for performance evaluation. A prior independent training phase was implemented for each technique to assure methods were optimized before the blind trial. Method performance was determined using several regional root-mean-square error metrics specific to epithermal signals of interest. Results indicate unbiased IR methods realize only small signal gains in most of the tested metrics. This suggests other physically based modeling assumptions are required to produce appreciable signal gains in similar low SN IR applications.

McClanahan, T. P.↗