Vibroacoustic testing of Space Shuttle thermal protection system panels
The modes and acoustic responses of two panels representing Space Shuttle thermal protection panels were investigated. The panels consisted of flat aluminum sheet stiffened longitudinally with hat-section stringers and corrugated supporting panels representing Shuttle ring frame bulkheads. In addition, one panel had 24 tiles of LI900 silica thermal insulation material and a strain isolator pad bonded to the face sheet. Both panels were found to have approximately eight modal frequencies in the 60 to 500 Hz range, where Shuttle acoustic loads are expected to be high. The strain response to a progressive acoustic wave representing a Shuttle spectrum was characterized by the occurrence of larger strains in the direction normal to the stringers than in the direction parallel to the stringers; three modes in the 100 to 400 Hz range contributed significantly to the strain response.