Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induction of pulmonary fibrosis by cerium oxide nanoparticles

Cerium compounds have been used as a diesel engine catalyst to lower the mass of diesel exhaust particles, but are emitted as cerium oxide (CeO{sub 2}) nanoparticles in the diesel exhaust. In a previous study, we have demonstrated a wide range of CeO{sub 2}-induced lung responses including sustained pulmonary inflammation and cellular signaling that could lead to pulmonary fibrosis. In this study, we investigated the fibrogenic responses induced by CeO{sub 2} in a rat model at various time points up to 84 days post-exposure. Male Sprague Dawley rats were exposed to CeO{sub 2} by a single intratracheal instillation. Alveolar macrophages (AM) were isolated by bronchial alveolar lavage (BAL). AM-mediated cellular responses, osteopontin (OPN) and transform growth factor (TGF)-β1 in the fibrotic process were investigated. The results showed that CeO{sub 2} exposure significantly increased fibrotic cytokine TGF-β1 and OPN production by AM above controls. The collagen degradation enzymes, matrix metalloproteinase (MMP)-2 and -9 and the tissue inhibitor of MMP were markedly increased in the BAL fluid at 1 day- and subsequently declined at 28 days after exposure, but remained much higher than the controls. CeO{sub 2} induced elevated phospholipids in BAL fluid and increased hydroxyproline content in lung tissue in a dose- and time-dependent manner. Immunohistochemical analysis showed MMP-2, MMP-9 and MMP-10 expressions in fibrotic regions. Morphological analysis noted increased collagen fibers in the lungs exposed to a single dose of 3.5 mg/kg CeO{sub 2} and euthanized at 28 days post-exposure. Collectively, our studies show that CeO{sub 2} induced fibrotic lung injury in rats, suggesting it may cause potential health effects. -- Highlights: ► Cerium oxide exposure significantly affected the following parameters in the lung. ► Induced fibrotic cytokine OPN and TGF-β1 production and phospholipidosis. ► Caused imbalance of the MMP-9/ TIMP-1 ratio that favors fibrosis. ► Cerium oxide particles were detected in lung tissue and AM. ► Cerium oxide caused lung fibrosis in a dose- and time-dependent manner.

60 APPLIED LIFE SCIENCES↗

Atmospheric Transport of North African Dust-Bearing Supermicron Freshwater Diatoms to South America: Implications for Iron Transport to the Equatorial North Atlantic Ocean

The equatorial North Atlantic Ocean (NAO) is a nutrient-limited ecosystem that relies on the deposition of long-range transported iron (Fe)-containing aerosols to stimulate primary productivity. Using microscopy, we characterized supermicron and supercoarse mode African aerosols transported to the western NAO in boreal winter/spring. In this work, we detected three particle types including African dust, primary biological aerosol particles, and freshwater diatoms (FDs). FDs contained 4% Fe by weight due to surficial dust inclusions that may be susceptible to chemical processing and dissolution. FDs were typically larger than dust particles and comprised 38% of particles between 10 and 18 μm in diameter. The low density, high surface-area-to-volume ratio, and large aspect ratios of FD particles suggest a mechanism by which they can be carried great distances aloft. These same properties likely increase the residence time of FDs in surface waters thereby increasing the time for Fe dissolution and their potential impact on marine biogeochemical cycles.

54 ENVIRONMENTAL SCIENCES↗

Eightfold way from dynamical first principles in strongly coupled lattice quantum chromodynamics

We obtain from first principles, i.e., from the quark-gluon dynamics, the Gell'Mann-Ne'eman baryonic eightfold way energy momentum spectrum exactly in an imaginary-time functional integral formulation of strongly coupled lattice quantum chromodynamics in 3+1 dimensions, with local SU(3){sub c} gauge and global SU(3){sub f} flavor symmetries. We take the hopping parameter {kappa} and the pure gauge coupling {beta} satisfying the strong coupling regime condition 0{<=}{beta}<<{kappa}<<1. The form of the 56 baryon fields emerges naturally from the dynamics and is unveiled using the hyperplane decoupling method. There is no a priori guesswork. In the associated physical quantum mechanical Hilbert space H, spectral representations are derived for the two-baryon functions, which are used to rigorously detect the particles in the energy-momentum spectrum. Using the SU(3){sub f} symmetry, the 56 baryon states admit a decomposition into 8x2 states associated with a spin 1/2 octet and 10x4 states associated with a spin 3/2 decuplet. The states are labeled by the quantum numbers of total hypercharge Y, total isospin I, its third component I{sub 3}, and the value of the quadratic Casimir of SU(3){sub f}; they also carry a label of total spin J and its z component J{sub z}. The total spin operators are defined using {pi}/2 rotations about the spatial coordinate axes and for improper zero momentum baryon states agree with the infinitesimal generators of the continuum. We show there is a partial restoration of continuous rotational symmetry which implies that all the octet (decuplet) masses are the same. For {beta}=0, the masses of the 56 baryon states have the form M=-3 ln {kappa}-3{kappa}{sup 3}/4+{kappa}{sup 6}r({kappa}), with r({kappa}) analytic. There is no mass splitting within the octet (decuplet). However, we find an octet-decuplet mass splitting given by 3{kappa}{sup 6}/4+O({kappa}{sup 7}). For {beta}=0, [M({kappa},{beta})-(-3 ln{kappa})], the non-singular part of the masses, is analytic in {kappa} and {beta} and the mass splitting persists for {beta}{ne}0. For spatial momentum p{ne}0, p=(p{sup 1},p{sup 2},p{sup 3})(set-membership sign)(-{pi},{pi}]{sup 3}, the 56 baryon dispersion curves have the form w({kappa},p)=-3 ln {kappa}-3{kappa}{sup 3}/4+{kappa}{sup 3}{sigma}{sub j=1,2,3}(1-cos p{sup j})/4+r({kappa},p), where r({kappa},p) is of O({kappa}{sup 6}). For the octet, r({kappa},p) is jointly analytic in {kappa} and in each p{sup j} for small |Im p{sup j}|. For each baryon, there is an antibaryon related to it by charge conjugation and with identical spectral properties. It is shown that the spectrum associated with baryons and antibaryons is the only spectrum in the subspace of H with an odd number of quarks, up to near the meson-baryon energy threshold of {approx_equal}-5 ln {kappa}. A new time reflection is found which is used to define a local spin flip symmetry. The spin flip symmetry, together with the usual parity, time reversal, and spatial {pi}/2 rotation symmetries and analytic implicit function arguments, are used to obtain these results. Our method extends to the SU(N){sub f} case to uncover (2N+2){exclamation_point}/[3{exclamation_point}(2N-1){exclamation_point}] baryon states and also to treat mesons. Coupling our baryon results with our similar results for the eightfold mesons (of asymptotic mass -2 ln{kappa}) shows that the model exhibits confinement up to near the two-meson threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PIN Diode Detectors

A review of the application of PIN diodes as radiation detectors in particle counting, X- and {gamma}-ray spectroscopy, medical applications and charged particle spectroscopy is presented. As a practical example of its usefulness, a PIN diode and a low noise preamplifier are included in a nuclear spectroscopy chain for X-ray measurements. This is a laboratory session designed to review the main concepts needed to set up the detector-preamplifier array and to make measurements of X-ray energy spectra with a room temperature PIN diode. The results obtained are compared with those obtained with a high resolution cooled Si-Li detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Ultra-Slow Antiprotons using Micro-channel Plate

Our group ASACUSA-MUSASHI has succeeded in accumulating several million antiprotons and extracting them as monochromatic ultra-slow antiproton beams (10 eV-1 keV) at CERN AD. We have observed ultra-slow antiprotons using micro-channel plates (MCP). The integrated pulse area of the output signals generated when the MCP was irradiated by ultra-slow antiprotons was 6 times higher than that by electrons. As a long-term effect, we also observed an increase in the background rate presumably due to the radioactivation of the MCP surface. Irradiating the antiproton beams on the MCP induces antiproton-nuclear annihilations only on the first layer of the surface. Low-energy and short-range secondary particles like charged nuclear fragments caused by the 'surface nuclear reactions' would be the origin of our observed phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Plasma Clusters: Analysis of dynamical evolution and individual particle interaction

3D plasma clusters (up to 100 particles) have been built inside small (32 mm{sup 3}) plasma volume in gravity. It has been estimated that the external confinement has a negligible influence on the processes inside the clusters. At such conditions the analysis of dynamical evolution and individual particle interactions have shown that the binary interaction among particles in addition to the repelling Coulomb force exhibits also an attractive part. The tendency of the systems to approach the state with minimum energy by rearranging particles inside has been detected. The measured 63 particles' cluster vibrations are in close agreement with vibrations of a drop with surface tension. This indicates that even a 63 particle cluster already exhibits properties normally associated with the cooperative regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Magnetic Spectrometer PRISMA Combined With Large Gamma Arrays

The large solid angle magnetic spectrometer for heavy ions PRISMA was operated at LNL in conjunction with the highly efficient CLARA set-up up to the end of March 2008. The AGATA Demonstrator is being mounted around the target area of PRISMA replacing the CLARA set-up. It will allow to carry out nuclear structure and reaction mechanism studies with better resolution and higher statistics. New detectors for light ions and slow moving heavy ions have been designed for the focal plane of the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unique capabilities of the fusion product separator SOLITAIRE

SOLITAIRE is a powerful tool to study nuclear fusion, having a very large angular acceptance and good rejection of beam particles. This report shows how this device, combined with a high quality ray-tracing code, can give information about both the evaporation residue angular distribution and cross section from a single measurement. Results are shown for {sup 32}S+{sup 89}Y and {sup 58}Ni+{sup 58,60,64}Ni fusion reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Retarding potential and induction charge detectors in tandem for measuring the charge and mass of nanodroplets

The determination of the mass of a nanoparticle via time-of-flight typically requires a direct measurement of its charge. This can be done with a differential retarding potential analyzer and an induction charge detector operating in tandem. The spectrometer described in this article selects a particle with a specified retarding potential from a beam and directs it to an induction charge detector where both its velocity and charge are measured. The retarding potential, velocity, and charge also yield the particle's mass. The particle is analyzed without the need to collect it, and therefore can be employed in a subsequent experiment. The high charge sensitivity of the induction charge detector and the capability for working at low retarding potentials make the characterization of electrosprayed nanodroplets possible for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the MARE experiment in Milan

An international collaboration has grown around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for a direct and calorimetric measurement of the electron antineutrino mass with sub-electronvolt sensitivity.MARE is divided into two phases. The first phase (MARE-1) consists of two independent experiments using the presently available detector technology to reach a sensitivity of m{sub v}{<=}2eV/c{sup 2}. The goal of the second phase (MARE-2) is to achieve a sub-electronvolt sensitivity on the neutrino mass.The Milan MARE-1 experiment is based on arrays of silicon implanted microcalorimeters, produced by NASA/GSFC, with dielectric silver perrhenate absorbers, AgReO{sub 4}. We present here the status of MARE-1 in Milan which is starting data taking with 2 arrays (72 detectors). In this configuration a sensitivity of about 5 eV can be achieved in two years. We describe in details the experimental setup which is designed to host up to 8 arrays (288 detectors). With 8 arrays, two years of measurement would improve the sensitivity to about 3 eV. This talk reports on the activity of the group for the MARE project in Milan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic Ray Muons Timing in the ATLAS Detector

In this talk I discuss the use of calorimeter timing both for detector commissioning and in searches for new physics. In particular I present real and simulated cosmic ray muons data (2007) results for the ATLAS Tile Calorimeter system. The analysis shows that several detector errors such as imperfect calibrations can be uncovered. I also demonstrate the use of ATLAS Tile Calorimeter's excellent timing resolution in suppressing cosmic ray fake missing transverse energy (E{sub T}) in searches for supersymmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Tracking System of Exotic Nuclear Beams for FAIR

New accelerators like SPIRAL2 (GANIL, France) or FAIR (GSI, Germany) will be soon constructed, and they will be able to produce radioactive ion beams (RIB) with high intensities of current (>=10{sup 6} pps). These beams, at low energy, lower than 20 MeV/n, usually have high emittance, which imposes the use of tracking detectors before the target in order to reconstruct the trajectory of the ions. The group of Nuclear Physics at CNA (Centro Nacional de Aceleradores), is in charge of developing a tracking system for the low energy branch of FAIR (the HISPEC/DESPEC project). A collaboration with CEA-SACLAY was established, with the aim of developing, building and testing low pressure Secondary electron Detectors (SeD). Within this proposal we have projected and constructed a new Nuclear Physics Line in the CNA in order to be able to receive any kind of detector tests and the associated nuclear instruments.

43 PARTICLE ACCELERATORS↗