Modeling the impact of high thermal conductivity paper on the performance and life of power transformers
Degradation of insulation paper is a key contributor to the failure of power transformers. Insulation degradation accelerates at elevated temperatures, which highlights the potential for better thermal management to prolong life. While several studies have analyzed the benefits of high thermal conductivity oil for reducing temperatures inside a transformer, this study is an initial assessment of the benefits of high thermal conductivity paper on transformer life. Blending particulates with cellulosic fibers offers a pathway for high thermal conductivity paper (with good dielectric properties), which can reduce internal temperatures. Presently, life extensions that can be achieved by the use of such thermally conducting papers were estimated, with the thermal conductivity of the paper being the key parameter under study. The analytical-numerical thermal model used in this study was validated against experimental measurements in a distribution transformer, adding confidence to the utility of the model. This model was then used to provide estimates of hot-spot temperature reduction resulting from the use of papers with higher thermal conductivity than baseline. Transformer life was predicted conventionally by tracking the degree of polymerization of paper over time, based on an Arrhenius model. Results indicate that increasing the thermal conductivity of paper from 0.2 W/mK (baseline) to 1W/mK reduces the hot spot temperature by 10°C. While degradation significantly depends on the moisture and oxygen content, the model shows that such a temperature reduction can increase life for all conditions, by as much as a factor of three.
Power factor improvement in hydrothermally synthesized Bi{sub 2-x}Sb{sub x}Te{sub 3} (x=1.5) - carbon sphere composites
We report fabrication of compacted Bi{sub 0.5}Sb{sub 1.5}Te{sub 3} composites by adding 1 wt% of carbon spheres in the hydrothermal synthesis. The processing parameter of sintering temperature is investigated in order to optimize the thermoelectric power factor of pressed Bi{sub 0.5}Sb{sub 1.5}Te{sub 3} composites. As a result, we find that the composite sintered at 360 Degree-Sign C shows the best power factor performance among the composites and has a largest power factor of 15.4 {mu}W/cm K{sup 2} at 205 K and 13.5 {mu}W/cm K{sup 2} at 290 K. When compared with the samples without addition of carbon sphere in the hydrothermal synthesis, the composites sintered at 340 Degree-Sign C and 360 Degree-Sign C both surpass the largest power factor of 12.1 {mu}W/cm K{sup 2} at 280 K and 11.9 {mu}W/cm K{sup 2} at 290 K for the 340 Degree-Sign C-sintered counterpart. - Graphical abstract: Compacted Bi{sub 0.5}Sb{sub 1.5}Te{sub 3-{delta}} composites obtained by adding 1 wt% of carbon spheres in the hydrothermal synthesis. The composites sintered at 340 Degree-Sign C and 360 Degree-Sign C both surpass the largest power factor of 12.1 {mu}W/cm K{sup 2} at 280 K and 11.9 {mu}W/cm K{sup 2} at 290 K for the 340 Degree-Sign C-sintered counterpart. Highlights: Black-Right-Pointing-Pointer Fabrication of Bi{sub 0.5}Sb{sub 1.5}Te{sub 3-{delta}} composites. Black-Right-Pointing-Pointer Addition of 1 wt% carbon spheres in the hydrothermal synthesis. Black-Right-Pointing-Pointer Investigation of sintering temperature using encapsulating-and-sintering techniques. Black-Right-Pointing-Pointer 360 Degree-Sign C-sintered composite showing the largest power factor of 15.4 {mu}W/cm K{sup 2} at 205 K. Black-Right-Pointing-Pointer 10-60% improvement over the counterpart without adding carbon spheres.
Statistical Analysis of Abnormal Electric Power Grid Behavior
Pacific Northwest National Laboratory is developing a technique to analyze Phasor Measurement Unit data to identify typical patterns, atypical events and precursors to a blackout or other undesirable event. The approach combines a data-driven multivariate analysis with an engineering-model approach. The method identifies atypical events, provides a plane English description of the event, and the capability to use drill-down graphics for detailed investigations. The tool can be applied to the entire grid, individual organizations (e.g. TVA, BPA), or specific substations (e.g., TVA_CUMB). The tool is envisioned for (1) event investigations, (2) overnight processing to generate a Morning Report that characterizes the previous days activity with respect to previous activity over the previous 10-30 days, and (3) potentially near-real-time operation to support the grid operators. This paper presents the current status of the tool and illustrations of its application to real world PMU data collected in three 10-day periods in 2007.
A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System
This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.
Prediction of Pareto-Optimal Performance Improvements in a Power Conversion System using GaN Devices.
Abstract not provided.
Thermal Modeling of a Multi-Cavity Array Receiver Performance for Concentrating Solar Power Generation
Explore the source record for details and available documents.
PANN: Power Allocation via Neural Networks - Dynamic Bounded-Power Allocation in High Performance Computing
Abstract not provided
Scalable Technologies Achieving Risk-Informed Condition-Based Predictive Maintenance Enhancing the Economic Performance of Operating Nuclear Power Plants
The primary objective of the research presented in this report is to develop scalable technologies that are deployable across plant assets and across the nuclear fleet to achieve risk-informed predictive maintenance (PdM) strategies at commercial nuclear power plants (NPPs). Over the years, the nuclear fleet has relied on labor-intensive and time-consuming preventive maintenance (PM) programs, driving up operation and maintenance (O&M) costs to achieve high capacity factors. A well-constructed risk-informed PdM approach for an identified plant asset has been developed in this research, taking advantage of advancements in data analytics, machine learning (ML), artificial intelligence (AI), physics-informed modeling, and visualization. These technologies would allow commercial NPPs to reliably transition from current labor-intensive PM programs to a technology driven PdM program, eliminating unnecessary O&M costs. The work presented in the report is being developed as part of a collaborative research effort between Idaho National Laboratory and Public Service Enterprise Group Nuclear, LLC. This report (1) reflects the results of work by LWRS Program researchers with PSEG, Nuclear LLC-owned Salem and Hope Creek Nuclear Power Plants; (2) presents utilization of circulating water system (CWS) heterogeneous data and fault modes from both the Salem and Hope Creek nuclear power plant sites to develop salient fault signatures associated with each fault mode; (3) describes the integration of component-level predictive models into a robust system-level model enabled by the federated-transfer learning; (4) describes the development of physics-informed model of circulating water pump and motor; (5) develops a scalable risk and economic model; and (6) outlines the development of a user-centric visualization application. The outcomes presented in this report lays the foundation and provides a much-needed technical basis to focus on explainability and trustworthiness of ML and AI-based technologies, as part of future research.
Improved performance of Wells turbine power take-off for an oscillating water column wave energy converter.
Abstract not provided.
Advanced CO 2 Capture Solvent Systems for Dynamic Power Generation: Quarterly Research Performance Progress Report, QR4 (Q4FY24)
We developed an integrated Computational Fluid Dynamics (CFD) model to simulate the multi-physics coupled cooling process of mixed gas by cold water within a Direct Contact Cooler (DCC) equipped with a rotating packing bed (RPB). The model captures the interactions between fluid dynamics, heat transfer, mass transport, and phase transitions, while accounting for key operational variables such as RPB rotational speed and the mass flow rates of both liquid and gas. The CFD model has been validated using experimental data, specifically by comparing predicted outflow gas and liquid temperatures to measured results. Our findings demonstrate the significant effects of RPB rotational speed and mass flow rates on cooling performance, providing valuable insights for optimizing DCC efficiency in industrial applications.
Optical Imaging of Pulsed Power Outputs for Diode Performance and Dose Variation Analysis
Explore the source record for details and available documents.
Particle Flowability Diagnostic Tool and Evaluation of Hopper Performance for Concentrating Solar Power Relevant Temperatures and Granular Media Including Ratios of Entrained Fines
Explore the source record for details and available documents.
Experimental propulsion performance of a low power pulsed resistojet.
Low power pulsed resistojet applied to orbit and attitude control and station keeping of 500-lb synchronous satellite
Analysis of performances for static power-conditioning systems - Inversion, conversion, and regulation
Analyses of Marzolf tunnel diode inverter, dc to dc regulated converter, and self-regulating dc to sine wave inverter for use in spacecraft power conditioning systems
Cold-air performance of free-power turbine designed for 112-kilowatt automotive gas-turbine engine. 1: Design Stator-vane-chord setting angle of 35 deg
A cold air experimental investigation of a free power turbine designed for a 112-kW automotive gas-turbine was made over a range of speeds from 0 to 130 percent of design equivalent speeds and over a range of pressure ratio from 1.11 to 2.45. Results are presented in terms of equivalent power, torque, mass flow, and efficiency for the design power point setting of the variable stator.
Evaluation of induction motor performance using an electronic power factor controller
The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.
Improving performance of an electrical power expert system with genetic algorithms
An extension to NICBES (the nickel cadmium battery expert system), which is designed to make it more effective as a battery management tool, is described. The extension involves the incorporation of classifier system machine learning techniques into a subsystem of NICBES. The implementation of a user interface for this type of system is discussed.