Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Upgrading Limiting Peak-Power Analysis Techniques with Modern Validation and Uncertainty Quantification for the Advanced Test Reactor

Here, this work demonstrates the acceptability of the 2D deterministic transport code, HELIOS, to replace the legacy diffusion code, PDQ, for computing the peak-power performance parameters of the Advanced Test Reactor (ATR). The 95% Confidence Rule, commonly used in the commercial reactor sector, is explored to develop the so-called “reliability factors” which provide statistical confidence that the peak-power limits within the hottest location along a fuel plate, referred to as the hot-stripe, will not be exceeded. Additionally, an alternative “legacy” methodology was explored that attempts to mimic the exact PDQ analysis process used for defining the peak-power limits. The legacy methodology, involves interpolating power between regions at azimuthal boundaries subtending the regions of interest. In order to apply the 95% Confidence Rule, a statistically significant calculation-to-measurement bias must first be established. Unlike the commercial world where thousands of power observations can be collected every cycle using on-line flux mapping instrumentation, the ATR power distribution must be measured during “depressurized” zero-power measurements using fission wires in polyethylene wands. In 2012, fission wire activation data was collected during a flux run in the Advanced Test Reactor – Critical facility. Also to improve statistical validity, archival data from ATR zero power flux runs from 1977, 1986, and 1994 were digitized from scanned reports and used to create new benchmark models. Borrowing from least-squares adjustment methods commonly used for neutron activation spectroscopy, adjusted fission wire powers were calculated for all four datasets. The mean and standard deviation of the bias between a priori calculated and adjusted wire-powers was then taken as the bias and uncertainty used in the 95% Confidence Rule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing and Expertise for Marine Energy (TEAMER) Program Support (CRADA Final Report)

Virginia Tech (VT) had previously developed a 50 kW AC to DC power converter that is specifically designed to improve the performance and efficiency of wave energy converters (WECs). Through this CRADA, NLR will test the VT power converter via a coupled dynamometer and power electronics test platform. The NLR test platform will be comprised of (1) a rotary dynamometer that will drive a VT provided gearbox and generator, (2) one or more DC regenerative power supplies that provide input power to and take power from the VT supplied power electronics, and (3) a data acquisition system for measurement. NLR will work with VT to develop a test plan, set up the test platform and integrate the test article, perform the testing, and assist in the data analysis.

16 TIDAL AND WAVE POWER↗

Design, fabrication, and testing of wave energy converters (WECs) using different power take-off with mechanical motion rectifier

Power takeoff (PTO) system, the mechanism converts the wave motion into electricity, is still considered to be immature in the wave energy converter(WEC) technology. To overcome this situation, in this paper, a unique PTO concepts and prototype using electromagnetic generator with different mechanical structure using ball screw, is designed to improve the efficiency of extracting ocean wave energy. In addition to that, a novel mechanism called Mechanical Motion Rectifier(MMR) is introduced, this mechanism is capable of converting bi-directional rotation into uni-directional rotation to further improve the efficiency. Furthermore, dynamic model for the WEC prototype has been built to simulate its performance, the effect of the MMR mechanism is also considered in these models to analytically prove that the MMR can increase the efficiency of the system. Finally, the dry test for the prototype has been conducted, the test results are compared with the simulation results to verify the dynamic model and prove the advantage of the MMR mechanism.

16 TIDAL AND WAVE POWER↗

EVSE DERMS Controls [SWR-26-010]

An MQTT (Message Queuing Telemetry Transport) and OCPP (Open Charge Point Protocol) based remote smart charging controller framework for AC Electric Vehicle Supply Equipments (EVSEs). The code in this repo allows for the National Laboratory of the Rockies (NLR) controls to interface with the real Distributed Energy Resource Management System (DERMS) and EVSEs in NLR's ESIF Optimization and Control Laboratory (OCL). Different charge management algorithms can be tested to determine which power allocation method is most effective with the overall goal of demonstrating clear and well documented test results as well as providing functional control algorithms which could be utilized to provide effective smart charge management (SCM) at EV charging stations. Different power allocation methods are programmed in lab_demo_controller.py and include allocation based on first come first served, equal sharing, state of charge (SOC), priority factors, and behind the meter control methods.

Panossian, Nadia [National Laboratory of the Rocki↗

In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Triton Point Absorber 1:30 Scale Tank Test Data for Extreme Wave Environments

This content model summarizes laboratory testing data for the Oscilla Power Triton WEC conducted at 1:30 scale. The WEC was tested in large operational waves and in extreme wave conditions along the 1 in 50 year wave contour at the DoE reference location in Humbolt Bay, CA. The WEC was tested in both its operational configuration and its survival configuration. The aims of the dataset are (i) To demonstrate that the survival strategy developed for the Triton WEC improves survivability and reduces loads in extreme wave environments, and (ii) To determine the ultimate design loads for the WEC.

16 TIDAL AND WAVE POWER↗

Design and installation of a ferromagnetic wall in tokamak geometry

Low-activation ferritic steels are leading material candidates for use in next-generation fusion development experiments such as a prospective component test facility and DEMO power reactor. Understanding the interaction of plasmas with a ferromagnetic wall will provide crucial physics for these facilities. In order to study ferromagnetic effects in toroidal geometry, a ferritic wall upgrade was designed and installed in the High Beta Tokamak–Extended Pulse (HBT-EP). Several material options were investigated based on conductivity, magnetic permeability, vacuum compatibility, and other criteria, and the material of choice (high-cobalt steel) is characterized. Installation was accomplished quickly, with minimal impact on existing diagnostics and overall machine performance, and initial results demonstrate the effects of the ferritic wall on plasma stability.

42 ENGINEERING↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

Characterization and Modeling of High-Intensity Evolution in the SNS Beam Test Facility

Modern high-power accelerators are charged with delivering reliable beam with low losses. Resolving the complex dynamics arising from space charge and nonlinear forces requires detailed models of the accelerator and particle-in-cell simulation. There has historically been discrepancy between simulated and measured beam distributions, particularly at the low-density halo level. The Beam Test Facility (BTF) at the Spallation Neutron Source is outfitted to study beam evolution in a high-power linear accelerator MEBT. This includes capability for high-dimensional measurements of the post-RFQ beam distribution, including interplane correlations that may be the key to accurate simulation. Beam is transported through a 4.6 m FODO channel (9.5 cells) to a second distribution measurement stage. Plans for validating simulations against BTF measurements of beam evolution in the FODO channel are discussed.

Ruisard, Kiersten↗

Power Take-off System for Marine Renewable Devices, CRADA Number CRD-14-566

Ocean Renewable Power Company (ORPC) proposes a project to develop and test innovative second-generation power take-off (PTO) components for the U.S. Department of Energy's 2013 FOA: Marine and Hydrokinetic System Performance Advancement, Topic Area 2 (Project). Innovative PTO components will include new and improved designs for bearings, couplings and a subsea electrical generator. Specific project objectives include the following: (1) Develop components for an advanced PTO suitable for MHK devices; (2) Bench test these components; (3) Assess the component and system performance benefits; (4) Perform a system integration study to integrate these components into an ORPC hydrokinetic turbine. National Renewable Energy Laboratory (NREL) will participate on the ORPC lead team to review design of the generator and will provide guidance on the design. Based on inputs from the project team, NREL will also provide an economic analysis of the impacts of the proposed system performance advancements.

17 WIND ENERGY↗

Acciona Solar Technology Performance Evaluation: Cooperative Research and Development Final Report, CRADA Number CRD-10-384

Under this agreement, NREL will work with Acciona to conduct joint testing, evaluation, and data collection related to Acciona's solar technologies and systems. This work includes, but is not limited to, testing and evaluation of solar component and system technologies, data collection and monitoring, performance evaluation, reliability testing, and analysis. This work will be conducted at Acciona's Nevada Solar One (NSO) power plant and NREL test facilities. Specific projects will be developed on a task order basis. Each task order will identify the name of the project and deliverables to be produced under the task order. Each task order will delineate an estimated completion date based on a project's schedule. Any reports developed under this CRADA must be reviewed by both NREL and Acciona and approved by each organization prior to publication of results or documents.

14 SOLAR ENERGY↗

Uranium Annealing Analysis

This report describes tests completed at INL on depleted uranium samples of surplus shield block from the Zero Power Physics Reactor (ZPPR). Tests involved annealing individual samples in molten salt for periods ranging from 30 minutes to 4 hours, with variations on conditions as described in the report. Some samples were also left as cast. After annealing, samples were cooled either in water or air. Annealing and as-cast samples were measured and analyzed for hardness, oxide layer, and rind thickness.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ground Testing a Nuclear Thermal Rocket: Design of a sub-scale demonstration experiment

In 2008, the NASA Mars Architecture Team found that the Nuclear Thermal Rocket (NTR) was the preferred propulsion system out of all the combinations of chemical propulsion, solar electric, nuclear electric, aerobrake, and NTR studied. Recently, the National Research Council committee reviewing the NASA Technology Roadmaps recommended the NTR as one of the top 16 technologies that should be pursued by NASA. One of the main issues with developing a NTR for future missions is the ability to economically test the full system on the ground. In the late 1990s, the Sub-surface Active Filtering of Exhaust (SAFE) concept was first proposed by Howe as a method to test NTRs at full power and full duration. The concept relied on firing the NTR into one of the test holes at the Nevada Test Site which had been constructed to test nuclear weapons. In 2011, the cost of testing a NTR and the cost of performing a proof of concept experiment were evaluated.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of PCMI Simulation Using the Multidimensional Multiphysics BISON Fuel Performance Code

Since 2008, the Idaho National Laboratory (INL) has been developing a next-generation nuclear fuel performance code called BISON. BISON is built using INL’s Multiphysics Object-Oriented Simulation Environment, or MOOSE. MOOSE is a massively parallel, finite element-based framework to solve systems of coupled non-linear partial differential equations using the Jacobian-FreeNewton Krylov (JFNK) method. MOOSE supports the use of complex two- and three-dimensional meshes and uses implicit time integration, which is important for the widely varied time scales in nuclear fuel simulation. MOOSE’s object-oriented architecture minimizes the programming required to add new physics models. BISON has been applied to various nuclear fuel problems to assess the accuracy of its 2D and 3D capabilities. The benchmark results used in this assessment range from simulation results from other fuel performance codes to measurements from well-known and documented reactor experiments. An example of a well-documented experiment used in this assessment is the Third Risø Fission Gas Project, referred to as “Bump Test GE7”, which was performed on rod ZX115. This experiment was chosen because it allows for an evaluation of several aspects of the code, including fully coupled thermo-mechanics, contact, and several nonlinear material models. Bump Test GE7 consists of a base-irradiation period of a full-length rod in the Quad-Cities-1 BWR for nearly 7 years to a burnup of 4.17% FIMA. The base irradiation test is followed by a “bump test” of a sub-section of the original rod. The bump test takes place in the test reactor DR3 at Risø in a water-cooled HP1 rig under BWR conditions where the power level is increased by about 50% over base irradiation levels in the span of several hours. During base irradiation, the axial power profile is flat. During the bump test, the axial power profile changes so that the bottom half of the rod is at approximately 50% higher power than at the base irradiation level, while the power at the top of the rod is at about 20% of the base irradiation power level. 2D BISON simulations of the Bump Test GE7 were run using both discrete and smeared pellet geometry. Comparisons between these calculations and experimental measurements are presented for clad diameter and elongation after the base irradiation and clad profile along the length of the test section after the bump test. Preliminary comparisons between calculations and measurements are favorable, supporting the use of BISON as an accurate multiphysics fuel simulation tool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters

Zenergy Power has successfully designed, built, tested, and installed in the US electrical grid a saturable reactor Fault Current Limiter. Beginning in 2007, first as SC Power Systems and from 2008 as Zenergy Power, Inc., ZP used DOE matching grant and ARRA funds to help refine the design of the saturated reactor fault current limiter. ZP ultimately perfected the design of the saturated reactor FCL to the point that ZP could reliably design a suitable FCL for most utility applications. Beginning with a very basic FCL design using 1G HTS for a coil housed in a LN2 cryostat for the DC bias magnet, the technology progressed to a commercial system that was offered for sale internationally. Substantial progress was made in two areas. First, the cryogenics cooling system progressed from a sub-cooled liquid nitrogen container housing the HTS coils to cryostats utilizing dry conduction cooling and reaching temperatures down to less than 20 degrees K. Large, round cryostats with warm bore diameters of 1.7 meters enabled the design of large tanks to hold the AC components. Second, the design of the AC part of the FCL was refined from a six legged spider design to a more compact and lighter design with better fault current limiting capability. Further refinement of the flux path and core shape led to an efficient saturated reactor design requiring less Ampere-turns to saturate the core. In conclusion, the development of the saturable reactor FCL led to a more efficient design not requiring HTS magnets and their associated peripheral equipment, which yielded a more economical product in line with the electric utility industry expectations. The original goal for the DOE funding of the ZP project Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters was to stimulate the HTS wire industry with, first 1G, then 2G, HTS wire applications. Over the approximately 5 years of ZP's product development program, the amount of HTS wire employed per FCL and its cost as a percentage of the total FCL product content had not dropped substantially from an unsustainable level of more than 50% of the total cost of the FCL, nor had the availability increased (today the availability of 2G wire for commercial applications outside of specific partnerships with the leading 2G wire manufacturers is extremely limited). ZP had projected a very significant commercial potential for FCLs with higher performance and lower costs compared to the initial models built with 1G wire, which would come about from the widespread availability of low-cost, high-performance 2G HTS wire. The potential for 2G wires at greatly reduced performance-based prices compared to 1G HTS conductor held out the potential for the commercial production of FCLs at price and performance levels attractive to the utility industry. However, the price of HTS wire did not drop as expected and today the available quantities of 2G wire are limited, and the price is higher than the currently available supplies of 1G wire. The commercial option for ZP to provide a reliable and reasonably priced FCL to the utility industry is to employ conventional resistive conductor DC electromagnets to bias the FCL. Since the premise of the original funding was to stimulate the HTS wire industry and ZP concluded that copper-based magnets were more economical for the foreseeable future, DOE and ZP decided to mutually terminate the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗