Search NASA⌕ Search

SEARCH · Search NASA

Results for “Program Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Ongoing Cooperative Engagement Facilitates Agile Pandemic and Outbreak Response: Lessons Learned Through Cooperative Engagement Between Uganda and the United States

Pathogens threaten human lives and disrupt economies around the world. This has been clearly illustrated by the current COVID-19 pandemic and outbreaks in livestock and food crops. Here, to manage pathogen emergence and spread, cooperative engagement programs develop and strengthen biosafety, biosecurity, and biosurveillance capabilities among local researchers to detect pathogens. In this case study, we describe the efforts of a collaboration between the Los Alamos National Laboratory and the Uganda Virus Research Institute, the primary viral diagnostic laboratory in Uganda, to implement and ensure the sustainability of sequencing for biosurveillance. We describe the process of establishing this capability along with the lessons learned from both sides of the partnership to inform future cooperative engagement efforts in low- and middle-income countries. We found that by strengthening sequencing capabilities at the Uganda Virus Research Institute before the COVID-19 pandemic, the institute was able to successfully sequence SARS-CoV-2 samples and provide data to the scientific community. We highlight the need to strengthen and sustain capabilities through in-country training, collaborative research projects, and trust.

59 BASIC BIOLOGICAL SCIENCES↗

Application of the AMPLE cluster-and-truncate approach to NMR structures for molecular replacement

Processing of NMR structures for molecular replacement by AMPLE works well. AMPLE is a program developed for clustering and truncating ab initio protein structure predictions into search models for molecular replacement. Here, it is shown that its core cluster-and-truncate methods also work well for processing NMR ensembles into search models. Rosetta remodelling helps to extend success to NMR structures bearing low sequence identity or high structural divergence from the target protein. Potential future routes to improved performance are considered and practical, general guidelines on using AMPLE are provided.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pushing the limits of spectroscopy with S 3

A new LINAG accelerator is developed for production of high intensity deuteron beam for the SPIRAL2 project. It will also deliver unprecedented high intensity stable beams that can be used for direct reactions on a target. The Super Separator Spectrometer (S{sup 3}) is designed to open with these beams new horizons for the physics of rare nuclei and low production cross-section nuclei at the extreme limits of the nuclear chart. The S{sup 3} focal-plane detection is one of the major equipments in this framework. A research and development program has been launched in order to get the best setup according to the three main physics cases: Synthesis of new Super Heavy Elements, Spectroscopy of Very and Super Heavy Elements and Spectroscopy of neutron-deficient nuclei around {sup 100}Sn. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quench Detection for High-Temperature Superconductor Conductors Using Acoustic Thermometry

Detecting local heat-dissipating zones in high-temperature superconductor (HTS) magnets is a challenging task due to slow propagation of such zones in HTS conductors. For long conductor lengths, voltage-based methods may not provide a sufficient sensitivity or redundancy, and therefore nonvoltage-based detection alternatives are being sought. One of those is the recently proposed method of Eigen Frequency Thermometry (EFT), which is an active acoustic technique for a fast and nonintrusive detection of 'hot spots,' utilizing temperature dependence of the conductor elastic moduli. In this work, we demonstrate the efficiency of EFT for detecting localized heating in a 1.2-m-long sample of REBCO tape immersed in liquid nitrogen, and benchmark sensitivity of the acoustic detection with respect to voltage, hot spot temperature, and power dissipation in the conductor. Modifying the original technique for differential mode of operation enables a much improved sensitivity, and adds a hot spot localization capability. Furthermore, we adapt this technique to subscale coils wound with REBCO CORC conductor built in the framework of U.S. Magnet Development Program. A successful thermal-based detection of dissipation onset at the critical current for a two-layer canted CORC dipole assembly is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The HL-LHC Low-β Quadrupole Magnet MQXF: From Short Models to Long Prototypes

Among the components to be upgraded in LHC interaction regions for the HiLumi-LHC projects are the inner triplet (or low-β) quadrupole magnets, denoted as Q1, Q2a, Q2b, and Q3. Here, the new quadrupole magnets, called MQXF, are based on Nb3Sn superconducting magnet technology and operate at a gradient of 132.6 T/m, with a conductor peak field of 11.4 T. Q1 and Q3 are composed of magnets (called MQXFA) fabricated by the U.S. Accelerator Upgrade Project (AUP), with a magnetic length of 4.2 m. Q2a and Q2b consist of magnets (called MQXFB) fabricated by CERN, with a magnetic length of 7.15 m. After a series of short models, constructed in close collaboration by the US and CERN, the development program is now entering in the prototyping phase, with CERN on one side and BNL, FNAL, and LBNL on the other side assembling and testing their first long magnets We provide in this paper a description of the status of the MQXF program, with a summary of the short model test results, including quench performance, and mechanics, and an update on the fabrication, assembly, and test of the long prototypes.

43 PARTICLE ACCELERATORS↗

Mechanical Utility Structure for Testing High Field Superconducting Dipole Magnets

The U.S. Magnet Development Program (MDP) collaboration is designing a utility mechanical structure for testing various high-field superconducting dipole coils. The design uses a shell-based structure concept, which allows applying preload in two steps: During a room temperature assembly and during a cool down to a cryogenic temperature. The structure is designed to accommodate various coil designs - including Nb 3 Sn Cosine Theta (CT) and Canted CT magnets as well as hybrid magnets with high temperature superconductor cables. Superconducting coils, enclosed by bolted pads to form an octagonal coil pack, will be inserted into a reusable yoke-shell subassembly and precisely preloaded during the assembly using a bladder-and-key technology. Due to a differential thermal contraction between an external aluminum shell and the magnet core, the coil preload increases during the cool down up to level required for 17-T excitation. Such a reusable structure will serve as a testing fixture supporting goals of the MDP program, decreasing cost and simplifying coil performance testing at different preload levels. We present a finite-element analysis of the structure preloading various coil designs and examine the predicted coil stress at each step of the magnet assembly and excitation.

43 PARTICLE ACCELERATORS↗

Fabrication of Bi-2212 Canted-Cosine-Theta Dipole Prototypes

The U.S. Magnet Development Program (MDP) is exploring the possibility of combining low-and higherature superconductor technologies, using cosine-theta and canted-cosine-theta (CCT) Nb3Sn dipole magnets together with Bi-2212 CCT inserts, with the ultimate goal of constructing a 20-T dipole. The MDP short-term goal is a Bi-2212 CCT insert capable of reaching 5 T in the bore when operating as a stand-alone and 3 T when operating under a background field of 15 T. This paper reports on the fabrication of our BIN4 dipole magnet and our BIN5a and BIN5b coils, designed and built at the Lawrence Berkeley National Laboratory to address potential fabrication issues of Bi-2212 coils and verify the design of our 18-20-T dipole magnet. BIN4 is a two-layer 50-cm-long CCT magnet that uses a nine-strand Rutherford cable made with 0.8-mm-diameter Bi-2212 strands. Its goal is to investigate critical current, insulation integrity, manufacturing challenges, and quench protection issues after heat treating both layers together under oxygen at standard atmosphere (1 bar). BIN5a and BIN5b are two identical coils, similar to the outer layer of BIN4, with the difference that the length is 39 cm, and they will undergo 50-bar overpressure processing heat treatment. Finally, BIN5 coils are made from the state-of-the-art strand with an engineering critical current density of 1150 A/mm 2 at 4.2 K and 5 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of a High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory, together with Lawrence Berkeley National Laboratory, is building a new High Field Vertical Magnet Test Facility (HFVMTF) to be situated in the Magnet Test Facility at Fermilab. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences, and will serve as a superconducting cable test facility for both communities. The background magnetic field for test samples is 15 T and will be produced by a magnet provided by LBNL operating at 1.9 K in superfluid helium. The samples will be placed in the background magnetic field, cooled to between 4.5 K and a user-specified upper limit, and will be powered with a super-conducting transformer at up to 100 kA. Additionally, this facility will be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program. Presently, the various tasks of the project are at different stages of execution, from conceptual to ready-for-construction designs. Here, this paper describes the parameters and design status of the pit construction, cryostat, heat exchanger, lambda plate, power system, and quench protection and monitoring systems of the facility.

43 PARTICLE ACCELERATORS↗

MDPCT1 Quench Data and Performance Analysis

MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two tests (and three thermal cycles) shows the path to address challenges brought by the first four-layer magnet tested at FNAL. This paper presents the analysis of quench data along with diagnostic features and complementary measurements taken in support of the magnet performance analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. The background magnetic field of 15 T in the HFVMTF will be produced by a magnet provided by LBNL. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES), and will serve as a superconducting cable test facility in high magnetic fields and a wide range of temperatures for HEP and FES communities. This facility will also be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program (MDP). The paper describes the status of the facility, including construction, cryostat designs, top and lambda plates, and systems for powering, and quench protection and monitoring.

43 PARTICLE ACCELERATORS↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is currently constructing a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing High Temperature Superconducting (HTS) cables under high magnetic fields. This facility is expected to offer capabilities similar to those of EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15 T will be generated by a magnet supplied by Lawrence Berkeley National Laboratory. The primary function of HFVMTF will be to serve as a superconducting cable test facility, facilitating tests under high magnetic fields and a broad spectrum of cryogenic temperatures. Additionally, the facility will be utilized for testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Program (MDP). This paper provides a comprehensive description of the current status of two pivotal components of the facility: the Top/Lambda Plates Assembly and the Anticryostat for the Test Sample Holder. The latter will serve as a principal interface component connecting cable test samples with the facility's cryostat.

43 PARTICLE ACCELERATORS↗

Elliptic Aperture CCT Coils for HTS Dipole Magnets

High-temperature REBa$_{2}$Cu$_{3}$O$_{7-x}$ (REBCO) superconductors are a route to increase the field of accelerator magnets beyond the 15-16T practical limit of Nb$_{3}$Sn. REBCO cabled in a CORC geometry is a promising fit for this application, enabling the design of low inductance magnets with conductor transposition. However, the use of CORC in coils with the tight conductor bending radii typical of accelerator magnets remains a key challenge, with on-going research both on the conductor development and coil design fronts seeking to address this issue. Here, in this work we explore the tradeoffs between circular and elliptic aperture canted-cosine-theta (CCT) coils when the conductor minimum bending radius is a key consideration, concluding that aperture ellipticity is an important free parameter in the optimization of magnetically efficient CORC dipole magnets. In particular, we show that elliptic bore designs enable a regime of smaller aperture HTS coils, an important result for LTS-HTS hybrid magnets and more generally for accelerator applications benefiting from non-circular magnet apertures. To this end we present an elliptic aperture dipole design optimized for hybrid testing within the US Magnet Development Program (US-MDP) and share 77 K test results of a prototype coil which provides first experimental confirmation of the advantages.

Brouwer, L. [Lawrence Berkeley National Laboratory↗

Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

A combined time projection chamber-Cherenkov (TPCC) prototype detector has been developed as part of the detector research and development program for a future electron-ion collider (E!C). The prototype was tested at the Fermilab test beam facility (FTBF) to provide a proof of the principle to demonstrate the ability to measure particle tracks and provide particle identification (P!D) information within a common detector volume. The time projection chamber (TPC) portion consists of a 10 × 10 × 10 cm 3 field cage, which delivers charge from tracks to a quadruple gas electron multiplier (GEM) with zigzag-shaped charge collection anodes. The Cherenkov portion consists of a photosensitive quadruple GEM detector with a Cs! photocathode. As tracks pass through the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the Cs! photocathode. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF 4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, including the position resolution as well as the particle id capabilities of the detector, are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Algae Foundation® and Algae Technology Educational Consortium

Abstract The Algae Foundation established in February 2013 has developed a diverse portfolio of algal‐based education and workforce development programs covering education levels from kindergarten through college, aquaculture extension, and free online courses. The Algae Foundation created the Algae Technology Educational Consortium (ATEC) with five major foci including community college certificate program in algae cultivation; community college curriculum adopted for algal biotechnology degree programs; Algal Massive Open Online Courses (Algal MOOCs); Algae Academy, a kindergarten to 12th grade STEM curriculum initiative; and aquaculture extension education through the Algae Cultivation Extension Short courses (ACES). The results include the education and training of over 102,000 students, aquaculturists, entrepreneurs, and bioeconomy‐based professionals aged 8–75 years in all 50 U.S. states and 66 countries. ATEC has completed agreements with 21 community colleges and universities located in Arizona, California, Connecticut, Hawaii, Louisiana, Maine, New Mexico, North Carolina, Oregon, Texas, and Washington. The first ATEC‐sponsored certificate degree program graduation was in May 2018. The Algae MOOC #1 has had over 15,752 students enrolled. ATEC initiated the Algae Academy in spring 2016 in Carlsbad, CA, and expanded to serving over 34,000 students in 46 states during the academic year 2019–2020. ACES has enrolled over 1,550 students from 66 countries.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the Potential for Remote In-Process Monitoring of Tool Wear in Friction Stir Welding of Stainless Steel

A wear characterization study was performed to determine the useful lifetime of Polycrystalline Cubic Boron Nitride tooling for the friction stir welding (FSW) of stainless steel samples in support of a nuclear repair welding research and development program. In-situ and ex-situ laser profilometry were utilized as primary methods of monitoring tool geometry degradation, and volumetric defects were detected through both non-destructive and destructive techniques, as repeated welds of a standard sample configuration were produced. The spectral content of weld forces were examined to search for indications of evolving material flow conditions, caused by significant tool wear, that would result in the formation of defects, and an artificial neural network was trained and evaluated as a means of automatically detecting these conditions. Here, the resulting performance constituted a successful demonstration of in-process monitoring of tool wear and weld quality in FSW of a high melting temperature, high hardness material.

36 MATERIALS SCIENCE↗

Performance of a 512 x 512 Gated CMOS Imager with a 250 ps Exposure Time

We describe the performance of a 512x512 gated CMOS read out integrated circuit (ROIC) with a 250 ps exposure time. A low-skew, H-tree trigger distribution system is used to locally generate individual pixel gates in each 8x8 neighborhood of the ROIC. The temporal width of the gate is voltage controlled and user selectable via a precision potentiometer. The gating implementation was first validated in optical tests of a 64x64 pixel prototype ROIC developed as a proof-of-concept during the early phases of the development program. The layout of the H-Tree addresses each quadrant of the ROIC independently and admits operation of the ROIC in two modes. If “common mode” triggering is used, the camera provides a single 512x512 image. If independent triggers are used, the camera can provide up to four 256x256 images with a frame separation set by the trigger intervals. The ROIC design includes small (sub-pixel) optical photodiode structures to allow test and characterization of the ROIC using optical sources prior to bump bonding. Reported test results were obtained using short pulse, second harmonic Ti:Sapphire laser systems operating at λ~ 400 nm at sub-ps pulse widths.

47 OTHER INSTRUMENTATION↗

TH-E-19A-01: Quality and Safety in Radiation Therapy

Clinical radiotherapy data clearly demonstrate the link between the quality and safety of radiation treatments and the outcome for patients. The medical physicist plays an essential role in this process. To ensure the highest quality treatments, the medical physicist must understand and employ modern quality improvement techniques. This extends well beyond the duties traditionally associated with prescriptive QA measures. This session will review the current best practices for improving quality and safety in radiation therapy. General elements of quality management will be reviewed including: what makes a good quality management structure, the use of prospective risk analysis such as FMEA, and the use of incident learning. All of these practices are recommended in society-level documents and are incorporated into the new Practice Accreditation program developed by ASTRO. To be effective, however, these techniques must be practical in a resource-limited environment. This session will therefore focus on practical tools such as the newly-released radiation oncology incident learning system, RO-ILS, supported by AAPM and ASTRO. With these general constructs in mind, a case study will be presented of quality management in an SBRT service. An example FMEA risk assessment will be presented along with incident learning examples including root cause analysis. As the physicist's role as “quality officer” continues to evolve it will be essential to understand and employ the most effective techniques for quality improvement. This session will provide a concrete overview of the fundamentals in quality and safety. Learning Objectives: Recognize the essential elements of a good quality management system in radiotherapy. Understand the value of incident learning and the AAPM/ASTRO ROILS incident learning system. Appreciate failure mode and effects analysis as a risk assessment tool and its use in resource-limited environments. Understand the fundamental principles of good error proofing that extends beyond traditional prescriptive QA measures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-778: Use of the 2D MatriXX Detector for Measuring Scanned Ion Beam Parameters

Purpose: The quality assurance (QA) procedure has to check the most relevant beam parameters to ensure the delivery of the correct dose to patients. Film dosimetry, which is commonly used for scanned ion beam QA, does not provide immediate results. The purpose of this work is to answer whether, for scanned ion beam therapy, film dosimetry can be replaced with the 2D MatriXX detector as a real-time tool. Methods: MatriXX, equipped with 32×32 parallel plate ion-chambers, is a commercial device intended for pre-treatment verification of conventional radiation therapy.The MatriXX, placed at the isocenter, and GAFCHROMIC films, positioned on the MatriXX entrance, were exposed to 131.44 MeV proton and 221.45 MeV/u Carbon-ion beams.The OmniPro-I’mRT software, applied for the data taking of MatriXX, gives the possibility of acquiring consecutive snapshots. Using the NI LabVIEW, the data from snapshots were logged as text files for further analysis. Radiochromic films were scanned with EPSON scanner and analyzed using software programs developed in-house for comparative purposes. Results: The field dose uniformity, flatness, beam position and beam width were investigated. The field flatness for the region covering 6×6 cm{sup 2} square field was found to be better than 2%. The relative standard deviations, expected to be constant over 2×2, 4×4 and 6×6 pixels from MatriXX measurement gives a uniformity of 1.5% in good agreement with the film results.The beam center position is determined with a resolution better than 200 µm for Carbon and less than 100 µm for proton beam.The FWHM determination for a beam wider than 10 mm is satisfactory, whilst for smaller beams the determination is uncertain. Conclusion: Precise beam position and fast 2D dose distribution can be determined in real-time using MatriXX detector. The results show that MatriXX is quick and accurate enough to be used in charged-particle therapy QA.

60 APPLIED LIFE SCIENCES↗