Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Oral PEG 15-20 protects the intestine against radiation : role of lipid rafts.

Intestinal injury following abdominal radiation therapy or accidental exposure remains a significant clinical problem that can result in varying degrees of mucosal destruction such as ulceration, vascular sclerosis, intestinal wall fibrosis, loss of barrier function, and even lethal gut-derived sepsis. We determined the ability of a high-molecular-weight polyethylene glycol-based copolymer, PEG 15-20, to protect the intestine against the early and late effects of radiation in mice and rats and to determine its mechanism of action by examining cultured rat intestinal epithelia. Rats were exposed to fractionated radiation in an established model of intestinal injury, whereby an intestinal segment is surgically placed into the scrotum and radiated daily. Radiation injury score was decreased in a dose-dependent manner in rats gavaged with 0.5 or 2.0 g/kg per day of PEG 15-20 (n = 9-13/group, P < 0.005). Complementary studies were performed in a novel mouse model of abdominal radiation followed by intestinal inoculation with Pseudomonas aeruginosa (P. aeruginosa), a common pathogen that causes lethal gut-derived sepsis following radiation. Mice mortality was decreased by 40% in mice drinking 1% PEG 15-20 (n = 10/group, P < 0.001). Parallel studies were performed in cultured rat intestinal epithelial cells treated with PEG 15-20 before radiation. Results demonstrated that PEG 15-20 prevented radiation-induced intestinal injury in rats, prevented apoptosis and lethal sepsis attributable to P. aeruginosa in mice, and protected cultured intestinal epithelial cells from apoptosis and microbial adherence and possible invasion. PEG 15-20 appeared to exert its protective effect via its binding to lipid rafts by preventing their coalescence, a hallmark feature in intestinal epithelial cells exposed to radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Protection settings optimizer

SAND2023-06672O The Protection Settings Optimizer (PSO) uses system and fault data as inputs to formulate the problem of calculating relay settings as a mixed integer, nonlinear optimization problem (MINLP). The MINLP is solved using a genetic algorithm-based optimizer that attempts to find settings to reduce the relay operating times. The PSO protects the power system by using the steady-state fault voltages and currents, which then calculates the optimal device setting to protect the power system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Patel, Trupal↗

ADoSPSiQS (Automated Detection of Symmetry-Protected Subspaces in Quantum Simulations ) [SWR-23-55]

Symmetry-protected subspaces in quantum systems are subspaces demarcated by a conserved quantity of that quantum system. We introduce two classical algorithms, which efficiently compute and elucidate features of these subspaces. The first algorithm explores the entire symmetry-protected subspace of an initial state in time complexity linear to the size of the subspace by closing local basis state-to-basis state transitions. The second algorithm determines, with bounded error, if a given measurement outcome of a dynamically-generated state is within the symmetry-protected subspace of the state in which the dynamical system is initialized. This software is paired with the paper of the same name at https://arxiv.org/pdf/2302.08586.pdf.

Rotello, Caleb↗

Pharmacologic or genetic interference with atrogene signaling protects against glucocorticoid-induced musculoskeletal and cardiac disease

Despite their beneficial actions as immunosuppressants, glucocorticoids (GC) have devastating effects on the musculoskeletal and cardiac systems, as long-term treated patients exhibit high incidence of falls, bone fractures, and cardiovascular events. Herein, we show that GC upregulate simultaneously in bone, skeletal muscle, and the heart the expression of E3 ubiquitin ligases (atrogenes), known to stimulate the proteasomal degradation of proteins. Activation of vitamin D receptor (VDR) signaling with the VDR ligands calcitriol or eldecalcitol prevented GC-induced atrogene upregulation in vivo and ex vivo in bone/muscle organ cultures and preserved tissue structure/mass and function of the 3 tissues in vivo. Direct pharmacologic inhibition of the proteasome with carfilzomib also conferred musculoskeletal protection. Genetic loss of the atrogene MuRF1-mediated protein ubiquitination in ΔRING mice afforded temporary or sustained protection from GC excess in bone or skeletal and heart muscle. We concluded that the atrogene pathway downstream of MuRF1 underlies GC action in bone, muscle, and the heart, and it can be pharmacologically or genetically targeted to confer protection against the damaging actions of GC simultaneously in the 3 tissues.

Research & Experimental Medicine↗

Validation of a lightning protection system for a fusion-welded thermoplastic composite wind turbine blade tip

Fusion welding for thermoplastic composite wind turbine blades is being investigated as a replacement for adhesives in bond lines to reduce manufacturing time and cost and to promote ease of recyclability. Resistance welding uses an electrically conductive material, such as carbon fiber, embedded in the bond line to heat the joining surfaces and fuse them together under pressure. One main challenge with fusion joining for large wind blades is the ability to use this conductive heating element in the bond line while still protecting the blade from the catastrophic effects of a lightning strike. This paper outlines the design and manufacturing of a lightning protection system for a 5-m-long thermally welded blade tip. The outcomes of high voltage and high current lightning testing applied to the 5 m blade tip show that the proposed design was able to protect the fusion welded bond lines from significant lightning damage.

17 WIND ENERGY↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗

R&D ERL: Machine Protection System

The Machine Protection System (MPS) is a device-safety system that is designed to prevent damage to hardware by generating interlocks, based upon the state of input signals generated by selected sub-system. It exists to protect key machinery such as the 50 kW and 1 MW RF Systems. When a fault state occurs, the MPS is capable of responding with an interlock signal within several microseconds. The Machine Protection System inputs are designed to be fail-safe. In addition, all fault conditions are latched and time-stamped. The ERL MPS is based on a National Instruments hardware platform, and is programmed by utilizing National Instruments development environment for a visual programming language.

43 PARTICLE ACCELERATORS↗

Y-12 Groundwater Protection Program Groundwater And Surface Water Sampling And Analysis Plan For Calendar Year 2011

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2011 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2011 will be in accordance with requirements of DOE Order 540.1A and the following goals: (1) to protect the worker, the public, and the environment; (2) to maintain surveillance of existing and potential groundwater contamination sources; (3) to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; (4) to identify and characterize long-term trends in groundwater quality at Y-12; and (5) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2011 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge along the boundary of the Oak Ridge Reservation. Modifications to the CY 2011 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2011 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information. The narrative sections of the report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. Groundwater Monitoring Schedules (when issued throughout CY 2011) will be inserted in Appendix C, and addenda to this plan (if issued) will be inserted in Appendix D. Laboratory requirements (bottle lists, holding times, etc.) are provided in Appendix E, and an approved Waste Management Plan is provided in Appendix F.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Energy Recovery Linac: Machine Protection System

The Machine Protection System (MPS) is a device‐safety system that is designed to prevent damage to hardware by generating interlocks, based upon the state of input signals generated by selected sub‐system. It exists to protect key machinery such as the 50 kW and 1 MW RF Systems. When a fault state occurs, the MPS is capable of responding with an interlock signal within several microseconds. The Machine Protection System inputs are designed to be fail‐safe. In addition, all fault conditions are latched and time‐stamped.

43 PARTICLE ACCELERATORS↗

Y-12 Groundwater Protection Program Groundwater And Surface Water Sampling And Analysis Plan For Calendar Year 2014

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2014 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring is performed by the GWPP during CY 2014 to achieve the following goals: 􀁸 to protect the worker, the public, and the environment; 􀁸 to maintain surveillance of existing and potential groundwater contamination sources; 􀁸 to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; 􀁸 to identify and characterize long-term trends in groundwater quality at Y-12; and 􀁸 to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring will be performed in three hydrogeologic regimes at Y-12.

54 ENVIRONMENTAL SCIENCES↗

A Theoretical Analysis: Physical Unclonable Functions and The Software Protection Problem

Physical Unclonable Functions (PUFs) or Physical One Way Functions (P-OWFs) are physical systems whose responses to input stimuli (i.e., challenges) are easy to measure (within reasonable error bounds) but hard to clone. This property of unclonability is due to the accepted hardness of replicating the multitude of uncontrollable manufacturing characteristics and makes PUFs useful in solving problems such as device authentication, software protection, licensing, and certified execution. In this paper, we focus on the effectiveness of PUFs for software protection and show that traditional non-computational (black-box) PUFs cannot solve the problem against real world adversaries in offline settings. Our contributions are the following: We provide two real world adversary models (weak and strong variants) and present definitions for security against the adversaries. We continue by proposing schemes secure against the weak adversary and show that no scheme is secure against a strong adversary without the use of trusted hardware. Finally, we present a protection scheme secure against strong adversaries based on trusted hardware.

97 MATHEMATICS AND COMPUTING↗

Mechanisms Underpinning Degradation of Protective Oxides and Thermal Barrier Coatings in High Hydrogen Content (HHC) - Fueled Turbines

The overarching goal of this research program has been to evaluate the potential impacts of coal-derived syngas and high-hydrogen content fuels on the degradation of turbine hot-section components through attack of protective oxides and thermal barrier coatings. The primary focus of this research program has been to explore mechanisms underpinning the observed degradation processes, and connections to the combustion environments and characteristic non-combustible constituents. Based on the mechanistic understanding of how these emerging fuel streams affect materials degradation, the ultimate goal of the program is to advance the goals of the Advanced Turbine Program by developing materials design protocols leading to turbine hot-section components with improved resistance to service lifetime degradation under advanced fuels exposures. This research program has been focused on studying how: (1) differing combustion environments – relative to traditional natural gas fired systems – affect both the growth rate of thermally grown oxide (TGO) layers and the stability of these oxides and of protective thermal barrier coatings (TBCs); and (2) how low levels of fuel impurities and characteristic non-combustibles interact with surface oxides, for instance through the development of molten deposits that lead to hot corrosion of protective TBC coatings. The overall program has been comprised of six inter-related themes, each comprising a research thrust over the program period, including: (i) evaluating the role of syngas and high hydrogen content (HHC) combustion environments in modifying component surface temperatures, heat transfer to the TBC coatings, and thermal gradients within these coatings; (ii) understanding the instability of TBC coatings in the syngas and high hydrogen environment with regards to decomposition, phase changes and sintering; (iii) characterizing ash deposition, molten phase development and infiltration, and associated corrosive/thermo-chemical attack mechanisms; (iv) developing a mechanics-based analysis of the driving forces for crack growth and delamination, based on molten phase infiltration, misfit upon cooling, and loss of compliance; (v) understanding changes in TGO growth mechanisms associated with these emerging combustion product streams; and (vi) identifying degradation resistant alternative materials (including new compositions or bi-layer concepts) for use in mitigating the observed degradation modes. To address the materials stability concerns, this program integrated research thrusts aimed at: (1) Conducting tests in simulated syngas and HHC environments to evaluate materials evolution and degradation mechanisms; assessing thermally grown oxide development unique to HHC environmental exposures; carrying out high-resolution imaging and microanalysis to elucidate the evolution of surface deposits (molten phase formation and infiltration); exploring thermo-chemical instabilities; assessing thermo-mechanical drivers and thermal gradient effects on degradation; and quantitatively measuring stress evolution due to enhanced sintering and thermo-chemical instabilities induced in the coating. (2) Executing experiments to study the melting and infiltration of simulated ash deposits, and identifying reaction products and evolving phases associated with molten phase corrosion mechanisms; utilizing thermal spray techniques to fabricate test coupons with controlled microstructures to study mechanisms of instability and degradation; facilitating thermal gradient testing; and developing new materials systems for laboratory testing; (3) Correlating information on the resulting combustion environments to properly assess materials exposure conditions and guide the development of lab-scale simulations of material exposures; specification of representative syngas and high-hydrogen fuels with realistic levels of impurities and contaminants, to explore differences in heat transfer, surface degradation, and deposit formation; and facilitating combustion rig testing of materials test coupons.

Mumm, Daniel↗

Fall Protection Introduction, #33462

The proper use of fall prevention and fall protection controls can reduce the risk of deaths and injuries caused by falls. This course, Fall Protection Introduction (#33462), is designed as an introduction to various types of recognized fall prevention and fall protection systems at Los Alamos National Laboratory (LANL), including guardrail systems, safety net systems, fall restraint systems, and fall arrest systems. Special emphasis is given to the components, inspection, care, and storage of personal fall arrest systems (PFASs). This course also presents controls for falling object hazards and emergency planning considerations for persons who have fallen.

99 GENERAL AND MISCELLANEOUS↗

Development of an Active, Man-Portable, Cooling System with Dehumidification Capabilities for Personal Protective Clothing/Equipment

Mainstream Engineering Corporation completed a highly successful SBIR program, during which we developed and commercialized products for microclimate cooling systems (MCS) and the heating, ventilation, air-conditioning, and refrigeration (HVAC/R) industry. We are marketing the MCS family of products for use with personal protective clothing/equipment (PPC/PPE) for firefighters, workers in clean rooms, HAZMAT response and other contamination/remediation teams, and military personnel that are required to wear Mission-Oriented Protective Posture (MOPP) suits and bomb disposal suits. Workers in these industries risk heat stress when confined within protective garments while in hot and humid environments. Our family of MCS and HVAC/R products that resulted from this SBIR program includes: 1. Active, Man-Portable, MCS for PPC/E—Our active system provides 350 W cooling of personal cooling for workers in thermally stressed environments. Although industrially hardened, this system is compact (0.69 ft 3 ) and lightweight (22.9 lbs). The MSC is easily decontaminated or disposed of between uses. 2. Miniature Screw Compressor for MCS—Our 350 Wcooling miniature screw compressor was originally designed for MCS and personal cooling systems. Occupying only 11 in 3 and weighing 1.4 lbs, the size and weight are less than any commercially available compressor with a similar cooling capacity. This miniature screw compressor is marketable as a low-pressure compressor or refrigerant pump. 3. Miniature Sliding Vane Compressor and Drive for MCS—Our 350 Wcooling compressor subassembly consists of a commercial miniature sliding vane compressor packaged with our motor controller. At 29.4 in3 and 1.5 lbs, this compressor is larger and heavier than the miniature screw but is lower cost and capable of producing higher head pressure. 4. Small Screw Compressor for HVAC/R—Our 50 kW cooling small screw compressor is for commercial HVAC/R applications. This compressor is extremely power dense at 0.34 ft 3 and 43 lbs and has a specific cooling capacity (kW/lb) five times greater than existing commercial compressors. We demonstrated high reliability (>5,100 hrs of operation and >3,400 on/off cycles), and we are currently discussing commercialization opportunities with laser manufacturers for cooling of their high-power devices. This final report summarizes the design, fabrication, testing, features, and benefits of each product. The commercialization potential and recommendations for the future are included.

42 ENGINEERING↗

CRADA 376 Final Report Development of Protective Coatings for 1 kW Hot Zone

Pacific Northwest National Laboratory (PNNL) has extensive experience in the development, fabrication, and evaluation of surface treatments and protective coatings for metallic solid oxide fuel cell (SOFC) components. For example, modified (Mn,Co)3O4 spinel coatings and coating/metal interfaces have been shown to substantially improve oxidation resistance, electrical performance, and oxide scale adhesion of ferritic stainless steel interconnects in planar SOFC stacks. At the time of the establishment of this CRADA, Protonex Technology Corporation had been working in the field of SOFC development for over 12 years and had demonstrated more than 250 thermal cycles with a less than 15 minutes start time and more than 2000 hours of continuous operation on a 250W tubular solid oxide hot zone module as part of a program for the Office of the Secretary of Defense (OSD). An industrial version of the military system, denoted P200i, had been developed that was launched at the 2015 Fuel Cell Expo in Tokyo. Feedback during beta testing of this unit was very positive. However, Protonex recognized that to transition from military markets, the commercial system would require longer life time and higher power. Leveraging their novel thermal management strategy from the tubular hot zone that allowed for rapid and repeated thermal cycling, Protonex developed a planar 1kW module aimed at the industrial and commercial market. However, more robust interconnect coatings were needed to bring the system into the 1000+ hour life time requested by customers. Therefore, PNNL’s experience and technology were engaged to enable the 1kw system to transition from military applications to commercial and industrial applications. In this CRADA, PNNL teamed with Protonex to leverage PNNL’s expertise in protective coating techniques for solid oxide fuel cell (SOFC) applications. As the first step in the collaboration, protective spinel coatings were fabricated at PNNL onto ten AISI 440 stainless steel bus bars provided by Protonex. A precursor slurry containing spinel powder was applied to the steel surfaces via an ultrasonic spray process. The coated bars were then subjected to a reducing atmosphere heat treatment (i.e., heated to 850°C at 3°C/min in a hydrogen atmosphere and held at that temperature for five hours). Five of the bars were left in this reduced condition; the other five bars were subjected to an oxidizing heat treatment (i.e., heated to 1000°C at 3°C/min in air and held at that temperature for one hour). The bars were then sent to Protonex for testing. Subsequently, Protonex decided to discontinue their SOFC development activities, so they had no further interest in continuing the collaboration with PNNL, and the CRADA activities were terminated.

30 DIRECT ENERGY CONVERSION↗

National-Tribal Critical Infrastructure Protection: Collaboration for Extraordinary National Security Benefit

This paper examines national and tribal collaborative opportunities to get ahead of the critical infrastructure insecurity problem. Recommendations are viewed through the lens of the Sandia Labs Tribal Cyber-Energy initiative and national security projects. Recommendations include 1) Collaboratively address national priority and shared challenges to gain faster and better solutions to national priority problems on a smaller yet comprehensive American Indian and Alaskan Native sovereign single-point of authority scale 2) Utilize newer standards-based technologies to provide scalable, capable, and manageable solutions for greatly expanded and connected national critical infrastructures 3) Employ Cyber-Physical-Resilient design preliminary analysis to define concept- to-disposition design requirements for preemptive critical infrastructure risk mitigation and baked-in security; 4) Develop data-centric protection to provide increased information asset protection as data shifts from data-owner operated on-premises infrastructure to virtual service provider data-steward owned and operated off-premises infrastructure; and 5) Balance shared solutions with the National Institute of Science and Technology (NIST) Cybersecurity and Risk Management frameworks, and the System Security Engineering Guidelines. As yet unallocated federal funding would support research, development, the timely application of National-Tribal critical infrastructure protection, and critical infrastructure Cyber disruption response and recovery with extraordinary mutual benefits for the foreseeable future. The Critical Infrastructure Insecurity Problem: Rapid modernization and expansive connectivity are due to advances in Information and Communications Technologies that have sweeping cyber impact across all critical infrastructure sectors. Supervisory Control and Data Acquisition and Industrial Control Systems are particularly impacted as systems long separated from the Internet are now being connected and computerized. Virtualization and mobility create a Data Everywhere-User Anywhere paradigm that has evaporated the enterprise network perimeter. There are multi-front technological challenges at play, where long depended on technologies simply don't scale to current needs resulting in a digital dichotomy of competing old and new standards. New standards-based technologies scale but are not as well-known or as widely deployed, which leaves decision makers, stakeholders, and the workforce in a quandary, caught mid-stream between the technological past and the virtual future. Rapid and expansive cyber threat accompanies disruptive change in connectivity and computational dependencies. A lack of action will exacerbate the problem if new technologies roll out without baked-in security design. The Risk: If National-Tribal CIP collaboration to design in security is not done, then an ongoing state of insufficient bolt-on security and elevated threat exposure will remain for years to come.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Physical Protection Recommendations for Small Modular Reactor Facilities

This recommendation document will provide international partners insight on physical protection systems (PPSs) for small modular reactors (SMRs). SMRs create many unique challenges for physical protection that must be addressed in design and implementation. This document will attempt to highlight possible challenges of SMRs and identify potential physical protection recommendations to mitigate these challenges. These recommendations are based on hypothetical SMR facilities and PPSs and their effectiveness against hypothetical adversaries.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reducing the Overnight Capital Cost of Advanced Reactors Using Equipment-Level Seismic Protective Systems

Consideration of the effects of earthquake shaking on the design and construction of nuclear power plants adds substantially to the overnight capital cost, with anecdotal estimates as high as 35+%, attributed to additional construction materials, need for one-off and sub-optimal designs of equipment due to conflicting design choices, the high cost of seismic qualification of equipment, and regulatory review. Safety-critical equipment in large light water reactors is designed and qualified for seismic demands imposed by the supporting reactor building, optimal mechanical designs are not possible, and designs of a given piece of equipment may vary with height above grade. Similar negative impacts are expected for advanced reactors unless the seismic design paradigm is changed. The overarching goal of this transformational MEITNER project, which involved a multidisciplinary engineering team and designers of three fundamentally different advanced reactors, was to adapt proven seismic isolation and damping technologies to operationalize modular protective systems for safety-class equipment inside advanced reactor buildings. Such seismic protective systems would be tightly integrated into design development for reactor support systems and balance-of-plant construction. The adoption of the technology, which is widely used in non-nuclear sectors, would simplify plant design, enable the use of standardized equipment and buildings, optimized for operational performance, and reduce plant size and weight. The need for site-specific equipment would be eliminated, enabling identical equipment to be used across multiple plants sited across the US and economies of scale, and catalyzing new interest and investment. The equipment-based protective systems would allow siting of advanced reactors in regions of high seismic hazard.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗