Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Methods to Account for CAP-88 PC-Omitted Nuclides in Radioactive Air Emissions From DOE Facilities

Routine research and development activities at US Department of Energy facilities can result in the release of radioactive emissions, potentially exposing the public and the environment. Such emissions are subject to certain Clean Air Act regulations, specifically those outlined in 40 CFR Part 61, Subpart H, which are enforced by the US Environmental Protection Agency. Compliance is determined in part with a dose standard. Doses to members of the public from most US Department of Energy facility airborne emissions are modeled using CAP-88 PC software, the latest version of which contains more than 1,200 radionuclides. Radioactive effluents from US Department of Energy facilities may contain radioisotopes that are not available in CAP-88 PC, and those radioisotopes must still be evaluated to determine whether doses to members of the public are below established limits. CAP-88 PC-omitted radionuclides can be accounted for using alternate methods, including the use of surrogate radionuclides. Here, this paper elucidates the process of accounting for CAP-88 PC-omitted radionuclides by providing criteria and rationale for surrogate selection, a compilation of surrogate radionuclides used in the past by US Department of Energy facilities, a discussion of alternate methods used to account for CAP-88 PC-omitted radionuclides and a comparison of methods and impacts on receptor doses. Ultimately, this paper aims to aid in the process of surrogate selection and consequently to simplify and expedite compliance with Clean Air Act regulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Superradiant Neutrino Lasers from Radioactive Condensates

Superradiance emerges from collective spontaneous emission in optically pumped gases, and is characterized by photon emission enhancements of up to $\frac{1}{4}$⁢𝑁 2 in an 𝑁 atom system. The gain mechanism derives from correlations developed within the decay medium rather than from stimulated emission as in lasing, so an analog of this process should be possible for fermionic final states. We introduce here the concept of superradiant neutrino emission from a radioactive Bose Einstein condensate, which can form the basis for a superradiant neutrino laser. A plausible experimental realization based on a condensate of electron-capture isotope 83 Rb could exhibit effective radioactive decay rates accelerated from 86.2 days to minutes in viably sized rubidium condensates of 10 6 atoms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trapping radioactive {sup 82}Rb in an optical dipole trap and evidence of spontaneous spin polarization

Optical trapping of selected species of radioactive atoms has great potential in precision measurements for testing fundamental physics such as the electric dipole moment, atomic parity nonconservation, and parity-violating {beta}-decay correlation coefficients. We report on the trapping of 10{sup 4} radioactive {sup 82}Rb atoms (t{sub 1/2}=75 s) with a trap lifetime of {approx}55 s in an optical dipole trap. Transfer efficiency from the magneto-optical trap is {approx}14%. We further report evidence of spontaneous spin polarization of the atoms in optical dipole trap loading. These advancements are an important step toward a new generation of precision nuclear-spin-{beta}-emission direction correlation measurements with polarized {sup 82}Rb atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cluster radioactive decay within the preformed cluster model using relativistic mean-field theory densities

We have studied the (ground-state) cluster radioactive decays within the preformed cluster model (PCM) of Gupta and collaborators [R. K. Gupta, in Proceedings of the 5th International Conference on Nuclear Reaction Mechanisms, Varenna, edited by E. Gadioli (Ricerca Scientifica ed Educazione Permanente, Milano, 1988), p. 416; S. S. Malik and R. K. Gupta, Phys. Rev. C 39, 1992 (1989)]. The relativistic mean-field (RMF) theory is used to obtain the nuclear matter densities for the double folding procedure used to construct the cluster-daughter potential with M3Y nucleon-nucleon interaction including exchange effects. Following the PCM approach, we have deduced empirically the preformation probability P{sub 0}{sup emp} from the experimental data on both the alpha- and exotic cluster-decays, specifically of parents in the trans-lead region having doubly magic {sup 208}Pb or its neighboring nuclei as daughters. Interestingly, the RMF-densities-based nuclear potential supports the concept of preformation for both the alpha and heavier clusters in radioactive nuclei. P{sub 0}{sup a}lpha{sup (emp)} for alpha decays is almost constant (approx10{sup -2}-10{sup -3}) for all the parent nuclei considered here, and P{sub 0}{sup c(emp)} for cluster decays of the same parents decrease with the size of clusters emitted from different parents. The results obtained for P{sub 0}{sup c(emp)} are reasonable and are within two to three orders of magnitude of the well-accepted phenomenological model of Blendowske-Walliser for light clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cluster radioactivity of Og 176 118 294

According to theory, cluster radioactivity becomes an important decay mode in superheavy nuclei. We suggest that the strongly asymmetric fission, or cluster emission, is in fact the dominant fission channel for Og 176 118 294 , which is currently the heaviest synthetic isotope known. Our theoretical approach incorporates critical features of fission dynamics, including quantum tunneling and stochastic dynamics up to scission. We show that despite appreciable differences in static fission properties such as fission barriers and spontaneous fission lifetimes, the prediction of cluster radioactivity in Og 176 118 294 is robust with respect to the details of calculations, including the choice of energy density functional, collective inertia, and strength of the dissipation term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning and field tests of a van-mounted system for the detection of radioactive sources and Special Nuclear Material

MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioimmunotherapy with radioactive nanoparticles: First results of dosimetry for vascularized and necrosed solid tumors

Radioimmunotherapy uses monoclonal antibodies that are still labeled with only one radioactive atom. The aim of this paper is to assess, by means of MCNPX simulations, the doses delivered around and throughout a solid tumor when the radioactive atom linked to each antibody is replaced by a 5 nm diameter nanoparticle composed of numerous radionuclides. A new model for a spherical vascularized tumor has been developed in which the antibody distributions inside the tumor can be uniform or heterogeneous. It is also possible to simulate a central necrotic core inside the tumor where the concentration of radiolabeled antibodies is assumed to be zero. Dosimetry calculations have been performed for the beta-emitting radionuclide {sup 90}Y{sub 2}O{sub 3}. Preliminary results show that the irregularity of vasculature and the presence of a necrotic core have a noticeable influence on the deposited dose profiles. Moreover, with a total activity of 5 and 34 MBq for tumor radii of 0.5 and 1.0 cm, respectively, viable tumor cells can receive doses of up to 50 Gy, even if high nonuniformity of the total activity is observed in the tumor. These simulations still require accurate information about antibody characteristics and necrosis sizes but clearly confirm that the use of monoclonal antibodies conjugated to nanoparticles could lead to a considerable enhancement of treatment efficacy against cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of dose to patient, spouse/caretaker, and staff, from an implanted trackable radioactive fiducial for use in the radiation treatment of prostate cancer

Purpose: A fiducial tracking system based on a novel radioactive tracking technology is being developed for real-time target tracking in radiation therapy. In this study, the authors calculate the radiation dose to the patient, the spouse/caretaker, and the medical staff that would result from a 100 {mu}Ci Ir192 radioactive fiducial marker permanently implanted in the prostate of a radiation therapy patient. Methods: Local tissue dose was calculated by Monte Carlo simulation. The patient's whole body effective dose equivalent was calculated by summing the doses to the sensitive organs. Exposure of the spouse/caretaker was calculated from the NRC guidelines. Exposure of the medical staff was based on estimates of proximity to and time spent with the patient. Results: The local dose is below 40 Gy at 5 mm from the marker and below 10 Gy at 10 mm from the marker. The whole body effective dose equivalent to the patient is 64 mSv. The dose to the spouse/caretaker is 0.25 mSv. The annual exposures of the medical staff are 0.2 mSv for a doctor performing implantations and 0.34 mSv for a radiation therapist positioning patients for therapy. Conclusions: The local dose is not expected to have any clinically significant effect on the surrounding tissue which is irradiated during therapy. The dose to the patient is small in comparison to the whole body dose received from the therapy itself. The exposure of all other people is well below the recommended limits. The authors conclude that there is no radiation exposure related contraindication for use of this technology in the radiation treatment of prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-388: Estimating the Radioactivity Inventory of a Cyclotron Based Pencil Beam Proton Therapy Facility

Purpose: Parts of the cyclotron and energy degrader are incidentally activated by protons lost during the acceleration and transport of protons for radiation therapy. An understanding of the radioactive material inventory is needed when regulatory requirements are assessed. Methods: First, the tumor dose and volume is used to determine the required energy deposition. For spot scanning, the tumor length along the beam path determines the number of required energy layers. For each energy layer the energy deposition per proton can be calculated from the residual proton range within the tumor. Assuming a typical layer weighting, an effective energy deposition per proton can then be calculated. The total number of required protons and the number of protons per energy layer can then be calculated. For each energy layer, proton losses in the energy degrader are calculated separately since its transmission efficiency, and hence the amount of protons lost, is energy dependent. The degrader efficiency also determines the number of protons requested from the cyclotron. The cyclotron extraction efficiency allows a calculation of the proton losses within the cyclotron. The saturation activity induced in the cyclotron and the degrader is equal to the production rate R for isotopes whose half-life is shorter that the projected cyclotron life time. R can be calculated from the proton loss rate and published production cross sections. Results: About 1/3 of the saturation activity is produced in the cyclotron and 2/3 in the energy degrader. For a projected case mix and a patient load of 1100 fractions per week at 1.8 Gy per fraction a combined activity of 180 mCi was estimated at saturation. Conclusion: Calculations were used to support to application of a radioactive materials license for the possession of 200 mCi of activity for isotopes with atomic numbers ranging from 1-83.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-09: Radioactive Seed Localization for Breast Lumpectomy - Towards Optimization

Purpose: The aim of this work is to propose a method to optimize radioactive source localization (RSL) for non-palpable breast cancer surgery. RSL is commonly used as a guiding technique during surgery for excision of non-palpable tumors. A collimated hand-held detector is used to localize radioactive sources implanted in tumors. Incisions made by the surgeon are based on maximum observed detector counts, and tumors are subsequently resected based on an arbitrary estimate of the counts expected at the surgical margin boundary. This work focuses on building a framework to predict detector counts expected throughout the procedure to improve surgical margins. Methods: A gamma detection system called the Neoprobe GDS was used for this work. The probe consists of a cesium zinc telluride crystal and a collimator. For this work, an I-125 Best Medical model 2301 source was used. The source was placed in three different phantoms, a PMMA, a Breast (25%- glandular tissue/75%- adipose tissue) and a Breast (75-25) phantom with a backscatter thickness of 6 cm. Counts detected by the probe were recorded with varying amounts of phantom thicknesses placed on top of the source. A calibration curve was generated using MATLAB based on the counts recorded for the calibration dataset acquired with the PMMA phantom. Results: The observed detector counts data used as the validation set was accurately predicted to within ±3.2%, ±6.9%, ±8.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. The average difference between predicted and observed counts was −0.4%, 2.4%, 1.4% with a standard deviation of 1.2 %, 1.8%, 3.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. Conclusion: The results of this work provide a basis for characterization of a detector used for RSL. Counts were predicted to within ±9% for three different phantoms without the application of a density correction factor.

60 APPLIED LIFE SCIENCES↗

Experimental investigations of changes in the rate of beta decay of radioactive elements

Changes in the rate of the beta decay of radioactive elements whose periods are about 24 h and 27 d are detected on the basis of long-term investigations performed with the aid of scintillation and germanium-lithium gamma detectors. The use of the scintillation procedure yields results whose level of significance is much higher than 5%, while the procedure based on germanium-lithium detectors gives a more than 1% deviation from the average value of fluxes of gamma rays accompanying, for example, {sup 60}Co beta decay. With allowance for the rotation of the laboratory frame together with the Earth, deviations of the change in the rate of beta decay of radioactive elements single out three directions in the physical space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics with beams of radioactive nuclei

A survey of the latest results from experiments devoted to studying the structure of nuclei and nuclear-reaction mechanisms by means of accelerated radioactive beams is given. Results obtained in Dubna with the aid of the DRIBs accelerator complex and at other radioactive-beam factories are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cold reaction valleys in the radioactive decay of superheavy {sup 286}112, {sup 292}114, and {sup 296}116 nuclei

Cold reaction valleys in the radioactive decay of superheavy nuclei {sup 286}112, {sup 292}114, and {sup 296}116 are studied taking Coulomb and Proximity Potential as the interacting barrier. It is found that in addition to alpha particle, {sup 8}Be, {sup 14}C, {sup 28}Mg, {sup 34}Si, {sup 50}Ca, etc. are optimal cases of cluster radioactivity since they lie in the cold valleys. Two other regions of deep minima centered on {sup 208}Pb and {sup 132}Sn are also found. Within our Coulomb and Proximity Potential Model half-life times and other characteristics such as barrier penetrability, decay constant for clusters ranging from alpha particle to {sup 68}Ni are calculated. The computed alpha half-lives match with the values calculated using Viola-Seaborg-Sobiczewski systematics. The clusters {sup 8}Be and {sup 14}C are found to be most probable for emission with T{sub 1/2} < 10{sup 30} s. The alpha-decay chains of the three superheavy nuclei are also studied. The computed alpha-decay half-lives are compared with the values predicted by Generalized Liquid Drop Model and they are found to match reasonably well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The HELIOS spectrometer and the radioactive beam program at Argonne.

The near-term radioactive beam capabilities of ATLAS include radioactive beams produced in flight in a gas cell, or starting in the fall of 2009, re-accelerated beams of 252Cf fission fragments provided by the new CARIBU injector. The availability of such exotic beams will allow for detailed studies of the single-particle aspects of nuclear structure in neutron-rich nuclei reaching out to the astrophysical r-process path by employing light-ion reactions in inverse kinematics. The HELIOS spectrometer is based on a new concept that is especially well suited for such studies. This concept was recently demonstrated using the reactions D(28Si,p)29Si with a (stable) 168 MeV 28Si beam. Since then D(12B,p)13B, D(17O,p)18O, and D(15C,p)16C have been studied successfully. The combination of neutron-rich beams from CARIBU and the HELIOS spectrometer opens a fertile research area of precision studies of the single particle strengths and collective excitations in exotic nuclei, and is likely to have applications in other reactions as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of Low-level Point Radioactive Sources using a sensor network

Identification of a low-level point radioactive source amidst background radiation is achieved by a network of radiation sensors using a two-step approach. Based on measurements from three or more sensors, a geometric difference triangulation method or an N-sensor localization method is used to estimate the location and strength of the source. Then a sequential probability ratio test based on current measurements and estimated parameters is employed to finally decide: (1) the presence of a source with the estimated parameters, or (2) the absence of the source, or (3) the insufficiency of measurements to make a decision. This method achieves specified levels of false alarm and missed detection probabilities, while ensuring a close-to-minimal number of measurements for reaching a decision. This method minimizes the ghost-source problem of current estimation methods, and achieves a lower false alarm rate compared with current detection methods. This method is tested and demonstrated using: (1) simulations, and (2) a test-bed that utilizes the scaling properties of point radioactive sources to emulate high intensity ones that cannot be easily and safely handled in laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗