Search NASA⌕ Search

SEARCH · Search NASA

Results for “RANDOM PHASE APPROXIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

816 records · Page 46

Small Angle Neutron Scattering Study of Complex Coacervate Micelles and Hydrogels Formed from Ionic Diblock and Triblock Copolymers

A complex coacervate is a fluid phase that results from the electrostatic interactions between two oppositely charged macromolecules. The nature of the coacervate core structure of hydrogels and micelles formed from complexation between pairs of diblock or triblock copolymers containing oppositely charged end-blocks as a function of polymer and salt concentration was investigated. Both ABA triblock copolymers of poly[(allyl glycidyl ether)-b-(ethylene oxide)-b-(allyl glycidyl ether)] and analogous poly[(allyl glycidyl ether)-b-(ethylene oxide)] diblock copolymers, which were synthesized to be nearly one-half of the symmetrical triblock copolymers, were studied. The poly(allyl glycidyl ether) blocks were functionalized with either guanidinium or sulfonate groups via postpolymerization modification. Mixing of oppositely charged block copolymers resulted in the formation of nanometer-scale coacervate domains. Small angle neutron scattering (SANS) experiments were used to investigate the size and spacing of the coacervate domains. The SANS patterns were fit using a previously vetted, detailed model consisting of polydisperse core–shell micelles with a randomly distributed sphere or body-centered cubic (BCC) structure factor. For increasing polymer concentration, the size of the coacervate domains remained constant while the spatial extent of the poly(ethylene oxide) (PEO) corona decreased. However, increasing salt concentration resulted in a decrease in both the coacervate domain size and the corona size due to a combination of the electrostatic interactions being screened and the shrinkage of the neutral PEO blocks. Additionally, for the triblock copolymers that formed BCC ordered domains, the water content in the coacervate domains was calculated to increase from approximately 16.8% to 27.5% as the polymer concentration decreased from 20 to 15 wt %.

36 MATERIALS SCIENCE↗

A new class of accelerated kinetic Monte Carlo algorithms

Kinetic ( aka dynamic) Monte Carlo (KMC) is a powerful method for numerical simulations of time dependent evolution applied in a wide range of contexts including biology, chemistry, physics, nuclear sciences, financial engineering, etc. Generally, in a KMC the time evolution takes place one event at a time, where the sequence of events and the time intervals between them are selected (or sampled) using random numbers. While details of the method implementation vary depending on the model and context, there exist certain common issues that limit KMC applicability in almost all applications. Among such is the notorious 'flicker problem' where the same states of the systems are repeatedly visited but otherwise no essential evolution is observed. In its simplest form the flicker problem arises when two states are connected to each other by transitions whose rates far exceed the rates of all other transitions out of the same two states. In such cases, the model will endlessly hop between the two states otherwise producing no meaningful evolution. In most situation of practical interest, the trapping cluster includes more than two states making the flicker somewhat more difficult to detect and to deal with. Several methods have been proposed to overcome or mitigate the flicker problem, exactly or approximately. Of the exact methods, the one proposed by Novotny is perhaps most relevant to our research. Novotny formulates the problem of escaping from a trapping cluster as a Markov system with absorbing states. Given an initial state inside the cluster, it is in principle possible to solve the Master Equation for the time dependent probabilities to find the walker in a given state (transient or absorbing) of the cluster at any time in the future. Novotny then proceeds to demonstrate implementation of his general method to trapping clusters containing the initial state plus one or two transient states and all of their absorbing states. Similar methods have been subsequently proposed in [refs] but applied in a different context. The most serious deficiency of the earlier methods is that size of the trapping cluster size is fixed and often too small to bring substantial simulation speedup. Furthermore, the overhead associated with solving for the probability distribution on the trapping cluster sometimes makes such simulations less efficient than the standard KMC. Here we report on a general and exact accelerated kinetic Monte Carlo algorithm generally applicable to arbitrary Markov models1. Two different implementations are attempted both based on incremental expansion of trapping sub-set of Markov states: (1) numerical solution of the Master Equation with absorbing states and (2) incremental graph reduction followed by randomization. Of the two implementations, the 2nd one performs better allowing, for the first time, to overcome trapping basins spanning several million Markov states. The new method is used for simulations of anomalous diffusion on a 2D substrate and of the kinetics of diffusive 1st order phase transformations in binary alloys. Depending on temperature and (alloy) super-saturation conditions, speedups of 3 to 7 orders of magnitude are demonstrated, with no compromise of simulation accuracy.

97 MATHEMATICS AND COMPUTING↗

Experimental and computational studies on high-entropy carbide MoNbTaVWC 5 under high pressures

High-entropy carbide, MoNbTaVWC 5 , was synthesized from oxide precursors of the constituent metals, mixed with graphite powder in a microwave-generated hydrogen plasma at 26.66 kPa and 2100 °C. Ambient x-ray diffraction analysis confirms the full conversion of oxide precursors into a single-phase, face-centered cubic structure with a lattice parameter a = 4.3309 Å. Nanoindentation measured a hardness of 24.5 ± 1.3 GPa and an elastic modulus of 386 ± 22 GPa. The synthesized sample, mixed with a copper pressure marker, was studied by the radial x-ray diffraction technique with beryllium gasketing in a diamond anvil cell up to 70 GPa. The experimentally measured pressure–volume curve and shear strength were compared with theoretical predictions using the special quasi-random structure technique and density functional theory. MoNbTaVWC 5 achieved a 12% volume compression at 70 GPa and exhibited a high shear strength of 6.6 GPa. The present study demonstrates that the high-entropy carbide MoNbTaVWC 5 exhibits exceptional incompressibility and high strength under extreme conditions.

36 MATERIALS SCIENCE↗

2012 Gordon Research Conference on Rock Deformation - Formal Schedule and Speaker/Poster Program

The Gordon Research Conference on ROCK DEFORMATION was held at Proctor Academy Andover, New Hampshire, August 19-24, 2012. The Conference was well-attended with 124 participants (attendees list attached). The attendees represented the spectrum of endeavor in this field coming from academia, industry, and government laboratories, both U.S. and foreign scientists, senior researchers, young investigators, and students. Of the 124 attendees, 66 voluntarily responded to a general inquiry regarding ethnicity which appears on our registration forms. Of the 66 respondents, 8% were Minorities – 2% Hispanic, 6% Asian and 0% African American. Approximately 27% of the participants at the 2012 meeting were women. In designing the formal speakers program, emphasis was placed on current unpublished research and discussion of the future target areas in this field. There was a conscious effort to stimulate lively discussion about the key issues in the field today. Time for formal presentations was limited in the interest of group discussions. In order that more scientists could communicate their most recent results, poster presentation time was scheduled. Attached is a copy of the formal schedule and speaker program and the poster program. In addition to these formal interactions, "free time" was scheduled to allow informal discussions. Such discussions are fostering new collaborations and joint efforts in the field. Feedback processes are vitally important in controlling the rates and mechanisms of rock deformation. Positive feedbacks lead to accelerating rates, and commonly to spatial focusing. Localization and acceleration of creep is often associated with stress and/or strain rate dependent grain size reduction, frictional heating, or viscous shear heating. The presence of melt may help to localize and accelerate deformation, and in turn deformation may help to localize melt transport. Volume changes during retrograde metamorphic reactions may, under some circumstances, lead to fractures that maintain or increase permeability and reactive surface area, which in turn accelerates reaction rates. Hydraulic fracture often triggers a widening cascade of frictional failures on adjacent fracture systems. Feedbacks that form or reactivate closely-spaced fractures in the upper crust have relevance for, e.g., geological storage of CO 2 , enhanced geothermal power systems, and shale gas extraction. Clustering of earthquakes involves feedbacks in stress distribution on different faults, or segments of fault zones, that focus deformation in both time and space. Negative feedbacks can modulate or prevent accelerating strain. Gravitational instabilities, such as "delamination", "relamination", and diapirism, are affected by both positive and negative feedbacks when material undergoes phase transformations driven by changing pressure and temperature. Changes in pore pressure due to metamorphic reactions and/or shear heating can modulate earthquake behavior. There is increasing understanding of the mechanisms that limit earthquake rupture zones, and cause slow slip rather than seismic events. Crystallization in pore space can randomize previously focused fluid flow, reduce permeability, and bring metamorphic reactions to a halt. All of these feedbacks are related in a rich interplay of geodynamic processes.

58 GEOSCIENCES↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the density of states of disordered epitaxial graphene

The study is concerned with two types of disordered epitaxial graphene: (i) graphene with randomly located carbon vacancies and (ii) structurally amorphous graphene. The former type is considered in the coherent potential approximation, and for the latter type, a model of the density of states is proposed. The effects of two types of substrates, specifically, metal and semiconductor substrates are taken into account. The specific features of the density of states of epitaxial graphene at the Dirac point and the edges of the continuous spectrum are analyzed. It is shown that vacancies in epitaxial graphene formed on the metal substrate bring about logarithmic nulling of the density of states of graphene at the Dirac point and the edges of the continuous spectrum. If the Dirac point corresponds to the middle of the band gap of the semiconductor substrate, the linear trend of the density of states to zero in the vicinity of the Dirac point in defect-free graphene transforms into a logarithmic decrease in the presence of vacancies. In both cases, the graphene-substrate interaction is assumed to be weak (quasi-free graphene). In the study of amorphous epitaxial graphene, a simple model of free amorphous graphene is proposed as the initial model, in which account is taken of the nonzero density of states at the Dirac point, and then the interaction of the graphene sheet with the substrate is taken into consideration. It is shown that, near the Dirac point, the quadratic behavior of the density of states of free amorphous graphene transforms into a linear dependence for amorphous epitaxial graphene. In the study, the density of states of free graphene corresponds to the low-energy approximation of the electron spectrum.

36 MATERIALS SCIENCE↗