Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Expressions to determine temperatures and emission measures for solar X-ray events from GOES measurements

Expressions which give the effective color temperatures and corresponding emission measures for solar X-ray events observed with instruments onboard any of the GOES satellites are developed. Theoretical spectra were used to simulate the solar X-ray input at a variety of plasma temperatures. These spectra were folded through the wavelength dependent transfer functions for the two GOES detectors. The resulting detector responses and their ratio as a function of plasma temperature were then fit with simple analytic curves. Over the entire range between 5 and 30 million degrees, these fits reproduce the calculated color temperatures within 2 percent and the calculated emission measures within 5 percent. With the theoretical spectra, similar expressions for any pair of broadband X-ray detectors whose sensitivities are limited to wavelengths between 0.2 and 100 A are calculable.

Thomas, R. J.↗

Numerical integration of detector response functions via Monte Carlo simulations

Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Lithographic and DNA-Directed Assembly of a Configurable Plasmonic Metamaterial That Exhibits Electromagnetically Induced Transparency

Metamaterials are architectures that interact with light in novel ways by virtue of symmetry manipulation, and have opened a window into studying unprecedented light-matter interactions. However, they are commonly fabricated via lithographic methods, are usually static structures, and are limited in how they can react to external stimuli. Here we show that by combining lithographic techniques with DNA-based self-assembly methods, we can construct responsive plasmonic metamaterials that exhibit the plasmonic analog of an effect known as electromagnetically induced transparency (EIT), which can dramatically change their spectra upon motion of their constituent parts. Correlative scanning electron microscopy measurements, scattering dark-field microscopy, and computational simulations are performed on single assemblies to determine the relationship between their structures and spectral responses to a variety of external stimuli. The strength of the EIT-like effect in these assemblies can be tuned by precisely controlling the positioning of the plasmonic nanoparticles in these structures. For example, changing the ionic environment or dehydrating the sample will change the conformation of the DNA linkers and therefore the distance between the nanoparticles. Dark-field spectra of individual assemblies show peak shifts of up to many tens of nanometers upon DNA perturbations. This dynamic metamaterial represents a stepping stone toward state-of-the-art plasmonic sensing platforms and next-generation dynamic metamaterials.

36 MATERIALS SCIENCE↗

Defects Enable Dark Exciton Photoluminescence in Single-Walled Carbon Nanotubes

Variable temperature photoluminescence excitation spectroscopy of three (n,m) species of single-walled carbon nanotubes revealed that at resonant S 22 excitation, in addition to allowed excitonic optical transitions, several sidebands that should be forbidden based on selection rules were observed and appeared to have a strong temperature dependence. In particular, we found that a sideband located approximately 130 meV away from the bright S 11 exciton peak relating to the K-momentum dark exciton state, called X 1 , decreased in intensity five-fold as the samples were cooled. Direct optical excitation of this dark state is nominally forbidden, thus calling into question how the state is populated, and why it is so prominent in the photoluminescence spectrum. Interestingly, the ratio of the integrated photoluminescence intensities of X 1 to S 11 scales with a Boltzmann factor unrelated to the phonon that is thought to be responsible for depopulating the K-momentum dark exciton state: an in-plane transverse optical phonon, A 1 ’. Furthermore, photoluminescence spectra from individual (7,5) nanotubes show that only a small fraction exhibit the X 1 feature, with varying oscillator strength, thus suggesting that intrinsic processes such as phonon scattering are not responsible for populating the dark state. Alternatively, we suggest that populating the K-momentum dark exciton state requires scattering from defects, which is consistent with the increased magnitude of the X 1 feature for samples with increased sample purification and processing. Thus, the presence of an X 1 peak in photoluminescence is an extremely sensitive spectroscopic indicator of defects on single-walled carbon nanotubes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the thermal history of carbon fibers using Raman spectroscopy and a novel kinetic model

Carbon fibers and carbon fiber composites are applied in high-performance applications, but a key consideration for application is their relative sensitivity to oxidative environments. To enable in-situ characterization of carbon fibers exposed to oxidative conditions, the Raman spectral response of T700 carbon fibers that have been exposed to a variety of dwell temperatures is reported herein with dwell times reaching up to 1 month. Here, we evaluate the spectra holistically by using integrated absolute difference analysis. By combining this analysis with straightforward kinetic models, we connect the total Raman spectral response to the temperature-time curve that could yield such a shift in spectral parameters. Our work connects the Raman spectral response of carbon fibers to their thermal history and can easily be extended to other graphitic materials, such as nuclear graphite.

36 MATERIALS SCIENCE↗

Special features of the excitation spectra and kinetics of photoluminescence of the Si{sub 1-x}Ge{sub x}:Er/Si structures with relaxed heterolayers

Luminescent properties of heteroepitaxial Si{sub 1-x}Ge{sub x}:Er/Si structures with relaxed heterolayers are studied. The results of combined studies of the excitation spectra and kinetics of photoluminescence (PL) are used to single out the components providing the largest contribution to the PL signal of the Si{sub 1-x}Ge{sub x}:Er/Si structures in the wavelength region of 1.54 {mu}m. It is shown that relaxation of elastic stresses in the Si{sub 1-x}Ge{sub x}:Er heterolayer affects only slightly the kinetic characteristics of erbium luminescence and manifests itself in insignificant contribution of the defects and defect-impurity complexes to the luminescent response of the Si{sub 1-x}Ge{sub x}:Er/Si structures. In the excitation spectra of the erbium PL, special features related to the possibility of the rare-earth impurity excitation at energies lower than the band gap of the Si{sub 1} {sub -x}Ge{sub x} solid solution are revealed. It is shown that a peak the width of which depends on the band gap of the solid solution and the extent of its relaxation is observed in the excitation spectra of the erbium-related PL in the Si{sub 1-x}Ge{sub x}:Er/Si structures in the wavelength region of 1040-1050 nm. The observed specific features are accounted for by involvement of intermediate levels in the band gap of the Si{sub 1-x}Ge{sub x}:Er solid solution in the process of excitation of an Er{sup 3+} ion.

36 MATERIALS SCIENCE↗

Principles of two-dimensional terahertz spectroscopy of collective excitations: The case of Josephson plasmons in layered superconductors

Two-dimensional terahertz spectroscopy (2DTS), a terahertz analog of nuclear magnetic resonance, is a new technique poised to address many open questions in complex condensed matter systems. The conventional theoretical framework used ubiquitously for interpreting multidimensional spectra of discrete quantum level systems is, however, insufficient for the continua of collective excitations in strongly correlated materials. Here, in this work, we develop a theory for 2DTS of a model collective excitation, the Josephson plasma resonance in layered superconductors. Starting from a mean-field approach at temperatures well below the superconducting phase transition, we obtain expressions for the multidimensional nonlinear responses that are amenable to intuition derived from the conventional single-mode scenario. We then consider temperatures near the superconducting critical temperature T c , where dynamics beyond mean-field become important and conventional intuition fails. As fluctuations proliferate near T c , the dominant contribution to nonlinear response comes from an optical parametric drive of counterpropagating Josephson plasmons, which gives rise to 2D spectra that are qualitatively different from the mean-field predictions. As such, and in contrast to one-dimensional spectroscopy techniques, such as third harmonic generation, 2DTS can be used to directly probe thermally excited finite-momentum plasmons and their interactions. Our theory can readily be tested in cuprates, and we discuss implications beyond the present context of Josephson plasmons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗

Optical and electronic properties of mixed Ag-Au tetramer cations

We present experimental and theoretical studies of the optical response of mixed Ag {sub n} Au {sub 4−n}{sup +} (n=1–3) clusters in the photon energy range ℏω = 1.9–3.5 eV. Absorption spectra are recorded by a newly built longitudinal molecular beam depletion spectroscopy apparatus providing lower limits to absolute photodissociation cross sections. The experimental data are compared to optical response calculations in the framework of long-range corrected time-dependent density functional theory with initial cluster geometries obtained by the unbiased Birmingham Cluster Genetic Algorithm coupled with density functional theory. Experiments and excited state calculations shed light on the structural and electronic properties of the mixed Ag-Au tetramer cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MCNP Simulation of Discrete Gamma-ray Spectra for PGNAA Applications

Prompt Gamma Neutron Activation (PGNAA) systems use the neutron-induced gamma-ray spectra from test objects in order to identify their compositions. The U.S. Army in particular uses these systems to identify the contents of field-recovered munitions in order to determine the presence of chemical warfare materiel (CWM) or explosives. These field-recovered munitions can have a variety of different fills, including experimental fills, have a large range of sizes, and be assessed in different field conditions. All these variations can have a significant effect on the neutron-induced gamma-ray spectrum and therefore a large impact on automatic fill identification algorithms. In order to develop robust identification algorithms, parametric studies of the effects of munition size, fill composition, and assessment conditions are very useful but time-consuming and expensive in the laboratory. Monte Carlo modeling of the system response to these variations is a very attractive alternative, provided the modeling accurately reflects real gamma spectra and can be performed quickly and inexpensively when compared to experiment. At Idaho National Laboratory we have used the Monte Carlo N-Particle (MCNP6) code [2] to calculate the response of the Portable Isotopic Neutron Spectroscopy (PINS) system to a number of simulated chemical warfare munitions as well as performed laboratory measurements with the system. Two versions of PINS system were used; one excited the test object with neutrons from a 252C f source and one with neutrons from a portable deuterium-deuterium (DD) neutron generator. The sets of measurements and simulations with the two different neutron sources provided experimental data for development of automatic fill identification algorithms as well as providing a good test of the agreement between the MCNP calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A SURVEY OF FAR ULTRAVIOLET SPECTROSCOPIC EXPLORER OBSERVATIONS OF CATACLYSMIC VARIABLES

During its lifetime, the Far Ultraviolet Spectroscopic Explorer (FUSE) was used to observe 99 cataclysmic variables (CVs) in 211 separate observations. Here, we present a survey of the moderate-resolution (R {approx_equal} 10, 000), far-ultraviolet (905-1188 A), time-averaged FUSE spectra of CVs. The FUSE spectra are morphologically diverse. They show contributions from the accretion disk, the disk chromosphere, disk outflows, and the white dwarf (WD), but the relative contribution of each component varies widely as a function of CV subtype, orbital period and evolutionary state, inclination, mass accretion rate, and magnetic field strength of the WD. The data reveal information about the structure, temperature, density and mass flow rates of the disk and disk winds, the temperature of the WD and the effects of ongoing accretion on its structure, and the long-term response of the systems to disk outbursts. The complete atlas of time-averaged FUSE spectra of CVs is available at the Multimission Archive at Space Telescope Science Institute as a High Level Science Product.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Modeling for the Reentry of the Hayabusa Sample Return Capsule

Predicted shock-layer emission signatures of the Japanese Hayabusa capsule during its reentry are presented for comparison with flight measurements made during an airborne observation mission using NASA s DC-8 Airborne Laboratory. For each altitude, lines of sight were extracted from flow field solutions computed using an inhouse high-fidelity CFD code, DPLR, at 11 points along the flight trajectory of the capsule. These lines of sight were used as inputs for the line-by-line radiation code NEQAIR, and emission spectra of the air plasma were computed in the wavelength range from 300 nm to 1600 nm, a range which covers all of the different experiments onboard the DC-8. In addition, the computed flow field solutions were post-processed with the material thermal response code FIAT, and the resulting surface temperatures of the heat shield were used to generate thermal emission spectra based on Planck radiation. Both spectra were summed and integrated over the flow field. The resulting emission at each trajectory point was propagated to the DC-8 position and transformed into incident irradiance. Comparisons with experimental data are shown.

Winter, Michael W.↗

Radiation Modeling for the Reentry of the Hayabusa Sample Return Capsule

Predicted shock-layer emission signatures during the reentry of the Japanese Hayabusa capsule are presented and compared with flight measurements conducted during an airborne observation mission in NASA's DC-8 Airborne Laboratory. For selected altitudes at 11 points along the flight trajectory of the capsule, lines of sight were extracted from flow field solutions computed using the in-house high-fidelity CFD code, DPLR. These lines of sight were used as inputs for the line-by-line radiation code NEQAIR, and emission spectra of the air plasma were computed in the wavelength range from 300 nm to 1600 nm, a range which covers all of the different experiments onboard the DC-8. In addition, the computed flow field solutions were post-processed with the material thermal response code FIAT, and the resulting surface temperatures of the heat shield were used to generate thermal emission spectra based on Planck radiation. Both spectra were summed and integrated over the flow field. The resulting emission at each trajectory point was propagated to the DC-8 position and transformed into incident irradiance to be finally compared with experimental data.

shock-layer radiation↗

UNDERFLIGHT CALIBRATION OF SOHO/CDS AND HINODE/EIS WITH EUNIS-07

Flights of Goddard Space Flight Center's Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated radiometric calibrations for Solar and Heliospheric Observatory/Coronal Diagnostic Spectrometer (SOHO/CDS) and Hinode/Extreme Ultraviolet Imaging Spectrometer (Hinode/EIS). EUNIS carried two independent imaging spectrographs covering wavebands of 300-370 A in first order and 170-205 A in second order. After each flight, end-to-end radiometric calibrations of the rocket payload were carried out in the same facility used for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO/CDS, and Hinode/EIS observed the same solar locations, allowing the EUNIS calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1 line intensities calibrated with the standard (version 4) responsivities with the standard long-term corrections are found to be too low by a factor of 1.5 due to the decrease in responsivity. The EIS calibration update is performed in two ways. One uses the direct calibration transfer of the calibrated EUNIS-07 short wavelength (SW) channel. The other uses the insensitive line pairs, in which one member was observed by the EUNIS-07 long wavelength (LW) channel and the other by EIS in either the LW or SW waveband. Measurements from both methods are in good agreement, and confirm (within the measurement uncertainties) the EIS responsivity measured directly before the instrument's launch. The measurements also suggest that the EIS responsivity decreased by a factor of about 1.2 after the first year of operation (although the size of the measurement uncertainties is comparable to this decrease). The shape of the EIS SW response curve obtained by EUNIS-07 is consistent with the one measured in laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A intensity measured by EUNIS-07 is consistent with the radiance measured by CDS NIS in quiet regions near the disk center and the solar minimum irradiance recently obtained by CDS NIS and the Solar Dynamics Observatory/Extreme Ultraviolet Variability Experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and Computations of Second-Mode Instability Waves in Three Hypersonic Wind Tunnels

High-frequency pressure-fluctuation measurements were made in AEDC Tunnel 9 at Mach 10 and the NASA Langley 15-Inch Mach 6 and 31-Inch Mach 10 tunnels. Measurements were made on a 7deg-half-angle cone model. Pitot measurements of freestream pressure fluctuations were also made in Tunnel 9 and the Langley Mach-6 tunnel. For the first time, second-mode waves were measured in all of these tunnels, using 1-MHz-response pressure sensors. In Tunnel 9, second-mode waves could be seen in power spectra computed from records as short as 80 micro-s. The second-mode wave amplitudes were observed to saturate and then begin to decrease in the Langley tunnels, indicating wave breakdown. Breakdown was estimated to occur near N approx. equals 5 in the Langley Mach-10 tunnel. The unit-Reynolds-number variations in the data from Tunnel 9 were too large to see the same processes. In Tunnel 9, the measured transition locations were found to be at N = 4.5 using thermocouples, and N = 5.3 using 50-kHz-response pressure sensors. What appears to be a very long transitional region was observed at a unit Reynolds number of 13.5 million per meter in Tunnel 9. These results were consistent with the high-frequency pressure fluctuation measurements. High-frequency pressure fluctuation measurements indicated that transition did occur in the Langley Mach-6 tunnel, but the location of transition was not precisely determined. Unit Reynolds numbers in the Langley Mach-10 tunnel were too low to observe transition. More analysis of this data set is expected in the future.

Berridge, Dennis C.↗