Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

SU-D-BRE-03: Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy

Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the two treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary Statistics for Fun Dough Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a Play Dough{trademark}-like product, Fun Dough{trademark}, designated as PD. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2100 LMHU{sub D} at 100kVp to a low of about 1100 LMHU{sub D} at 300kVp. The standard deviation of each measurement is around 1% of the mean. The entropy covers the range from 3.9 to 4.6. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 8.5. LLNL prepared about 50mL of the Fun Dough{trademark} in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. Still, layers can plainly be seen in the reconstructed images, indicating that the bulk density of the material in the container is affected by voids and bubbles. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

Analysis of events with b-jets and a pair of leptons of the same charge in pp collisions at √s = 8 TeV with the ATLAS detector

An analysis is presented of events containing jets including at least one b -tagged jet, sizeable missing transverse momentum, and at least two leptons including a pair of the same electric charge, with the scalar sum of the jet and lepton transverse momenta being large. A data sample with an integrated luminosity of 20.3 fb –1 of pp collisions at √s = 8 TeV recorded by the ATLAS detector at the Large Hadron Collider is used. Standard Model processes rarely produce these final states, but there are several models of physics beyond the Standard Model that predict an enhanced rate of production of such events; the ones considered here are production of vector-like quarks, enhanced four-top-quark production, pair production of chiral b'-quarks, and production of two positively charged top quarks. Eleven signal regions are defined; subsets of these regions are combined when searching for each class of models. In the three signal regions primarily sensitive to positively charged top quark pair production, the data yield is consistent with the background expectation. There are more data events than expected from background in the set of eight signal regions defined for searching for vector-like quarks and chiral b'-quarks, but the significance of the discrepancy is less than two standard deviations. Furthermore, the discrepancy reaches 2.5 standard deviations in the set of five signal regions defined for searching for four-top-quark production. The results are used to set 95% CL limits on various models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modulation and Modeling of Three-Dimensional Nanowire Assemblies Targeting Gas Sensors with High Response and Reliability

Despite improved sensitivity, simple downsizing of gas-sensing components to randomly arranged nanostructures often faces challenges associated with unpredictable electrical conduction pathways. In the present study, controlled fabrication of three-dimensional (3D) metal oxide nanowire networks is demonstrated that can greatly improve both signal stability and sensor response compared to random nanowire arrays. For example, the highest ever reported H 2 S gas response value, and a 5 times lower relative standard deviation of baseline resistance than that of random nanowires assemblies, are achieved with the ordered 3D nanowire network. Systematic engineering of 3D geometries and their modeling, utilizing equivalent circuit components, provide additional insights into the electrical conduction and gas-sensing response of 3D assemblies, revealing the critical importance of wire-to-wire junction points and their arrangement. Here these findings suggest new design rules for both enhanced performance and reliability of chemical sensors, which may also be extended to other devices based on nanoscale building blocks.

36 MATERIALS SCIENCE↗

Predictive RANS simulations via Bayesian Model-Scenario Averaging

The turbulence closure model is the dominant source of error in most Reynolds-Averaged Navier–Stokes simulations, yet no reliable estimators for this error component currently exist. Here we develop a stochastic, a posteriori error estimate, calibrated to specific classes of flow. It is based on variability in model closure coefficients across multiple flow scenarios, for multiple closure models. The variability is estimated using Bayesian calibration against experimental data for each scenario, and Bayesian Model-Scenario Averaging (BMSA) is used to collate the resulting posteriors, to obtain a stochastic estimate of a Quantity of Interest (QoI) in an unmeasured (prediction) scenario. The scenario probabilities in BMSA are chosen using a sensor which automatically weights those scenarios in the calibration set which are similar to the prediction scenario. The methodology is applied to the class of turbulent boundary-layers subject to various pressure gradients. For all considered prediction scenarios the standard-deviation of the stochastic estimate is consistent with the measurement ground truth. Furthermore, the mean of the estimate is more consistently accurate than the individual model predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence for WW/WZ vector boson scattering in the decay channel ℓνqq produced in association with two jets in proton-proton collisions at s = 13 TeV

Evidence is reported for electroweak (EW) vector boson scattering in the decay channel $\ell\nu$qq of two weak vector bosons WV (V = W or Z), produced in association with two parton jets. The search uses a data set of proton-proton collisions at 13 TeV collected with the CMS detector during 2016-2018 with an integrated luminosity of 138 fb$^{-1}$. Events are selected requiring one lepton (electron or muon), moderate missing transverse momentum, two jets with a large pseudorapidity separation and a large dijet invariant mass, and a signature consistent with the hadronic decay of a W/Z boson. The cross section is computed in a fiducial phase space defined at parton level requiring all parton transverse momenta $p_\mathrm{T}$$\gt$ 10 GeV and at least one pair of outgoing partons with invariant mass $m_\mathrm{qq}$$\gt$ 100 GeV. The measured and expected EW WV production cross sections are 1.90 $^{+0.53}_{-0.46}$ pb and 2.23 $^{+0.08}_{-0.11}$ (scale) $\pm$ 0.05 (PDF) pb, respectively, where PDF is the parton distribution function. The observed EW signal strength is $m_\mathrm{EW}$ = 0.85 $\pm$ 0.12 (stat) $^{+0.19}_{-0.17}$ (syst), corresponding to a signal significance of 4.4 standard deviations with 5.1 expected, and it is measured keeping the quantum chromodynamics (QCD) associated diboson production fixed to the standard model prediction. This is the first evidence of vector boson scattering in the $\ell\nu$qq decay channel at LHC. The simultaneous measurement of the EW and QCD associated diboson production agrees with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the redshift evolution of the cosmic microwave background blackbody temperature with Planck data

We constrain the deviation of adiabatic evolution of the universe using the data on the cosmic microwave background (CMB) temperature anisotropies measured by the Planck satellite and a sample of 481 X-ray selected clusters with spectroscopically measured redshifts. To avoid antenna beam effects, we bring all of the maps to the same resolution. We use a CMB template to subtract the cosmological signal while preserving the Thermal Sunyaev–Zeldovich (TSZ) anisotropies; next, we remove galactic foreground emissions around each cluster and we mask out all known point sources. If the CMB blackbody temperature scales with redshift as T(z)=T{sub 0}(1+z){sup 1−α}, we constrain deviations of adiabatic evolution to be α = −0.007 ± 0.013, consistent with the temperature-redshift relation of the standard cosmological model. This result could suffer from a potential bias δα associated with the CMB template. We quantify it to be |δα|⩽0.02, with the same sign as the measured value of α. Our result is free from those biases associated with using TSZ selected clusters; it represents the best constraint to date of the temperature-redshift relation of the Big Bang model using only CMB data, confirming previous results.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological inflation with graceful exit

We investigate a class of models of topological inflation in which a super-Hubble-sized global monopole seeds inflation. These models are attractive since inflation starts from rather generic initial conditions, but their not so attractive feature is that, unless symmetry is again restored, inflation never ends. In this work we show that, in presence of another nonminimally coupled scalar field, that is both quadratically and quartically coupled to the Ricci scalar, inflation naturally ends, representing an elegant solution to the graceful exit problem of topological inflation. While the monopole core grows during inflation, the growth stops after inflation, such that the monopole eventually enters the Hubble radius, and shrinks to its Minkowski space size, rendering it immaterial for the subsequent Universe's dynamics. Furthermore, we find that our model can produce cosmological perturbations that source CMB temperature fluctuations and seed large scale structure statistically consistent (within one standard deviation) with all available data. In particular, for small and (in our convention) negative nonminimal couplings, the scalar spectral index can be as large as n {sub s} ≅ 0.955, which is about one standard deviation lower than the central value quoted by the most recent Planck Collaboration.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of the Jet Diffusion Wake Using Dijets in Heavy-Ion Collisions

Energetic quarks and gluons traversing a hot and dense quark-gluon plasma deposit energy and momentum into the medium before hadronizing to collimated sprays of particles, known as jets. This energy-momentum deposition is expected to produce medium responses, collectively known as jet wakes, with “diffusion wake” denoting a depletion of particles in the direction opposite to the propagating jet. The diffusion wake is studied by comparing dijet-hadron correlations measured in lead-lead (PbPb) and proton-proton (pp) collisions. The analysis uses PbPb and pp data recorded at a nucleon-nucleon (NN) center-of-mass energy s NN = 5.02 TeV with the CMS detector at the CERN LHC. By exploring how the dijet-hadron correlation distributions differ for various pseudorapidity separations of the two jets in the dijet, the presence of a jet diffusion wake is firmly established. The diffusion wake signal has a significance greater than 5 standard deviations for charged particles in the transverse momentum range 1 < p T < 2 GeV . The measurements are compared with model predictions with and without jet wake effects, providing new insights into quark-gluon plasma properties and the formation of jet-induced wakes.

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

Cosmological evolution of light dark photon dark matter

Light dark photons are subject to various plasma effects, such as Debye screening and resonant oscillations, which can lead to a more complex cosmological evolution than is experienced by conventional cold dark matter candidates. Maintaining a consistent history of dark photon dark matter requires ensuring that the superthermal abundance present in the early Universe (i) does not deviate significantly after the formation of the cosmic microwave background (CMB), and (ii) does not excessively leak into the Standard Model plasma after big band nucleosynthesis (BBN). We point out that the role of nonresonant absorption, which has previously been neglected in cosmological studies of this dark matter candidate, produces strong constraints on dark photon dark matter with mass as low as 10 - 22 eV . Furthermore, we show that resonant conversion of dark photons after recombination can produce excessive heating of the intergalactic medium (IGM) which is capable of prematurely reionizing hydrogen and helium, leaving a distinct imprint on both the Ly- α forest and the integrated optical depth of the CMB. Our constraints surpass existing cosmological bounds by more than 5 orders of magnitude across a wide range of dark photon masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

tan{beta}-enhanced supersymmetric corrections to the anomalous magnetic moment of the muon

We report on a two-loop supersymmetric contribution to the magnetic moment (g-2){sub {mu}} of the muon which is enhanced by two powers of tan{beta}. This contribution arises from a shift in the relation between the muon mass and Yukawa coupling and can increase the supersymmetric contribution to (g-2){sub {mu}} sizably. As a result, if the currently observed 3{sigma} deviation between the experimental and SM theory value of (g-2){sub {mu}} is analyzed within the minimal supersymmetric standard model (MSSM), the derived constraints on the parameter space are modified significantly: If (g-2){sub {mu}} is used to determine tan{beta} as a function of the other MSSM parameters, our corrections decrease tan{beta} by roughly 10% for tan{beta}=50.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonstationary stochastic charge fluctuations of a dust particle in plasmas

Stochastic charge fluctuations of a dust particle that are due to discreteness of electrons and ions in plasmas can be described by a one-step process master equation [T. Matsoukas and M. Russell, J. Appl. Phys. 77, 4285 (1995)] with no exact solution. In the present work, using the system size expansion method of Van Kampen along with the linear noise approximation, a Fokker-Planck equation with an exact Gaussian solution is developed by expanding the master equation. The Gaussian solution has time-dependent mean and variance governed by two ordinary differential equations modeling the nonstationary process of dust particle charging. The model is tested via the comparison of its results to the results obtained by solving the master equation numerically. The electron and ion currents are calculated through the orbital motion limited theory. At various times of the nonstationary process of charging, the model results are in a very good agreement with the master equation results. The deviation is more significant when the standard deviation of the charge is comparable to the mean charge in magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-03: Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data

Purpose: This work aims at reducing the uncertainty in proton stopping power (SP) estimation by a novel combination of a linear, separable basis vector model (BVM) for stopping power calculation (Med Phys 43:600) and a statistical, model-based dual-energy CT (DECT) image reconstruction algorithm (TMI 35:685). The method was applied to experimental data. Methods: BVM assumes the photon attenuation coefficients, electron densities, and mean excitation energies (I-values) of unknown materials can be approximated by a combination of the corresponding quantities of two reference materials. The DECT projection data for a phantom with 5 different known materials was collected on a Philips Brilliance scanner using two scans at 90 kVp and 140 kVp. The line integral alternating minimization (LIAM) algorithm was used to recover the two BVM coefficient images using the measured source spectra. The proton stopping powers are then estimated from the Bethe-Bloch equation using electron densities and I-values derived from the BVM coefficients. The proton stopping powers and proton ranges for the phantom materials estimated via our BVM based DECT method are compared to ICRU reference values and a post-processing DECT analysis (Yang PMB 55:1343) applied to vendorreconstructed images using the Torikoshi parametric fit model (tPFM). Results: For the phantom materials, the average stopping power estimations for 175 MeV protons derived from our method are within 1% of the ICRU reference values (except for Teflon with a 1.48% error), with an average standard deviation of 0.46% over pixels. The resultant proton ranges agree with the reference values within 2 mm. Conclusion: Our principled DECT iterative reconstruction algorithm, incorporating optimal beam hardening and scatter corrections, in conjunction with a simple linear BVM model, achieves more accurate and robust proton stopping power maps than the post-processing, nonlinear tPFM based DECT analysis applied to conventional reconstructions of low and high energy scans. Funding Support: NIH R01CA 75371; NCI grant R01 CA 149305.

60 APPLIED LIFE SCIENCES↗

Quantification of the importance of the modeling fidelity in the Best Estimate Plus Uncertainty analysis

In this work, the multi-physics coupling of CTF-PARCS for both steady-state and transient simulations is evaluated focusing on the quantification of the importance of the modeling fidelity when applied to the Best Estimate Plus Uncertainty safety analysis. For the steady-state, a Picard iteration approach is adopted in the coupled code while for the transient an explicit approach has been developed as a first step. The CTF-PARCS coupling is applied to the REA at HFP BOC scenario proposed in the exercise I-2c of LWR-UAM benchmark Phase III. Two different modeling choices are investigated for the nominal calculations. The first consists of including the 3D burnup information in CTF, and the second of modeling the spacers grids in both PARCS and CTF. It is observed that due to the degradation of the fuel thermal conductivity, the 3D burnup inclusion in CTF leads to significant higher centerline temperatures than the base case, with a difference up to 300 K. The spacer grids modeling shows the expected power and temperature decrease in the axial positions of the spacer grids. For the uncertainty quantification study, the multi-physics modeling including the burnup information in CTF is used. The results show that the inserted reactivity has a relative standard deviation of 13.6% mainly attributed to the nuclear data. The maximum linear power has a relative standard deviation of 16.2% due to the nuclear data as well, while the maximum centerline temperature has a relative standard deviation of 3.5% primarily caused by the fuel thermal conductivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary Statistics for Homemade ?Play Dough? -- Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a homemade Play Dough{trademark}-like material, designated as PDA. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2700 LMHU{sub D} 100kVp to a low of about 1200 LMHUD at 300kVp. The standard deviation of each measurement is around 10% to 15% of the mean. The entropy covers the range from 6.0 to 7.4. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the detailed chemical composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 10. LLNL prepared about 50mL of the homemade 'Play Dough' in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

Probing New physics with high-redshift quasars: axions and non-standard cosmology

The Hubble diagram of quasars, as candidates to “standardizable” candles, has been used to measure the expansion history of the Universe at late times, up to very high redshifts ( z ~ 7). It has been shown that this history, as inferred from the quasar dataset, deviates at ≳ 3 σ level from the concordance (ΛCDM) cosmology model preferred by the cosmic microwave background (CMB) and other datasets. In this article, we investigate whether new physics beyond ΛCDM (BΛCDM) or beyond the Standard Model (BSM) could make the quasar data consistent with the concordance model. We first show that an effective redshift-dependent relation between the quasar UV and X-ray luminosities, complementing previous phenomenological work in the literature, can potentially remedy the discrepancy. Such a redshift dependence can be realized in a BSM model with axion-photon conversion in the intergalactic medium (IGM), although the preferred parameter space is in tension with various other astrophysical constraints on axions, at a level depending on the specific assumptions made regarding the IGM magnetic field. We briefly discuss a variation of the axion model that could evade these astrophysical constraints. On the other hand, we show that models beyond ΛCDM such as one with a varying dark energy equation of state ( w CDM) or the phenomenological cosmographic model with a polynomial expansion of the luminosity distance, cannot alleviate the tension. The code for our analysis, based on emcee [1] and corner.py [2], is publicly available at github.com/ChenSun-Phys/high_z_candles.

79 ASTRONOMY AND ASTROPHYSICS↗